891 resultados para maximal voluntary contraction
Resumo:
BACKGROUND: Direct colonic electrical stimulation may prove to be a treatment option for specific motility disorders such as chronic constipation. The aim of this study was to provoke colonic contractions using electrical stimulation delivered from a battery-operated device. METHODS: Electrodes were inserted into the caecal seromuscular layer of eight anaesthetized pigs. Contractions were induced by a neurostimulator (Medtronic 3625). Caecal motility was measured simultaneously by video image analysis, manometry and a technique assessing colonic transit. RESULTS: Caecal contractions were generated using 8-10 V amplitude, 1000 micros pulse width, 120 Hz frequency for 10-30 s, with an intensity of 7-15 mA. The maximal contraction strength was observed after 20-25 s. Electrical stimulation was followed by a relaxation phase of 1.5-2 min during which contractions propagated orally and aborally over at least 10 cm. Spontaneous and stimulated caecal motility values were significantly different for both intraluminal pressure (mean(s.d.) 332(124) and 463(187) mmHg respectively; P < 0.001, 42 experiments) and movement of contents (1.6(0.9) and 3.9(2.8) mm; P < 0.001, 40 experiments). CONCLUSION: Electrical stimulation modulated caecal motility, and provoked localized and propagated colonic contractions.
Resumo:
This review summarizes the rationale for personalized exercise training in obesity and diabetes, targeted at the level of maximal lipid oxidation as can be determined by exercise calorimetry. This measurement is reproducible and reflects muscles' ability to oxidize lipids. Targeted training at this level is well tolerated, increases the ability to oxidize lipids during exercise and improves body composition, lipid and inflammatory status, and glycated hemoglobin, thus representing a possible future strategy for exercise prescription in patients suffering from obesity and diabetes.
Resumo:
BACKGROUND: The Advisa MRI system is designed to safely undergo magnetic resonance imaging (MRI). Its influence on image quality is not well known. OBJECTIVE: To evaluate cardiac magnetic resonance (CMR) image quality and to characterize myocardial contraction patterns by using the Advisa MRI system. METHODS: In this international trial with 35 participating centers, an Advisa MRI system was implanted in 263 patients. Of those, 177 were randomized to the MRI group and 150 underwent MRI scans at the 9-12-week visit. Left ventricular (LV) and right ventricular (RV) cine long-axis steady-state free precession MR images were graded for quality. Signal loss along the implantable pulse generator and leads was measured. The tagging CMR data quality was assessed as the percentage of trackable tagging points on complementary spatial modulation of magnetization acquisitions (n=16) and segmental circumferential fiber shortening was quantified. RESULTS: Of all cine long-axis steady-state free precession acquisitions, 95% of LV and 98% of RV acquisitions were of diagnostic quality, with 84% and 93%, respectively, being of good or excellent quality. Tagging points were trackable from systole into early diastole (360-648 ms after the R-wave) in all segments. During RV pacing, tagging demonstrated a dyssynchronous contraction pattern, which was not observed in nonpaced (n = 4) and right atrial-paced (n = 8) patients. CONCLUSIONS: In the Advisa MRI study, high-quality CMR images for the assessment of cardiac anatomy and function were obtained in most patients with an implantable pacing system. In addition, this study demonstrated the feasibility of acquiring tagging data to study the LV function during pacing.
Resumo:
Various pulmonary artery preparations in vitro demonstrate sustained endothelium-dependent contractions upon hypoxia. To determine whether endothelin-1 could mediate this phenomenon, we examined the effect of bosentan, a new antagonist of both the ETA and ETB subtypes of the endothelin receptor. Small (300 pm) pulmonary arteries from rats were mounted on a myograph, precontracted with prostaglandin F2 alpha and exposed to hypoxia (PO2, 10 to 15 mm Hg, measured on-line) for 45 min. Endothelium-intact control rings exhibited a biphasic response, with a transient initial vasoconstriction (phase 1) followed by a second slowly developing sustained contraction (phase 2). Expressed in percent of the maximal response to 80 mmol/L KCl, the amplitudes of phase 1 (peak tension) and 2 (tension after 45 min of hypoxia) averaged 37 +/- 12% and 17 +/- 14%, respectively (n = 11). In endothelium-denuded rings, phase 1 persisted while the amplitude of phase 2 was reduced to 2 +/- 12% (p < 0.05, n = 8), showing the endothelium dependence of this contraction. Neither phase was significantly decreased in rings treated with 10(-5) mmol/L bosentan (38 +/- 15% and 17 +/- 12%, respectively, n = 6). The PO2 threshold for onset of hypoxic contraction was not significantly different among these three groups and averaged 32 +/- 24 mm Hg. In a separate experiment, we assessed the inhibitory effect of 10(-5) mol/L bosentan on the response to 10(-8) mol/L endothelin-I. Rings treated for 45 min with 10(-8) mol/L endothelin-1 alone exhibited a maximal contraction of 75 +/- 27% (n = 6). This was reduced to 4 +/- 17% (p < 0.01, n = 6) in rings treated with both 10(-8) mol/L endothelin-1 and 10(-5) mol/L bosentan. We conclude that complete blockade of all endothelin receptor subtypes has no effect on either endothelium-dependent or -independent hypoxic contractions in this preparation. This suggests that endothelial factors other than endothelin-I mediate the acute hypoxic contractions of small pulmonary arteries in the rat.
Resumo:
BACKGROUND: Lower ambulatory performance with aging may be related to a reduced oxidative capacity within skeletal muscle. This study examined the associations between skeletal muscle mitochondrial capacity and efficiency with walking performance in a group of older adults. METHODS: Thirty-seven older adults (mean age 78 years; 21 men and 16 women) completed an aerobic capacity (VO peak) test and measurement of preferred walking speed over 400 m. Maximal coupled (State 3; St3) mitochondrial respiration was determined by high-resolution respirometry in saponin-permeabilized myofibers obtained from percutanous biopsies of vastus lateralis (n = 22). Maximal phosphorylation capacity (ATP) of vastus lateralis was determined in vivo by P magnetic resonance spectroscopy (n = 30). Quadriceps contractile volume was determined by magnetic resonance imaging. Mitochondrial efficiency (max ATP production/max O consumption) was characterized using ATP per St3 respiration (ATP/St3). RESULTS: In vitro St3 respiration was significantly correlated with in vivo ATP (r = .47, p = .004). Total oxidative capacity of the quadriceps (St3*quadriceps contractile volume) was a determinant of VO peak (r = .33, p = .006). ATP (r = .158, p = .03) and VO peak (r = .475, p < .0001) were correlated with preferred walking speed. Inclusion of both ATP/St3 and VO peak in a multiple linear regression model improved the prediction of preferred walking speed (r = .647, p < .0001), suggesting that mitochondrial efficiency is an important determinant for preferred walking speed. CONCLUSIONS: Lower mitochondrial capacity and efficiency were both associated with slower walking speed within a group of older participants with a wide range of function. In addition to aerobic capacity, lower mitochondrial capacity and efficiency likely play roles in slowing gait speed with age.
Resumo:
In this note we introduce the Lorenz stable set and provide an axiomatic characterization in terms of constrained egalitarianism and projection consistency. On the domain of all coalitional games, we find that this solution connects the weak constrained egalitarian solution (Dutta and Ray, 1989) with their strong counterpart (Dutta and Ray, 1991)
Resumo:
ABSTRACT: BACKGROUND: An increase in new HIV cases among men who have sex with men (MSM) has been reported in Switzerland since 2001. A rapid result HIV testing for MSM through voluntary counselling and testing (VCT) facility ("Checkpoint") was opened in Geneva in 2005. This gay-friendly facility, the first to open in Switzerland, provides testing for sexually transmitted infections (STI) and rapid result HIV testing and counselling. Our objective was to analyze Checkpoint's activity over its first five years of activity and its ability to attract at-risk MSM. METHODS: We used routine data collected anonymously about the facility activity (number of clients, number of tests, and test results) and about the characteristics of the clientele (sociodemographic data, sexual risk behaviour, and reasons for testing) from 2005 to 2009. RESULTS: The yearly number of HIV tests performed increased from 249 in 2005 to 561 in 2009. The annual proportion of positive tests among tests performed varied between 2% and 3%. Among MSM clients, the median annual number of anal intercourse (AI) partners was three. Roughly 30% of all MSM clients had at least one unprotected anal intercourse (UAI) experience in the previous 12 months with a partner of different/unknown HIV status.The main reason for testing in 2007, 2008, and 2009 was "sexual risk exposure" (~40%), followed by "routine" testing (~30%) and "condom stopping in the beginning of a new steady relationship" (~10%). Clients who came to the facility after a sexual risk exposure, compared to clients who came for "routine testing" or "condom stopping" reasons, had the highest number of AI partners in the previous 12 months, were more likely to have had UAI with a partner of different/unknown HIV status in the previous 12 months (respectively 57.3%, 12.5%, 23.5%), more likely to have had an STI diagnosed in the past (41.6%, 32.2%, 22.9%), and more likely to report recent feelings of sadness or depression (42.6%; 32.8%, 18.5%). CONCLUSION: Many of Checkpoint's clients reported elevated sexual risk exposure and risk factors, and the annual proportion of new HIV cases in the facility is stable. This VCT facility attracts the intended population and appears to be a useful tool contributing to the fight against the HIV epidemic among MSM in Switzerland.
Resumo:
Contexte : L'insuffisance cardiaque touche environ 150 personnes sur 100'000 habitants en Suisse, avec une¦prévalence évaluée à 1.45 %, et cause 42.3 décès par 100'000 habitants. Globalement, la prévalence de¦l'insuffisance cardiaque augmente, d'une part à cause du vieillissement de la population, d'autre part par¦l'amélioration de la prise en charge de pathologies cardiaques. La transplantation reste actuellement le gold¦standard pour l'insuffisance cardiaque réfractaire au traitement pharmacologique, mais les organes sont¦rares. Une alternative a donc été développée, celle des systèmes d'assistance ventriculaire (ventricular assist¦device, VAD). Les appareils existants actuellement sur le marché fonctionnent en déviant le sang du¦ventricule vers un système de projection à flux pulsatile ou continu placé dans la cage thoracique, avant de le¦renvoyer vers l'artère. Ils comportent certains défauts, en particulier la nécessité de léser le coeur pour les¦implanter et les risques hémorragique et thrombo-embolique importants. Pour remédier à ces défauts, des¦VAD externes sont en cours de développement. Fixés autour du coeur, ils permettent de l'assister dans la¦contraction, sans contact direct avec le sang ni lésion du coeur. Dans cette étude, nous avons créé deux¦prototypes de VAD externes basés sur la technique du muscle artificiel. Ils sont faits de fils de Nitinol, un¦alliage à mémoire de forme qui raccourcit lorsqu'il est chauffé. Placés autour du coeur, ils lui impriment un¦mouvement de contraction, tel un muscle artificiel.¦Méthode : deux VAD externes ont été créés en utilisant du Nitinol. Les fibres de Nitinol du VAD N°1¦passent à travers des charnières qui augmentent son pouvoir de contraction. Celles du VAD N°2 sont¦orientées dans un maillage de fibres de Kevlar de manière à reproduire la direction des fibres musculaires du¦ventricule humain. Ils ont été testés sur un banc d'essai avec un coeur en silicone. Nous avons mesuré la¦fraction d'éjection, le débit et la pression générée, à différentes valeurs de précharge et post-charge. Les¦VAD étaient alimentés par une génératrice ou par une unité de contrôle, qui permettait de fournir l'énergie¦précisément dans chaque fil de Nitinol et d'imposer une certaine fréquence cardiaque.¦Résultats : Tant avec la génératrice que l'unité de contrôle, le ventricule gauche du VAD N°1 fournit une¦fraction d'éjection maximale de 16.09 %. Le débit maximal est de 191.42 ml/min. La génératrice permet au¦VAD N°2 de fournir une fraction d'éjection de 6.18 %, contre 2.48 % avec l'unité de contrôle. Le débit¦maximal est de 27.37 ml/min. La pression générée atteint 75 mmHg pour le VAD N°1 et 6 mmHg pour le¦VAD N°2.¦Discussion/conclusion : Le VAD N°1 est le plus performant, il permet une augmentation significative de la¦fraction d'éjection et pourrait avoir un impact sur la qualité de vie des patients. L'unité de contrôle apporte¦un avantage sur la génératrice pour le VAD N°1, en dirigeant plus précisément l'énergie dans les fils de¦Nitinol et en limitant les pertes. Le VAD N°2, lui, est peu performant et l'unité de contrôle n'améliore pas¦ses performances. Cela est probablement dû à sa configuration initiale, la taille du VAD n'étant pas adaptée¦au coeur en silicone. Cette étude prouve qu'il est possible d'assister un coeur depuis l'extérieur, sans l'altérer,¦et que la position des fibres de Nitinol a plus d'importance que leur nombre.
Resumo:
In this study, we evaluated the repeatability of pupil responses to colored light stimuli in healthy subjects using a prototype chromatic pupillometer. One eye of 10 healthy subjects was tested twice in the same day using monochromatic light exposure at two selected wavelengths (660 and 470 nm, intensity 300 cd/m(2)) presented continuously for 20 s. Pupil responses were recorded in real-time before, during, and after light exposure. Maximal contraction amplitude and sustained contraction amplitude were calculated. In addition, we quantified the summed pupil response during continuous light stimulation as the total area between a reference line representing baseline pupil size and the line representing actual pupil size over 20 s (area under the curve). There was no significant difference in the repeated measure compared to the first test for any of the pupil response parameters. In conclusion, we have developed a novel prototype of color pupillometer which demonstrates good repeatability in evoking and recording the pupillary response to a bright blue and red light stimulus.
Resumo:
Training and competition in major track-and-field events, and for many team or racquet sports, often require the completion of maximal sprints in hot (>30 °C) ambient conditions. Enhanced short-term (<30 s) power output or single-sprint performance, resulting from transient heat exposure (muscle temperature rise), can be attributed to improved muscle contractility. Under heat stress, elevations in skin/core temperatures are associated with increased cardiovascular and metabolic loads in addition to decreasing voluntary muscle activation; there is also compelling evidence to suggest that large performance decrements occur when repeated-sprint exercise (consisting of brief recovery periods between sprints, usually <60 s) is performed in hot compared with cool conditions. Conversely, poorer intermittent-sprint performance (recovery periods long enough to allow near complete recovery, usually 60-300 s) in hotter conditions is solely observed when exercise induces marked hyperthermia (core temperature >39 °C). Here we also discuss strategies (heat acclimatization, precooling, hydration strategies) employed by "sprint" athletes to mitigate the negative influence of higher environmental temperatures.