846 resultados para BATTERY
Resumo:
Volumes of data used in science and industry are growing rapidly. When researchers face the challenge of analyzing them, their format is often the first obstacle. Lack of standardized ways of exploring different data layouts requires an effort each time to solve the problem from scratch. Possibility to access data in a rich, uniform manner, e.g. using Structured Query Language (SQL) would offer expressiveness and user-friendliness. Comma-separated values (CSV) are one of the most common data storage formats. Despite its simplicity, with growing file size handling it becomes non-trivial. Importing CSVs into existing databases is time-consuming and troublesome, or even impossible if its horizontal dimension reaches thousands of columns. Most databases are optimized for handling large number of rows rather than columns, therefore, performance for datasets with non-typical layouts is often unacceptable. Other challenges include schema creation, updates and repeated data imports. To address the above-mentioned problems, I present a system for accessing very large CSV-based datasets by means of SQL. It's characterized by: "no copy" approach - data stay mostly in the CSV files; "zero configuration" - no need to specify database schema; written in C++, with boost [1], SQLite [2] and Qt [3], doesn't require installation and has very small size; query rewriting, dynamic creation of indices for appropriate columns and static data retrieval directly from CSV files ensure efficient plan execution; effortless support for millions of columns; due to per-value typing, using mixed text/numbers data is easy; very simple network protocol provides efficient interface for MATLAB and reduces implementation time for other languages. The software is available as freeware along with educational videos on its website [4]. It doesn't need any prerequisites to run, as all of the libraries are included in the distribution package. I test it against existing database solutions using a battery of benchmarks and discuss the results.
Resumo:
OBJECTIVE: The aim of this study was to assess the association between frailty and risk for heart failure (HF) in older adults. BACKGROUND: Frailty is common in the elderly and is associated with adverse health outcomes. Impact of frailty on HF risk is not known. METHODS: We assessed the association between frailty, using the Health ABC Short Physical Performance Battery (HABC Battery) and the Gill index, and incident HF in 2825 participants aged 70 to 79 years. RESULTS: Mean age of participants was 74 ± 3 years; 48% were men and 59% were white. During a median follow up of 11.4 (7.1-11.7) years, 466 participants developed HF. Compared to non-frail participants, moderate (HR 1.36, 95% CI 1.08-1.71) and severe frailty (HR 1.88, 95% CI 1.02-3.47) by Gill index was associated with a higher risk for HF. HABC Battery score was linearly associated with HF risk after adjusting for the Health ABC HF Model (HR 1.24, 95% CI 1.13-1.36 per SD decrease in score) and remained significant when controlled for death as a competing risk (HR 1.30; 95% CI 1.00-1.55). Results were comparable across age, sex, and race, and in sub-groups based on diabetes mellitus or cardiovascular disease at baseline. Addition of HABC Battery scores to the Health ABC HF Risk Model improved discrimination (change in C-index, 0.014; 95% CI 0.018-0.010) and appropriately reclassified 13.4% (net-reclassification-improvement 0.073, 95% CI 0.021-0.125; P = .006) of participants (8.3% who developed HF and 5.1% who did not). CONCLUSIONS: Frailty is independently associated with risk of HF in older adults.
Resumo:
Currently, many drivers experience some difficulty in viewing the road ahead of them during times of reduced visibility, such as rain, snow, fog, or the darkness of night- Recent studies done by the National Safety Council provide a detailed contrast between fatal accidents occurring during the day and night. Revealed was that the motor vehicle night death rate (4.41 deaths per 100 million miles driven) was sharply higher than the corresponding death rate during daylight hours (1.21). By providing a delineating system powered by the natural resource of solar power, a constant source of visibility may be maintained throughout the evening. Along with providing enough light to trace the outline of the road, other major goals defined in producing this delineator system are as follows: 1. A strong and durable design that would protect the internal components and survive extreme weather conditions. 2. A low maintenance system where components need few repairs or replacements. 3. A design which makes all components accessible in the event that maintenance is needed, but also prevents vandalism. 4. A design that provides greater visibility to drivers and will not harm a vehicle or its passengers in the event of a collision. This solar powered highway delineator consists of an adjustable solar array, a light fixture, and a standard delineator pole. The solar array houses and protects the solar panels, and can be easily adjusted to obtain a maximum amount of sunlight. The light fixture primarily houses the battery, the circuit and the light assembly. Both components allow for easy accessibility and reduce vandalism using internal connections for bolts and wires. The delineator mounting pole is designed to extensively deform in the event of a collision, therefore reducing any harm caused to the vehicle and/or the passengers. The cost of a single prototype to be produced is approximately $70.00 excluding labor costs. However, these material and labor costs will be greatly reduced if a large number of delineators are produced. It is recommended that the Iowa Department of Transportation take full advantage of the research and development put into this delineator design. The principles used in creating this delineator can be used to provide an outline for drivers to follow, or on a larger scale, provide actual roadway lighting in areas where it was never before possible or economically feasible. In either event, the number of fatal accidents will be decreased due to the improved driver visibility in the evening.
Resumo:
Macrophage migration inhibitory factor (MIF), a proinflammatory cytokine, is considered an attractive therapeutic target in multiple inflammatory and autoimmune disorders. In addition to its known biologic activities, MIF can also function as a tautomerase. Several small molecules have been reported to be effective inhibitors of MIF tautomerase activity in vitro. Herein we employed a robust activity-based assay to identify different classes of novel inhibitors of the catalytic and biological activities of MIF. Several novel chemical classes of inhibitors of the catalytic activity of MIF with IC(50) values in the range of 0.2-15.5 microm were identified and validated. The interaction site and mechanism of action of these inhibitors were defined using structure-activity studies and a battery of biochemical and biophysical methods. MIF inhibitors emerging from these studies could be divided into three categories based on their mechanism of action: 1) molecules that covalently modify the catalytic site at the N-terminal proline residue, Pro(1); 2) a novel class of catalytic site inhibitors; and finally 3) molecules that disrupt the trimeric structure of MIF. Importantly, all inhibitors demonstrated total inhibition of MIF-mediated glucocorticoid overriding and AKT phosphorylation, whereas ebselen, a trimer-disrupting inhibitor, additionally acted as a potent hyperagonist in MIF-mediated chemotactic migration. The identification of biologically active compounds with known toxicity, pharmacokinetic properties, and biological activities in vivo should accelerate the development of clinically relevant MIF inhibitors. Furthermore, the diversity of chemical structures and mechanisms of action of our inhibitors makes them ideal mechanistic probes for elucidating the structure-function relationships of MIF and to further determine the role of the oligomerization state and catalytic activity of MIF in regulating the function(s) of MIF in health and disease.
Resumo:
Membrane-active antimicrobial peptides, such as polymyxin B (PxB), are currently in the spotlight as potential candidates toovercome bacterial resistance. We have designed synthetic analogs ofPxB in order to determine the structural requirements for membraneaction. Since the mechanism of action of PxB involves interaction withboth the outer membrane and the cytoplasmic membrane of Gramnegative bacteria, we have used an approach based on mimicking theouter layers of these membranes using monolayers, Langmuir-Blodgettfilms and unilamelar vesicles, and applying a battery of biophysicalmethods in order to dissect the different events of membraneinteraction. Collectively, results indicate that the PxB analogues act inthe bacterial membrane by the same mechanism than PxB, and that cationic amphipathicity determines peptide activity.
Resumo:
Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.
Resumo:
Despite that cognitive impairment is a known early feature present in multiple sclerosis (MS) patients, the biological substrate of cognitive deficits in MS remains elusive. In this study, we assessed whether T1 relaxometry, as obtained in clinically acceptable scan times by the recent Magnetization Prepared 2 Rapid Acquisition Gradient Echoes (MP2RAGE) sequence, may help identifying the structural correlate of cognitive deficits in relapsing-remitting MS patients (RRMS). Twenty-nine healthy controls (HC) and forty-nine RRMS patients underwent high-resolution 3T magnetic resonance imaging to obtain optimal cortical lesion (CL) and white matter lesion (WML) count/volume and T1 relaxation times. T1 z scores were then obtained between T1 relaxation times in lesion and the corresponding HC tissue. Patient cognitive performance was tested using the Brief Repeatable Battery of Neuro-psychological Tests. Multivariate analysis was applied to assess the contribution of MRI variables (T1 z scores, lesion count/volume) to cognition in patients and Bonferroni correction was applied for multiple comparison. T1 z scores were higher in WML (p < 0.001) and CL-I (p < 0.01) than in the corresponding normal-appearing tissue in patients, indicating relative microstructural loss. (1) T1 z scores in CL-I (p = 0.01) and the number of CL-II (p = 0.04) were predictors of long-term memory; (2) T1 z scores in CL-I (β = 0.3; p = 0.03) were independent determinants of long-term memory storage, and (3) lesion volume did not significantly influenced cognitive performances in patients. Our study supports evidence that T1 relaxometry from MP2RAGE provides information about microstructural properties in CL and WML and improves correlation with cognition in RRMS patients, compared to conventional measures of disease burden.
Resumo:
Objectives: Psychomotor retardation is part of Major Depression (MD) diagnosis criteria and has been assimilated to bradykinesia, even though there is a clear lack of objective measurement of motor activity in MD. We conducted a study to evaluate bradykinesia, posture and gait parameters in MD patients with an ambulatory system, allowing continuous motor measurements. Methods: Patients with DSM-IV MD and healthy controls matched for age and sex were asked to carry on with their usual activities while being recorded for 6 hours by a wireless autonomous ambulatory system, containing miniature gyroscopes, data-logger, battery and flash memory. allowing continuous recording of upper limbs movements (speed, amplitude and activity (% of time with movement)), posture (% of time standing, walking, lying or sitting) and gait parameters (speed, cadence, stance, double support, stride). Results: Hands activity was significantly lower in depressed patients, as compared to controls (MD: 40%, controls: 60%; p<0.05). Speed of hand movements (p= 0.13) and their amplitude (p=0.71) were similar to controls. MD patients had a trend to spend more time lying or sitting than controls (p=0.06) but did not differ in terms of any gait parameters. Conclusion: Patients with MD displayed less hand movements than controls and tended to spend more time lying or sitting over 6 hours, but did not differ in terms of speed and amplitude of movement, nor in gait parameters. These results suggest that psychomotor retardation classically described in MD might be the expression of a paucity of movement rather than a bradykinesia as observed in parkinsonism and might involved different (nondopaminergic) mechanisms.
Resumo:
Membrane-active antimicrobial peptides, such as polymyxin B (PxB), are currently in the spotlight as potential candidates toovercome bacterial resistance. We have designed synthetic analogs ofPxB in order to determine the structural requirements for membraneaction. Since the mechanism of action of PxB involves interaction withboth the outer membrane and the cytoplasmic membrane of Gramnegative bacteria, we have used an approach based on mimicking theouter layers of these membranes using monolayers, Langmuir-Blodgettfilms and unilamelar vesicles, and applying a battery of biophysicalmethods in order to dissect the different events of membraneinteraction. Collectively, results indicate that the PxB analogues act inthe bacterial membrane by the same mechanism than PxB, and that cationic amphipathicity determines peptide activity.
Resumo:
Las dificultades de lectura y escritura se pueden detectar desde el momento en que los niños y niñas inician el aprendizaje de la lectoescritura en la etapa de Educación Infantil. En algunos casos estos alumnos reciben un apoyo escolar que en muchas ocasiones no conlleva las mejoras esperadas, siendo las técnicas y metodologías de refuerzo aplicadas ineficaces. El problema, desde nuestro punto de vista, empieza con el diagnóstico que se realiza a estos jóvenes, que determina las directrices de la intervención idónea en cada caso. La Teoría PASS de la inteligencia nos permite conocer qué procesos están implicados cuando el niño lee o escribe, y parte de la premisa de que si conocemos el perfil cognitivo de un alumno que presenta dificultades podremos entender como estas se originan. Para conocer este perfil cognitivo (los cuatro procesos cognitivos que describe esta teoría: Planificación, Atención, Simultaneo y Secuencial) utilizamos la batería DN-CAS (Das & Naglieri: Cognitive Assessment System). El perfil obtenido al aplicar el DN-CAS nos permitirá conocer el origen de las dificultades de lectura y escritura, saber cuando está justificada una dislexia, descartar problemas emocionales o la presencia de los mismos y diseñar la intervención más adecuada en cada situación
Resumo:
OBJECTIVE: Standard cardiopulmonary bypass (CPB) circuits with their large surface area and volume contribute to postoperative systemic inflammatory reaction and hemodilution. In order to minimize these problems a new approach has been developed resulting in a single disposable, compact arterio-venous loop, which has integral kinetic-assist pumping, oxygenating, air removal, and gross filtration capabilities (CardioVention Inc., Santa Clara, CA, USA). The impact of this system on gas exchange capacity, blood elements and hemolysis is compared to that of a conventional circuit in a model of prolonged perfusion. METHODS: Twelve calves (mean body weight: 72.2+/-3.7 kg) were placed on cardiopulmonary bypass for 6 h with a flow of 5 l/min, and randomly assigned to the CardioVention system (n=6) or a standard CPB circuit (n=6). A standard battery of blood samples was taken before bypass and throughout bypass. Analysis of variance was used for comparison. RESULTS: The hematocrit remained stable throughout the experiment in the CardioVention group, whereas it dropped in the standard group in the early phase of perfusion. When normalized for prebypass values, both profiles differed significantly (P<0.01). Both O2 and CO2 transfers were significantly improved in the CardioVention group (P=0.04 and P<0.001, respectively). There was a slightly higher pressure drop in the CardioVention group but no single value exceeded 112 mmHg. No hemolysis could be detected in either group with all free plasma Hb values below 15 mg/l. Thrombocyte count, when corrected by hematocrit and normalized by prebypass values, exhibited an increased drop in the standard group (P=0.03). CONCLUSION: The CardioVention system with its concept of limited priming volume and exposed foreign surface area, improves gas exchange probably because of the absence of detectable hemodilution, and appears to limit the decrease in the thrombocyte count which may be ascribed to the reduced surface. Despite the volume and surface constraints, no hemolysis could be detected throughout the 6 h full-flow perfusion period.
Resumo:
L’objectiu d’aquest estudi és crear un programa de prevenció de la demència a partir d’activitats i ocupacions significatives. S’utilitzarà la metodologia quantitativa i es realitzarà un estudi experimental i seqüencial. L’estudi es realitzarà al medi rural, concretament a Ripoll (Sant Bernabé). Per tal de poder obtenir la els participants per la realització de l’estudi s’utilitzarà el mostreig aleatori estratificat amb el qual s’obtindrà dos grups de 16 persones de 50 a 55 anys. Els instruments que s’utilitzaran per tal de poder obtenir les dades de l’estudi són el “Qüestionari internacional d’activitat física” (2002), la bateria neuropsicològica anomenada “Test de Barcelona abreviat” (1997), “L’escala de qualitat de vida” (2008), i per acabar s’utilitzarà el “Test KIMED” (2004). Una primera limitació pot ser que l’ajuntament no ens faciliti les dades per tal de poder realitzar el mostreig aleatori estratificat per tal de poder aconseguir la mostra. També pot ser que l’ajuntament no cedeixi el lloc per tal de poder realitzar la intervenció. Un altre possible limitació pot ser el temps atmosfèric. I per acabar també ens podem torbar amb l’abandonament del programa per part d’un o més participants.
Resumo:
BACKGROUND: Direct colonic electrical stimulation may prove to be a treatment option for specific motility disorders such as chronic constipation. The aim of this study was to provoke colonic contractions using electrical stimulation delivered from a battery-operated device. METHODS: Electrodes were inserted into the caecal seromuscular layer of eight anaesthetized pigs. Contractions were induced by a neurostimulator (Medtronic 3625). Caecal motility was measured simultaneously by video image analysis, manometry and a technique assessing colonic transit. RESULTS: Caecal contractions were generated using 8-10 V amplitude, 1000 micros pulse width, 120 Hz frequency for 10-30 s, with an intensity of 7-15 mA. The maximal contraction strength was observed after 20-25 s. Electrical stimulation was followed by a relaxation phase of 1.5-2 min during which contractions propagated orally and aborally over at least 10 cm. Spontaneous and stimulated caecal motility values were significantly different for both intraluminal pressure (mean(s.d.) 332(124) and 463(187) mmHg respectively; P < 0.001, 42 experiments) and movement of contents (1.6(0.9) and 3.9(2.8) mm; P < 0.001, 40 experiments). CONCLUSION: Electrical stimulation modulated caecal motility, and provoked localized and propagated colonic contractions.
Resumo:
Background: Postoperative cognitive dysfunction (POCD) occurs frequently after cardiac surgery. Some data suggest that inflammation plays a key role in the development of POCD. N-3 fatty acids have been shown to have a beneficial effect on inflammation. We hypothesised that perioperative n-3 enriched nutrition therapy would reduce the incidence of POCD in this group of patients. Methods: Randomized, double blind placebo controlled trial in patients aged 65 or older undergoing elective cardiac surgery with cardiopulmonary bypass. 2x 250 mL placebo (Ensure Plus™, Abbott Nutrition) or n-3 enriched nutrition therapy (ProSure™ Abbott Nutrition) were administered for ten days starting 5 days prior to surgery. Cognition was assessed preoperatively and 7 days after surgery with the Consortium to Establish a Registry for Alzheimer's Disease - Neuropsychological Assessment Battery (CERAD-NAB) [1]. Results: 16 patients were included. Mean age was 72 } 5.3 for placebo and 75 } 4.8 for ProSure™ respectively. CRP and IL-6 did not differ significantly between groups preoperatively and on postoperative days 1, 3, and 7. Preoperative CERAD total scores were 86 } 10 and 81 } 9 (p = n.s.) for Placebo and ProSure™, respectively. Postoperative scores were 88 } 12, and 77 } 19 (p = n.s.) The change in score was not different between the two groups (Placebo: +3 } 5; ProSure: -5 } 11). Conclusion: In this very small sample no effect of preoperatively started n-3 enriched nutritional supplements on inflammation or cognitive functions were detected. However, there is a large likelihood of a type II error and more patients need to be included to assess possible beneficial effects of this intervention in elderly patients undergoing elective cardiac surgery. 1 Chandler MJ, et al. Neurology. 2005;65:102-6.
Resumo:
A good system of preventive bridge maintenance enhances the ability of engineers to manage and monitor bridge conditions, and take proper action at the right time. Traditionally infrastructure inspection is performed via infrequent periodical visual inspection in the field. Wireless sensor technology provides an alternative cost-effective approach for constant monitoring of infrastructures. Scientific data-acquisition systems make reliable structural measurements, even in inaccessible and harsh environments by using wireless sensors. With advances in sensor technology and availability of low cost integrated circuits, a wireless monitoring sensor network has been considered to be the new generation technology for structural health monitoring. The main goal of this project was to implement a wireless sensor network for monitoring the behavior and integrity of highway bridges. At the core of the system is a low-cost, low power wireless strain sensor node whose hardware design is optimized for structural monitoring applications. The key components of the systems are the control unit, sensors, software and communication capability. The extensive information developed for each of these areas has been used to design the system. The performance and reliability of the proposed wireless monitoring system is validated on a 34 feet span composite beam in slab bridge in Black Hawk County, Iowa. The micro strain data is successfully extracted from output-only response collected by the wireless monitoring system. The energy efficiency of the system was investigated to estimate the battery lifetime of the wireless sensor nodes. This report also documents system design, the method used for data acquisition, and system validation and field testing. Recommendations on further implementation of wireless sensor networks for long term monitoring are provided.