868 resultados para Bradley-Doppes, Peggy


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To study the impact of powder flow properties on dosator filling systems, with particular focus on improvements in dose weight accuracy and repeatability. Method: This study evaluates a range of critical powder flow properties such as: flow function, cohesion, wall friction, adhesion to wall surfaces, density/compressibility data, stress ratio “K” and gas permeability. The characterisations of the powders considered in this study were undertaken using an annular shear cell using a sample size of 0.5 litres. This tester also incorporated the facility to measure bed expansion during shear in addition to contraction under consolidation forces. A modified Jenike type linear wall friction tester was used to develop the failure loci for the powder sample in conjunction with multiple wall samples (representing a variety of material types and surface finishes). Measurements of the ratio of applied normal stress versus lateral stress were determined using a piece of test equipment specifically designed for the purpose. Results: The correct characterisation of powders and the incorporation of this data into the design of process equipment are recognised as critical for reliable and accurate operation. An example of one aspect of this work is the stress ratio “K”. This characteristic is not well understood or correctly interpreted in many cases – despite its importance. Fig 1 [Omitted] (illustrates a sample of test data. The slope of the line gives the stress ratio in a uniaxial compaction system – indicating the behaviour of the material under compaction during dosing processes. Conclusions: A correct assessment of the bulk powder properties for a given formulation can allow prediction of: cavity filling behaviour (and hence dosage), efficiency of release from dosator, and strength and stability of extruded dose en route to capsule filling Influences over the effectiveness of dosator systems have been shown to be impacted upon by: bed pre-compaction history, gas permeability in the bed (with respect to local density effects), and friction effects for materials of construction for dosators

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To develop an improved mathematical model for the prediction of dose accuracy of Dosators - based upon the geometry of the machine in conjunction with measured flow properties of the powder. Methods: A mathematical model has been created, based on a analytical method of differential slices - incorporating measured flow properties. The key flow properties of interest in this investigation were: flow function, effective angle of wall friction, wall adhesion, bulk density, stress ratio K and permeability. To simulate the real process and (very importantly) validate the model, a Dosator test-rig has been used to measure the forces acting on the Dosator during the filling stage, the force required to eject the dose and the dose weight. Results: Preliminary results were obtained from the Dosator test-rig. Figure 1 [Omitted] shows the dose weight for different depths to the bottom of the powder bed at the end of the stroke and different levels of pre-compaction of the powder bed. A strong influence over dose weight arising from the proximity between the Dosator and the bottom of the powder bed at the end of the stroke and the conditions of the powder bed has been established. Conclusions: The model will provide a useful tool to predict dosing accuracy and, thus, optimise the future design of Dosator based equipment technology – based on measured bulk properties of the powder to be handled. Another important factor (with a significant influence) on Dosator processes, is the condition of the powder bed and the clearance between the Dosator and the bottom of the powder bed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dosators and other dosing mechanisms operating on generally similar principles are very widely used in the pharmaceutical industry for capsule filling, and for dosing products that are delivered to the customer in powder form such as inhalers. This is a trend that is set to increase. However a significant problem for this technology is being able to predict how accurately and reliably, new drug formulations will be dosed from these machines prior to manufacture. This paper presents a review of the literature relating to powder dosators which considers mathematical models for predicting dosator performance, the effects of the dosator geometry and machine settings on the accuracy of the dose weight. An overview of a model based on classical powder mechanics theory that has been developed at The University of Greenwich is presented. The model uses inputs from a range of powder characterisation tests including, wall friction, bulk density, stress ratio and permeability. To validate the model it is anticipated that it will be trialled for a range of powders alongside a single shot dosator test rig.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Various models for predicting discharge rates have been developed over the last four decades by many research workers (notably Beverloo [1], Johanson [2], Brown [3], Carleton [4], Crewdson [5], Nedderman [6], Gu [7].). In many cases these models offer comparable approaches to the prediction of discharge rates of bulk particulates from storage equipment when solely gravity is acting to initiate flow (since they invariably consider the use of mass-flow design equipment). The models that have been developed consider a wide range of bulk particulates (coarse, incompressible, fine, cohesive) and most contemporary works have incorporated validation against test programmes. Research currently underway at The Wolfson Centre for Bulk Solids Handling Technology, University of Greenwich, has considered the relative performance of these models with respect to a range of bulk properties and with particular focus upon the flexibility of the models to cater for different geometrical factors for vessels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Annular, ring or torsional shear testers are commonly used in bulk solids handling research for the purpose of powder characterisation or equipment design. This paper reports from a DEFRA sponsored project which aims to develop an industrial powder flow-ability tester, (based on the annular shear tester) that is economic to buy and quick and easy to use in trained but unskilled hands. This paper compares the wall failure loci measured with an annular shear cell with measurements obtained using the accepted standard wall friction tester, the Jenike shear cell. These wall failure loci have been measured for several bulk solids which range from fine cohesive powders to free-flowing granular materials, on a stainless steel 304 2B wall surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many different models have been postulated over the years for sizing of feeder drives; these models have different bases, some rationally based and others more rule-of-thumb. Experience of Jenike & Johanson and likewise of The Wolfson Centre in trouble-shooting feeder drives has shown that drive powers are often poorly matched, so there is clearly still some way to go towards establishing a universally-used reliable approach. This paper presents an on-going programme of work designed to measure feeder forces experimentally on a purpose designed testing rig, and to compare these against some of the best known available models, and also against a full size installation. One aspect which is novel is the monitoring of the transition between the “filling stress field” load on the feeder and the “flowing stress field” load.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accurate design of two-phase air-solid pipelines requires data from flow and pressure measurements, requiring the appropriate positioning and selection of sensors as well as judicious processing of signals. This paper shows how detailed measurements of pressure profiles have been obtained for use in design of improved pneumatic conveying pipelines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transport of particulate clay occurs during some extremely cold weather conditions typically in the winter in the far North area. During the transport and temporary storage time, the clay may cake inside a rail or road wagon or in a silo, and consequently be difficult to be discharged from the containers. This paper studied caking strength of a granulated clay powder with a certain water moisture content of 18% for influences of temperature, packing stress and freezing time. The temperature tested was -5 oC, -10 oC and -20 oC. Because the clay powder may be packed at different bed depth, the study was undertaken across the packing stress range at 8.3 kPa (1 m bed depth), 25.0 kPa (3 m) and 75.0 kPa (9 m). Freezing time varied between 4 hours (transport) and 18 hours (overnight). During the tests, failure of caked materials was measured using a QTS texture analyzer and the caking strength of frozen samples was calculated. Influences on freeze caking of granular clay in storage or transport are discussed briefly. Some conclusions are made at the end of the paper,including recommendations for practical methods for mitigating these problems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gas-blast and centrifugal-accelerator testers are the two most commonly used erosion testers. An experimental and analytical study was made of the effect of particle characteristics (size, shape and concentration) on particle dynamics in each of these testers. Analysis showed that in the gas-blast tester both particle velocity and the dispersion angle of the particle jet were relatively sensitive to the particle characteristics. Particle characteristics, within the ranges studied, had little influence in the centrifugal accelerator tester. Consequently, during an erosion test, the range of particle velocities and dispersion angles in the gas-blast tester ismuch wider than in the centrifugal-accelerator tester. It was concluded that the centrifugal-accelerator tester gave closer control of the important erosion test parameters and therefore more consistent erosion test measurements. However, one drawback of the centrifugal-accelerator tester is the need to account for erosion effects associated with the impact of rotating particles, an inherent feature of this tester.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Particle degradation can be a significant issue in particulate solids handling and processing, particularly in pneumatic conveying systems, in which high-speed impact is usually the main contributory factor leading to changes in particle size distribution (comparing the material to its virgin state). However, other factors may strongly influence particles breakage as well, such as particle concentrations, bend geometry,and hardness of pipe material. Because of such complex influences, it is often very difficult to predict particle degradation accurately and rapidly for industrial processes. In this article, a general method for evaluating particle degradation due to high-speed impacts is described, in which the breakage properties of particles are quantified using what are known as "breakage matrices". Rather than a pilot-size test facility, a bench-scale degradation tester has been used. Some advantages of using the bench-scale tester are briefly explored. Experimental determination of adipic acid has been carried out for a range of impact velocities in four particle size categories. Subsequently, particle breakage matrices of adipic acid have been established for these impact velocities. The experimental results show that the "breakage matrices" of particles is an effective and easy method for evaluation of particle degradation due to high-speed impacts. The possibility of the "breakage matrices" approach being applied to a pneumatic conveying system is also explored by a simulation example.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The firm adhesion of flavouring particles onto crisp surfaces during coating processes is a major concern in the snack production industry. Detachment of flavouring powders from products during handling and production stages can lead to substantial financial losses for the industry, in terms of variable flavour performance and extended cleaning down time of fugitive particle build-up on process equipment. Understanding the adhesion strength of applied bulk particulates used for flavouring formulations will help analysts to evaluate the efficiency of coating processes and potentially enable them to assess the adhesion strength of newly formulated flavouring powder prior to commitment to full scale plant trials. A rapid prototype of a novel adhesion tester has been designed and constructed. The apparatus operates according to the principle of impact force acting on particles attached to the surface of the food substrate. The main component is a circular plate to which four sample holders are attached and which is subjected to vertical travel down a guide shaft. Several flavouring powders have been tested extensively. By plotting the detachment versus impact force, the difference obtained between adhesion strength of different flavouring powders (which is a strong function of particle size) has been discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Segregation or de-blending of bulk particulates is a problem that is encountered in many industrial sectors. The magnitude of segregation can often determine whether a complete production batch can be transferred for onward processing within the plant or released to market. It is a phenomenon that impacts directly upon the profitability of a process. Segregation can occur through a coincidence of a range of variables that relate to the process and bulk particulate properties, common mechanisms for this include; percolation, surface effect (rolling) and elutriation. The importance to industry of predicting the sensitivity of bulk particulates to segregation cannot be under-estimated, and to this end various test procedures have been developed. Within many industries striving to improve product quality and reduce wastage, the determination of variability in blend consistency caused by segregation is an increasing priority. This paper considers recent work undertaken to evaluate the effects of multiple handling operations on the degree of segregation that results. The bulk properties of segregability (and resulting flowability) can not only influence the product consistency, but can have great influence over the process (production) control and performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper the dependence of the power consumption of pneumatic conveyors upon conveyed materials, pipeline route and bore, and mode of flow has been examined. The findings are that, with different materials and modes of flow, not only is the amount of power consumed very different but it varies in different ways with pipe bore and routing. Additionally it has been found that, for any given conveying system, the choice of air mover also has a strong influence on the power requirement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stenotrophomonas maltophilia PML168 was isolated from Wembury Beach on the English Coast from a rock pool following growth and selection on agar plates. Here we present the permanent draft genome sequence, which has allowed prediction of function for several genes encoding enzymes relevant to industrial biotechnology, including a novel flavoprotein monooxygenase.