975 resultados para positive predictive value
Resumo:
Inaccurate diagnosis of vulvovaginitis generates inadequate treatments that cause damages women's health. Objective: evaluate the effectiveness of methods when diagnosing vulvovaginitis. Method: a cross-sectional study was performed with 200 women who complained about vaginal discharge. Vaginal smear was collected for microbiological tests, considering the gram stain method as gold standard. The efficacy of the available methods for diagnosis of vaginal discharge was assessed (sensitivity, specificity, positive predictive value and negative predictive value). Data were inserted to Graphpad Prism 6, for statistical analysis. Results: the following results were obtained: wet mount for vaginal candidiasis: sensitivity = 31%; specificity = 97%; positive predictive value (PPV) = 54%; negative predictive value (NPV) =93%; accuracy = 91%. Wet mount for bacterial vaginosis: sensitivity = 80%; specificity =95%; positive predictive value (PPV) = 80%; negative predictive value (NPV) = 95%; accuracy = 92%. Syndromic approach for bacterial vaginosis: sensitivity = 95%; specificity=43%; positive predictive value (PPV) =30%; negative predictive value (NPV) = 97%; accuracy = 54%. Syndromic approach for vaginal candidiasis: sensitivity = 75%; specificity =91%; positive predictive value (PPV) = 26%; negative predictive value (NPV) = 98%; accuracy = 90%. Pap smear for vaginal candidiasis: sensitivity = 68%, specificity = 98%; positive predictive value (PPV) = 86%; negative predictive value (NPV) =96%; accuracy = 96%. Pap smear for bacterial vaginosis: sensitivity = 75%; specificity = 100%; positive predictive value (PPV) = 100%; negative predictive value (NPV) =94%; accuracy = 95%. There was only one case of vaginal trichomoniasis reported – diagnosed by oncological cytology and wet mount – confirmed by Gram. The syndromic approach diagnosed it as bacterial vaginosis. From the data generated and with support on world literature, the Maternidade Escola Januário Cicco’s vulvovaginitis protocol was constructed. Conclusion: Pap smear and wet mount showed respectively low and very low sensitivity for vaginal candidiasis. Syndromic approach presented very low specificity and accuracy for bacterial vaginosis, which implies a large number of patients who are diagnosed or treated incorrectly.
Resumo:
The goal of this study was to evaluate general medicine physicians' ability to predict hospital discharge. We prospectively asked study subjects to predict whether each patient under their care would be discharged on the next day, on the same day, or neither. Discharge predictions were recorded at 3 time points: mornings (7-9 am), midday (12-2 pm), or afternoons (5-7 pm), for a total of 2641 predictions. For predictions of next-day discharge, the sensitivity (SN) and positive predictive value (PPV) were lowest in the morning (27% and 33%, respectively), but increased by the afternoon (SN 67%, PPV 69%). Similarly, for same-day discharge predictions, SN and PPV were highest at midday (88% and 79%, respectively). We found that although physicians have difficulty predicting next-day discharges in the morning prior to the day of expected discharge, their ability to correctly predict discharges continually improved as the time to actual discharge decreased. Journal of Hospital Medicine 2015;10:808-810. © 2015 Society of Hospital Medicine.
Resumo:
Aims: Measurement of glycated hemoglobin (HbA1c) is an important indicator of glucose control over time. Point-of-care (POC) devices allow for rapid and convenient measurement of HbA1c, greatly facilitating diabetes care. We assessed two POC analyzers in the Peruvian Amazon where laboratory-based HbA1c testing is not available.
Methods: Venous blood samples were collected from 203 individuals from six different Amazonian communities with a wide range of HbA1c, 4.4-9.0% (25-75 mmol/mol). The results of the Afinion AS100 and the DCA Vantage POC analyzers were compared to a central laboratory using the Premier Hb9210 high-performance liquid chromatography (HPLC) method. Imprecision was assessed by performing 14 successive tests of a single blood sample.
Results: The correlation coefficient r for POC and HPLC results was 0.92 for the Afinion and 0.93 for the DCA Vantage. The Afinion generated higher HbA1c results than the HPLC (mean difference = +0.56% [+6 mmol/mol]; p < 0.001), as did the DCA Vantage (mean difference = +0.32% [4 mmol/mol]). The bias observed between POC and HPLC did not vary by HbA1c level for the DCA Vantage (p = 0.190), but it did for the Afinion (p < 0.001). Imprecision results were: CV = 1.75% for the Afinion, CV = 4.01% for the DCA Vantage. Sensitivity was 100% for both devices, specificity was 48.3% for the Afinion and 85.1% for the DCA Vantage, positive predictive value (PPV) was 14.4% for the Afinion and 34.9% for the DCA Vantage, and negative predictive value (NPV) for both devices was 100%. The area under the receiver operating characteristic (ROC) curve was 0.966 for the Afinion and 0.982 for the DCA Vantage. Agreement between HPLC and POC in classifying diabetes and prediabetes status was slight for the Afinion (Kappa = 0.12) and significantly different (McNemar’s statistic = 89; p < 0.001), and moderate for the DCA Vantage (Kappa = 0.45) and significantly different (McNemar’s statistic = 28; p < 0.001).
Conclusions: Despite significant variation of HbA1c results between the Afinion and DCA Vantage analyzers compared to HPLC, we conclude that both analyzers should be considered in health clinics in the Peruvian Amazon for therapeutic adjustments if healthcare workers are aware of the differences relative to testing in a clinical laboratory. However, imprecision and bias were not low enough to recommend either device for screening purposes, and the local prevalence of anemia and malaria may interfere with diagnostic determinations for a substantial portion of the population.
Resumo:
Objective: The study was designed to validate use of elec-tronic health records (EHRs) for diagnosing bipolar disorder and classifying control subjects. Method: EHR data were obtained from a health care system of more than 4.6 million patients spanning more than 20 years. Experienced clinicians reviewed charts to identify text features and coded data consistent or inconsistent with a diagnosis of bipolar disorder. Natural language processing was used to train a diagnostic algorithm with 95% specificity for classifying bipolar disorder. Filtered coded data were used to derive three additional classification rules for case subjects and one for control subjects. The positive predictive value (PPV) of EHR-based bipolar disorder and subphenotype di- agnoses was calculated against diagnoses from direct semi- structured interviews of 190 patients by trained clinicians blind to EHR diagnosis. Results: The PPV of bipolar disorder defined by natural language processing was 0.85. Coded classification based on strict filtering achieved a value of 0.79, but classifications based on less stringent criteria performed less well. No EHR- classified control subject received a diagnosis of bipolar dis- order on the basis of direct interview (PPV=1.0). For most subphenotypes, values exceeded 0.80. The EHR-based clas- sifications were used to accrue 4,500 bipolar disorder cases and 5,000 controls for genetic analyses. Conclusions: Semiautomated mining of EHRs can be used to ascertain bipolar disorder patients and control subjects with high specificity and predictive value compared with diagnostic interviews. EHRs provide a powerful resource for high-throughput phenotyping for genetic and clinical research.
Resumo:
Objectives: To investigate if the shading sign is an exclusive MRI feature of endometriomas or endometrioid tumors, and to analyze its different patterns. Methods: Three hundred and fourty six women with adnexal masses who underwent 1.5/3-T MRI were included in this retrospective, board-approved study. The shading sign was found in 56 patients, but five cases were excluded due to lack of imaging follow-up or histological correlation. The final sample included 51 women. The type of tumor and the pattern of shading were recorded for each case. Results: Thirty endometriomas and five endometrioid carcinomas were found. The remaining 16 cases corresponded to other benign and malignant tumors. The overall sensitivity, specificity, positive predictive value, and negative predictive value were 73%, 93%, 59%, and 96%, respectively. Restricting the analysis to cystic lesions without solid or fat component, sensitivity, specificity, positive predictive value, and negative predictive value were 73%, 96%, 94%, and 80%. Five shading patterns were identified: layering (15.7%), liquid–liquid level (11.8%), homogenous (45.1%), heterogeneous (11.8%), and focal/multifocal shading within a complex mass (19.6%). No significant correlation was found between these patterns and the type of tumor. Conclusions: The shading sign is not exclusive of endometriomas or endometrioid tumors. Homogenous shading was the most prevalent pattern in endometriomas and half of the cases with focal/multifocal shading within a complex mass were endometrioid carcinomas.
Resumo:
International audience
Resumo:
International audience
Resumo:
Background In 2009 Malawi introduced a new protocol to screen potential blood donors for anaemia, using the WHO Haemoglobin Colour Scale (HCS) for initial screening. Published studies of the accuracy of the HCS to screen potential blood donors show varying levels of accuracy and opinion varies whether this is an appropriate screening test. The aim of the study was to assess the validity of the HCS, as a screening test, by comparison to HemoCue in potential blood donors in Malawi. Study design and Methods This was a blinded prospective study in potential blood donors aged over 18 years, at Malawi Blood Transfusion Service in Blantyre, Malawi. Capillary blood samples were analysed using the HCS and HemoCue, independent of each other. The sensitivity and specificity of correctly identifying ineligible blood donors (Hb≤12g/dL) were calculated. Results From 242 participants 234 (96.7%) were correctly allocated and 8 (3.3%), were wrongly allocated on the basis of the Haemoglobin Colour Scale (HCS) compared to HemoCue, all were subjects that were wrongly accepted as donors when their haemoglobin results were ≤12.0g/dL. This gave a sensitivity of 100% and specificity of 96.7% to detect donor eligibilty. The negative predictive value of the HCS was 100% but the positive predictive value to identify ineligible donors on the basis of anaemia was only 20%. Conclusions Initial screening with the HCS correctly predicts eligibility for blood donation in the majority of potential blood donors at considerable cost saving compared with use of HemoCue as the first line anaemia screening test, however, by this method a small number of anaemic patients were allowed to donate blood.
Resumo:
Background: Hirschsprung’s disease (HD) is a congenital intestinal motility disorder with absence of ganglion cells in the colonic wall. Diagnosis of the disease is mainly based on the identification of the lack of ganglion cells in the pathology sections of the colon which is very difficult and time consuming and also needs several serial cut sections. There are many proposed markers in this field in the literature but none of them has been satisfactory. Calretinin immunohistochemistry (IHC) has been introduced as a new diagnostic marker to overcome the problems in diagnosis of this disease about 5 years ago. However there are few studies regarding the benefits and pitfalls of this marker. Objectives: The aim of this study is to determine the diagnostic value of calretinin IHC in detecting aganglionosis (HD). Patients and Methods: 27 HD patients and 28 non-Hirschsprung’s disease (NHD) patients were collected in a prospective study and calretinin IHC was performed on 31 aganglionic and 51 normoganglionic full wall thickness sections of colectomies (some of the cases had more than 1 section). The IHC slides were evaluated by two pathologists and the diagnostic value was calculated in comparison with gold standard which is the presence or absence of ganglion cells in serial Hematoxylin and Eosin (HE) stained sections of the colectomies. Results: There was great concordance between the final diagnosis of both pathologists and gold standard (k > 0.9). Calretinin immunostaining showed 100% specificity and positive predictive value and more than 90% sensitivity and negative predictive value. High agreement was present between the two pathologists (k > 0.9). Conclusions: Calretinin IHC is a very convenient, useful and valuable method to demonstrate aganglionosis in HD patients. Loss of calretinin immunostaining in lamina propria and submucosa is characteristic of HD.
Resumo:
Background: Incidence of jaundice is high in newborn infants. Since well appearing newborns are rapidly and routinely discharged from hospital, performing an inexpensive noninvasive pre-discharge screening test for evaluation of jaundice seems to be necessary. Objectives: This study was conducted to compare the accuracy of cutaneous v/s serum bilirubin measurements in this regard. Patients and Methods: This was a prospective cross sectional study conducted in Mahdieh hospital, Tehran. 613 neonates weighing ≥ 1,800 g with gestational age of ≥ 35 weeks were enrolled. A pre discharge transcutaneous bilirubin test (TcB) was performed in all. Serum samples were taken from neonates with TcB ≥ 5 mg/dL in first and > 8 mg/dL in second 24 hours. Decision for treatment or recheck of bilirubin level after discharge was made based on serum bilirubin results. Results: Based on the study protocol, among 613 studied neonates, 491 (80%) revealed high TcB, of them 240 (49%) cases showed TBC ≥ 5 mg/dL in first and 251 (51 %) in second pre-discharge 24 hours. TcB ranged 3.3 - 17.1, mean TcB in first 24 hours was 6.9 ± 1 .7 (mode 6) and in second 24 hours 9.1 ± 2.1 (mode 10). Of 491 neonates with high TcB, capillary serum sample was taken as the second step and 398 neonates revealed high total serum bilirubin (TsB) with the same protocol for TcB. 108 (27.1%) neonates showed TsB ≥ 5 mg/dL in first and 290 (72.9%) in second 24 hours. According to the study results TcB has a 81% positive predictive value (PPV) in diagnosis of hyperbilirubinemia. Correlation coefficient of TcB and TsB in highest rate is equal to 72% (P value < 0.001). Conclusions: TcB is an inexpensive, noninvasive and precise pre-discharge screening test for evaluation of hyperbilirubinemia, with a high PPV. It is highly recommended to be performed routinely due to high incidence of hyperbilirubinemia in neonates.
Resumo:
Purpose: To investigate the expression of Myt272-3 recombinant protein and also to predict a possible protein vaccine candidate against Mycobacterium tuberculosis . Methods: Myt272-3 protein was expressed in pET30a+-Myt272-3 clone. The purity of the protein was determined using Dynabeads® His-Tag Isolation & Pulldown. Protein sequence was analysed in silico using bioinformatics software for the prediction of allergenicity, antigenicity, MHC-I and MHC-II binding, and B-cell epitope binding. Results: The candidate protein was a non-allergen with 15.19 % positive predictive value. It was also predicted to be antigenic, with binding affinity to MHC-I and MHC-II, as well as B-cell epitope binding. Conclusion: The predicted results obtained in this study provide a guide for practical design of a new tuberculosis vaccine.
Resumo:
Background/Aims: The Mini Addenbrooke’s Cognitive Examination (M-ACE) is the abbreviated version of the widely-used Addenbrooke’s Cognitive Examination (ACE-III), a cognitive screening tool that is used internationally in the assessment of mild cognitive impairment (MCI) and dementia. The objectives of this study were to investigate the diagnostic accuracy of the M-ACE with individuals aged 75 and over to distinguish between those who do and do not have a dementia or MCI, and also to establish whether the cut-off scores recommended by Hsieh et al. (2014) [9] in the original validation study for the M-ACE are optimal for this age group. Methods: The M-ACE was administered to 58 participants (24 with a diagnosis of dementia, 17 with a diagnosis of MCI and 17 healthy controls). The extent to which scores distinguished between groups (dementia, MCI or no diagnosis) was explored using receiver operating characteristic curve analysis. Results: The optimal cut-off for detecting dementia was ≤ 21/30 (score ≤ 21/30 indicating dementia with a sensitivity of 0.95, a specificity of 1 and a positive predictive value of 1) compared to the original higher published cut-off of ≤ 25/30 (sensitivity of 0.95, specificity of 0.70 and a positive predictive value of 0.82 in this sample). Conclusions: The M-ACE has excellent diagnostic accuracy for the detection of dementia in a UK clinical sample. It may be necessary to consider lower cut-offs than those given in the original validation study.
Resumo:
La tuberculosis TB es una de las principales causas de muerte en el mundo en individuos con infección por VIH. En Colombia esta coinfección soporta una carga importante en la población general convirtiéndose en un problema de salud pública. En estos pacientes las pruebas diagnósticas tienen sensibilidad inferior y la enfermedad evoluciona con mayor frecuencia hacia formas diseminadas y rápidamente progresivas y su diagnóstico oportuno representa un reto en Salud. El objetivo de este proyecto es evaluar el desempeño de las pruebas diagnósticas convencionales y moleculares, para la detección de TB latente y activa pacientes con VIH, en dos hospitales públicos de Bogotá. Para TB latente se evaluó la concordancia entre las pruebas QuantiFERON-TB (QTF) y Tuberculina (PPD), sugiriendo superioridad del QTF sobre la PPD. Se evaluaron tres pruebas diagnósticas por su sensibilidad y especificidad, baciloscopia (BK), GenoType®MTBDR plus (Genotype) y PCR IS6110 teniendo como estándar de oro el cultivo. Los resultados de sensibilidad (S) y especificidad (E) de cada prueba con una prevalencia del 19,4 % de TB pulmonar y extrapulmonar en los pacientes que participaron del estudio fue: BK S: 64% E: 99,1%; Genotype S: 77,8% E: 94,5%; PCRIS6110 S: 73% E: 95,5%, de la misma forma se determinaron los valores predictivos positivos y negativos (VPP y VPN) BK: 88,9% y 94,8%, Genotype S: 77,8% E: 94,5%; PCRIS6110 S: 90% y 95,7%. Se concluyó bajo análisis de curva ROC que las pruebas muestran un rendimiento diagnóstico similar por separado en el diagnóstico de TB en pacientes con VIH, aumentando su rendimiento diagnostico cuando se combinan
Resumo:
Antecedentes: El cáncer gástrico se diagnostica tardíamente. Sólo en países como Corea y Japón existen políticas de tamizaje, que se justificarían en cualquier país con alta prevalencia de cáncer gástrico como Colombia o Chile. El análisis del pepsinógeno sérico se ha propuesto para el diagnóstico de lesiones premalignas y malignas gástricas, por lo cual se pretende revisar sistemáticamente en la literatura el valor diagnóstico del cociente pepsinógeno I/II como marcador de lesiones premalignas y malignas gástricas. Metodología: Se revisó la literatura hasta septiembre del 2016 con palabras claves lesiones malignas, premalignas gástricas y pepsinógeno en las bases de datos PubMed, OVID, EMBASE, EBSCO, LILACS, OPENGRAY y Dialnet, artículos de prueba diagnóstica que evaluaran el cociente pepsinógeno I/II en relación con los hallazgos histológicos. Resultados: Se incluyeron 21 artículos conun total de 20601 pacientes, que demuestranuna sensibilidad entre13.7% - 91.2%, una especificidad entre 38.5% - 100%, un Valor Predictivo Positivo entre 6.3% - 100% y un Valor Predictivo Negativo entre 33.3% - 98.8%del cociente pepsinógeno I/II en relación con el diagnósticode lesiones premalignas y malignas gástricas. Conclusiones: Los valores del cociente pepsinógeno I/II disminuidos se relacionan con la presencia delesiones premalignas y malignas gástricas.Dado que tiene mejor especificidad que sensibilidad, en cuanto prueba para tamizaje, sería útil para la selección de pacientes que se beneficiaríande la EVDA. Se requieren más estudios de prueba diagnóstica para validar un punto de corte específico que pueda ser utilizado como valor estándar.
Resumo:
The unresolved issue of false-positive D-dimer results in the diagnostic workup of pulmonary embolism Pulmonary embolism (PE) remains a difficult diagnosis as it lacks specific symptoms and clinical signs. After the determination of the pretest PE probability by a validated clinical score, D-dimers (DD) is the initial blood test in the majority of patients whose probability is low or intermediate. The low specificity of DD results in a high number of false-positives that then require thoracic angio-CT. A new clinical decision rule, called the Pulmonary Embolism Rule-out criteria (PERC), identifies patients at such low risk that PE can be safely ruled-out without a DD test. Its safety has been confirmed in US emergency departments, but retrospective European studies showed that it would lead to 5-7% of undiagnosed PE. Alternative strategies are needed to reduce the proportion of false-positive DD results.