901 resultados para radius-ulna


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We simulate freely jointed chains to investigate how knotting affects the overall shapes of freely fluctuating circular polymeric chains. To characterize the shapes of knotted polygons, we construct enveloping ellipsoids that minimize volume while containing the entire polygon. The lengths of the three principal axes of the enveloping ellipsoids are used to define universal size and shape descriptors analogous to the squared radius of gyration and the inertial asphericity and prolateness. We observe that polymeric chains forming more complex knots are more spherical and also more prolate than chains forming less complex knots with the same number of edges. We compare the shape measures, determined by the enveloping ellipsoids, with those based on constructing inertial ellipsoids and explain the differences between these two measures of polymer shape.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of the pseudopotential on both the structure and the self-diffusion of liquid rubidium at the melting point has been investigated by means of molecular-dynamics calculations. The model potential considered has been computed from the pseudopotential of Ashcroft, the dielectric function of Geldart and Vosko, and a Born-Mayer term. Four different values for the core radius which enters as input in the pseudopotential have been considered. In this way we have been able to observe and interpret the effect of this contribution on the properties of the liquid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context: In the milder form of primary hyperparathyroidism (PHPT), cancellous bone, represented by areal bone mineral density at the lumbar spine by dual-energy x-ray absorptiometry (DXA), is preserved. This finding is in contrast to high-resolution peripheral quantitative computed tomography (HRpQCT) results of abnormal trabecular microstructure and epidemiological evidence for increased overall fracture risk in PHPT. Because DXA does not directly measure trabecular bone and HRpQCT is not widely available, we used trabecular bone score (TBS), a novel gray-level textural analysis applied to spine DXA images, to estimate indirectly trabecular microarchitecture. Objective: The purpose of this study was to assess TBS from spine DXA images in relation to HRpQCT indices and bone stiffness in radius and tibia in PHPT. Design and Setting: This was a cross-sectional study conducted in a referral center. Patients: Participants were 22 postmenopausal women with PHPT. Main Outcome Measures: Outcomes measured were areal bone mineral density by DXA, TBS indices derived from DXA images, HRpQCT standard measures, and bone stiffness assessed by finite element analysis at distal radius and tibia. Results: TBS in PHPT was low at 1.24, representing abnormal trabecular microstructure (normal ≥1.35). TBS was correlated with whole bone stiffness and all HRpQCT indices, except for trabecular thickness and trabecular stiffness at the radius. At the tibia, correlations were observed between TBS and volumetric densities, cortical thickness, trabecular bone volume, and whole bone stiffness. TBS correlated with all indices of trabecular microarchitecture, except trabecular thickness, after adjustment for body weight. Conclusion: TBS, a measurement technology readily available by DXA, shows promise in the clinical assessment of trabecular microstructure in PHPT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work is dedicated to investigation of the energy spectrum of one of the most anisotropic narrow-gap semiconductors, CdSb. At the beginning of the present studies even the model of its energy band structure was not clear. Measurements of galvanomagnetic effects in wide temperature range (1.6 - 300 K) and in magnetic fields up to 30 T were chosen for clarifying of the energy spectrum in the intentionally undoped CdSb single crystals and doped with shallow impurities (In, Ag). Detection of the Shubnikov - de Haas oscillations allowed estimating the fundamental energy spectrum parameters. The shapes of the Fermi surfaces of electrons (sphere) and holes (ellipsoid), the number of the equivalent extremums for valence band (2) and their positions in the Brillouin zone were determined for the first time in this work. Also anisotropy coefficients, components of the tensor of effective masses of carriers, effective masses of density of states, nonparabolicity of the conduction and valence bands, g-factor and its anisotropy for n- and p-CdSb were estimated for the first time during these studies. All the results obtained are compared with the cyclotron resonance data and the corresponding theoretical calculations for p-CdSb. This is basic information for the analyses of the complex transport properties of CdSb and for working out the energy spectrum model of the shallow energy levels of defects and impurities in this semiconductor. It was found out existence of different mechanisms of hopping conductivity in the presence of metal - insulator transition induced by magnetic field in n- and p-CdSb. Quite unusual feature opened in CdSb is that different types of hopping conductivity may take place in the same crystal depending on temperature, magnetic field or even orientation of crystal in magnetic field. Transport properties of undoped p-CdSb samples show that the anisotropy of the resistivity in weak and strong magnetic fields is determined completely by the anisotropy of the effective mass of the holes. Temperature and magnetic field dependence of the Hall coefficient and magnetoresistance is attributed to presence of two groups of holes with different concentrations and mobilities. The analysis demonstrates that below Tcr ~ 20 K and down to ~ 6 - 7 K the low-mobile carriers are itinerant holes with energy E2 ≈ 6 meV. The high-mobile carriers, at all temperatures T < Tcr, are holes activated thermally from a deeper acceptor band to itinerant states of a shallower acceptor band with energy E1 ≈ 3 meV. Analysis of temperature dependences of mobilities confirms the existence of the heavy-hole band or a non-equivalent maximum and two equivalent maxima of the light-hole valence band. Galvanomagnetic effects in n-CdSb reveal the existence of two groups of carriers. These are the electrons of a single minimum in isotropic conduction band and the itinerant electrons of the narrow impurity band, having at low temperatures the energies above the bottom of the conduction band. It is found that above this impurity band exists second impurity band of only localized states and the energy of both impurity bands depend on temperature so that they sink into the band gap when temperature is increased. The bands are splitted by the spin, and in strong magnetic fields the energy difference between them decreases and redistribution of the electrons between the two impurity bands takes place. Mobility of the conduction band carriers demonstrates that scattering in n-CdSb at low temperatures is strongly anisotropic. This is because of domination from scattering on the neutral impurity centers and increasing of the contribution to mobility from scattering by acoustic phonons when temperature increases. Metallic conductivity in zero or weak magnetic field is changed to activated conductivity with increasing of magnetic field. This exhibits a metal-insulator transition (MIT) induced by the magnetic field due to shift of the Fermi level from the interval of extended states to that of the localized states of the electron spectrum near the edge of the conduction band. The Mott variablerange hopping conductivity is observed in the low- and high-field intervals on the insulating side of the MIT. The results yield information about the density of states, the localization radius of the resonant impurity band with completely localized states and about the donor band. In high magnetic fields this band is separated from the conduction band and lies below the resonant impurity bands.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The general objective of this study was to conduct astatistical analysis on the variation of the weld profiles and their influence on the fatigue strength of the joint. Weld quality with respect to its fatigue strength is of importance which is the main concept behind this thesis. The intention of this study was to establish the influence of weld geometric parameters on the weld quality and fatigue strength. The effect of local geometrical variations of non-load carrying cruciform fillet welded joint under tensile loading wasstudied in this thesis work. Linear Elastic Fracture Mechanics was used to calculate fatigue strength of the cruciform fillet welded joints in as-welded condition and under cyclic tensile loading, for a range of weld geometries. With extreme value statistical analysis and LEFM, an attempt was made to relate the variation of the cruciform weld profiles such as weld angle and weld toe radius to respective FAT classes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Screening for osteoporosis is important in older patients admitted to post-acute rehabilitation. However, DXA measurement is sometimes difficult to perform because of difficulties in positioning the patient and artefacts (osteoarthritis, prosthesis). The objectives were to determine the prevalence of unknown clinical osteoporosis in rehab patients and to determine new strategies for identifying clinical osteoporosis in this population. Method: Over a 9-months period, patients consecutively admitted to post-acute rehabilitation were included in th stdy. Patients with osteoporosis diagnosis, and those with terminal illness or severe physical limitations were excluded. Patients underwent Bone Mineral Density (BMD) by DXA and Vertebral Fracture Assessment (VFA). Clinical osteoporosis was defined as BMD ≤-2.5 SD at any site (lumbar spine, femoral neck, total hip or distal radius), ≥1 vertebral fracture, ≥1 hip fracture, or another fragility fracture and BMD ≤-2 SD. Results: Overall, 102 (17.0%) of the 600 patients admitted to rehab refused to participate in the study or were unable to consent. Among the 498 remaining patients, 99 (19.9%) were excluded because of already known diagnosis of osteoporosis, 101 (20.3%) were excluded because of terminal illness, severe physical limitations, and 45 (9.0%) because of inability to perform DXA during the stay (death, hospital transfer). Overall, 253 patients were assessed with DXA and VFA (166 women, mean age 83±7 years, mean BMI 27±6 kg/m2, and 87 men, mean age 82±6 yrs, mean BMI 27±5 kg/m2). Of these, 70% had history of fall during the last 6 months and 9.1% had hip fracture history. Prevalence of osteoporotic vertebral fracture was 36% in women and 32% in men. Overall, 152 (60.1%) patients had clinical osteoporosis (women: 67%; men: 46%) according to above criteria. Hip fracture history and vertebral fracture assessment identified correctly 105 (69.1%) of these 152 patients. Conclusion: A high prevalence of osteoporosis was observed in this population of rehab patients. Osteoporosis status should be systematically assessed in these patients at high fall risk, at least with careful history of hip fracture and an assessment for vertebral fractures with spine X-ray.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Controversy exists about the best method to achieve bone fusion in four-corner arthrodesis. Thirty-five patients who underwent this procedure by our technique were included in the study. Surgical indications were stage II-III SLAC wrist, stage II SNAC wrist and severe traumatic midcarpal joint injury. Mean follow-up was 4.6 years. Mean active flexion and extension were 34 degrees and 30 degrees respectively; grip strength recovery was 79%. Radiological consolidation was achieved in all cases. The mean DASH score was 23 and the postoperative pain improvement by visual analogue scale was statistically significant. Return to work was possible at 4 months for the average patient. Complications were a capitate fracture in one patient and the need for hardware removal in four cases. Four-corner bone wrist arthrodesis by dorsal rectangular plating achieves an acceptable preservation of range of motion with good pain relief, an excellent consolidation rate and minimal complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Yleisesti tiedetään hitsin pintageometrian vaikuttavan rakenteen väsymislujuuteen. Nopean, edullisen ja luotettavan pintageometrian mittausmenetelmän kehittäminen on askel kohti tarkempaa ja varmempaa rakenteen väsymislujuuden tarkastelua. Tässä työssä on tutkittu hitsejä, joiden pinnan geometria on mitattu norjalaisen SINTEF -yrityksen kehittämällä rakenteellisen valon menetelmällä. Osana työtä kehitettiin MatLab -pohjainen ohjelma, jolla jälkikäsitellään mittauksesta saadut x-y-z -mittapisteet. Mittausdatan jälkikäsittelyssä saadaan mittauksesta määritettyähitsin reunan pyöristys, liittymäkulma, a-mitta, reunahaava ja kateettisuhde. Kehitettyä menetelmää käyttämällä mitattiin lähes 300 voimaakantamatontaristiliitoksen hitsiä. Mittaustuloksia verrattiin vastaavista kappaleista tehtyihin hiemittauksiin. Manuaalisen hieestä tehdyn mittauksen havaittiin olevan tarkempi ja pystyttiin havaitsemaan paikallisempia muotoja. Rakenteellisen valon mittauksissa tapahtunut heijastelu saatiin pienenemään käsittelemällä mitattava pinta mattavalkoisella maalilla. Rakenteellisen valon mittatarkkuudeksi saatiin noin 0,2 mm. Pohjautuen mitattuun hitsin reunan pyöristykseen ja liittymäkulmaan voidaan yksinkertaista kaavaa käyttämällä laskea hitsin jännityskonsentraatio ja näin saada alkuarvaus väsymislujuudelle. Myös muiden tekijöiden tiedetään vaikuttavan hitsin väsymislujuuteen, joten pyöristyksen ja liittymäkulman avulla tehdyt arviot eivät ole absoluuttisen oikeita. Tämä havaittiin väsytyskokeilla, joista yhdessä väsymisvaurio ei syntynyt suurimmankaan jännityskonsentraation alueella.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Työssä on tutkittu vetojännityskuormituksen alaisena olevien hitsattujen kuormaa kantamattomien X-liitosten hitsin paikallisen geometrian variaation vaikutusta väsymislujuuteen. Muuttujina olivat reunan pyöristyssäde, kylmäjuoksun suuruus ja kylkikulma. Geometristen muuttujien parametrinen riippuvuussuhde on analysoitu usealla elementtimallilla. Väsymistarkastelu on suoritettu käyttämällä lineaaris-elastista murtumismekaniikkaa (LEFM) tasovenymätilassa ja materiaalina terästä. Särönkasvun suunnan ennustamisessaon käytetty maksimipääjännityskriteeriä sekä jännitysintensiteettikertoimet on määritetty J-integraalilla. Särön ydintymisvaihetta ei ole otettu huomioon. Rakenteen on oletettu olevan hitsatussa tilassa ja jännitysheilahdus on kokonaan tehollinen. Särön kasvunopeuden ennustamiseen on käytetty Paris'n lakia. Väsymislujuustulokset on esitetty karakteristisina väsymisluokkina (FAT) ja sovitettu parametriseksi yhtälöksi. Lopuksi väsymisanalyysin ennustamia tuloksia on verrattu saatavilla oleviin väsytystestituloksiin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: So far, none of the existing methods on Murray's law deal with the non-Newtonian behavior of blood flow although the non-Newtonian approach for blood flow modelling looks more accurate. MODELING: In the present paper, Murray's law which is applicable to an arterial bifurcation, is generalized to a non-Newtonian blood flow model (power-law model). When the vessel size reaches the capillary limitation, blood can be modeled using a non-Newtonian constitutive equation. It is assumed two different constraints in addition to the pumping power: the volume constraint or the surface constraint (related to the internal surface of the vessel). For a seek of generality, the relationships are given for an arbitrary number of daughter vessels. It is shown that for a cost function including the volume constraint, classical Murray's law remains valid (i.e. SigmaR(c) = cste with c = 3 is verified and is independent of n, the dimensionless index in the viscosity equation; R being the radius of the vessel). On the contrary, for a cost function including the surface constraint, different values of c may be calculated depending on the value of n. RESULTS: We find that c varies for blood from 2.42 to 3 depending on the constraint and the fluid properties. For the Newtonian model, the surface constraint leads to c = 2.5. The cost function (based on the surface constraint) can be related to entropy generation, by dividing it by the temperature. CONCLUSION: It is demonstrated that the entropy generated in all the daughter vessels is greater than the entropy generated in the parent vessel. Furthermore, it is shown that the difference of entropy generation between the parent and daughter vessels is smaller for a non-Newtonian fluid than for a Newtonian fluid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetic field dependencies of Hall coefficient and magnetoresistivity are investigated in classical and quantizing magnetic fields in p-Bi2Te3 crystals heavily doped with Sn grown by Czochralsky method. Magnetic field was parallel to the trigonal axis C3. Shubnikov-de Haas effect and quantum oscillations of the Hall coefficient were measured at temperatures 4.2 K and 11 K. On the basis of the magnetic field dependence of the Hall coefficient a method of estimation of the Hall factor and Hall mobility using the Drabble- Wolf six ellipsoid model is proposed. Shubnikov-de Haas effect and quantum oscillations of the Hall coefficient were observed at 4.2 K and 11 K. New evidence for the existence of the narrow band of Sn impurity states was shown. This band is partly filled by electrons and it is overlapping with the valence states of the light holes. Parameters of the impurity states, their energy ESn - 15 meV, band broadening ¿<< k0T and localization radius of the impuritystate R - 30 Å were obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Radiofrequency (RF) ablation is used to obtain local control of unresectable tumors in liver, kidney, prostate, and other organs. Accurate data on expected size and geometry of coagulation zones are essential for physicians to prevent collateral damage and local tumor recurrence. The aim of this study was to develop a standardized terminology to describe the size and geometry of these zones for experimental and clinical RF. METHODS: In a first step, the essential geometric parameters to accurately describe the coagulation zones and the spatial relationship between the coagulation zones and the electrodes were defined. In a second step, standard terms were assigned to each parameter. RESULTS: The proposed terms for single-electrode RF ablation include axial diameter, front margin, coagulation center, maximal and minimal radius, maximal and minimal transverse diameter, ellipticity index, and regularity index. In addition a subjective description of the general shape and regularity is recommended. CONCLUSIONS: Adoption of the proposed standardized description method may help to fill in the many gaps in our current knowledge of the size and geometry of RF coagulation zones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tools to predict fracture risk are useful for selecting patients for pharmacological therapy in order to reduce fracture risk and redirect limited healthcare resources to those who are most likely to benefit. FRAX® is a World Health Organization fracture risk assessment algorithm for estimating the 10-year probability of hip fracture and major osteoporotic fracture. Effective application of FRAX® in clinical practice requires a thorough understanding of its limitations as well as its utility. For some patients, FRAX® may underestimate or overestimate fracture risk. In order to address some of the common issues encountered with the use of FRAX® for individual patients, the International Society for Clinical Densitometry (ISCD) and International Osteoporosis Foundation (IOF) assigned task forces to review the medical evidence and make recommendations for optimal use of FRAX® in clinical practice. Among the issues addressed were the use of bone mineral density (BMD) measurements at skeletal sites other than the femoral neck, the use of technologies other than dual-energy X-ray absorptiometry, the use of FRAX® without BMD input, the use of FRAX® to monitor treatment, and the addition of the rate of bone loss as a clinical risk factor for FRAX®. The evidence and recommendations were presented to a panel of experts at the Joint ISCD-IOF FRAX® Position Development Conference, resulting in the development of Joint ISCD-IOF Official Positions addressing FRAX®-related issues.