975 resultados para Abdominal aorta
Resumo:
Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.
Resumo:
Background: Although smokers tend to have a lower body-mass index (BMI) than non-smokers, smoking may affect body fat (BF) distribution. Some studies have assessed the association between smoking, BMI and waist circumference (WC), but, to our knowledge, no population-based studies assessed the relation between smoking and BF composition. We assessed the association between amount of cigarette smoking, BMI, WC and BF composition. Method: Data was analysed from a cross-sectional population-based study including 6'187 Caucasians aged 32-76 and living in Switzerland. Height, weight and WC were measured. BF, expressed in percent of total body weight, was measured by electrical bioimpedance. Abdominal obesity was defined as a WC 0102 cm for men and 088 cm for women and normal WC as <94 cm for men and <80 cm for women. In men, excess BF was defined as %BF 028.1, 28.7, 30.6 and 32.6 for age groups 32-44, 45-54, 55-64 and 65-76, respectively; the corresponding values for women were 35.9, 36.5, 40.5 and 44.4. Cigarette smoking was assessed using a self-reported questionnaire. Results: 29.3% of men and 25.0% of women were smokers. Prevalence of obesity, abdominal obesity, and excess of BF was 16.9% and 26.6% and 14.2% in men and 15.0%, 33.0% and 27.5% in women, respectively. Smokers had lower age-adjusted mean WC and percent of BF compared to non-smokers. However, among smokers, mean age-adjusted WC and BF increased with the number of cigarettes smoked per day: among light (1-10 cig/day), moderate (11-20) and heavy smokers (>20), mean ± SE %BF was 22.4 ± 0.3, 23.1 ± 0.3 and 23.5 ± 0.4 for men, and 31.9 ± 0.3, 32.6 ± 0.3 and 32.9 ± 0.4 for women, respectively. Mean WC was 92.9 ± 0.6, 94.0 ± 0.5 and 96.0 ± 0.6 cm for men, and 80.2 ± 0.5, 81.3 ± 0.5 and 83.3 ± 0.7 for women, respectively. Compared with light smokers, the age-adjusted odds ratio (95% Confidence Interval) for excess of BF was 1.04 (0.58 to 1.85) for moderate smokers and 1.06 (0.57 to 1.99) for heavy smokers in men (p-trend = 0.9), and 1.35 (0.92 to 1.99) and 2.26 (1.38 to 3.72), respectively, in women (p-trend = 0.04). Odds ratio for abdominal obesity vs. normal WC was 1.32 (0.81 to 2.15) for moderate smokers and 1.95 (1.16 to 3.27) for heavy smokers in men (p-trend <0.01), and 1.15 (0.79 to 1.69) and 2.36 (1.41 to 3.93) in women (p-trend = 0.03). Conclusion: WC and BF were positively and dose-dependently associated with the number of cigarettes smoked per day in women, whereas only WC was dose dependently and significantly associated with the amount of cigarettes smoked per day in men. This suggests that heavy smokers, especially women, are more likely to have an excess of BF and to accumulate BF in the abdomen compared to lighter smokers.
Resumo:
ABSTRACT: BACKGROUND: Although smokers tend to have a lower body-mass index than non-smokers, smoking may favour abdominal body fat accumulation. To our knowledge, no population-based studies have assessed the relationship between smoking and body fat composition. We assessed the association between cigarette smoking and waist circumference, body fat, and body-mass index. METHODS: Height, weight, and waist circumference were measured among 6,123 Caucasians (ages 35-75) from a cross-sectional population-based study in Switzerland. Abdominal obesity was defined as waist circumference>=102 cm for men and >=88 cm for women. Body fat (percent total body weight) was measured by electrical bioimpedance. Age- and sex-specific body fat cut-offs were used to define excess body fat. Cigarettes smoked per day were assessed by self-administered questionnaire. Age-adjusted means and odds ratios were calculated using linear and logistic regression. RESULTS: Current smokers (29% of men and 24% of women) had lower mean waist circumference, body fat percentage, and body-mass index compared with non-smokers. Age-adjusted mean waist circumference and body fat increased with cigarettes smoked per day among smokers. The association between cigarettes smoked per day and body-mass index was non-significant. Compared with light smokers, the adjusted odds ratio (OR) for abdominal obesity in men was 1.28 (0.78-2.10) for moderate smokers and 1.94 (1.15-3.27) for heavy smokers (P=0.03 for trend), and 1.07 (0.72-1.58) and 2.15 (1.26-3.64) in female moderate and heavy smokers, respectively (P<0.01 for trend). Compared with light smokers, the OR for excess body fat in men was 1.05 (95% CI: 0.58-1.92) for moderate smokers and 1.15 (0.60-2.20) for heavy smokers (P=0.75 for trend) and 1.34 (0.89-2.00) and 2.11 (1.25-3.57), respectively in women (P=0.07 for trend). CONCLUSION: Among smokers, cigarettes smoked per day were positively associated with central fat accumulation, particularly in women.
Resumo:
Upon agonist stimulation, endothelial cells trigger smooth muscle relaxation through the release of relaxing factors such as nitric oxide (NO). Endothelial cells of mouse aorta are interconnected by gap junctions made of connexin40 (Cx40) and connexin37 (Cx37), allowing the exchange of signaling molecules to coordinate their activity. Wild-type (Cx40(+/+)) and hypertensive Cx40-deficient mice (Cx40(-/-)), which also exhibit a marked decrease of Cx37 in the endothelium, were used to investigate the link between the expression of endothelial connexins (Cx40 and Cx37) and endothelial nitric oxide synthase (eNOS) expression and function in the mouse aorta. With the use of isometric tension measurements in aortic rings precontracted with U-46619, a stable thromboxane A(2) mimetic, we first demonstrate that ACh- and ATP-induced endothelium-dependent relaxations solely depend on NO release in both Cx40(+/+) and Cx40(-/-) mice, but are markedly weaker in Cx40(-/-) mice. Consistently, both basal and ACh- or ATP-induced NO production were decreased in the aorta of Cx40(-/-) mice. Altered relaxations and NO release from aorta of Cx40(-/-) mice were associated with lower expression levels of eNOS in the aortic endothelium of Cx40(-/-) mice. Using immunoprecipitation and in situ ligation assay, we further demonstrate that eNOS, Cx40, and Cx37 tightly interact with each other at intercellular junctions in the aortic endothelium of Cx40(+/+) mice, suggesting that the absence of Cx40 in association with altered Cx37 levels in endothelial cells from Cx40(-/-) mice participate to the decreased levels of eNOS. Altogether, our data suggest that the endothelial connexins may participate in the control of eNOS expression levels and function.
Resumo:
Angiostrongylus costaricensis is a parasitic nematode of rodents and molluscs are the intermediate hosts. Nocturnal collection of molluscs and search for infective third stage larvae of A. costaricensis was carried out in 18 endemic foci identified by the notification of a confirmed diagnosis in human biopsies or surgical specimens. Molluscs were digested in acidic solution and isolation of larvae eventually present was done in a Baermann funnel. Larvae identified by the presence of a delicate groove in the tail were counted to assess the individual parasitic burden. Four species were found infected, with ranges of prevalence in parenthesis: Phyllocaulis variegatus (7% to 33.3%); Bradybaena similaris (11.7% to 24.1%); Belocaulus angustipes (8.3% ) and Phyllocaulis soleiformis (3.3% to 14.2%). Parasitic burden varied from 1 to 75 with P. variegatus, 1 to 98 with B. similaris, 1 to 13 with B. angustipes and 1 larvae in each of two specimens of P. soleiformis. P. variegatus was present in all sites and was found infected with the highest prevalence figures and the highest individual parasitic burdens. These data stress the importance of veronicellid slugs as intermediate hosts for A. costaricensis in the endemic areas in Rio Grande do Sul, Brazil
Resumo:
Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.
Resumo:
Una de les principals complicacions de la cirurgia de la dissecció aòrtica aguda és el dany neurològic. Entre els principals avenços per a la seva prevenció destaca el canvi de la perfusió arterial retrògrada a anterògrada a través de l’artèria axil•lar, amb la possibilitat de realitzar protecció cerebral. Hipòtesis de treball: L’ús de la canulació arterial axil•lar ha permès reduïr significativament l’incidència de complicacions neurològiques en la cirurgia de la dissecció aguda aòrtica. Material i mètodes: De manera retrospectiva, s’han comparat els pacients intervinguts de dissecció aòrtica aguda al llarg dels últims deu anys. Conclusió principal: L’ús de la canulació arterial axil•lar ha permès reduïr significativament l’incidència de complicacions neurològiques en la cirurgia de la dissecció aòrtica aguda del nostre centre.
Resumo:
Estudi observacional de 60 pacients ingressats a la UCI per patologia extraabdominal, que demostra alta incidència de HIA (90%) i que el valor de PIA màxima és marcador pronòstic del SCA però no prediu mortalitat. Els graus més elevats d’HIA s’associen amb VMI, shock, SDRA, insuficiència renal e ili. La PIA màxima del pacient crític no neurològic (sèptic, traumatològic i respiratori) és més elevada que la del no neurològic, 20 i 16 mmHg respectivament. El valor de PIA màxima que millor prediu insuficiència renal al pacient no neurològic és 18,5mmHg. La PIA màxima es correlaciona amb l’estada a UCI i hospitalària.
Resumo:
Angiostrongylus costaricensis may cause intestinal lesions of varied severity when it accidentally infects man in Central and South America. First-stage larvae have never been detected in stools. Therefore, a parasite-specific IgG ELISA was evaluated for the determination of the acute phase of infection. The specificity and the sensitivity of the immunoassay was shown to be 76.2% and 91.1%, respectively. Eight serum samples taken from patients with histopathological diagnosis, at different time points (3 to 15 months) after surgical treatment, showed a sharp and early decline in antibody reactivity. The titration of anti-A. costaricensis antibodies has proved to be a useful method for the diagnosis of acute abdominal angiostrongyliasis.
Resumo:
Els pacients amb patologia abdominal aguda poden desenvolupar una insuficiència respiratòria secundària a la resposta inflamatòria generada o a una pneumònia nosocomial. El mesurament del “soluble *triggering receptor expressed on myeloid cells 1” (sTREM-1) en líquid alveolar, pleural, sinovial o cefalorraquidi ha demostrat la seva utilitat en el diagnòstic d'infecció. Es va determinar el sTREM-1 alveolar i peritoneal en pacients amb quadre abdominal agut més síndrom de distress respiratori agut (SDRA). Es va concloure que el sTREM-1 és útil per diagnosticar infeccions abdominals i pulmonars en aquests pacients i que la relació sTREM-1 alveolar/peritoneal podria ser útil per determinar el focus infecciós.
Resumo:
En aquest estudi, s'ha intentat determinar si l'aplicació de contrast intravenós augmenta la rendibilitat de l'ecografia abdominal en l'estudi de la recurrència postquirúrgica de la malaltia de Crohn (EC). Per a això vam estudiar 40 pacients que complien uns determinats criteris d'inclusió, als quals se'ls va realitzar una colonoscopia (gold standar) i una ecografia abdominal (EA) amb contrast intravenós. Després d'analitzar els resultats, podem concloure, que l'ocupació de contrast durant la realització de l'ecografia abdominal permet augmentar la capacitat diagnòstica de la recurrència endoscópica en pacients amb EC i resecció intestinal, no obstant això la seva utilitat és menor per a valorar la gravetat de la recurrència
Resumo:
In this work we present numerical simulations of continuous flow left ventricle assist device implantation with the aim of comparing difference in flow rates and pressure patterns depending on the location of the anastomosis and the rotational speed of the device. Despite the fact that the descending aorta anastomosis approach is less invasive, since it does not require a sternotomy and a cardiopulmonary bypass, its benefits are still controversial. Moreover, the device rotational speed should be correctly chosen to avoid anomalous flow rates and pressure distribution in specific location of the cardiovascular tree. With the aim of assessing the differences between these two approaches and device rotational speed in terms of flow rate and pressure waveforms, we set up numerical simulations of network of one-dimensional models where we account for the presence of an outflow cannula anastomosed to different locations of the aorta. Then, we use the resulting network to compare the results of the two different cannulations for several stages of heart failure and different rotational speed of the device. The inflow boundary data for the heart and the cannulas are obtained from a lumped parameters model of the entire circulatory system with an assist device, which is validated with clinical data. The results show that ascending and descending aorta cannulations lead to similar waveforms and mean flow rate in all the considered cases. Moreover, regardless of the anastomosis region, the rotational speed of the device has an important impact on wave profiles; this effect is more pronounced at high RPM.