947 resultados para method comparison
Resumo:
The purpose of this study was to apply and compare two time-domain analysis procedures in the determination of oxygen uptake (VO2) kinetics in response to a pseudorandom binary sequence (PRBS) exercise test. PRBS exercise tests have typically been analysed in the frequency domain. However, the complex interpretation of frequency responses may have limited the application of this procedure in both sporting and clinical contexts, where a single time measurement would facilitate subject comparison. The relative potential of both a mean response time (MRT) and a peak cross-correlation time (PCCT) was investigated. This study was divided into two parts: a test-retest reliability study (part A), in which 10 healthy male subjects completed two identical PRBS exercise tests, and a comparison of the VO2 kinetics of 12 elite endurance runners (ER) and 12 elite sprinters (SR; part B). In part A, 95% limits of agreement were calculated for comparison between MRT and PCCT. The results of part A showed no significant difference between test and retest as assessed by MRT [mean (SD) 42.2 (4.2) s and 43.8 (6.9) s] or by PCCT [21.8 (3.7) s and 22.7 (4.5) s]. Measurement error (%) was lower for MRT in comparison with PCCT (16% and 25%, respectively). In part B of the study, the VO2 kinetics of ER were significantly faster than those of SR, as assessed by MRT [33.4 (3.4) s and 39.9 (7.1) s, respectively; P<0.01] and PCCT [20.9 (3.8) s and 24.8 (4.5) s; P < 0.05]. It is possible that either analysis procedure could provide a single test measurement Of VO2 kinetics; however, the greater reliability of the MRT data suggests that this method has more potential for development in the assessment Of VO2 kinetics by PRBS exercise testing.
Resumo:
The assessment of cellular effects by the aqueous phase of human feces (fecal water, FW) is a useful biomarker approach to study cancer risks and protective activities of food. In order to refine and develop the biomarker, different protocols of preparing FW were compared. Fecal waters were prepared by 3 methods: (A) direct centrifugation; (B) extraction of feces in PBS before centrifugation; and (C) centrifugation of lyophilized and reconstituted feces. Genotoxicity was determined in colon cells using the Comet assay. Selected samples were investigated for additional parameters related to carcinogenesis. Two of 7 FWs obtained by methods A and B were similarly genotoxic. Method B, however, yielded higher volumes of FW, allowing sterile filtration for long-term culture experiments. Four of 7 samples were non-genotoxic when prepared according to all 3 methods. FW from lyophilized feces and from fresh samples were equally genotoxic. FWs modulated cytotoxicity, paracellular permeability, and invasion, independent of their genotoxicity. All 3 methods of FW preparation can be used to assess genotoxicity. The higher volumes of FWobtained by preparation method B greatly enhance the perspectives of measuring different types of biological parameters and using these to disclose activities related to cancer development.
Resumo:
A method is described for the analysis of deuterated and undeuterated alpha-tocopherol in blood components using liquid chromatography coupled to an orthogonal acceleration time-of-flight (TOF) mass spectrometer. Optimal ionisation conditions for undeuterated (d0) and tri- and hexadeuterated (d3 or d6) alpha-tocopherol standards were found with negative ion mode electrospray ionisation. Each species produced an isotopically resolved single ion of exact mass. Calibration curves of pure standards were linear in the range tested (0-1.5 muM, 0-15 pmol injected). For quantification of d0 and d6 in blood components following a standard solvent extraction, a stable-isotope-labelled internal standard (d3-alpha-tocopherol) was employed. To counter matrix ion suppression effects, standard response curves were generated following identical solvent extraction procedures to those of the samples. Within-day and between-day precision were determined for quantification of d0- and d6-labelled alpha-tocopherol in each blood component and both averaged 3-10%. Accuracy was assessed by comparison with a standard high-performance liquid chromatography (HPLC) method, achieving good correlation (r(2) = 0.94), and by spiking with known concentrations of alpha-tocopherol (98% accuracy). Limits of detection and quantification were determined to be 5 and 50 fmol injected, respectively. The assay was used to measure the appearance and disappearance of deuterium-labelled alpha-tocopherol in human blood components following deuterium-labelled (d6) RRR-alpha-tocopheryl acetate ingestion. The new LC/TOFMS method was found to be sensitive, required small sample volumes, was reproducible and robust, and was capable of high throughput when large numbers of samples were generated. Copyright (C) 2003 John Wiley Sons, Ltd.
Resumo:
A common method for testing preference for objects is to determine which of a pair of objects is approached first in a paired-choice paradigm. In comparison, many studies of preference for environmental enrichment (EE) devices have used paradigms in which total time spent with each of a pair of objects is used to determine preference. While each of these paradigms gives a specific measure of the preference for one object in comparison to another, neither method allows comparisons between multiple objects simultaneously. Since it is possible that several EE objects would be placed in a cage together to improve animal welfare, it is important to determine measures for rats' preferences in conditions that mimic this potential home cage environment. While it would be predicted that each type of measure would produce similar rankings of objects, this has never been tested empirically. In this study, we compared two paradigms: EE objects were either presented in pairs (paired-choice comparison) or four objects were presented simultaneously (simultaneous presentation comparison). We used frequency of first interaction and time spent with each object to rank the objects in the paired-choice experiment, and time spent with each object to rank the objects in the simultaneous presentation experiment. We also considered the behaviours elicited by the objects to determine if these might be contributing to object preference. We demonstrated that object ranking based on time spent with objects from the paired-choice experiment predicted object ranking in the simultaneous presentation experiment. Additionally, we confirmed that behaviours elicited were an important determinant of time spent with an object. This provides convergent evidence that both paired choice and simultaneous comparisons provide valid measures of preference for EE objects in rats. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Most active-contour methods are based either on maximizing the image contrast under the contour or on minimizing the sum of squared distances between contour and image 'features'. The Marginalized Likelihood Ratio (MLR) contour model uses a contrast-based measure of goodness-of-fit for the contour and thus falls into the first class. The point of departure from previous models consists in marginalizing this contrast measure over unmodelled shape variations. The MLR model naturally leads to the EM Contour algorithm, in which pose optimization is carried out by iterated least-squares, as in feature-based contour methods. The difference with respect to other feature-based algorithms is that the EM Contour algorithm minimizes squared distances from Bayes least-squares (marginalized) estimates of contour locations, rather than from 'strongest features' in the neighborhood of the contour. Within the framework of the MLR model, alternatives to the EM algorithm can also be derived: one of these alternatives is the empirical-information method. Tracking experiments demonstrate the robustness of pose estimates given by the MLR model, and support the theoretical expectation that the EM Contour algorithm is more robust than either feature-based methods or the empirical-information method. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
In this paper we consider bilinear forms of matrix polynomials and show that these polynomials can be used to construct solutions for the problems of solving systems of linear algebraic equations, matrix inversion and finding extremal eigenvalues. An almost Optimal Monte Carlo (MAO) algorithm for computing bilinear forms of matrix polynomials is presented. Results for the computational costs of a balanced algorithm for computing the bilinear form of a matrix power is presented, i.e., an algorithm for which probability and systematic errors are of the same order, and this is compared with the computational cost for a corresponding deterministic method.
Resumo:
The collection efficiency of two widely used gunshot residue (GSR) collection techniques—carbon-coated adhesive stubs and alcohol swabs—has been compared by counting the number of characteristic GSR particles collected from the firing hand of a shooter after firing one round. Samples were analyzed with both scanning electron microscopy and energy dispersive X-rays by an experienced GSR analyst, and the number of particles on each sample containing Pb, Ba, and Sb counted. The adhesive stubs showed a greater collection efficiency as all 24 samples gave positive results for GSR particles whereas the swabs gave only positive results for half of the 24 samples. Results showed a statistically significant collection efficiency for the stub collection method and likely reasons for this are considered.
Resumo:
A method of estimating dissipation rates from a vertically pointing Doppler lidar with high temporal and spatial resolution has been evaluated by comparison with independent measurements derived from a balloon-borne sonic anemometer. This method utilizes the variance of the mean Doppler velocity from a number of sequential samples and requires an estimate of the horizontal wind speed. The noise contribution to the variance can be estimated from the observed signal-to-noise ratio and removed where appropriate. The relative size of the noise variance to the observed variance provides a measure of the confidence in the retrieval. Comparison with in situ dissipation rates derived from the balloon-borne sonic anemometer reveal that this particular Doppler lidar is capable of retrieving dissipation rates over a range of at least three orders of magnitude. This method is most suitable for retrieval of dissipation rates within the convective well-mixed boundary layer where the scales of motion that the Doppler lidar probes remain well within the inertial subrange. Caution must be applied when estimating dissipation rates in more quiescent conditions. For the particular Doppler lidar described here, the selection of suitably short integration times will permit this method to be applicable in such situations but at the expense of accuracy in the Doppler velocity estimates. The two case studies presented here suggest that, with profiles every 4 s, reliable estimates of ϵ can be derived to within at least an order of magnitude throughout almost all of the lowest 2 km and, in the convective boundary layer, to within 50%. Increasing the integration time for individual profiles to 30 s can improve the accuracy substantially but potentially confines retrievals to within the convective boundary layer. Therefore, optimization of certain instrument parameters may be required for specific implementations.
Resumo:
With the rapid development of proteomics, a number of different methods appeared for the basic task of protein identification. We made a simple comparison between a common liquid chromatography-tandem mass spectrometry (LC-MS/MS) workflow using an ion trap mass spectrometer and a combined LC-MS and LC-MS/MS method using Fourier transform ion cyclotron resonance (FTICR) mass spectrometry and accurate peptide masses. To compare the two methods for protein identification, we grew and extracted proteins from E. coli using established protocols. Cystines were reduced and alkylated, and proteins digested by trypsin. The resulting peptide mixtures were separated by reversed-phase liquid chromatography using a 4 h gradient from 0 to 50% acetonitrile over a C18 reversed-phase column. The LC separation was coupled on-line to either a Bruker Esquire HCT ion trap or a Bruker 7 tesla APEX-Qe Qh-FTICR hybrid mass spectrometer. Data-dependent Qh-FTICR-MS/MS spectra were acquired using the quadrupole mass filter and collisionally induced dissociation into the external hexapole trap. Proteins were in both schemes identified by Mascot MS/MS ion searches and the peptides identified from these proteins in the FTICR MS/MS data were used for automatic internal calibration of the FTICR-MS data, together with ambient polydimethylcyclosiloxane ions.
Resumo:
A revised Bayesian algorithm for estimating surface rain rate, convective rain proportion, and latent heating profiles from satellite-borne passive microwave radiometer observations over ocean backgrounds is described. The algorithm searches a large database of cloud-radiative model simulations to find cloud profiles that are radiatively consistent with a given set of microwave radiance measurements. The properties of these radiatively consistent profiles are then composited to obtain best estimates of the observed properties. The revised algorithm is supported by an expanded and more physically consistent database of cloud-radiative model simulations. The algorithm also features a better quantification of the convective and nonconvective contributions to total rainfall, a new geographic database, and an improved representation of background radiances in rain-free regions. Bias and random error estimates are derived from applications of the algorithm to synthetic radiance data, based upon a subset of cloud-resolving model simulations, and from the Bayesian formulation itself. Synthetic rain-rate and latent heating estimates exhibit a trend of high (low) bias for low (high) retrieved values. The Bayesian estimates of random error are propagated to represent errors at coarser time and space resolutions, based upon applications of the algorithm to TRMM Microwave Imager (TMI) data. Errors in TMI instantaneous rain-rate estimates at 0.5°-resolution range from approximately 50% at 1 mm h−1 to 20% at 14 mm h−1. Errors in collocated spaceborne radar rain-rate estimates are roughly 50%–80% of the TMI errors at this resolution. The estimated algorithm random error in TMI rain rates at monthly, 2.5° resolution is relatively small (less than 6% at 5 mm day−1) in comparison with the random error resulting from infrequent satellite temporal sampling (8%–35% at the same rain rate). Percentage errors resulting from sampling decrease with increasing rain rate, and sampling errors in latent heating rates follow the same trend. Averaging over 3 months reduces sampling errors in rain rates to 6%–15% at 5 mm day−1, with proportionate reductions in latent heating sampling errors.
Resumo:
Experimentally and theoretically determined infrared spectra are reported for a series of straight-chain perfluorocarbons: C2F6, C3F8, C4F10, C5F12, C6F14, and C8F18. Theoretical spectra were determined using both density functional (DFT) and ab initio methods. Radiative efficiencies (REs) were determined using the method of Pinnock et al. (1995) and combined with atmospheric lifetimes from the literature to determine global warming potentials (GWPs). Theoretically determined absorption cross sections were within 10% of experimentally determined values. Despite being much less computationally expensive, DFT calculations were generally found to perform better than ab initio methods. There is a strong wavenumber dependence of radiative forcing in the region of the fundamental C-F vibration, and small differences in wavelength between band positions determined by theory and experiment have a significant impact on the REs. We apply an empirical correction to the theoretical spectra and then test this correction on a number of branched chain and cyclic perfluoroalkanes. We then compute absorption cross sections, REs, and GWPs for an additional set of perfluoroalkenes.
Resumo:
We have estimated the speed and direction of propagation of a number of Coronal Mass Ejections (CMEs) using single-spacecraft data from the STEREO Heliospheric Imager (HI) wide-field cameras. In general, these values are in good agreement with those predicted by Thernisien, Vourlidas, and Howard in Solar Phys. 256, 111 -aEuro parts per thousand 130 (2009) using a forward modelling method to fit CMEs imaged by the STEREO COR2 coronagraphs. The directions of the CMEs predicted by both techniques are in good agreement despite the fact that many of the CMEs under study travel in directions that cause them to fade rapidly in the HI images. The velocities estimated from both techniques are in general agreement although there are some interesting differences that may provide evidence for the influence of the ambient solar wind on the speed of CMEs. The majority of CMEs with a velocity estimated to be below 400 km s(-1) in the COR2 field of view have higher estimated velocities in the HI field of view, while, conversely, those with COR2 velocities estimated to be above 400 km s(-1) have lower estimated HI velocities. We interpret this as evidence for the deceleration of fast CMEs and the acceleration of slower CMEs by interaction with the ambient solar wind beyond the COR2 field of view. We also show that the uncertainties in our derived parameters are influenced by the range of elongations over which each CME can be tracked. In order to reduce the uncertainty in the predicted arrival time of a CME at 1 Astronomical Unit (AU) to within six hours, the CME needs to be tracked out to at least 30 degrees elongation. This is in good agreement with predictions of the accuracy of our technique based on Monte Carlo simulations.
Resumo:
The intensity and distribution of daily precipitation is predicted to change under scenarios of increased greenhouse gases (GHGs). In this paper, we analyse the ability of HadCM2, a general circulation model (GCM), and a high-resolution regional climate model (RCM), both developed at the Met Office's Hadley Centre, to simulate extreme daily precipitation by reference to observations. A detailed analysis of daily precipitation is made at two UK grid boxes, where probabilities of reaching daily thresholds in the GCM and RCM are compared with observations. We find that the RCM generally overpredicts probabilities of extreme daily precipitation but that, when the GCM and RCM simulated values are scaled to have the same mean as the observations, the RCM captures the upper-tail distribution more realistically. To compare regional changes in daily precipitation in the GHG-forced period 2080-2100 in the GCM and the RCM, we develop two methods. The first considers the fractional changes in probability of local daily precipitation reaching or exceeding a fixed 15 mm threshold in the anomaly climate compared with the control. The second method uses the upper one-percentile of the control at each point as the threshold. Agreement between the models is better in both seasons with the latter method, which we suggest may be more useful when considering larger scale spatial changes. On average, the probability of precipitation exceeding the 1% threshold increases by a factor of 2.5 (GCM and RCM) in winter and by I .7 (GCM) or 1.3 (RCM) in summer.
Resumo:
Sensitive methods that are currently used to monitor proteolysis by plasmin in milk are limited due to 7 their high cost and lack of standardisation for quality assurance in the various dairy laboratories. In 8 this study, four methods, trinitrobenzene sulphonic acid (TNBS), reverse phase high pressure liquid 9 chromatography (RP-HPLC), gel electrophoresis and fluorescamine, were selected to assess their 10 suitability for the detection of proteolysis in milk by plasmin. Commercial UHT milk was incubated 11 with plasmin at 37 °C for one week. Clarification was achieved by isoelectric precipitation (pH 4·6 12 soluble extracts)or 6% (final concentration) trichloroacetic acid (TCA). The pH 4·6 and 6% TCA 13 soluble extracts of milk showed high correlations (R2 > 0·93) by the TNBS, fluorescamine and 14 RP-HPLC methods, confirming increased proteolysis during storage. For gel electrophoresis,15 extensive proteolysis was confirmed by the disappearance of α- and β-casein bands on the seventh 16 day, which was more evident in the highest plasmin concentration. This was accompanied by the 17 appearance of α- and β-casein proteolysis products with higher intensities than on previous days, 18 implying that more products had been formed as a result of casein breakdown. The fluorescamine 19 method had a lower detection limit compared with the other methods, whereas gel electrophoresis 20 was the best qualitative method for monitoring β-casein proteolysis products. Although HPLC was the 21 most sensitive, the TNBS method is recommended for use in routine laboratory analysis on the basis 22 of its accuracy, reliability and simplicity.
Resumo:
Integrated Arable Farming Systems (IAFS), which involve a reduction in the use of off-farm inputs, are attracting considerable research interest in the UK. The objectives of these systems experiments are to compare their financial performance with that from conventional or current farming practices. To date, this comparison has taken little account of any environmental benefits (or disbenefits) of the two systems. The objective of this paper is to review the assessment methodologies available for the analysis of environmental impacts. To illustrate the results of this exercise, the methodology and environmental indicators chosen are then applied to data from one of the LINK - Integrated Farming Systems experimental sites. Data from the Pathhead site in Southern Scotland are used to evaluate the use of invertebrates and nitrate loss as environmental indicators within IAFS. The results suggest that between 1992 and 1995 the biomass of earthworms fell by 28 kg per hectare on the integrated rotation and rose by 31 kg per hectare on the conventional system. This led to environmental costs ranging between £2.24 and £13.44 per hectare for the integrated system and gains of between £2.48 and £14.88 for the conventional system. In terms of nitrate, the integrated system had an estimated loss of £72.21 per hectare in comparison to £149.40 per hectare on the conventional system. Conclusions are drawn about the advantages and disadvantages of this type of analytical framework. Keywords: Farming systems; IAFS; Environmental valuation; Economics; Earthworms; Nitrates; Soil fauna