947 resultados para ANTICOAGULANT CITRATE-DEXTROSE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The year 2014 was rich in significant advances in all areas of internal medicine. Many of them have an impact on our daily practice and on the way we manage one problem or another. From the use of the ultrasound for the diagnosis of pneumonia to the choice of the site of venous access and the type of line, and the increasing complexity of choosing an oral anticoagulant agent, this selection offers to the readers a brief overview of the major advances. The chief residents in the Service of internal medicine of the Lausanne University hospital are pleased to share their readings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Venous thromboembolism (VTE) carries a considerable risk of recurrence and anticoagulants should be administered for a minimum of three months. Since little is known about real life management of VTE, we aimed to describe current practice in the secondary prevention of VTE. MATERIALS AND METHODS: Using the database of an international, prospective registry on patients treated for VTE, RIETE, information was collected on risk factors for VTE and bleeding, anticoagulant treatment, and clinical outcomes during follow up. Multivariate analysis using logistic regression was performed to identify predictors of treatment duration. RESULTS: Of 6944 patients with a first episode of VTE 41.1% had unprovoked VTE, 31.8% had transient risk factors, 27.1% had cancer. After the exclusion of patients who died during the first year of observation, the rate of patients treated for >12 months was 55.1%, 41.9%, and 43.2%, respectively (p<0.001). Pulmonary embolism at presentation, recurrence while on treatment, chronic heart failure and age >65 years were independently associated with treatment for >12 months. Body weight <75 kg, anemia, cancer, and the presence of transient risk factors were associated with treatment for 12 months or less. Major bleeding occurred more frequently than recurrent VTE in patients with VTE secondary to transient risk factors and cancer; fatal bleeding was more frequent than fatal recurrent PE in all subgroups. CONCLUSIONS: We observed heterogeneous duration of anticoagulant treatment for the secondary prevention of VTE. A substantial proportion of patients, in particular those with VTE secondary to transient risk factors, may be exposed to a possibly unnecessary risk of bleeding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Reference intervals for many laboratory parameters determined in 24-h urine collections are either not publicly available or based on small numbers, not sex specific or not from a representative sample. METHODS: Osmolality and concentrations or enzymatic activities of sodium, potassium, chloride, glucose, creatinine, citrate, cortisol, pancreatic α-amylase, total protein, albumin, transferrin, immunoglobulin G, α1-microglobulin, α2-macroglobulin, as well as porphyrins and their precursors (δ-aminolevulinic acid and porphobilinogen) were determined in 241 24-h urine samples of a population-based cohort of asymptomatic adults (121 men and 120 women). For 16 of these 24 parameters creatinine-normalized ratios were calculated based on 24-h urine creatinine. The reference intervals for these parameters were calculated according to the CLSI C28-A3 statistical guidelines. RESULTS: By contrast to most published reference intervals, which do not stratify for sex, reference intervals of 12 of 24 laboratory parameters in 24-h urine collections and of eight of 16 parameters as creatinine-normalized ratios differed significantly between men and women. For six parameters calculated as 24-h urine excretion and four parameters calculated as creatinine-normalized ratios no reference intervals had been published before. For some parameters we found significant and relevant deviations from previously reported reference intervals, most notably for 24-h urine cortisol in women. Ten 24-h urine parameters showed weak or moderate sex-specific correlations with age. CONCLUSIONS: By applying up-to-date analytical methods and clinical chemistry analyzers to 24-h urine collections from a large population-based cohort we provide as yet the most comprehensive set of sex-specific reference intervals calculated according to CLSI guidelines for parameters determined in 24-h urine collections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Autologous blood transfusion (ABT) efficiently increases sport performance and is the most challenging doping method to detect. Current methods for detecting this practice center on the plasticizer di(2-ethlyhexyl) phthalate (DEHP), which enters the stored blood from blood bags. Quantification of this plasticizer and its metabolites in urine can detect the transfusion of autologous blood stored in these bags. However, DEHP-free blood bags are available on the market, including n-butyryl-tri-(n-hexyl)-citrate (BTHC) blood bags. Athletes may shift to using such bags to avoid the detection of urinary DEHP metabolites. STUDY DESIGN AND METHODS: A clinical randomized double-blinded two-phase study was conducted of healthy male volunteers who underwent ABT using DEHP-containing or BTHC blood bags. All subjects received a saline injection for the control phase and a blood donation followed by ABT 36 days later. Kinetic excretion of five urinary DEHP metabolites was quantified with liquid chromatography coupled with tandem mass spectrometry. RESULTS: Surprisingly, considerable levels of urinary DEHP metabolites were observed up to 1 day after blood transfusion with BTHC blood bags. The long-term metabolites mono-(2-ethyl-5-carboxypentyl) phthalate and mono-(2-carboxymethylhexyl) phthalate were the most sensitive biomarkers to detect ABT with BTHC blood bags. Levels of DEHP were high in BTHC bags (6.6%), the tubing in the transfusion kit (25.2%), and the white blood cell filter (22.3%). CONCLUSIONS: The BTHC bag contained DEHP, despite being labeled DEHP-free. Urinary DEHP metabolite measurement is a cost-effective way to detect ABT in the antidoping field even when BTHC bags are used for blood storage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A natural clay from Campina Grande region (Paraíba, Brazil), with 8.57% of Fe2O3, was used to study the most appropriate condition to carry out the iron extraction, without altering the clay structure in a significant way. Samples were treated with the Dithionite-Citrate-Bicarbonate method (DCB) for 30 and 120 minutes (pH=9.1), and also with citric acid (pH=1.8; time=15min), at 75°C. Conductivity measurements, X-ray fluorescence, X-ray diffraction, energy-dispersive spectrometry, electron-diffraction with transmission electron microscopy and textural evaluation by nitrogen adsorption were done. The treatment in a basic medium was more selective for iron removal than in acid condition. The time of 30 minutes, with 1.6 g Na2S2O4/10 g clay, was the best condition for the iron extraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A differential pulse polarographic study with the objective to determine iron (III) in presense of copper (II) in a supporting electrolyte based on citrate - EDTA was made. The best experimental conditions found were a supporting electrolyte of citrate 0.25 mol L-1, EDTA 0.050 mol L-1 and KNO3 0.50 mol L-1, pH 5.00. In this media iron (III) showed a polarographic peak in -0.08 V and the copper (II) in -0.34 V, both vs. Ag/AgCl (saturated KCl). Thus, a analytical method was developed and applied to determine iron (III) in brass alloy, a matrix were copper is in large excess over iron. The results obtained showed no interference of copper in the iron determination. The value of 0.21% of iron in the sample alloy composition was obtained and the method was validated by atomic absortion and recovery test, and the results exhibited a good agreement with the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cyclic voltammetry was used to study 3,4-dihydroxybenzaldehyde (3,4-DHB) electropolymerization processes on carbon paste electrodes. The characteristics of the electropolymerized films were highly dependent on pH, anodic switching potential, scan rate, 3,4-DHB concentrations and number of cycles. Film stability was determined in citrate/phosphate buffer solutions at the same pH used during the electropolymerization process. The best conditions to prepare carbon paste modified electrodes were pH 7.8; 0.0 <= Eapl <= 0.25 V; 10 mV s-1; 0.25 mmol L-1 3,4-DHB and 10 scans. These carbon paste modified electrodes were used for NADH catalytic detection at 0.23 V in the range 0.015 <= [NADH] <= 0.21 mmol L-1. Experimental data were used to propose a mechanism for the 3,4--DHB electropolymerization processes, which involves initial phenoxyl radical formation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Samples of natural clay composed by kaolinite, illite, goethite and quartz, were calcinated and submitted to lixiviation with citrate and chloridric acid in order to remove iron. Investigation due to extraction consequences was carried cut by analyzing its acid properties using ammonia gas as probe in infrared spectrophotometry analysis. The sample that were treated with citrate followed by acid lixiviation yield materials twice more acid than samples treated with acid only.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work describes a new procedure for cetylpyridinium chloride determination in oral disinfectants, based on a flow-injection system with potentiometric detection. The determination was based on the measurement of picrate concentration decrease as result of ion-pair reaction with the analyte present in the injected sample. In the optimised set-up the sample injection volume was kept at 400 µL and merged downstream with the reagent solution containing 1,0 x10-5 mol/L of picrate adjusted to pH 5.0 with citrate/citric acid buffer. The flow rate was fixed at 8 mL/min and the reactor length at 40 cm. The proposed procedure enables the determination of cetylpyridinium in the analytical range of 5,0x10-6 - 7,5x10-5 mol/L at a sampling rate of 60/h. The results for real samples had a precision better than 3% and were comparable to the labelled values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two high performance liquid chromatography (HPLC) methods for the quantitative determination of indinavir sulfate were tested, validated and statistically compared. Assays were carried out using as mobile phases mixtures of dibutylammonium phosphate buffer pH 6.5 and acetonitrile (55:45) at 1 mL/min or citrate buffer pH 5 and acetonitrile (60:40) at 1 mL/min, an octylsilane column (RP-8) and a UV spectrophotometric detector at 260 nm. Both methods showed good sensitivity, linearity, precision and accuracy. The statistical analysis using the t-student test for the determination of indinavir sulfate raw material and capsules indicated no statistically significant difference between the two methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Maltodextrin was produced from cassava and corn starch by enzymatic hydrolysis with alpha-amylase. The cassava starch hydrolysis rate was higher than that of corn starches in maltodextrin production with shorter dextrose equivalent (DE). DE values do not show directly the nature of the obtained oligosaccharides. Maltodextrin produced from cassava and corn starch was analysed by high performance liquid chromatography (HPLC), and the analysis showed that maltodextrin production differs according to the source of the starch. This is important in defining the application of the maltodextrin, according to its desired function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study on optimization of bath parameters for electrodeposition of Fe-W-B alloys from plating baths containing ammonia and citrate is reported. A 2³ full factorial design was successfully employed for experimental design analysis of the results. The corrosion resistance and amorphous character were evaluated. The bath conditions obtained for depositing the alloy with good corrosion resistance were: 0.01 M iron sulfate, 0.10 M sodium tungstate and 0.60 M ammonium citrate. The alloy was deposited at 12% current efficiency. The alloy obtained had Ecorr -0.841 V and Rp 1.463 x 10(4) Ohm cm². The deposit obtained under these conditions had an amorphous character and no microcracks were observed on its surface. Besides this, the bath conditions obtained for depositing the alloy with the highest deposition efficiency were: 0.09 M iron sulfate, 0.30 M sodium tungstate and 0.50 M ammonium citrate. The alloy was deposited at 50% current efficiency, with an average composition of 34 wt% W, 66 wt% Fe and traces of boron. The alloy obtained had Ecorr -0.800 V and Rp 1.895 x 10³ Ohm cm². Electrochemical corrosion tests verified that the Fe-W-B alloy deposited under both conditions had better corrosion resistance than Fe-Mo-B.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The solubility of Mn in different fertilizers (MnSO4.H2O-p.a., MnO2-p.a.+MnO-Ind., MnO2-Ind.+MnO-Ind., MnO2-p.a., MnO2-Ind. and MnO-Ind.) was determined using different methodologies: total content and soluble contents in water, 10% H2SO4, citric acid at 20 g L-1, diluted neutral ammonium citrate, (1+9) and DTPA at 0.005 mol L-1. The Mn solubilities in the latter three extractors were assessed after agitation of the sample for one hour and after boiling for 5 minutes. The extraction procedure using neutral ammonium citrate (1+9), at 1:100, with agitation for one hour, was shown to be the most adequate to assess the availability of Mn in fertilizers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a simple and rapid spectrophotometric method for quantitative determination of sildenafil citrate based on its reaction with p-chloranil accelerated by hydrogen peroxide, producing a stable purple compound (λmax= 535 nm). In the absence of peroxide this reaction is very slow. The experimental conditions were optimized by using response surface methodologies. Beer's law is obeyed in a concentration range of 8.52 x 10-5 - 1.70 x 10-3 mol L-1 (r = 0.999). The detection limit was 1.96 x 10-5 mol L-1. The method was successfully applied for the determination of sildenafil citrate in medicines with good accuracy and precision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A prospective study of IgG and IgM isotypes of anticardiolipin antibodies (aCL) in a series of 100 patients with systemic lupus erythematosus was carried out. To determine the normal range of both isotype titres a group of 100 normal control serum samples was studied and a log-normal distribution of IgG and IgM isotypes was found. The IgG anticardiolipin antibody serum was regarded as positive if a binding index greater than 2.85 (SD 3.77) was detected and a binding index greater than 4.07 (3.90) was defined as positive for IgM anticardiolipin antibody. Twenty four patients were positive for IgG aCL, 20 for IgM aCL, and 36 for IgG or IgM aCL, or both. IgG aCL were found to have a significant association with thrombosis and thrombocytopenia, and IgM aCL with haemolytic anaemia and neutropenia. Specificity and predictive value for these clinical manifestations increased at moderate and high anticardiolipin antibody titres. In addition, a significant association was found between aCL and the presence of lupus anticoagulant. Identification of these differences in the anticardiolipin antibody isotype associations may improve the clinical usefulness of these tests, and this study confirms the good specificity and predictive value of the anticardiolipin antibody titre for these clinical manifestations.