859 resultados para Analog-to-digital converters


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have carried out high contrast imaging of 70 young, nearby B and A stars to search for brown dwarf and planetary companions as part of the Gemini NICI Planet-Finding Campaign. Our survey represents the largest, deepest survey for planets around high-mass stars (≈1.5-2.5 M ☉) conducted to date and includes the planet hosts β Pic and Fomalhaut. We obtained follow-up astrometry of all candidate companions within 400 AU projected separation for stars in uncrowded fields and identified new low-mass companions to HD 1160 and HIP 79797. We have found that the previously known young brown dwarf companion to HIP 79797 is itself a tight (3 AU) binary, composed of brown dwarfs with masses 58$^{+21}_{-20}$ M Jup and 55$^{+20}_{-19}$ M Jup, making this system one of the rare substellar binaries in orbit around a star. Considering the contrast limits of our NICI data and the fact that we did not detect any planets, we use high-fidelity Monte Carlo simulations to show that fewer than 20% of 2 M ☉ stars can have giant planets greater than 4 M Jup between 59 and 460 AU at 95% confidence, and fewer than 10% of these stars can have a planet more massive than 10 M Jup between 38 and 650 AU. Overall, we find that large-separation giant planets are not common around B and A stars: fewer than 10% of B and A stars can have an analog to the HR 8799 b (7 M Jup, 68 AU) planet at 95% confidence. We also describe a new Bayesian technique for determining the ages of field B and A stars from photometry and theoretical isochrones. Our method produces more plausible ages for high-mass stars than previous age-dating techniques, which tend to underestimate stellar ages and their uncertainties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Partindo-se do pressuposto de que o desenho é instrumento de diálogo entre o arquiteto e ele mesmo ou com terceiros e que este tipo de representação vem perdendo espaço para tecnologias digitais, este trabalho tem como objetivo estudar e analisar desenhos de projetos selecionados do arquiteto Paulo Mendes da Rocha, como contribuição para a discussão sobre o papel do desenho analógico no processo projetivo atual. O estudo acerca de quatro projetos (Ginásio do Clube Paulistano, Residência Butantã, Residência Millan e MuBE) se deu através de marcações realizadas pela pesquisadora sobre desenhos originais do arquiteto, com o objetivo de detectar intenções projetuais, conceitos e características dos projetos. Para tanto, foram feitas marcações gráficas sobre os desenhos originais, de maneira a evidenciar uma leitura particular da pesquisadora, permitindo assim uma melhor compreensão dos projetos escolhidos para o estudo. O desenho sobre o desenho marca os pontos que o julgamento considera importantes, tratando-se de uma leitura particular e permitindo melhor compreensão dos projetos para quem o pratica, uma vez que o ato de desenhar está estreitamente relacionado ao de pensar. Optou-se por apresentar as imagens relacionadas a citações diretas de autores

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wir präsentieren zwei Techniken, mit deren Hilfe es erstmals möglich ist, zentralnervöse Synapsen im Zentralen Nervensystem (ZNS) von Drosophila melanogaster reproduzierbar darzustellen und experimentellen Methoden zugänglich zu machen. Die erste Technik beruht auf dem UAS/Gal4-System und ermöglicht die Expression markierter synaptischer Proteine in bekannten reproduzierbaren Neuronen. Die zweite Technik beruht auf der Einzel-Zelltransplantation und erlaubt die reproduzierbare Visualisierung von Synapsen in allen neuralen Zell-Linien des Drosophila Bauchmark.Mit Hilfe dieser Techniken konnte gezeigt werden, dass Neuriten im Bauchmark von Drosophila mindestens drei unterschiedliche Kompartimente aufweisen: 1. Primäre, häufig transversal verlaufende Neurite ohne Output-Synapsen, 2. Seitenneurite von vermutlich rein postsynaptischer Natur und 3. Seitenneurite, die präsynaptisch spezialisierte Regionen aufweisen. Des Weiteren konnten wir nachweisen, dass die Seitenneurite von Motroneuronen im ZNS vermutlich rein postsynaptisch sind. Weitere Beobachtungen veranlassen uns zu der Hypothese, dass motorneuronale Seitenneurite in Drosophila homolog oder analog zu Dendriten in Vertebraten sein könnten.Mit Hilfe der Transplantationstechnik untersuchten wir weiterhin die Funktion des Gens kakapo im ZNS. Obwohl kakapo für die Entwicklung von Synapsen an der Neuromuskulären Verbindung wichtig ist, konnten wir im ZNS keinen Phänotyp feststellen. Dies legt nahe, dass zwischen der Entwicklung von periphären und zentralnervösen Synapsen klare Unterschiede bestehen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Es wurde ein für bodengebundene Feldmessungen geeignetes System zur digital-holographischen Abbildung luftgetragener Objekte entwickelt und konstruiert. Es ist, abhängig von der Tiefenposition, geeignet zur direkten Bestimmung der Größe luftgetragener Objekte oberhalb von ca. 20 µm, sowie ihrer Form bei Größen oberhalb von ca. 100µm bis in den Millimeterbereich. Die Entwicklung umfaßte zusätzlich einen Algorithmus zur automatisierten Verbesserung der Hologrammqualität und zur semiautomatischen Entfernungsbestimmung großer Objekte entwickelt. Eine Möglichkeit zur intrinsischen Effizienzsteigerung der Bestimmung der Tiefenposition durch die Berechnung winkelgemittelter Profile wurde vorgestellt. Es wurde weiterhin ein Verfahren entwickelt, das mithilfe eines iterativen Ansatzes für isolierte Objekte die Rückgewinnung der Phaseninformation und damit die Beseitigung des Zwillingsbildes erlaubt. Weiterhin wurden mithilfe von Simulationen die Auswirkungen verschiedener Beschränkungen der digitalen Holographie wie der endlichen Pixelgröße untersucht und diskutiert. Die geeignete Darstellung der dreidimensionalen Ortsinformation stellt in der digitalen Holographie ein besonderes Problem dar, da das dreidimensionale Lichtfeld nicht physikalisch rekonstruiert wird. Es wurde ein Verfahren entwickelt und implementiert, das durch Konstruktion einer stereoskopischen Repräsentation des numerisch rekonstruierten Meßvolumens eine quasi-dreidimensionale, vergrößerte Betrachtung erlaubt. Es wurden ausgewählte, während Feldversuchen auf dem Jungfraujoch aufgenommene digitale Hologramme rekonstruiert. Dabei ergab sich teilweise ein sehr hoher Anteil an irregulären Kristallformen, insbesondere infolge massiver Bereifung. Es wurden auch in Zeiträumen mit formal eisuntersättigten Bedingungen Objekte bis hinunter in den Bereich ≤20µm beobachtet. Weiterhin konnte in Anwendung der hier entwickelten Theorie des ”Phasenrandeffektes“ ein Objekt von nur ca. 40µm Größe als Eisplättchen identifiziert werden. Größter Nachteil digitaler Holographie gegenüber herkömmlichen photographisch abbildenden Verfahren ist die Notwendigkeit der aufwendigen numerischen Rekonstruktion. Es ergibt sich ein hoher rechnerischer Aufwand zum Erreichen eines einer Photographie vergleichbaren Ergebnisses. Andererseits weist die digitale Holographie Alleinstellungsmerkmale auf. Der Zugang zur dreidimensionalen Ortsinformation kann der lokalen Untersuchung der relativen Objektabstände dienen. Allerdings zeigte sich, dass die Gegebenheiten der digitalen Holographie die Beobachtung hinreichend großer Mengen von Objekten auf der Grundlage einzelner Hologramm gegenwärtig erschweren. Es wurde demonstriert, dass vollständige Objektgrenzen auch dann rekonstruiert werden konnten, wenn ein Objekt sich teilweise oder ganz außerhalb des geometrischen Meßvolumens befand. Weiterhin wurde die zunächst in Simulationen demonstrierte Sub-Bildelementrekonstruktion auf reale Hologramme angewandt. Dabei konnte gezeigt werden, dass z.T. quasi-punktförmige Objekte mit Sub-Pixelgenauigkeit lokalisiert, aber auch bei ausgedehnten Objekten zusätzliche Informationen gewonnen werden konnten. Schließlich wurden auf rekonstruierten Eiskristallen Interferenzmuster beobachtet und teilweise zeitlich verfolgt. Gegenwärtig erscheinen sowohl kristallinterne Reflexion als auch die Existenz einer (quasi-)flüssigen Schicht als Erklärung möglich, wobei teilweise in Richtung der letztgenannten Möglichkeit argumentiert werden konnte. Als Ergebnis der Arbeit steht jetzt ein System zur Verfügung, das ein neues Meßinstrument und umfangreiche Algorithmen umfaßt. S. M. F. Raupach, H.-J. Vössing, J. Curtius und S. Borrmann: Digital crossed-beam holography for in-situ imaging of atmospheric particles, J. Opt. A: Pure Appl. Opt. 8, 796-806 (2006) S. M. F. Raupach: A cascaded adaptive mask algorithm for twin image removal and its application to digital holograms of ice crystals, Appl. Opt. 48, 287-301 (2009) S. M. F. Raupach: Stereoscopic 3D visualization of particle fields reconstructed from digital inline holograms, (zur Veröffentlichung angenommen, Optik - Int. J. Light El. Optics, 2009)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The upgrade of the Mainz Mikrotron (MAMI) electron accelerator facility in 2007 which raised the beam energy up to 1.5,GeV, gives the opportunity to study strangeness production channels through electromagnetic process. The Kaon Spectrometer (KAOS) managed by the A1 Collaboration, enables the efficient detection of the kaons associated with strangeness electroproduction. Used as a single arm spectrometer, it can be combined with the existing high-resolution spectrometers for exclusive measurements in the kinematic domain accessible to them.rnrnFor studying hypernuclear production in the ^A Z(e,e'K^+) _Lambda ^A(Z-1) reaction, the detection of electrons at very forward angles is needed. Therefore, the use of KAOS as a double-arm spectrometer for detection of kaons and the electrons at the same time is mandatory. Thus, the electron arm should be provided with a new detector package, with high counting rate capability and high granularity for a good spatial resolution. To this end, a new state-of-the-art scintillating fiber hodoscope has been developed as an electron detector.rnrnThe hodoscope is made of two planes with a total of 18432 scintillating double-clad fibers of 0.83 mm diameter. Each plane is formed by 72 modules. Each module is formed from a 60deg slanted multi-layer bundle, where 4 fibers of a tilted column are connected to a common read out. The read-out is made with 32 channels of linear array multianode photomultipliers. Signal processing makes use of newly developed double-threshold discriminators. The discriminated signal is sent in parallel to dead-time free time-to-digital modules and to logic modules for triggering purposes.rnrnTwo fiber modules were tested with a carbon beam at GSI, showing a time resolution of 220 ps (FWHM) and a position residual of 270 microm m (FWHM) with a detection efficiency epsilon>99%.rnrnThe characterization of the spectrometer arm has been achieved through simulations calculating the transfer matrix of track parameters from the fiber detector focal plane to the primary vertex. This transfer matrix has been calculated to first order using beam transport optics and has been checked by quasielastic scattering off a carbon target, where the full kinematics is determined by measuring the recoil proton momentum. The reconstruction accuracy for the emission parameters at the quasielastic vertex was found to be on the order of 0.3 % in first test realized.rnrnThe design, construction process, commissioning, testing and characterization of the fiber hodoscope are presented in this work which has been developed at the Institut für Kernphysik of the Johannes Gutenberg - Universität Mainz.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Foreign body ingestion is common and potentially lethal. This study evaluates the use of low-dose Statscans (LODOX) in emergency departments. DESIGN: This comparative cross-sectional study retrospectively assessed 28 289 digital chest x-rays and 2301 LODOX scans performed between 2006 and 2010 at a tertiary emergency centre. The radiographic appearance, image quality and location of ingested foreign bodies were evaluated in standard digital chest and LODOX radiography. The mean irradiation (μSv) and cumulative mean radiation dose per patient with the ingested foreign body were calculated according to literature-based data, together with the sensitivity and specificity for each modality. RESULTS: A total of 62 foreign bodies were detected in 39 patients, of whom 19 were investigated with LODOX and 20 with conventional digital chest radiography. Thirty-three foreign bodies were located in the two upper abdominal quadrants, 21 in the lower quadrants-which are not visible on conventional digital chest radiography-seven in the oesophagus and one in the bronchial system. The sensitivity and specificity of digital chest radiography were 44.4% and 94.1%, respectively, and for the LODOX Statscan 90% and 100%, respectively. The calculated mean radiation dose for LODOX investigations was 184 μS, compared with 524 μS for digital chest radiography. CONCLUSIONS: LODOX Statscan is superior to digital chest radiography in the diagnostic work-up of ingested foreign bodies because it makes it possible to enlarge the field of view to the entire body, has higher sensitivity and specificity, and reduces the radiation dose by 65%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Systematic need for angiography in diagnosis of carotid artery stenosis and indication of surgical therapy is still debated. Noninvasive imaging techniques such as MR angiography (MRA) or CT angiography (CTA) offer an alternative to digital subtraction angiography (DSA) and are increasingly used in clinical practice. In this study, we present the radiological characteristics and clinical results of a series of patients operated on the basis of combined ultrasonography (US)/MRA. METHODS: This observational study included all the patients consecutively operated for a carotid stenosis in our Department from October 1998 to December 2004. The applied MRA protocol had previously been established in a large correlation study with DSA. DSA was used only in case of discordance between US and MRA. The preoperative radiological information furnished by MRA was compared with intraoperative findings. The outcome of the operation was assessed according to ECST criteria. RESULTS: Among 327 patients, preoperative MRA was performed in 278 (85%), DSA in 44 (13.5%) and CT angiography in 5 (1.5%). Most of DSA studies were performed as emergency for preparation of endovascular therapy or for reasons other than carotid stenosis. Eleven additional DSA (3.3%) complemented US/MRA, mostly because diverging diagnosis of subocclusion of ICA. No direct morbidity or intraoperative difficulty was related to preoperative MRA. Combined mortality/major morbidity rate was 0.9% (3 patients) and minor morbidity rate 5.5% (18 patients). CONCLUSIONS: This observational study describes a well-established practice of carotid surgery and supports the exclusive use of non invasive diagnostic imaging for indicating and deciding the operation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In industrial countries, cardiovascular diseases remain the primary cause of death. This review summarizes the role of percutaneous coronary interventions (PCI) in the treatment of coronary heart disease. Interventional therapy of coronary artery disease was initiated in 1977 with the introduction of balloon angioplasty by Andreas Grüntzig in Zurich. Technical progress since has been related to construction and materials of catheters, but also to digital processing of x-ray imaging. Additional methods - rotablation, atherectomy, laser, intravascular ultrasound, and most importantly stent implantation were developed. Only stents significantly changed the procedure. They are today an integral part of PCI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This briefing note was prepared by invitation from the European Parliament's Committee on Culture and Education. It provides an analysis of how the existent EU internal policies reflect the spirit and the letter of the UNESCO Convention on Cultural Diversity. The note suggests further ideas on how the EU may calibrate current practices and explores in a forward-looking manner the possibilities for the Convention’s implementation in future internal policies, understood both as hard and soft EU legal instruments. Particular attention in this query is paid to digital media and their regulatory implications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the procedures used to create a distributed collection of topographic maps of the Austro-Hungarian Empire, the Spezialkarte der Öesterriechisch-ungarnischen Monarchie, Masse. 1:75,000 der natur. This set of maps was published in Vienna over a period of years from 1877 to 1914. The part of the set used in this project includes 776 sheets; all sheets from all editions number over 3,665. The paper contains detailed information on how the maps were converted to digital images, how metadata were prepared, and how Web-browser access was created using ArcIMS Metadata Server. The project, funded by a 2004 National Leadership Grant from the Institute for Museums and Library Science (IMLS), was a joint project of the Homer Babbidge Library Map and Geographic Information Center at the University of Connecticut, the New York Public Library, and the American Geographical Society’s Map Library at the University of Wisconsin Milwaukee.