897 resultados para Active vibration control
Resumo:
We analyze new results on a magnetically levitated body (a block including a magnet whose bottom pole is set in such a way as to repel the upper pole of a magnetic base) excited by a non-ideal energy source (an unbalanced electric motor of limited power supply). These new results are related to the jump phenomena and increase of power required of such sources near resonance are manifestations of a non-ideal system and they are referred as the Sommerfeld effect, which emulates an energy sink. In this work, we also discuss control strategies to be applied to this system, in resonance conditions, in order to decrease its vibration amplitude and avoiding this apparent energy sink.
Fault detection, diagnosis and active fault tolerant control for a satellite attitude control system
Resumo:
Modern control systems are becoming more and more complex and control algorithms more and more sophisticated. Consequently, Fault Detection and Diagnosis (FDD) and Fault Tolerant Control (FTC) have gained central importance over the past decades, due to the increasing requirements of availability, cost efficiency, reliability and operating safety. This thesis deals with the FDD and FTC problems in a spacecraft Attitude Determination and Control System (ADCS). Firstly, the detailed nonlinear models of the spacecraft attitude dynamics and kinematics are described, along with the dynamic models of the actuators and main external disturbance sources. The considered ADCS is composed of an array of four redundant reaction wheels. A set of sensors provides satellite angular velocity, attitude and flywheel spin rate information. Then, general overviews of the Fault Detection and Isolation (FDI), Fault Estimation (FE) and Fault Tolerant Control (FTC) problems are presented, and the design and implementation of a novel diagnosis system is described. The system consists of a FDI module composed of properly organized model-based residual filters, exploiting the available input and output information for the detection and localization of an occurred fault. A proper fault mapping procedure and the nonlinear geometric approach are exploited to design residual filters explicitly decoupled from the external aerodynamic disturbance and sensitive to specific sets of faults. The subsequent use of suitable adaptive FE algorithms, based on the exploitation of radial basis function neural networks, allows to obtain accurate fault estimations. Finally, this estimation is actively exploited in a FTC scheme to achieve a suitable fault accommodation and guarantee the desired control performances. A standard sliding mode controller is implemented for attitude stabilization and control. Several simulation results are given to highlight the performances of the overall designed system in case of different types of faults affecting the ADCS actuators and sensors.
Resumo:
A new control scheme has been presented in this thesis. Based on the NonLinear Geometric Approach, the proposed Active Control System represents a new way to see the reconfigurable controllers for aerospace applications. The presence of the Diagnosis module (providing the estimation of generic signals which, based on the case, can be faults, disturbances or system parameters), mean feature of the depicted Active Control System, is a characteristic shared by three well known control systems: the Active Fault Tolerant Controls, the Indirect Adaptive Controls and the Active Disturbance Rejection Controls. The standard NonLinear Geometric Approach (NLGA) has been accurately investigated and than improved to extend its applicability to more complex models. The standard NLGA procedure has been modified to take account of feasible and estimable sets of unknown signals. Furthermore the application of the Singular Perturbations approximation has led to the solution of Detection and Isolation problems in scenarios too complex to be solved by the standard NLGA. Also the estimation process has been improved, where multiple redundant measuremtent are available, by the introduction of a new algorithm, here called "Least Squares - Sliding Mode". It guarantees optimality, in the sense of the least squares, and finite estimation time, in the sense of the sliding mode. The Active Control System concept has been formalized in two controller: a nonlinear backstepping controller and a nonlinear composite controller. Particularly interesting is the integration, in the controller design, of the estimations coming from the Diagnosis module. Stability proofs are provided for both the control schemes. Finally, different applications in aerospace have been provided to show the applicability and the effectiveness of the proposed NLGA-based Active Control System.
Resumo:
Slip, trip, and fall injuries are frequent among health care workers. Stochastic resonance whole-body vibration training was tested to improve postural control. Participants included 124 employees of a Swiss university hospital. The randomized controlled trial included an experimental group given 8 weeks of training and a control group with no intervention. In both groups, postural control was assessed as mediolateral sway on a force plate before and after the 8-week trial. Mediolateral sway was significantly decreased by stochastic resonance whole-body vibration training in the experimental group but not in the control group that received no training (p < .05). Stochastic resonance whole-body vibration training is an option in the primary prevention of balance-related injury at work.
Resumo:
Background. Community respiratory viruses, mainly RSV and influenza, are significant causes of morbidity and mortality in patients with leukemia and HSCT recipients. The data on impact of PIV infections in these patients is lacking. Methods. We reviewed the records of patients with leukemia and HSCT recipients who developed PIV infection from Oct'02–Nov'07 to determine the outcome of such infections. Results. We identified 200 patients with PIV infections including 80(40%) patients with leukemia and 120 (60%) recipients of HSCT. Median age was 55 y (17-84 y). As compared to HSCT recipients, patients with leukemia had higher APACHE II score (14 vs. 10, p<0.0001); were more likely to have ANC<500 (48% vs. 10%, p<0.0001) and ALC<200 (45% vs. 23.5%, p=0.02). PIV type III was the commonest isolate (172/200, 86%). Most patients 141/200 (70%) had upper respiratory infection (URI), and 59/200 (30%) had pneumonia at presentation. Patients in leukemia group were more likely to require hospitalization due to PIV infection (77% vs. 36% p=0.0001) and were more likely to progress to pneumonia (61% vs. 39%, p=0.002). Fifty five patients received aerosolized ribavirin and/or IVIG. There were no significant differences in the duration of symptoms, length of hospitalization, progression to pneumonia or mortality between the treated verses untreated group. The clinical outcome was unknown in 13 (6%) patients. Complete resolution of symptoms was noted in 91% (171/187) patients and 9% (16/187) patients died. Mortality rate was 17% (16/95) among patients who had PIV pneumonia, with no significant difference between leukemia and HSCT group (16% vs. 17%). The cause of death was acute respiratory failure and/or multi-organ failure in (13, 81%) patients. Conclusions. Patients with leukemia and HSCT could be at high risk for serious PIV infections including PIV pneumonia. Treatment with aerosolized ribavirin and/or IVIG may not have significant effect on the outcome of PIV infection.^
Resumo:
OBJECTIVE. To determine the effectiveness of active surveillance cultures and associated infection control practices on the incidence of methicillin resistant Staphylococcus aureus (MRSA) in the acute care setting. DESIGN. A historical analysis of existing clinical data utilizing an interrupted time series design. ^ SETTING AND PARTICIPANTS. Patients admitted to a 260-bed tertiary care facility in Houston, TX between January 2005 through December 2010. ^ INTERVENTION. Infection control practices, including enhanced barrier precautions, compulsive hand hygiene, disinfection and environmental cleaning, and executive ownership and education, were simultaneously introduced during a 5-month intervention implementation period culminating with the implementation of active surveillance screening. Beginning June 2007, all high risk patients were cultured for MRSA nasal carriage within 48 hours of admission. Segmented Poisson regression was used to test the significance of the difference in incidence of healthcare-associated MRSA during the 29-month pre-intervention period compared to the 43-month post-intervention period. ^ RESULTS. A total of 9,957 of 11,095 high-risk patients (89.7%) were screened for MRSA carriage during the intervention period. Active surveillance cultures identified 1,330 MRSA-positive patients (13.4%) contributing to an admission prevalence of 17.5% in high-risk patients. The mean rate of healthcare-associated MRSA infection and colonization decreased from 1.1 per 1,000 patient-days in the pre-intervention period to 0.36 per 1,000 patient-days in the post-intervention period (P<0.001). The effect of the intervention in association with the percentage of S. aureus isolates susceptible to oxicillin were shown to be statistically significantly associated with the incidence of MRSA infection and colonization (IRR = 0.50, 95% CI = 0.31-0.80 and IRR = 0.004, 95% CI = 0.00003-0.40, respectively). ^ CONCLUSIONS. It can be concluded that aggressively targeting patients at high risk for colonization of MRSA with active surveillance cultures and associated infection control practices as part of a multifaceted, hospital-wide intervention is effective in reducing the incidence of healthcare-associated MRSA.^
Resumo:
En los últimos años se ha construido un gran número de pasarelas peatonales como respuesta a la demanda de nuevas vías de paso en las ciudades. Estas estructuras tienen requisitos constructivos menos exigentes en comparación con otros tipos de puentes, lo cual ha facilitado el desarrollo de diseños con nuevos esquemas resistentes, complicadas geometrías y el empleo de nuevos materiales. En general estas estructuras son esbeltas, ligeras y poco amortiguadas, lo que en ocasiones ha generado problemas de vi-braciones al paso de peatones una vez puestas en servicio. Las normativas actuales son cada vez más sensibles a esta problemática, recomendando diseños cuyas frecuencias naturales deben estar alejadas de los rangos de frecuencia de paso típicos de los peatones y fijando límites de confort en forma de valores máximos de aceleración permitidos, asegurándose así un correcto comportamiento de la estructura. En el presente artículo se analiza esta problemática desde un punto de vista práctico. Para ello se muestran los puntos clave de las normativas y guías de diseño de pasarelas que se pueden encontrar actualmente en la bibliografía, se presentan las técnicas que habitualmente se emplean en el análisis dinámico experimental de estas estructuras, y se comentan las soluciones a las que generalmente se recurre para mejorar su comportamiento dinámico. Por último, se muestran los trabajos llevados a cabo por el Centro Tecnológico CARTIF en colaboración con las Universidades de Valladolid y Castilla-La Mancha en la pasarela peatonal del Museo de la Ciencia de Valladolid. Estos trabajos incluyen: (1) el estudio dinámico de los tres vanos metálicos de dicha pasarela, (2) el diseño e implementación de un amortiguador de masa sintonizado en el vano más sensible a las vibraciones, (3) la implementación de un amortiguador de masa activo utilizando un excitador electrodinámico, y (4) el desarrollo de pruebas para la verificación del estado de servicio de la pasarela. In the last years, a wide number of footbridges have been built as demand response of more direct pathways in cities. These structures have lower building requirements as compared with standard bridges. This circumstance has facilitated the development of new structural design with complex geometries and innovative materials. As a result, these structures may be slender, light and low damped, leading to vibration problems once in service. The current codes take into account this problem, and recommend designs with natural frequencies away from the typical pedestrian pacing rates and fix comfort limits to guarantee the serviceability of the structure.This paper studies this problem from a practical point of view. Thus, the key points of codes and footbridges guidelines are showed, the typical experimental dynamic analysis techniques are presented, and the usual solutions adopted to improve the dynamic performance of these structures are discussed. Finally, the works carried out on the Valladolid Science Museum Footbridge by Centro Tecnológico CARTIF in collaboration with the Universities of Valladolid and Castilla-La Mancha are showed. These works include: (1) the dynamic study of the three steel spans of the footbridge, (2) the design and implementation of a tuned mass damper in the liveliest span, (3) the implementation of an active mass damper using an electrodynamic shaker, and (4) the development of field tests to assess the serviceability of such span.
Resumo:
This paper presents an adaptive control for the auxiliary circuit, called ARCN (Auxiliary Resonant Commutating Network), used to achieve ZVS in full active bridge converters under a wide load range. Depending on the load conditions, the proposed control adapts the timing of the ARCN to minimize the losses. The principle of operation and implementation considerations are presented for a three phase full active bridge converter, proposing different methods to implement the control according to the specifications. The experimental results shown verify the proposed methodology.
Resumo:
In this paper, an intelligent control approach based on neuro-fuzzy systems performance is presented, with the objective of counteracting the vibrations that affect the low-cost vision platform onboard an unmanned aerial system of rotating nature. A scaled dynamical model of a helicopter is used to simulate vibrations on its fuselage. The impact of these vibrations on the low-cost vision system will be assessed and an intelligent control approach will be derived in order to reduce its detrimental influence. Different trials that consider a neuro-fuzzy approach as a fundamental part of an intelligent semi-active control strategy have been carried out. Satisfactory results have been achieved compared to those obtained by means of vibration reduction passive techniques.
Resumo:
Multiscale asymptotic methods developed previously to study macromechanical wave propagation in cochlear models are generalized here to include active control of a cochlear partition having three subpartitions, the basilar membrane, the reticular lamina, and the tectorial membrane. Activation of outer hair cells by stereocilia displacement and/or by lateral wall stretching result in a frequency-dependent force acting between the reticular lamina and basilar membrane. Wavelength-dependent fluid loads are estimated by using the unsteady Stokes' equations, except in the narrow gap between the tectorial membrane and reticular lamina, where lubrication theory is appropriate. The local wavenumber and subpartition amplitude ratios are determined from the zeroth order equations of motion. A solvability relation for the first order equations of motion determines the subpartition amplitudes. The main findings are as follows: The reticular lamina and tectorial membrane move in unison with essentially no squeezing of the gap; an active force level consistent with measurements on isolated outer hair cells can provide a 35-dB amplification and sharpening of subpartition waveforms by delaying dissipation and allowing a greater structural resonance to occur before the wave is cut off; however, previously postulated activity mechanisms for single partition models cannot achieve sharp enough tuning in subpartitioned models.
Resumo:
Mode of access: Internet.
Resumo:
A re-examination of fundamental concepts and a formal structuring of the waveform analysis problem is presented in Part I. eg. the nature of frequency is examined and a novel alternative to the classical methods of detection proposed and implemented which has the advantage of speed and independence from amplitude. Waveform analysis provides the link between Parts I and II. Part II is devoted to Human Factors and the Adaptive Task Technique. The Historical, Technical and Intellectual development of the technique is traced in a review which examines the evidence of its advantages relative to non-adaptive fixed task methods of training, skill assessment and man-machine optimisation. A second review examines research evidence on the effect of vibration on manual control ability. Findings are presented in terms of percentage increment or decrement in performance relative to performance without vibration in the range 0-0.6Rms'g'. Primary task performance was found to vary by as much as 90% between tasks at the same Rms'g'. Differences in task difficulty accounted for this difference. Within tasks vibration-added-difficulty accounted for the effects of vibration intensity. Secondary tasks were found to be largely insensitive to vibration except secondaries which involved fine manual adjustment of minor controls. Three experiments are reported next in which an adaptive technique was used to measure the % task difficulty added by vertical random and sinusoidal vibration to a 'Critical Compensatory Tracking task. At vibration intensities between 0 - 0.09 Rms 'g' it was found that random vibration added (24.5 x Rms'g')/7.4 x 100% to the difficulty of the control task. An equivalence relationship between Random and Sinusoidal vibration effects was established based upon added task difficulty. Waveform Analyses which were applied to the experimental data served to validate Phase Plane analysis and uncovered the development of a control and possibly a vibration isolation strategy. The submission ends with an appraisal of subjects mentioned in the thesis title.
Resumo:
With the advantages and popularity of Permanent Magnet (PM) motors due to their high power density, there is an increasing incentive to use them in variety of applications including electric actuation. These applications have strict noise emission standards. The generation of audible noise and associated vibration modes are characteristics of all electric motors, it is especially problematic in low speed sensorless control rotary actuation applications using high frequency voltage injection technique. This dissertation is aimed at solving the problem of optimizing the sensorless control algorithm for low noise and vibration while achieving at least 12 bit absolute accuracy for speed and position control. The low speed sensorless algorithm is simulated using an improved Phase Variable Model, developed and implemented in a hardware-in-the-loop prototyping environment. Two experimental testbeds were developed and built to test and verify the algorithm in real time.^ A neural network based modeling approach was used to predict the audible noise due to the high frequency injected carrier signal. This model was created based on noise measurements in an especially built chamber. The developed noise model is then integrated into the high frequency based sensorless control scheme so that appropriate tradeoffs and mitigation techniques can be devised. This will improve the position estimation and control performance while keeping the noise below a certain level. Genetic algorithms were used for including the noise optimization parameters into the developed control algorithm.^ A novel wavelet based filtering approach was proposed in this dissertation for the sensorless control algorithm at low speed. This novel filter was capable of extracting the position information at low values of injection voltage where conventional filters fail. This filtering approach can be used in practice to reduce the injected voltage in sensorless control algorithm resulting in significant reduction of noise and vibration.^ Online optimization of sensorless position estimation algorithm was performed to reduce vibration and to improve the position estimation performance. The results obtained are important and represent original contributions that can be helpful in choosing optimal parameters for sensorless control algorithm in many practical applications.^
Resumo:
A continuous time series of annual soil thaw records, extending from 1994 to 2009, is available for comparison with the records of thaw obtained from the Biocomplexity Experiment (BE) for the period 2006-2009. Discontinuous records of thaw at Barrow from wet tundra sites date back to the 1960s. Comparisons between the longer records with the BE observations reveal strong similarities. Records of permafrost temperature, reflecting changes in the annual surface energy exchange, are available from the 1950s for comparison with results from measurement programs begun in 2002. The long-term systematic geocryological investigations at Barrow indicate an increase in permafrost temperature, especially during the last several years. The increase in near-surface permafrost temperature is most pronounced in winter. Marked trends are not apparent in the active-layer record, although subsidence measurements on the North Slope indicate that penetration into the ice-rich layer at the top of permafrost has occurred over the past decade. Active-layer thickness values from the 1960s are generally higher than those from the 1990s, and are very similar to those of the 2000s. Analysis of spatial active-layer observations at representative locations demonstrates significant variations in active-layer thickness between different landscape types, reflecting the influence of vegetation, substrate, microtopography, and, especially, soil moisture. Landscape-specific differences exist in the response of active-layer thickness to climatic forcing. These differences are attributable to the existence of localized controls related to combinations of surface and subsurface characteristics. The geocryological records at Barrow illustrate the importance and effectiveness of sustained, well organized monitoring efforts to document long-term trends.
Resumo:
Bidirectional DC-DC converters are widely used in different applications such as energy storage systems, Electric Vehicles (EVs), UPS, etc. In particular, future EVs require bidirectional power flow in order to integrate energy storage units into smart grids. These bidirectional power converters provide Grid to Vehicle (V2G)/ Vehicle to Grid (G2V) power flow capability for future EVs. Generally, there are two control loops used for bidirectional DC-DC converters: The inner current loop and The outer loop. The control of DAB converters used in EVs are proved to be challenging due to the wide range of operating conditions and non-linear behavior of the converter. In this thesis, the precise mathematical model of the converter is derived and non-linear control schemes are proposed for the control system of bidirectional DC-DC converters based on the derived model. The proposed inner current control technique is developed based on a novel Geometric-Sequence Control (GSC) approach. The proposed control technique offers significantly improved performance as compared to one for conventional control approaches. The proposed technique utilizes a simple control algorithm which saves on the computational resources. Therefore, it has higher reliability, which is essential in this application. Although, the proposed control technique is based on the mathematical model of the converter, its robustness against parameter uncertainties is proven. Three different control modes for charging the traction batteries in EVs are investigated in this thesis: the voltage mode control, the current mode control, and the power mode control. The outer loop control is determined by each of the three control modes. The structure of the outer control loop provides the current reference for the inner current loop. Comprehensive computer simulations have been conducted in order to evaluate the performance of the proposed control methods. In addition, the proposed control have been verified on a 3.3 kW experimental prototype. Simulation and experimental results show the superior performance of the proposed control techniques over the conventional ones.