965 resultados para transmission electron microscope methods
OBSERVATIONS on ETCHED ENAMEL IN NON-ERUPTED DECIDUOUS MOLARS: A SCANNING ELECTRON MICROSCOPIC STUDY
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We present evidences that ultrastructural electron microscope findings are valuable ways to understand the in vitro regeneration process, in particular in the yellow passion fruit. Shoot-regeneration was induced in hypocotyl and leaf-derived explants using 4.44 mu M BAP, and the entire organogenic process was analyzed using conventional histology, scanning and transmission electronic microscopy. Both direct and indirect regeneration modes were observed in hypocotyl explants, but only direct regeneration occurred in leaf-derived cultures. In the direct pathway from both explant types, meristemoids developed into globular structures, here called protuberances. The peripheral meristematic layers of the protuberances displayed ultrastructural characteristics indicative of a high metabolic activity, and only these cells originated shoots and leaf primordia, the latter being frequent when leaf explants were used. Moreover, the peripheral cells of the protuberances derived from leaf explants lost adhesion during the culture, diminishing the regeneration rates. We recommend the use of hypocotyls as a source of explant to obtain shoots as well as a genetic transformation system for the yellow passion fruit. However, the direct pathway is preferred because a type of amitosis occurred in the peripheral cells of hypocotyl-derived calli, which has the potential to result in genetic instability of the regenerating plants/tissue.
Resumo:
Aim To evaluate in vitro the cleaning of root-canal walls after irrigation with different irrigants.Methodology A total of 36 recently extracted human teeth were divided into four experimental groups according to the irrigating solution used: saline; 2% chlorhexidine; 2.5% sodium hypochlorite; and 2.5% sodium hypochlorite + EDTA. The cleaning of the apical, middle and coronal thirds of the root canals was evaluated by scanning electron microscope examination using a 4-point scoring system.Results the best cleaning was obtained using 2.5% sodium hypochlorite and EDTA, followed by 2.5% sodium hypochlorite only (P < 0.05), whose cleaning was similar to chlorhexidine only in the cervical third. Cleaning by saline and 2% chlorhexidine was worse than the other two groups and was similar in all thirds. Better cleaning was found in the cervical and middle thirds for all groups with the worst results in the apical third.Conclusions the apical third of the root canals was not cleaned as well as the middle and coronal thirds. Cleaning by chlorhexidine and saline was inferior compared to the cleaning by sodium hypochlorite with and without EDTA.
Resumo:
Statement of problem. The success of metal-ceramic restorations is influenced by the compatibility between base metal alloys and porcelains. Although porcelain manufacturers recommend their own metal systems as the most compatible for fabricating metal-ceramic prostheses, a number of alloys have been used.Purpose. This study evaluated the shear bond strength between a porcelain system and 4 alternative alloys.Material and methods. Two Ni-Cr alloys: 4 ALL and Wiron 99, and 2 Co-Cr alloys: IPS d.SIGN 20 and Argeloy NP were selected for this study. The porcelain (IPS d.Sign porcelain system) portion of the cylindrical inetal-ceramic specimens was 4 mm thick and 4 mm high; the metal portion was machined to 4 x 4 mm, with a base that was 5 nun thick and 1 mm high. Forty-four specimens were prepared (n=11). Ten specimens from each group were subjected to a shear load oil a universal testing machine using a 1 min/min crosshead speed. One specimen from each group was observed with a scanning electron microscope. Stress at failure (MPa) was determined. The data were analyzed with a 1-way analysis of variance (alpha=.05).Results. The groups, all including IPS d.Sign porcelain, presented the following mean bond strengths (+/-SD) in MPa: 4 ALL, 54.0 +/- 20.0; Wiron, 63.0 +/- 13.5; IPS d.SIGN 20, 71.7 +/- 19.2; Argeloy NP, 55.2 +/- 13.5. No significant differences were found among the shear bond strength values for the metal-ceramic specimens tested.Conclusion. None of the base metal alloys studied demonstrated superior bond strength to the porcelain tested.
Resumo:
Statement of problem. Titanium has physical and mechanical properties, which have led to its increased use in dental prostheses despite casting difficulties due to high melting point and formation of oxide layers which affect the metal-ceramic bond strength.Purpose. This in vitro study evaluated the shear bond strength of the interface of 2 dental porcelains and pure titanium injected into a mold at 3 different temperatures.Material and methods. Using commercially pure (cp) titanium bars (Titanium, Grade I) melted at 1668degreesC and cast at mold temperatures of 430degreesC, 700degreesC or 900degreesC, 60 specimens were machined to 4 x 4 mm, with a base of 5 x 1 mm. The 4-mm surfaces were airborne-particle abraded with 100 mum aluminum oxide before applying and firing the bonding agent and evaluating the 2 porcelains (Triceram/Triline ti and Vita Titankeramik). Ten specimens were prepared for each temperature and porcelain combination Shear bond testing was performed in a universal testing machine, with a 500-kg load cell and crosshead speed of 0.5 mm/min. The specimens were loaded until failure. The interfaces of representative fractured specimens of each temperature were examined with a scanning electron microscope (SEM) and energy dispersive spectrometer (EDS). Data for shear bond strength (MPa) were statistically analyzed by 2-way ANOVA and the Tukey test (alpha = .05).Results. The results showed significant differences for the metal/porcelain interaction effect (P = .0464). There were no significant differences for the 2 porcelains (P = .4250). The Tukey test showed a significant difference between the pair cp Ti 430degreesC Triceram and cp Ti 900degreesC Triceram, with respective mean values and SDs of 59.74 +/- 11.62 and 34.03 +/- 10.35 MPa.Conclusion. Triceram porcelain showed a bond strength decrease with an increase in the mold temperature for casting titanium. The highest bond strength for Vita porcelain and the best metal-ceramic interface observed with the SEM were found with the mold temperature of 700degreesC.
Resumo:
Sodium, potassium adenosine triphosphatase (Na,K-ATPase) is a membrane-bound enzyme that maintains the Na+ and K+ gradients used in the nervous system for generation and transmission of bioelectricity. Recently, its activity has also been demonstrated during nerve regeneration. The present study was undertaken to investigate the ultrastructural localization and distribution of Na,K-ATPase in peripheral nerve fibers. Small blocks of the sciatic nerves of male Wistar rats weighing 250-300g were excised, divided into two groups, and incubated with and without substrate, the para-nitrophenyl phosphate (pNPP). The material was processed for transmission electron microscopy, and the ultra-thin sections were examined in a Philips CNI 100 (TM) electron microscope. The deposits of reaction product were localized mainly on the axolemma, on axoplasmic profiles, and irregularly dispersed on the myelin sheath, but not in the unmyelinated axons. In the axonal membrane, the precipitates were regularly distributed on the cytoplasmic side. These results together with published data warrant further studies for the diagnosis and treatment of neuropathies with compromised Na,K-ATPase activity. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Background: Hematology tests are useful to evaluate physiologic disturbances in fish and can provide important information for the diagnosis and prognosis of disease. Objectives: the primary purpose of this study was to define reference intervals for thrombocytes and leukocytes in healthy channel catfish (Ictalurus punctactus). In addition, the morphologic, cytochernical, and ultrastructural features of blood cells were assessed. Methods: Blood samples (0.5 mL were collected into EDTA from 40 clinically healthy catfish on a commercial fish farm in Jaboticabal, Brazil. Thrombocyte, total WBC, and differential WBC counts were determined and reference intervals were calculated as the 25-95th percentiles of data. Thrombocyte and leukocyte morphology was assessed in blood smears stained with May Griinwald-Giemsa-Wright and ultrastructurally by transmission electron microscopy. Cytochemical staining patterns were described using periodic acid-Schiff (PAS), peroxidase, nonspecific esterase, alkaline phosphatase, and toluidine blue. Results: Reference intervals were as follows: thrombocytes 58,802-99,569/mu L; total WBCs 27,460-41,523/mu L; lymphocytes 5380-11,581/mu L; monocytes 2949-7459/mu L; neutrophils 12,529-22,748/mu L, and basophils 736-2003/mu L. Neutrophils were positive for peroxidase and PAS; monocytes were positive for nonspecific esterase; and basophils were positive with toluidine blue. Conclusion: the morphologic and staining features of neutrophils and monocytes of channel catfish are similar to those of mammals, and the presence of basophils in this species was verified. These reference intervals and morphologic findings provide a foundation for future investigations on the functions and alterations of blood cells in channel catfish.
Resumo:
BACKGROUND. The extracellular matrix (ECM) has important roles in prostatic development, and marked stromal changes take place in the rat ventral prostate (VP) after androgen deprivation. However, little knowledge exists about individual ECM components.METHODS. The distribution of elastic fibers (EF) and elastic-related fibers (ERF) in the VP of castrated and control rats was investigated, using histochemistry and transmission electron microscopy (TEM).RESULTS. EF are barely detected in the prostatic stroma, but ERF are relatively abundant. Castration results in a relative increase in the number and thickness of ERF. TEM showed an open network of ECM microfibrils throughout the stroma and thin and short EF, which increase in number and thickness after orchiectomy.CONCLUSIONS. The presence of elastic system components in the rat VP warrants the deformability required for the secretion exclusion under the action of smooth muscle cells, and the castration-induced modification may be related to the contraction of the tissue and maintenance of peculiar arrangements of other ECM components. (C) 1997 Wiley-Liss, Inc.
Resumo:
In order to characterize the cellular component of the polymorphous low-grade adenocarcinoma (PLGA) of the salivary gland, a morphological and immunohistochemical study was carried out. Thirty cases of PLGA were studied by light microscopy and immunohistochemistry and five cases by transmission electron microscopy (TEM). The expression of cytokeratins (CKs) 7,8,10,13,14,18,19, vimentin and muscle-specific actin (MSA) was investigated through the streptavidin-biotin method. The majority of tumor cells stained for vimentin, CKs 8,18 and 7. CK 14 was positive in most cells of the papillary and trabecular sub-types. Although the expression of CKs 8,18 and 14 varied among the tumors sub-types, a straight relationship between each histologic pattern and the CK expression could not be delineated. MSA was reactive in only three tumors while CKs 10 and 13 were not detected in any tumor studied. The absence of MSA and the expression of CKs 8,18 and 7, in most of the tumor cells, lead to the hypothesis that myoepithelial cells are not the major cellular component of the PLGA. TEM revealed cells exhibiting microvilli and variable amounts of secretory granules, some of them suggesting an excretory activity. The presence of CKs 8, 18 and 7, added to the secretory granules, indicates that PLGA originates from cells located at the acinar-intercalated duct junction. (C) 1999 Elsevier B.V. Ltd. All rights reserved.
Resumo:
This study compared the microtensile bond strength of a repair resin to an alumina-reinforced feldspathic ceramic (Vitadur-alpha, Vita) after 3 surface conditioning methods: Group 1, etching with 9.6% hydrofluoric acid for 1 minute plus rinsing and drying, followed by application of silane for 5 minutes; group 2, airborne particle abrasion with 110-mm aluminum oxide using a chairside air-abrasion device followed by silane application for 5 minutes; group 3, chairside tribochemical silica coating with 30-mu m SiOx followed by silane application for 5 minutes (N = 30). Group 1 presented the highest mean bond strength (19.7 +/- 3.8 MPa), which was significantly higher than those of groups 2 (10 +/- 2.6 MPa) and 3 (10.4 +/- 4 MPa) (P <.01). Scanning electron microscope analysis of the failure modes demonstrated predominantly mixed types of failures, with adhesive and/or cohesive failures in all experimental groups.
Resumo:
Bottom-up methods to obtain nanocrystals usually result in metastable phases, even in processes carried out at room temperature or under soft annealing conditions. However, stable phases, often associated with anisotropic shapes, are obtained in only a few special cases. In this paper we report on the synthesis of two well-studied oxides-titanium and zirconium oxide-in the nanometric range, by a novel route based on the decomposition of peroxide complexes of the two metals under hydrothermal soft conditions, obtaining metastable and stable phases in both cases through transformation. High-resolution transmission electron microscopy analysis reveals the existence of typical defects relating to growth by the oriented attachment mechanism in the stable crystals. The results suggest that the mechanism is associated to the phase transformation of these structures.
Resumo:
Initially this paper shows the ground wire reduction process for generic multiphase transmission lines and after, the ground wire reduction process for a specilic 440-kV three-phase overhead transmission line. Following this, the influence of the ground wire reduction process considering two situations is shown: first, considering frequency independence and second, when these parameters are considered as frequency dependent. This paper presents analytical results for generic multiphase transmission lines. For a specific 440-kV three-phase overhead transmission line, analytical and graphic results are shown considering real data for every frequency between 10 Hz and 1 MHz.
Resumo:
Objective: the purpose of this study is to make use of scanning electron microscopy in order to comparatively analyze the morphological alterations to human and bovine enamel and dentin. Earlier data: Many a morphological study involving Er:YAG laser can be found in the literature. Still, not a single study comparing the effects of this infrared laser in human and bovine teeth has been reported. Materials and Methods: Thirty-two slices of human and bovine enamel and dentin were evenly divided into four groups. With the exception of the control group, the samples were irradiated with Er:YAG laser, focused at a distance of 12 mm and a 10-Hz frequency, with 150, 250, and 350 mJ of output energy per pulse for 10 seconds. After irradiation all specimens were observed under a scanning electron microscope. Results: There was practically no morphological difference for those samples that underwent 150 mJ/pulse irradiation. The dentin exposed to 250 mJ had a few open dentinal tubules. These were seen in enamel after a 350 mJ irradiation, in which the energy was able to reach the dentin. Conclusions: the breadth of this study allows us to state that the pattern between the species grew more heterogenous as the energy density was increased and that irradiation with 150 mJ/pulse resulted in greater likeness in human and bovine enamel and dentin.
Resumo:
Background and Objectives: Epithelial rests of Malassez are clusters of cells derived from Hertwig's root sheath that remain in the periodontal ligament throughout life. Although it is known that the cells of Malassez proliferate, there are no studies showing that they undergo programmed cell death, i.e. apoptosis. In most tissues, proliferation is balanced by apoptosis. Thus we examined regions of the periodontium of young and adult rat molars in the hope of detecting apoptosis.Methods: Wistar rats aged 29, 45 and 120 days were killed with chloral hydrate (600 mg/kg). Fragments containing maxillary molars were removed and fixed in formaldehyde, decalcified, and embedded in paraffin and glycol methacrylate. Sections were stained with hematoxylin/eosin and the Terminal deoxynucleotidyl transferase-mediated dUTP Nick End Labeling (TUNEL) method for detection of apoptosis. Specimens were also fixed in glutaraldehyde-formaldehyde, decalcified and processed for transmission electron microscopy.Results: Epithelial rests of Malassez containing round/ovoid basophilic dense bodies and TUNEL-positive structures were found in all specimens examined. Ultrastructural examination revealed that some cells of Malassez contained masses of condensed peripheral chromatin and a shrunken cytoplasm exhibiting intact organelles - images typical of apoptosis. Moreover, round/ovoid electron-opaque structures appeared to be in the process of being engulfed by neighboring epithelial cells of Malassez.Conclusions: Our results demonstrate that epithelial cells of Malassez's rests undergo apoptosis in the developing and adult periodontium. Apoptosis may, together with proliferation, be part of the mechanism of turnover/remodelling of the cells of Malassez.