960 resultados para swd: Image segmentation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently Adams and Bischof (1994) proposed a novel region growing algorithm for segmenting intensity images. The inputs to the algorithm are the intensity image and a set of seeds - individual points or connected components - that identify the individual regions to be segmented. The algorithm grows these seed regions until all of the image pixels have been assimilated. Unfortunately the algorithm is inherently dependent on the order of pixel processing. This means, for example, that raster order processing and anti-raster order processing do not, in general, lead to the same tessellation. In this paper we propose an improved seeded region growing algorithm that retains the advantages of the Adams and Bischof algorithm fast execution, robust segmentation, and no tuning parameters - but is pixel order independent. (C) 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a review of perceptual image quality metrics and their application to still image compression. The review describes how image quality metrics can be used to guide an image compression scheme and outlines the advantages, disadvantages and limitations of a number of quality metrics. We examine a broad range of metrics ranging from simple mathematical measures to those which incorporate full perceptual models. We highlight some variation in the models for luminance adaptation and the contrast sensitivity function and discuss what appears to be a lack of a general consensus regarding the models which best describe contrast masking and error summation. We identify how the various perceptual components have been incorporated in quality metrics, and identify a number of psychophysical testing techniques that can be used to validate the metrics. We conclude by illustrating some of the issues discussed throughout the paper with a simple demonstration. (C) 1998 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The compound eyes of mantis shrimps, a group of tropical marine crustaceans, incorporate principles of serial and parallel processing of visual information that may be applicable to artificial imaging systems. Their eyes include numerous specializations for analysis of the spectral and polarizational properties of light, and include more photoreceptor classes for analysis of ultraviolet light, color, and polarization than occur in any other known visual system. This is possible because receptors in different regions of the eye are anatomically diverse and incorporate unusual structural features, such as spectral filters, not seen in other compound eyes. Unlike eyes of most other animals, eyes of mantis shrimps must move to acquire some types of visual information and to integrate color and polarization with spatial vision. Information leaving the retina appears to be processed into numerous parallel data streams leading into the central nervous system, greatly reducing the analytical requirements at higher levels. Many of these unusual features of mantis shrimp vision may inspire new sensor designs for machine vision

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Axial X-ray Computed tomography (CT) scanning provides a convenient means of recording the three-dimensional form of soil structure. The technique has been used for nearly two decades, but initial development has concentrated on qualitative description of images. More recently, increasing effort has been put into quantifying the geometry and topology of macropores likely to contribute to preferential now in soils. Here we describe a novel technique for tracing connected macropores in the CT scans. After object extraction, three-dimensional mathematical morphological filters are applied to quantify the reconstructed structure. These filters consist of sequences of so-called erosions and/or dilations of a 32-face structuring element to describe object distances and volumes of influence. The tracing and quantification methodologies were tested on a set of undisturbed soil cores collected in a Swiss pre-alpine meadow, where a new earthworm species (Aporrectodea nocturna) was accidentally introduced. Given the reduced number of samples analysed in this study, the results presented only illustrate the potential of the method to reconstruct and quantify macropores. Our results suggest that the introduction of the new species induced very limited chance to the soil structured for example, no difference in total macropore length or mean diameter was observed. However. in the zone colonised by, the new species. individual macropores tended to have a longer average length. be more vertical and be further apart at some depth. Overall, the approach proved well suited to the analysis of the three-dimensional architecture of macropores. It provides a framework for the analysis of complex structures, which are less satisfactorily observed and described using 2D imaging. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Concerns exist regarding the effect of radiation dose from paediatric pelvic CT scans and the potential later risk of radiation-induced neoplasm and teratogenic outcomes in these patients. Objective: To assess the diagnostic quality of CT images of the paediatric pelvis using either reduced mAs or increased pitch compared with standard settings. Materials and methods: A prospective study of pelvic CT scans of 105 paediatric patients was performed using one of three protocols: (1) 31 at a standard protocol of 200 mA with rotation time of 0.75 s at 120 kVp and a pitch factor approximating 1.4; (2) 31 at increased pitch factor approaching 2 and 200 mA; and (3) 43 at a reduced setting of 100 mA and a pitch factor of 1.4. All other settings remained the same in all three groups. Image quality was assessed by radiologists blinded to the protocol used in each scan. Results: No significant difference was found between the quality of images acquired at standard settings and those acquired at half the standard mAs. The use of increased pitch factor resulted in a higher proportion of poor images. Conclusions: Images acquired at 120 kVp using 75 mAs are equivalent in diagnostic quality to those acquired at 150 mAs. Reduced settings can provide useful imaging of the paediatric pelvis and should be considered as a standard protocol in these situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The applicability of image calibration to like-values in mapping water quality parameters from multitemporal images is explored, Six sets of water samples were collected at satellite overpasses over Moreton Bay, Brisbane, Australia. Analysis of these samples reveals that waters in this shallow bay are mostly TSS-dominated, even though they are occasionally dominated by chlorophyll as well. Three of the images were calibrated to a reference image based on invariant targets. Predictive models constructed from the reference image were applied to estimating total suspended sediment (TSS) and Secchi depth from another image at a discrepancy of around 35 percent. Application of the predictive model for TSS concentration to another image acquired at a time of different water types resulted in a discrepancy of 152 percent. Therefore, image calibration to like-values could be used to reliably map certain water quality parameters from multitemporal TM images so long as the water type under study remains unchanged. This method is limited in that the mapped results could be rather inaccurate if the water type under study has changed considerably. Thus, the approach needs to be refined in shallow water from multitemporal satellite imagery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An important segmentation basis used by firms is related to consumers` personal values which are investigated in this study. It was used a descriptive research with the survey method of data collection in a sample of executives from Sao Paulo who are considered to be potential buyers of high value and innovative goods. An exploratory factor analysis was employed in order to reduce the values scale used and a cluster analysis was performed to identify the groups of executives according to the importance attached to different person values. Concluding, it was observed that there was a similarity among the three personal values dimensions, named as Civility (concerns about having a good conduct before society according to social rules of interaction), Self-Direction (intellectual aspects and practical orientation in their conducts) and Conformity (restriction of actions, inclinations and impulses, that are likely to harm others and would violate expectations) and the ones reported in the theory Rokeach`s theory about instrumental personal values. Furthermore, three groups of executives were identified (good conduct group, low restriction group and high restriction group). The differences observed in the importance of personal values here presented by the dimensions called Civility, Self-Direction and Conformity can lead to different buying behaviors and product preferences. From the results found in this study the companies could adapt their current and new products offers, as well as their communication in order to better serve these segments of executives from Sao Paulo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Targeting is increasingly used to manage people. It operates by segmenting populations and providing different levels of opportunities and services to these groups. Each group is subject to different levels of surveillance and scrutiny. This article examines the deployment of targeting in Australian social security. Three case studies of targeting are presented in Australia's management of benefit overpayment and fraud, the distribution of employment services and the application of workfare. In conceptualizing surveillance as governance, the analysis examines the rationalities, technologies and practices that make targeting thinkable, practicable and achievable. In the case studies, targeting is variously conceptualized and justified by calculative risk discourses, moral discourses of obligation and notions of welfare dependency Advanced information technologies are also seen as particularly important in giving rise to the capacity to think about and act on population segments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Techniques applying digital images increasingly have been used in biology, medicine, physics, and other research areas. The image coordinates can represent light intensities values to be detected by a CCD. Based on this concept, a photometric system composed of a LED source and a digital camera as a detector was used for optical density measurements. Standards for permanganate, glucose, and protein solutions were detemined by colorimetric methods using our device. Samples of protein of Pasteurella mutocida bacteria membrane and, also, fractions of rabbit kidney membrane, rich in Na, K-ATPase, with unknown concentrations were dosed through the Hartree method using our photometric system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

What different forms of engagement do image and text allow the spectator/reader? We know that text and image communicate, and that all communication depends on a relationship between those who communicate. The objective of this text is therefore to understand the new possibilities available to an anthropology of the expression of knowledge that makes use of images, such as photographs and films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Lung hyperinflation may be assessed by computed tomography (CT). As shown for patients with emphysema, however, CT image reconstruction affects quantification of hyperinflation. We studied the impact of reconstruction parameters on hyperinflation measurements in mechanically ventilated (MV) patients. Design: Observational analysis. Setting: A University hospital-affiliated research Unit. Patients: The patients were MV patients with injured (n = 5) or normal lungs (n = 6), and spontaneously breathing patients (n = 5). Interventions: None. Measurements and results: Eight image series involving 3, 5, 7, and 10 mm slices and standard and sharp filters were reconstructed from identical CT raw data. Hyperinflated (V-hyper), normally (V-normal), poorly (V-poor), and nonaerated (V-non) volumes were calculated by densitometry as percentage of total lung volume (V-total). V-hyper obtained with the sharp filter systematically exceeded that with the standard filter showing a median (interquartile range) increment of 138 (62-272) ml corresponding to approximately 4% of V-total. In contrast, sharp filtering minimally affected the other subvolumes (V-normal, V-poor, V-non, and V-total). Decreasing slice thickness also increased V-hyper significantly. When changing from 10 to 3 mm thickness, V-hyper increased by a median value of 107 (49-252) ml in parallel with a small and inconsistent increment in V-non of 12 (7-16) ml. Conclusions: Reconstruction parameters significantly affect quantitative CT assessment of V-hyper in MV patients. Our observations suggest that sharp filters are inappropriate for this purpose. Thin slices combined with standard filters and more appropriate thresholds (e.g., -950 HU in normal lungs) might improve the detection of V-hyper. Different studies on V-hyper can only be compared if identical reconstruction parameters were used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oral squamous cell carcinoma (OSCC) is associated with high morbidity and mortality which is due, at least in part, to late detection. Precancerous and cancerous oral lesions may mimic any number of benign oral lesions, and as such may be left without investigation and treatment until they are well advanced. Over the past several years there has been renewed interest in oral cytology as an adjuvant clinical tool in the investigation of oral mucosal lesions. The purpose of the present study was to compare the usefulness of ploidy analysis after Feulgen stained cytological thin-prep specimens with traditional incisional biopsy and routine histopathological examination for the assessment of the pre-malignant potential of oral mucosal lesions. An analysis of the cytological specimens was undertaken with virtual microscopy which allowed for rapid and thorough analysis of the complete cytological specimen. 100 healthy individuals between 30 and 70 years of age, who were non-smokers, non-drinkers and not taking any medication, had cytological specimens collected from both the buccal mucosa and lateral margin of tongue to establish normal cytology parameters within a control population. Patients with a presumptive clinical diagnosis of lichen planus, leukoplakia or OSCC had lesional cytological samples taken prior to their diagnostic biopsy. Standardised thin preparations were prepared and each specimen stained by both Feuglen and Papanicolau methods. High speed scanning of the complete slide at 40X magnification was undertaken using the Aperio Scanscope TM and the green channel of the resultant image was analysed after threshold segmentation to isolate only nuclei and the integrated optical density of each nucleus taken as a gross measure of the DNA content (ploidy). Preliminary results reveal that ploidy assessment of oral cytology holds great promise as an adjunctive prognostic factor in the analysis of the malignant potential of oral mucosal lesions.