911 resultados para urine reagent strip


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The solvent has a significant influence in the rate of reactions promoted by Stryker's reagent The reactions performed in THF were, in most cases, faster than in toluene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to develop a new enzymeless electroanalytical method for the indirect quantification of creatinine from urine sample. This method is based on the electrochemical monitoring of picrate anion reduction at a glassy carbon electrode in an alkaline medium before and after it has reacted with creatinine (Jaffe's reaction). By using the differential pulse voltammetry technique under the optimum experimental conditions (step potential, amplitude potential, reaction time, and temperature), a linear analytical curve was obtained for concentrations of creatinine ranging from 1 to 80 mu mol L-1, with a detection limit of 380 nmol L-1. This proposed method was used to measure creatinine in human urine without the interference of most common organic species normally present in biological fluids (e.g., uric acid, ascorbic acid, glucose, and phosphocreatinine). The results obtained using urine samples were highly similar to the results obtained using the reference spectrophotometric method (at a 95% confidence level). (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background Sequential physicochemical alterations in blood and urine in the course of acute kidney injury (AKI) development have not been previously described. We aimed to describe these alterations in parallel to traditional renal and acid–base parameters. Methods One hundred and sixty eight consecutive critically ill patients with no previous kidney disease, who had an indwelling urinary catheter at ICU admission and who remained with the catheter for at least two days without dialysis were included. A sample of blood and spot urine were collected simultaneously, once daily, until catheter removal or dialysis requirement. Traditional acid–base and renal parameters were sequentially evaluated in parallel to blood and urinary physicochemical parameters. Patients were classified during this period as having or not AKI and, for patients with AKI, duration (transient or persistent) and severity (creatinine-based AKIN stage) were evaluated. Results One hundred and thirteen patients (67.3%) had AKI: 92 at ICU admission and 21 during the observation period. AKI development was characterized in blood by increased values of phosphate and unmeasured anions (SIG), decreased albumin, and in urine by decreased values of sodium (NaU), chloride (ClU) as well as high urinary strong ion difference (SIDu). These alterations began to occur before AKI diagnosis, and they reverted in transient AKI but remained in persistent AKI. NaU, ClU and albumin decreased, and phosphate, SIG and SIDu increased with AKI severity progression. NaU and ClU values increased again when AKIN stage 3 was reached. Conclusions Simultaneous physicochemical analysis of blood and urine revealed standardized alterations that characterize AKI development in critically ill patients. These alterations paralleled AKI duration and severity. Future studies should consider including sequential evaluation of urine biochemistry as part of the armamentarium for AKI diagnosis and management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the prevalence of the urinary excretion of BKV and JCV in HIV-infected patients without neurological symptoms. METHODS: Urine samples from HIV-infected patients without neurological symptoms were tested for JC virus and BK virus by PCR. Samples were screened for the presence of polyomavirus with sets of primers complementary to the early region of JCV and BKV genome (AgT). The presence of JC virus or BK virus were confirmed by two other PCR assays using sets of primers complementary to the VP1 gene of each virus. Analysis of the data was performed by the Kruskal-Wallis test for numerical data and Pearson or Yates for categorical variables. RESULTS: A total of 75 patients were included in the study. The overall prevalence of polyomavirus DNA urinary shedding was 67/75 (89.3%). Only BKV DNA was detected in 14/75 (18.7%) urine samples, and only JCV DNA was detected in 11/75 (14.7%) samples. Both BKV and JCV DNA were present in 42/75 (56.0%) samples. CONCLUSION: In this study we found high rates of excretion of JCV, BKV, and simultaneous excretion in HIV+ patients. Also these results differ from the others available on the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix metalloproteinases (MMP) are a large family of proteinases that remodel extracellular matrix (ECM) component. Recent data suggest a role for MMPs in a number of renal pathophysiologies, associated with an imbalance of ECM syntesis and degradation, which may result in an accumulation of ECM molecules and renal fibrosis. The aim of this study is to elucidate the role of pro and activated MMP-2 and 9 in urine and renal tissue of healty and nephropatic dogs. Renal tissue of 8 healty dogs and either renal tissue and urine of 9 nephropatic dogs was collected and analize using zimographic method, which is been validated in this study. Either MMPs zimographic bands were present in almost all samples. In particular, pro and activated MMP-9 zimographic bands were poorly represent in renal tissue of healty dogs, whereas were very represent in nephropatic dogs. Pro and activated MMP-2 was present in either tissue of healty and nephropatic dogs. In urine of nephropatic dogs, pro and activated MMP-9 was more evident than MMP-2, but there was not correlaction with renal tissue levels, therefore urine levels of MMPs have poorly usefulness in diagnostic pratice. The values of Pro and activated MMP-9 in nephropatic dogs were significantly higher compared with normal dogs (p < 0,05), whereas there was not statistically meaningful for Pro and activated MMP-2. In conclusion, in this study we have validated a zimographic method for renal tissue of dogs and we have illustrated the changes in nephropatic dogs, which may be useful for further study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urine is considered an ideal source of biomarkers, however in veterinary medicine a complete study on the urine proteome is still lacking. The present work aimed to apply proteomic techniques to the separation of the urine proteome in dogs, cats, horses, cows and some non-conventional species. High resolution electrophoresis (HRE) was also validated for the quantification of albuminuria in dogs and cats. In healthy cats, applying SDS-PAGE and 2DE coupled to mass spectrometry (MS), was produced a reference map of the urine proteome. Moreover, 13 differentially represented urine proteins were linked with CKD, suggesting uromodulin, cauxin, CFAD, Apo-H, RBP and CYSM as candidate biomarkers to be investigated further. In dogs, applying SDS-PAGE coupled to MS, was highlighted a specific pattern in healthy animals showing important differences in patients affected by leishmaniasis. In particular, uromodulin could be a putative biomarker of tubular damage while arginine esterase and low MW proteins needs to be investigated further. In cows, applying SDS-PAGE, were highlighted different patterns between heifers and cows showing some interesting changes during pregnancy. In particular, putative alpha-fetoprotein and b-PAP needs to be further investigated. In horses, applying SDS-PAGE, was produced a reference profile characterized by 13±4 protein bands and the most represented one was the putative uromodulin. Proteinuric horses showed the decrease of the putative uromodulin band and the appearance of 2 to 4 protein bands at higher MW and a greater variability in the range of MW between 49 and 17 kDa. In felids and giraffes was quantified proteinuria reporting the first data for UTP and UPC. Moreover, by means of SDS-PAGE, were highlighted species-specific electrophoretic patterns in big felids and giraffes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In abstinence maintenance programs, for reissuing the driving licence and in workplace monitoring programs abstinence from ethanol and its proof are demanded. Various monitoring programs that mainly use ethyl glucuronide (EtG) as alcohol consumption marker have been established. To abstain from ethanol, but not from the taste of alcoholic beverages, in particular non-alcoholic beer has become more and more popular. In Germany, these "alcohol-free" beverages may still have an ethanol content of up to 0.5vol.% without the duty of declaration. Due to severe negative consequences resulting from positive EtG tests, a drinking experiment with 2.5L of non-alcoholic beer per person was performed to address the question of measurable concentrations of the direct metabolites EtG and EtS (ethyl sulphate) in urine and blood. Both alcohol consumption markers - determined by LC-MS/MS - were found in high concentrations: maximum concentrations in urine found in three volunteers were EtG 0.30-0.87mg/L and EtS 0.04-0.07mg/L, i.e., above the often applied cut-off value for the proof of abstinence of 0.1mg EtG/L. In the urine samples of one further volunteer, EtG and EtS concentrations cumulated over-night and reached up to 14.1mg/L EtG and 16.1mg/L EtS in the next morning's urine. Ethanol concentrations in blood and urine samples were negative (determined by HS-GC-FID and by an ADH-based method).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metabolite identification and metabolite profiling are of major importance in the pharmaceutical and clinical context. However, highly polar and ionic substances are rarely included as analytical tools are missing. In this study, we present a new method for the determination of urinary sulfates, sulfonates, phosphates and other anions of strong acids. The method comprises a CE separation using an acidic BGE (pHurine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of a semiquantitative commercially available test based on DNA-strip technology (microIDent®, Hain Lifescience, Nehren, Germany) on diagnosis and treatment of severe chronic periodontitis of 25 periodontitis patients was evaluated in comparison with a quantitative in-house real-time PCR. Subgingival plaque samples were collected at baseline as well as at 3, 6, and 12 months later. After extracting DNA, Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola, and several other periodontopathogens were determined by both methods. The results obtained by DNA-strip technology were analyzed semiquantitatively and additionally quantitatively by densitometry. The results for the 4 major periodontopathogenic bacterial species correlated significantly between the 2 methods. Samples detecting a high bacterial load by one method and negative by the other were always found in less than 2% of the total samples. Both technologies showed the impact of treatment on microflora. Especially the semiquantitative DNA-strip technology clearly analyzed the different loads of periodontopathogens after therapy and is useful in microbial diagnostics for patients in dental practices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are direct alcohol consumption markers widely used nowadays for clinical and forensic applications. They are detectable in blood and urine even after consumption of trace amounts of ethanol and for a longer time frame, being detectable even when no more ethanol is present. The instability of EtG against bacterial degradation in contaminated urine samples and/or the possible postcollection synthesis of this metabolite in samples containing, e.g., Escherichia coli and ethanol, may cause false identification of alcohol uptake. Therefore, it is of paramount importance to constrict these error sources by inhibition of any bacterial growth causing hydrolization or synthesis of EtG. This study evaluates a new method of collecting urine samples on filter paper, dried urine spots (DUS), for simultaneous detection of EtG, EtS and creatinine, having the great advantage of inhibiting bacterial activity. In addition, a method validation for the determination of EtG and EtS in DUS was performed according to the FDA guidelines. Sterile-filtered urine was spiked with EtG and EtS, inoculated with E. coli and incubated. Liquid and dried urine samples were collected after various time intervals up to 96 h. Liquid samples were frozen immediately after collection, whereas aliquots for DUS were pipetted onto filter paper, allowed to dry and stored at RT until analysis 1 week after. The specimens were analyzed by LC-ESI-MS/MS. As expected, degradation of EtG, but not of EtS, was observed in contaminated liquid urine samples. However, the specimens collected on filter paper and stored at RT showed no degradation during storage. Therefore, collecting urine samples on filter paper for EtG and EtS analysis turns out to be a reliable method to avoid bacterial degradation of EtG and EtS, and consequently, stabilization of these ethanol metabolites is achieved. In addition, simultaneous measurement of creatinine content as an indicator of urine dilution helps to interpret the results. Method validation for EtG and EtS in DUS was satisfactory, showing the linearity of the calibration curves in the studied concentration range, good precision, accuracy and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the development and prognosis of alcohol-induced liver disease (ALD) vary significantly with genetic background, identification of a genetic background-independent noninvasive ALD biomarker would significantly improve screening and diagnosis. This study explored the effect of genetic background on the ALD-associated urinary metabolome using the Ppara-null mouse model on two different backgrounds, C57BL/6 (B6) and 129/SvJ (129S), along with their wild-type counterparts. Reversed-phase gradient UPLC-ESI-QTOF-MS analysis revealed that urinary excretion of a number of metabolites, such as ethylsulfate, 4-hydroxyphenylacetic acid, 4-hydroxyphenylacetic acid sulfate, adipic acid, pimelic acid, xanthurenic acid, and taurine, were background-dependent. Elevation of ethyl-β-d-glucuronide and N-acetylglycine was found to be a common signature of the metabolomic response to alcohol exposure in wild-type as well as in Ppara-null mice of both strains. However, increased excretion of indole-3-lactic acid and phenyllactic acid was found to be a conserved feature exclusively associated with the alcohol-treated Ppara-null mouse on both backgrounds that develop liver pathologies similar to the early stages of human ALD. These markers reflected the biochemical events associated with early stages of ALD pathogenesis. The results suggest that indole-3-lactic acid and phenyllactic acid are potential candidates for conserved and pathology-specific high-throughput noninvasive biomarkers for early stages of ALD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CZE coupled to sheath liquid-based electrospray ionization (ESI) and multiple-stage ion trap mass spectrometry (MS(n) ) was used for the confirmation analysis of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in human serum and urine collected after intake of alcoholic beverages. Electrophoretic separations were performed in uncoated fused-silica capillaries using a pH 9.5 ammonium acetate background electrolyte and normal polarity. MS detection of EtG and EtS occurred after negative ionization using a spray liquid containing 0.5% v/v ammonia in isopropanol/water (60:40%, v/v). CZE-MS and CZE-MS² results obtained after injection of solid-phase extracts for EtG and EtS and of diluted urine confirmed the presence of EtG and EtS in samples whose levels were previously determined by CZE with indirect UV detection. Detection limits of each compound were estimated to be around 2.0 (injection of diluted urine) and 0.2 μg/mL (extracts).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the correlation between three strip-type, colorimetric tests and two laboratory methods with respect to the analysis of salivary buffering. The strip-type tests were saliva-check buffer, Dentobuff strip and CRT(®) Buffer test. The laboratory methods included Ericsson's laboratory method and a monotone acid/base titration to create a reference scale for the salivary titratable acidity. Additionally, defined buffer solutions were prepared and tested to simulate the carbonate, phosphate and protein buffer systems of saliva. The correlation between the methods was analysed by the Spearman's rank test. Disagreement was detected between buffering capacity values obtained with three strip-type tests that was more pronounced in case of saliva samples with medium and low buffering capacities. All strip-type tests were able to assign the hydrogencarbonate, di-hydrogenphosphate and 0.1% protein buffer solutions to the correct buffer categories. However, at 0.6% total protein concentrations, none of the test systems worked accurately. Improvements are necessary for strip-type tests because of certain disagreement with the Ericsson's laboratory method and dependence on the protein content of saliva.