462 resultados para standardize
Resumo:
Although duodenopancreatectomy has been standardized for many years, the pathological examination of the specimen was re-described in the last years. In methodical pathological studies up to 85% had an R1 margin.1,2 These mainly involved the posterior und medial resection margin.3 As a consequence we need to optimize and standardize the pathological workup of the specimen and to extend the surgical resection, where possible without risk for the patient.
Resumo:
BACKGROUND: In contrast to hypnosis, there is no surrogate parameter for analgesia in anesthetized patients. Opioids are titrated to suppress blood pressure response to noxious stimulation. The authors evaluated a novel model predictive controller for closed-loop administration of alfentanil using mean arterial blood pressure and predicted plasma alfentanil concentration (Cp Alf) as input parameters. METHODS: The authors studied 13 healthy patients scheduled to undergo minor lumbar and cervical spine surgery. After induction with propofol, alfentanil, and mivacurium and tracheal intubation, isoflurane was titrated to maintain the Bispectral Index at 55 (+/- 5), and the alfentanil administration was switched from manual to closed-loop control. The controller adjusted the alfentanil infusion rate to maintain the mean arterial blood pressure near the set-point (70 mmHg) while minimizing the Cp Alf toward the set-point plasma alfentanil concentration (Cp Alfref) (100 ng/ml). RESULTS: Two patients were excluded because of loss of arterial pressure signal and protocol violation. The alfentanil infusion was closed-loop controlled for a mean (SD) of 98.9 (1.5)% of presurgery time and 95.5 (4.3)% of surgery time. The mean (SD) end-tidal isoflurane concentrations were 0.78 (0.1) and 0.86 (0.1) vol%, the Cp Alf values were 122 (35) and 181 (58) ng/ml, and the Bispectral Index values were 51 (9) and 52 (4) before surgery and during surgery, respectively. The mean (SD) absolute deviations of mean arterial blood pressure were 7.6 (2.6) and 10.0 (4.2) mmHg (P = 0.262), and the median performance error, median absolute performance error, and wobble were 4.2 (6.2) and 8.8 (9.4)% (P = 0.002), 7.9 (3.8) and 11.8 (6.3)% (P = 0.129), and 14.5 (8.4) and 5.7 (1.2)% (P = 0.002) before surgery and during surgery, respectively. A post hoc simulation showed that the Cp Alfref decreased the predicted Cp Alf compared with mean arterial blood pressure alone. CONCLUSION: The authors' controller has a similar set-point precision as previous hypnotic controllers and provides adequate alfentanil dosing during surgery. It may help to standardize opioid dosing in research and may be a further step toward a multiple input-multiple output controller.
Resumo:
The diagnosis of allergic bronchopulmonary aspergillosis (ABPA) in cystic fibrosis patients remains challenging, mainly owing to overlapping symptoms of the underlying lung disease with clinical symptoms of ABPA. In addition, a varying mixture of diagnostic criteria, including clinical status, radiological findings and immunological measurements, has led to confusion and differing recommendations. In order to help simplify as well as standardize the diagnostic criteria for ABPA, different serological markers have been evaluated in the last 20 years and their usefulness has been assessed in many clinical studies. This review presents current diagnostic criteria of ABPA, with a special focus on serum markers supporting the diagnosis and explains why the hunt for a serological marker for ABPA is still ongoing.
Resumo:
PURPOSE: Although critically ill patients usually have various central intravenous (i.v.) lines, numerous drugs have to be infused simultaneously through the same lines. This can result in potentially harmful in-line incompatibility that can cause decreased drug effectiveness or increased microparticle load. To minimize the risk of these medication errors at an anesthesia intensive care unit (ICU), the preparation and administration of continuously infused drugs were standardized and the practicability in daily clinical routine was evaluated. SUMMARY: The concentration and diluent of continuously administered i.v. drugs were standardized. The drugs were grouped according to pH, medical indication, and chemical structure. The ICU staff decided to use multilumen central venous catheters, and each group of drugs was assigned to one lumen. Only drugs that belonged to the same group were infused simultaneously through the same lumen; therefore, intragroup incompatibilities had to be excluded before establishing the new drug administration plan at the ICU. The visual compatibility of 115 clinically reasonable intragroup drug mixtures was investigated. All drug combinations were compatible for six hours except mixtures containing thiopental, which was reassigned to a single-line use. In the following year, the practicability of this drug administration plan was evaluated. No deviations were found in the compliance of the staff prescribing and preparing only standardized concentrations and diluents. Further research to investigate the chemical compatibility of the drugs in these multiple mixtures will follow. CONCLUSION: A project intended to avoid incompatibility among i.v. drugs infused in the intensive care setting included steps to standardize solutions and determine which could be given together.
Resumo:
Cell death is essential for a plethora of physiological processes, and its deregulation characterizes numerous human diseases. Thus, the in-depth investigation of cell death and its mechanisms constitutes a formidable challenge for fundamental and applied biomedical research, and has tremendous implications for the development of novel therapeutic strategies. It is, therefore, of utmost importance to standardize the experimental procedures that identify dying and dead cells in cell cultures and/or in tissues, from model organisms and/or humans, in healthy and/or pathological scenarios. Thus far, dozens of methods have been proposed to quantify cell death-related parameters. However, no guidelines exist regarding their use and interpretation, and nobody has thoroughly annotated the experimental settings for which each of these techniques is most appropriate. Here, we provide a nonexhaustive comparison of methods to detect cell death with apoptotic or nonapoptotic morphologies, their advantages and pitfalls. These guidelines are intended for investigators who study cell death, as well as for reviewers who need to constructively critique scientific reports that deal with cellular demise. Given the difficulties in determining the exact number of cells that have passed the point-of-no-return of the signaling cascades leading to cell death, we emphasize the importance of performing multiple, methodologically unrelated assays to quantify dying and dead cells.
Resumo:
Ziel dieses Beitrages ist die Analyse der Anwendung empirischer Tests in der deutschsprachigen Sportpsychologie. Die Ergebnisse vergleichbarer Analysen, bspw. in der Psychologie, zeigen, dass zwischen Anforderungen aus Testkonzepten und empirischer Realität Unterschiede existieren, die bislang für die Sportpsychologie nicht beschrieben und bewertet worden sind. Die Jahrgänge 1994–2007 der Zeitschrift für Sportpsychologie (früher psychologie und sport) wurden danach untersucht, ob Forschungsfragen formuliert, welche Stichprobenart gewählt, welches Testkonzept verwendet, welches Signifikanzniveau benutzt und ob statistische Probleme diskutiert wurden. 83 Artikel wurden von zwei unabhängigen Bewertern nach diesen Aspekten kategorisiert. Als Ergebnis ist festzuhalten, dass in der sportpsychologischen Forschung überwiegend eine Mischung aus Fishers Signifikanztesten sowie Neyman-Pearsons-Hypothesentesten zur Anwendung kommt,das sogenannte „Hybrid-Modell” oder „Null-Ritual”. Die Beschreibung der Teststärke ist kaum zu beobachten. Eine zeitliche Analyse der Beiträge zeigt, dass vor allem die Benutzung von Effektgrößen in den letzten Jahren zugenommen hat. Abschließend werden Ansätze zur Verbesserung und der Vereinheitlichung der Anwendung empirischer Tests vorgeschlagen und diskutiert.
Resumo:
BACKGROUND To standardize multiple-breath washout (MBW) measurements, 1L tidal volume (VT) protocols were suggested. The effect on MBW derived ventilation inhomogeneity (VI) indices is unclear. METHODS We compared VI indices from free breathing MBW at baseline to 1L VT MBW performed in triplicates in 35 children (20 with CF). Mean (range) age was 12.8 (7.0-16.7) years, weight 42 (20-64) kg and height 151 (117-170) cm. RESULTS Baseline lung clearance index (LCI) increased from mean (SD) 11.0 (2.2) to 13.0 (2.6), p=0.011, in CF and from 6.8 (0.5) to 7.7 (1.4), p=0.004, in controls. Moment ratio and Scond similarly increased. While change in VI indices was heterogeneous in individuals, decrease in functional residual capacity was most strongly associated with LCI increase. CONCLUSION MBW protocols strongly influence measures of VI. The 1L VT MBW protocol leads to overestimation of VI and is not recommended in children.
Resumo:
Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ECG might overcome these limitations but requires a dedicated lead system and recorder design. To this end, we analysed multiple-lead esophageal ECGs with respect to signal quality by describing the ECG waves as a function of the insertion level, interelectrode distance, electrode shape and amplifier's input range. The results derived from clinical data show that two bipolar esophageal leads, an atrial lead with short (15 mm) interelectrode distance and a ventricular lead with long (80 mm) interelectrode distance provide non-inferior ventricular signal strength and superior atrial signal strength compared to standard surface lead II. High atrial signal slope in particular is observed with the atrial esophageal lead. The proposed esophageal lead system in combination with an increased recorder input range of ±20 mV minimizes signal loss due to excessive electrode motion typically observed in esophageal ECGs. The design proposal might help to standardize long-term esophageal ECG registrations and facilitate novel ECG classification systems based on the independent detection of ventricular and atrial electrical activity.
Resumo:
Aim Current estimates of species richness within rapidly evolving species flocks are often highly dependent on the species status of allopatric populations that differ in phenotypic traits. These traits may be unreliable indicators of biological species status and systematists may have inconsistently assigned species among lineages or locations on the basis of these traits, thus hampering comparative studies of regional species richness and speciation rates. Our aim was to develop a method of generating standardized estimates of regional species richness suitable for comparative analysis, and to use these estimates to examine the extent and consistency of species assignment of allopatric populations within rapidly evolving cichlid fish flocks present in three east African lakes. Location Lakes Malawi, Victoria and Tanganyika. Methods Using published taxon co-occurrence data, a novel approach was employed to calculate standardized ‘minimum’ estimates of regional species richness for hard substrate associated complexes of cichlids within each of the lakes. Minimum estimates were based on an explicit assumption that if taxa present on equivalent habitats have disjunct distributions, then they are allopatric forms of the same species. These estimates were compared with current observed ‘high-end’ regional species richness estimates for those complexes to determine the consistency of species assignment of allopatric populations between lineages within a lake. A ‘sympatry’ index was developed to enable comparisons of levels of species assignment of allopatric populations between-lakes to be made. Results Within each lake, the minimum and high-end estimates for species richness were significantly correlated across complexes, indicating that the complexes that contain more recognized species contain the most genuine biological species. However, comparisons of complexes among lakes revealed considerable differences. For equivalent geographical areas, substantially higher proportions of recognized species were totally allopatric within the studied Lake Malawi and Lake Victoria complexes, than those of Lake Tanganyika. Main Conclusions Among African lakes, levels of assignment to species status of allopatric populations were found to be distinctly different. It is unclear whether the discrepancies are a consequence of differences between the lake faunas in degrees of phenotypic divergence among allopatric populations, or are simply the result of inconsistent taxonomic practices. In either case, these results have considerable wider relevance for they emphasize that quantitative measures of regional and beta diversity are critically dependent on the species status of allopatric populations, an issue usually neglected in comparative studies of species richness. The technique introduced here can be used to standardize measures of regional diversity of lineages for comparative analyses, potentially enabling more accurate identification of processes influencing rates of speciation.
Resumo:
BACKGROUND The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. OBJECTIVE Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. METHODS Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. RESULTS A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. CONCLUSIONS The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.
Resumo:
Two batches of excretory/secretory (E/S) antigens from second stage larvae of Toxocara canis maintained in vitro were prepared independently in two different laboratories (Zürich and Basel) and analysed in order to obtain information for future efforts to standardize the enzyme-linked immunosorbent assay (ELISA) used for the serodiagnosis of human toxocariasis. SDS-PAGE and "Western-blotting" revealed at least 10 different antigenic components common to the two antigen preparations. However, distinct qualitative and quantitative differences among the two E/S-antigens were observed, since one antigen had a more complex composition than the other. Despite these differences, an accordance of serodiagnosis was obtained in 80% of 25 sera from patients with suspected Toxocara infection tested independently in two different ELISA systems (Basel and Zürich) with the corresponding E/S-antigens. The specificity was 93% as determined (BS-antigen, BS-ELISA) by testing 46 out of 3396 sera from patients with parasitologically proven extra-intestinal helminthic infections. Cross-reactions occurred mainly with sera from patients infected with filariae (5 from 13 cases) exhibiting very high extinction values in their homologous ELISA-system. The reproducibility (intra- and inter-test variations) of two ELISA systems using the corresponding E/S-antigens varied from 5-15%. The results demonstrate that T. canis E/S-antigens may well be applicable for standardization of the ELISA used for the serodiagnosis of human toxocariasis.
Resumo:
Femoro-patellar dysplasia is considered as a significant risk factor of patellar instability. Different studies suggest that the shape of the trochlea is already developed in early childhood. Therefore early identification of a dysplastic configuration might be relevant information for the treating physician. An easy applicable routine screening of the trochlea is yet not available. The purpose of this study was to establish and evaluate a screening method for femoro-patellar dysplasia using 3D ultrasound. From 2012 to 2013 we prospectively imaged 160 consecutive femoro-patellar joints in 80 newborns from the 36th to 61st gestational week that underwent a routine hip sonography (Graf). All ultrasounds were performed by a pediatric radiologist with only minimal additional time to the routine hip ultrasound. In 30° flexion of the knee, axial, coronal, and sagittal reformats were used to standardize a reconstructed axial plane through the femoral condyle and the mid-patella. The sulcus angle, the lateral-to-medial facet ratio of the trochlea and the shape of the patella (Wiberg Classification) were evaluated. In all examinations reconstruction of the standardized axial plane was achieved, the mean trochlea angle was 149.1° (SD 4.9°), the lateral-to-medial facet ratio of the trochlea ratio was 1.3 (SD 0.22), and a Wiberg type I patella was found in 95% of the newborn. No statistical difference was detected between boys and girls. Using standardized reconstructions of the axial plane allows measurements to be made with lower operator dependency and higher accuracy in a short time. Therefore 3D ultrasound is an easy applicable and powerful tool to identify trochlea dysplasia in newborns and might be used for screening for trochlea dysplasia.
Resumo:
XMapTools is a MATLAB©-based graphical user interface program for electron microprobe X-ray image processing, which can be used to estimate the pressure–temperature conditions of crystallization of minerals in metamorphic rocks. This program (available online at http://www.xmaptools.com) provides a method to standardize raw electron microprobe data and includes functions to calculate the oxide weight percent compositions for various minerals. A set of external functions is provided to calculate structural formulae from the standardized analyses as well as to estimate pressure–temperature conditions of crystallization, using empirical and semi-empirical thermobarometers from the literature. Two graphical user interface modules, Chem2D and Triplot3D, are used to plot mineral compositions into binary and ternary diagrams. As an example, the software is used to study a high-pressure Himalayan eclogite sample from the Stak massif in Pakistan. The high-pressure paragenesis consisting of omphacite and garnet has been retrogressed to a symplectitic assemblage of amphibole, plagioclase and clinopyroxene. Mineral compositions corresponding to ~165,000 analyses yield estimates for the eclogitic pressure–temperature retrograde path from 25 kbar to 9 kbar. Corresponding pressure–temperature maps were plotted and used to interpret the link between the equilibrium conditions of crystallization and the symplectitic microstructures. This example illustrates the usefulness of XMapTools for studying variations of the chemical composition of minerals and for retrieving information on metamorphic conditions on a microscale, towards computation of continuous pressure–temperature-and relative time path in zoned metamorphic minerals not affected by post-crystallization diffusion.
Resumo:
Minimal invasive extracorporeal circulation (MiECC) systems have initiated important efforts within science and technology to further improve the biocompatibility of cardiopulmonary bypass components to minimize the adverse effects and improve end-organ protection. The Minimal invasive Extra-Corporeal Technologies international Society was founded to create an international forum for the exchange of ideas on clinical application and research of minimal invasive extracorporeal circulation technology. The present work is a consensus document developed to standardize the terminology and the definition of minimal invasive extracorporeal circulation technology as well as to provide recommendations for the clinical practice. The goal of this manuscript is to promote the use of MiECC systems into clinical practice as a multidisciplinary strategy involving cardiac surgeons, anaesthesiologists and perfusionists.
Resumo:
Femoroacetabular impingement (FAI) is a dynamic conflict of the hip defined by a pathological, early abutment of the proximal femur onto the acetabulum or pelvis. In the past two decades, FAI has received increasing focus in both research and clinical practice as a cause of hip pain and prearthrotic deformity. Anatomical abnormalities such as an aspherical femoral head (cam-type FAI), a focal or general overgrowth of the acetabulum (pincer-type FAI), a high riding greater or lesser trochanter (extra-articular FAI), or abnormal torsion of the femur have been identified as underlying pathomorphologies. Open and arthroscopic treatment options are available to correct the deformity and to allow impingement-free range of motion. In routine practice, diagnosis and treatment planning of FAI is based on clinical examination and conventional imaging modalities such as standard radiography, magnetic resonance arthrography (MRA), and computed tomography (CT). Modern software tools allow three-dimensional analysis of the hip joint by extracting pelvic landmarks from two-dimensional antero-posterior pelvic radiographs. An object-oriented cross-platform program (Hip2Norm) has been developed and validated to standardize pelvic rotation and tilt on conventional AP pelvis radiographs. It has been shown that Hip2Norm is an accurate, consistent, reliable and reproducible tool for the correction of selected hip parameters on conventional radiographs. In contrast to conventional imaging modalities, which provide only static visualization, novel computer assisted tools have been developed to allow the dynamic analysis of FAI pathomechanics. In this context, a validated, CT-based software package (HipMotion) has been introduced. HipMotion is based on polygonal three-dimensional models of the patient’s pelvis and femur. The software includes simulation methods for range of motion, collision detection and accurate mapping of impingement areas. A preoperative treatment plan can be created by performing a virtual resection of any mapped impingement zones both on the femoral head-neck junction, as well as the acetabular rim using the same three-dimensional models. The following book chapter provides a summarized description of current computer-assisted tools for the diagnosis and treatment planning of FAI highlighting the possibility for both static and dynamic evaluation, reliability and reproducibility, and its applicability to routine clinical use.