774 resultados para noncontact corneal esthesiometry
Resumo:
Pioneer work on iontophoresis undertaken by David Maurice during the 1970s and 1980s laid the initial groundwork for its potential implementation as a promising ocular therapeutic modality. A better understanding of tissue interactions within the eye during electric current application, along with better designs of drug delivery devices have enabled us to pursue David Maurice's original ideas and take them from the bench to the bed side. In the present study we demonstrate the potential application of an iontophoresis device (Eyegate, Optis, France) for the treatment of certain human eye diseases. Seventeen patients received a penetrating keratoplasty (PKP) at various intervals before presentation with active graft rejection in our clinic and were treated using this iontophoresis device. Methylprednisolone sodium succinate (MP) 62.5 mg/ml was infused within the Eyegate ocular probe container and an electrical current of 1.5 mA was delivered for 4 min with the negative pole connected to the ocular probe. Patients were treated on an ambulatory basis and received a standard course of three iontophoresis applications given once a day over 3 consecutive days. After treatment, 15 of the 17 treated eyes (88%) demonstrated a complete reversal of the rejection processes. In two eyes, only a partial and temporary improvement was observed. The mean best corrected visual acuity of all 17 patients during the last follow up visit was 0.37 +/- 0.2 compared to 0.06 +/- 0.05 before initiation of the iontophoresis treatment. The mean follow-up time was 13.7 months with a range of 5-29 months for the 17 patients. No significant side-effects associated with the iontophoresis treatment were observed. Thus, for the management of active corneal graft rejection, iontophoresis of MP can be an alternative to very frequent instillations of eye drops, or to pulsed intravenous therapy of corticosteroids.
Resumo:
Systemic administration of cyclosporine A (CsA) is commonly used in the treatment of local ophthalmic conditions involving cytokines, such as corneal graft rejection, autoimmune uveitis and dry eye syndrome. Local administration is expected to avoid the various side effects associated with systemic delivery. However, the currently available systems using oils to deliver CsA topically are poorly tolerated and provide a low bioavailability. These difficulties may be overcome through formulations aimed at improving CsA water solubility (e.g. cyclodextrins), or those designed to facilitate tissue drug penetration using penetration enhancers. The use of colloidal carriers (micelles, emulsions, liposomes and nanoparticles) as well as the approach using hydrosoluble prodrugs of CsA have shown promising results. Solid devices such as shields and particles of collagen have been investigated to enhance retention time on the eye surface. Some of these topical formulations have shown efficacy in the treatment of extraocular diseases but were inefficient at reaching intraocular targets. Microspheres, implants and liposomes have been developed to be directly administered subconjunctivally or intravitreally in order to enhance CsA concentration in the vitreous. Although progress has been made, there is still room for improvement in CsA ocular application, as none of these formulations is ideal.
Resumo:
PURPOSE: Pharmacologic modulation of wound healing after glaucoma filtering surgery remains a major clinical challenge in ophthalmology. Poly(ortho ester) (POE) is a bioerodible and biocompatible viscous polymer potentially useful as a sustained drug delivery system that allows the frequency of intraocular injections to be reduced. The purpose of this study was to determine the efficacy of POE containing a precise amount of 5-fluorouracil (5-FU) in an experimental model of filtering surgery in the rabbit. METHODS: Trabeculectomy was performed in pigmented rabbit eyes. An ointmentlike formulation of POE containing 1% wt/wt 5-FU was injected subconjunctivally at the site of surgery, during the procedure. Intraocular pressure (IOP), bleb persistence, and ocular inflammatory reaction were monitored until postoperative day 30. Quantitative analysis of 5-FU was performed in the anterior chamber. Histologic analysis was used to assess the appearance of the filtering fistula and the polymer's biocompatibility. RESULTS: The decrease in IOP from baseline and the persistence of the filtering bleb were significantly more marked in the 5-FU-treated eyes during postoperative days 9 through 28. Corneal toxicity triggered by 5-FU was significantly lower in the group that received 5-FU in POE compared with a 5-FU tamponade. Histopathologic evaluation showed that POE was well tolerated, and no fibrosis occurred in eyes treated with POE containing 5-FU. CONCLUSIONS: In this rabbit model of trabeculectomy, the formulation based on POE and containing a precise amount of 5-FU reduced IOP and prolonged bleb persistence in a way similar to the conventional method of a 5-FU tamponade, while significantly reducing 5-FU toxicity.
Resumo:
Bone marrow-derived endothelial progenitor cells (EPCs) infiltrate into sites of neovascularization in adult tissues and mature into functional blood endothelial cells (BECs) during a process called vasculogenesis. Human marrow-derived EPCs have recently been reported to display a mixed myeloid and lymphatic endothelial cell (LEC) phenotype during inflammation-induced angiogenesis; however, their role in cancer remains poorly understood. We report the in vitro differentiation of human cord blood CD133(+)CD34(+) progenitors into podoplanin(+) cells expressing both myeloid markers (CD11b, CD14) and the canonical LEC markers vascular endothelium growth factor receptor 3 (VEGFR-3), lymphatic vessel endothelial hyaluronan receptor 1 (LYVE-1), and prospero homeobox 1 (PROX-1). These podoplanin(+) cells displayed sprouting behavior comparable to that of LECs in vitro and a dual hemangiogenic and lymphangiogenic activity in vivo in an endothelial cell sprouting assay and corneal vascularization assay, respectively. Furthermore, these cells expressed vascular endothelium growth factor (VEGF) family members A, -C, and -D. Thus, bone-marrow derived EPCs stimulate hemangiogenesis and lymphangiogenesis through their ability to differentiate into LECs and to produce angiogenic factors. Importantly, plasma from patients with breast cancer induced differentiation of CD34(+) cord blood progenitors into hemangiogenic and lymphangiogenic CD11b(+) myeloid cells, whereas plasma from healthy women did not have this effect. Consistent with these findings, circulating CD11b(+) cells from breast cancer patients, but not from healthy women, displayed a similar dual angiogenic activity. Taken together, our results show that marrow-derived EPCs become hemangiogenic and lymphangiogenic upon exposure to cancer plasma. These newly identified functions of bone-marrow derived EPCs are expected to influence the diagnosis and treatment of breast cancer.
Resumo:
We report a case of xeroderma pigmentosum in a 9-year-old back Cameroonian boy. The diagnosis was based on typical clinical presentation of the disease: cutaneous atrophy, hypepigmented macules, and areas of depigmentation on sun exposed regions of the skin. Multiple tumoral lesions were localized on the head. Ocular findings were also present: conjunctival hyperemia, peripheral corneal opacification. Excision of the tumors and potoprotection was proposed for this patient. The role of tribal black African marriage traditions in disease transmission is discussed.
Resumo:
We wished to evaluate the potential of iontophoresis to promote the delivery of antisense oligonucleotides (ODN) directed at the vascular endothelial growth factor (VEGF)-R2 receptor (KDR/Flk) to the cornea of the rat eye. Fluorescence (CY5)-labeled ODNs in phosphate-buffered saline (PBS) (20 microM) were locally administered to rat eyes, and their fate within the anterior segment was studied. Thirty-four male, 5-week-old Wistar rats were used for all experiments. The rats were divided in four groups. In group I (12 rats, 12 eyes), the ODNs (20 microM) were delivered by iontophoresis (300 microA for 5 minutes) using a specially designed corneal applicator. In group II (12 rats, 12 eyes), the ODNs (20 microM) were delivered using the same applicator, but no electrical current was applied. In group III (6 rats, 6 eyes), a corneal neovascular reaction was induced prior to the application of ODNs (20 microM), and iontophoresis electrical current was delivered as for group I rats. Group IV (4 rats, 4 eyes) received ODN (60 microM) iontophoresis application (300 microA for 5 minutes) and were used for ODN integrity studies. The animals were killed 5 minutes, 90 minutes, and 24 hours after a single ODN application and studied. Topically applied ODNs using the same iontophoresis applicator but without current do not penetrate the cornea and remain confined to the superficial epithelial layer. ODNs delivered with transcorneoscleral iontophoresis penetrate into all corneal layers and are also detected in the iris. In corneas with neovascularization, ODNs were particularly localized within the vascular endothelial cells of the stroma. ODNs extracted from eye tissues 24 hours after iontophoresis remained unaltered. The iontophoresis current did not cause any detectable ocular damage under these conditions. Iontophoresis promotes the delivery of ODNs to the anterior segment of the eye, including all corneal layers. Iontophoresis of ODNs directed at VEGF-R2 may be used for the design of specific antiangiogenic strategy in diseases of the cornea.
Resumo:
The active magnetic bearings have recently been intensively developed because of noncontact support having several advantages compared to conventional bearings. Due to improved materials, strategies of control, and electrical components, the performance and reliability of the active magnetic bearings are improving. However, additional bearings, retainer bearings, still have a vital role in the applications of the active magnetic bearings. The most crucial moment when the retainer bearings are needed is when the rotor drops from the active magnetic bearings on the retainer bearings due to component or power failure. Without appropriate knowledge of the retainer bearings, there is a chance that an active magnetic bearing supported rotor system will be fatal in a drop-down situation. This study introduces a detailed simulation model of a rotor system in order to describe a rotor drop-down situation on the retainer bearings. The introduced simulation model couples a finite element model with component mode synthesis and detailed bearing models. In this study, electrical components and electromechanical forces are not in the focus. The research looks at the theoretical background of the finite element method with component mode synthesis that can be used in the dynamic analysis of flexible rotors. The retainer bearings are described by using two ball bearing models, which include damping and stiffness properties, oil film, inertia of rolling elements and friction between races and rolling elements. Thefirst bearing model assumes that the cage of the bearing is ideal and that the cage holds the balls in their predefined positions precisely. The second bearing model is an extension of the first model and describes the behavior of the cageless bearing. In the bearing model, each ball is described by using two degrees of freedom. The models introduced in this study are verified with a corresponding actual structure. By using verified bearing models, the effects of the parameters of the rotor system onits dynamics during emergency stops are examined. As shown in this study, the misalignment of the retainer bearings has a significant influence on the behavior of the rotor system in a drop-down situation. In this study, a stability map of the rotor system as a function of rotational speed of the rotor and the misalignment of the retainer bearings is presented. In addition, the effects of parameters of the simulation procedure and the rotor system on the dynamics of system are studied.
Resumo:
For landline telephone surveys in particular, undercoverage has been a growing problem. However, research regarding the relative contributions of socio-demographic bias and other composition effects is scarce. We propose to address this issue by analyzing an election survey which used a sample from a register-based sampling frame containing basic socio-demographic information and to which telephone numbers were subsequently matched. With respect to socio-demographic representation of the final sample, we find that difficult to match groups are also difficult to contact, while those who cooperate tend to have different characteristics. We find bias due to undercoverage to be of greater magnitude than noncontact bias, while noncooperation falls between the two. As for substantive variables, both additional efforts to match missing telephone numbers and the construction of better weights are successful in closing the gap between survey estimates of voting behavior and true values from the election results.
Resumo:
Nipple-like nanostructures covering the corneal surfaces of moths, butterflies, and Drosophila have been studied by electron and atomic force microscopy, and their antireflective properties have been described. In contrast, corneal nanostructures of the majority of other insect orders have either been unexamined or examined by methods that did not allow precise morphological characterization. Here we provide a comprehensive analysis of corneal surfaces in 23 insect orders, revealing a rich diversity of insect corneal nanocoatings. These nanocoatings are categorized into four major morphological patterns and various transitions between them, many, to our knowledge, never described before. Remarkably, this unexpectedly diverse range of the corneal nanostructures replicates the complete set of Turing patterns, thus likely being a result of processes similar to those modeled by Alan Turing in his famous reaction-diffusion system. These findings reveal a beautiful diversity of insect corneal nanostructures and shed light on their molecular origin and evolutionary diversification. They may also be the first-ever biological example of Turing nanopatterns.
Resumo:
BIGH3 is a secreted protein, part of the extracellular matrix where it interacts with collagen and integrins on the cell surface. BIGH3 can play opposing roles in cancer, acting as either tumor suppressor or promoter, and its mutations lead to different forms of corneal dystrophy. Although many studies have been carried out, little is known about the physiological role of BIGH3. Using the cre-loxP system, we generated a mouse model with disruption of the Bigh3 genomic locus. Bigh3 silencing did not result in any apparent phenotype modifications, the mice remained viable and fertile. We were able to determine the presence of BIGH3 in the retinal pigment epithelium (RPE). In the absence of BIGH3, a transient decrease in the apoptotic process involved in retina maturation was observed, leading to a transient increase in the INL thickness at P15. This phenomenon was accompanied by an increased activity of the pro-survival ERK pathway.
Resumo:
PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.
Resumo:
The aim of this study was to prospectively assess the prevalence of orthoptic anomalies following conservative management of pure blowout orbital fractures and to evaluate their clinical relevance. Clinical and radiologic data of patients with unilateral conservatively managed pure blowout orbital fractures with a minimum follow-up of 6 months were reviewed. Eligible patients were contacted and invited to undergo an extended ophthalmologic examination as follows: distance and near visual acuities, Hertel exophthalmometry, corneal light reflex (Hirschberg test), ductions and versions in the 6 cardinal fields of gaze, eye deviation with prisms and alternate cover test in all of the 9-gaze directions with Maddox rod, degrees of incyclo/excyclotorsion with right and left eye fixation, horizontal and vertical deviation with Hess-Weiss coordimetry, degree of horizontal/vertical and incyclo/excyclotorsion deviation with Harms wall deviometry, and vertical deviation with Bielschowsky head-tilt test. Of the 69 patients contacted, 49 declined to participate given that they were asymptomatic. Twenty patients agreed to undergo the examination. One patient complained of minimal double vision limited to the extreme downgaze. Four patients had asymptomatic ocular motility disturbances limited to the extreme gaze. Seven patients had asymptomatic horizontal heterophoria. These disturbances did not interfere with daily or professional activities in any of the patients. The current study demonstrated that conservative management of pure orbital blowout fractures can result in orthoptic anomalies. These sequelae were restricted to a very limited portion of the binocular field of the vision and were not found to be clinically relevant.
Resumo:
Sixty-one animals with different Halothane genes (homozygous halothane positive, n=34; and homozygous halothane negative, n=27) were fed with three diets (controlgroup, with no supplement; magnesium (Mg) group with 1.28g MgCO3/kg and tryptophan (Trp) group with 5g L-Trp/kg) during the last 5 days before slaughter. Animals were submitted to minimal stress ante mortem conditions. Pig behaviour was recorded at the experimental farm, raceway to the CO2 stunning system and during the stunning period. Corneal reflexes were recorded after stunning as well. There were no differences in feed intake among diets (p>0.05) during the 5 days of treatment. Thehalothane positive (nn) group had lower intake than the halothane negative (NN) group(p<0.01). The behaviour of the pigs in the raceway did not differ (p>0.05) among treatments or halothane genotype. A significant (p<0.001) interaction diet*halothane was found in the time to appear the first retreat attempt during the exposure to the CO2 system. In the nn group, the time of performing the first retreat attempt was later in the Mg (p<0.05) than the Control group. Moreover, in the Mg group, the nn had a later (p<0.05) first retreat attempt than the NN. Thus, Mg supplementation could have a positive effect on welfare of nn pigs. The nn had a lower proportion of animals thatshowed corneal reflexes after stunning than NN, indicating a higher effectiveness of thestunning method in nn pigs. Neither Mg nor Trp affected carcass quality and meat quality parameters, although significant differences were found between genotypes
Resumo:
An outbreak of hepatogenous photosensitization is reported in a flock of 28 sheep grazing Brachiaria decumbens in Mato Grosso do Sul State, Central-Western Brazil. Seven lambs and an adult sheep were affected and 6 of them died. Two surviving affected lambs and one lamb without clinical signs had increased serum values of gamma glutamyltransferase, bilirubin, and cholesterol. In two adult unaffected sheep those parameters were within normal values. An adult sheep submitted to necropsy presented moderate body condition, unilateral corneal opacity, drying of the muzzle, moderate jaundice, increased lobular pattern of the liver, and a distended gallbladder. Histological lesions were epithelial degeneration, necrosis, and hyperplasia of small bile ducts. Mild amounts of foamy macrophages were observed, mainly in the centroacinar zone. Diffuse swelling and vacuolation were observed in hepatocytes. Crystal negative images were found within bile ducts, foamy macrophages, and the lumen of some renal tubules. The heart showed multifocal areas of degeneration and necrosis of the muscle fibers. Pasture samples (Brachiaria decumbens) contained 2.36% of protodioscin. No Pithomyces chartarum spores were found in the pasture. Samples from a similar neighboring B. decumbens pasture grazed by cattle without photosensitization contained 1.63% of protodioscin isomers. Outbreaks of photosensitization caused by Brachiaria spp. are common in cattle in the Brazilian Cerrado (savanna) with about 51 million hectares of Brachiaria spp pastures. Sheep farming has been recently developed in this region, and the number of sheep is increasing significantly. Because sheep are more susceptible than cattle to lithogenic saponins, poisoning by Brachiaria should be an important limiting factor for the sheep industry.