973 resultados para low-dimensional system


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The estimation of the average travel distance in a low-level picker-to-part order picking system can be done by analytical methods in most cases. Often a uniform distribution of the access frequency over all bin locations is assumed in the storage system. This only applies if the bin location assignment is done randomly. If the access frequency of the articles is considered in the bin location assignment to reduce the average total travel distance of the picker, the access frequency over the bin locations of one aisle can be approximated by an exponential density function or any similar density function. All known calculation methods assume that the average number of orderlines per order is greater than the number of aisles of the storage system. In case of small orders this assumption is often invalid. This paper shows a new approach for calculating the average total travel distance taking into account that the average number of orderlines per order is lower than the total number of aisles in the storage system and the access frequency over the bin locations of an aisle can be approximated by any density function.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The use of lashing means, for example load securing straps or nets, is often time-consuming, especially for courier, express and parcel-services (CEP) using a lot stops. The following article describes the development of an automated load securing system with a three-dimensional-preformed net. Mainly two components interact in this system. On the one hand, an anti-skid system is integrated, which uses the advantages of a low-friction surface for loading and the anti-slip properties of an adhesive coating for the transport. On the other hand, a flexibly adaptive net consisting of high-performance synthetic fibers and integrated shorteners lash different sized transport units. Especially, the automatic lashing should increase the acceptance of the drivers for the new load securing system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES This study prospectively evaluated the role of a novel 3-dimensional, noninvasive, beat-by-beat mapping system, Electrocardiographic Mapping (ECM), in facilitating the diagnosis of atrial tachycardias (AT). BACKGROUND Conventional 12-lead electrocardiogram, a widely used noninvasive tool in clinical arrhythmia practice, has diagnostic limitations. METHODS Various AT (de novo and post-atrial fibrillation ablation) were mapped using ECM followed by standard-of-care electrophysiological mapping and ablation in 52 patients. The ECM consisted of recording body surface electrograms from a 252-electrode-vest placed on the torso combined with computed tomography-scan-based biatrial anatomy (CardioInsight Inc., Cleveland, Ohio). We evaluated the feasibility of this system in defining the mechanism of AT-macro-re-entrant (perimitral, cavotricuspid isthmus-dependent, and roof-dependent circuits) versus centrifugal (focal-source) activation-and the location of arrhythmia in centrifugal AT. The accuracy of the noninvasive diagnosis and detection of ablation targets was evaluated vis-à-vis subsequent invasive mapping and successful ablation. RESULTS Comparison between ECM and electrophysiological diagnosis could be accomplished in 48 patients (48 AT) but was not possible in 4 patients where the AT mechanism changed to another AT (n = 1), atrial fibrillation (n = 1), or sinus rhythm (n = 2) during the electrophysiological procedure. ECM correctly diagnosed AT mechanisms in 44 of 48 (92%) AT: macro-re-entry in 23 of 27; and focal-onset with centrifugal activation in 21 of 21. The region of interest for focal AT perfectly matched in 21 of 21 (100%) AT. The 2:1 ventricular conduction and low-amplitude P waves challenged the diagnosis of 4 of 27 macro-re-entrant (perimitral) AT that can be overcome by injecting atrioventricular node blockers and signal averaging, respectively. CONCLUSIONS This prospective multicenter series shows a high success rate of ECM in accurately diagnosing the mechanism of AT and the location of focal arrhythmia. Intraprocedural use of the system and its application to atrial fibrillation mapping is under way.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A float-stopper mechanism was designed to drain fish holding tanks directly from the bottom. Unlike traditional, top-drawn standpipe systems, it allows continuous flushing of settled solid waste. It also prevents the accumulation of these wastes between the two standpipes that are used in bottom-drawn, double-walled standpipe systems. When suspended solids are forced upward between the outer and inner standpipes of such systems, a minimum velocity must be maintained to prevent sediment accumulation. This minimum velocity determines the minimum flow rate through the tank. The system described in this report flushes well over a wide range of flow rates.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Refractory ascites (RA) affects 10% of patients with advanced cirrhosis and ascites. Usual therapy includes large volume paracentesis, and in selected patients, a transjugular portosystemic shunt (TIPS). These therapies may be associated with increased morbidity: paracentesis may induce circulatory dysfunction and impair quality of life and TIPS may induce encephalopathy and is associated with increased mortality in patients with severe liver dysfunction. We present the results of a multicenter, non-randomized trial to assess the safety and efficacy of a new automated pump system for treatment of RA. METHODS: Forty patients at 9 centers (February 2010-June 2011) received an implanted pump for the automated removal of ascites from the peritoneal cavity into the bladder, from where it was eliminated through normal urination. Patients were followed-up for 6months. The primary study outcome was safety. Secondary outcomes included recurrence of tense ascites and pump performance. RESULTS: Surgical complications occurred early in the study and became less frequent. The pump system removed 90% of the ascites and significantly reduced the median number of large volume paracentesis per month [3.4 (range 1-6) vs. 0.2 (range 0-4); p <0.01]. Cirrhosis-related adverse events decreased along follow-up. CONCLUSIONS: The automated pump seems an efficacious tool to move out ascites from the peritoneal cavity to the bladder. Its safety is still moderate, but a broad use in different countries will improve the surgical technique as well as the medical surveillance. A prospective randomized clinical trial vs. large volume paracentesis is underway to confirm these preliminary results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

For a three-dimensional vertically-oriented fault zone, we consider the coupled effects of fluid flow, heat transfer and reactive mass transport, to investigate the patterns of fluid flow, temperature distribution, mineral alteration and chemically induced porosity changes. We show, analytically and numerically, that finger-like convection patterns can arise in a vertically-oriented fault zone. The onset and patterns of convective fluid flow are controlled by the Rayleigh number which is a function of the thermal properties of the fluid and the rock, the vertical temperature gradient, and the height and the permeability of the fault zone. Vigorous fluid flow causes low temperature gradients over a large region of the fault zone. In such a case, flow across lithological interfaces becomes the most important mechanism for the formation of sharp chemical reaction fronts. The degree of rock buffering, the extent and intensity of alteration, the alteration mineralogy and in some cases the formation of ore deposits are controlled by the magnitude of the flow velocity across these compositional interfaces in the rock. This indicates that alteration patterns along compositional boundaries in the rock may provide some insights into the convection pattern. The advective mass and heat exchanges between the fault zone and the wallrock depend on the permeability contrast between the fault zone and the wallrock. A high permeability contrast promotes focussed convective flow within the fault zone and diffusive exchange of heat and chemical reactants between the fault zone and the wallrock. However, a more gradual permeability change may lead to a regional-scale convective flow system where the flow pattern in the fault affects large-scale fluid flow, mass transport and chemical alteration in the wallrocks

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Progress toward elucidating the 3D structures of eukaryotic membrane proteins has been hampered by the lack of appropriate expression systems. Recent work using the Xenopus oocyte as a novel expression system for structural analysis demonstrates the capability of providing not only the significant amount of protein yields required for structural work but also the expression of eukaryotic membrane proteins in a more native and functional conformation. There is a long history using the oocyte expression system as an efficient tool for membrane transporter and channel expression in direct functional analysis, but improvements in robotic injection systems and protein yield optimization allow the rapid scalability of expressed proteins to be purified and characterized in physiologically relevant structural states. Traditional overexpression systems (yeast, bacteria, and insect cells) by comparison require chaotropic conditions over several steps for extraction, solubilization, and purification. By contrast, overexpressing within the oocyte system for subsequent negative-staining transmission electron microscopy studies provides a single system that can functionally assess and purify eukaryotic membrane proteins in fewer steps maintaining the physiological properties of the membrane protein.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES Left ventricular assist devices are an important treatment option for patients with heart failure alter the hemodynamics in the heart and great vessels. Because in vivo magnetic resonance studies of patients with ventricular assist devices are not possible, in vitro models represent an important tool to investigate flow alterations caused by these systems. By using an in vitro magnetic resonance-compatible model that mimics physiologic conditions as close as possible, this work investigated the flow characteristics using 4-dimensional flow-sensitive magnetic resonance imaging of a left ventricular assist device with outflow via the right subclavian artery as commonly used in cardiothoracic surgery in the recent past. METHODS An in vitro model was developed consisting of an aorta with its supra-aortic branches connected to a left ventricular assist device simulating the pulsatile flow of the native failing heart. A second left ventricular assist device supplied the aorta with continuous flow via the right subclavian artery. Four-dimensional flow-sensitive magnetic resonance imaging was performed for different flow rates of the left ventricular assist device simulating the native heart and the left ventricular assist device providing the continuous flow. Flow characteristics were qualitatively and quantitatively evaluated in the entire vessel system. RESULTS Flow characteristics inside the aorta and its upper branching vessels revealed that the right subclavian artery and the right carotid artery were solely supported by the continuous-flow left ventricular assist device for all flow rates. The flow rates in the brain-supplying arteries are only marginally affected by different operating conditions. The qualitative analysis revealed only minor effects on the flow characteristics, such as weakly pronounced vortex flow caused by the retrograde flow via the brachiocephalic artery. CONCLUSIONS The results indicate that, despite the massive alterations in natural hemodynamics due to the retrograde flow via the right subclavian and brachiocephalic arteries, there are no drastic consequences on the flow in the brain-feeding arteries and the flow characteristics in the ascending and descending aortas. It may be beneficial to adjust the operating condition of the left ventricular assist device to the residual function of the failing heart.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Submitted in partial fulfillment of the requirements for a Certificate in Orthodontics, Dept. of Orthodontics, University of Connecticut Health Center, 1992

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Internet of Things makes use of a huge disparity of technologies at very different levels that help one to the other to accomplish goals that were previously regarded as unthinkable in terms of ubiquity or scalability. If the Internet of Things is expected to interconnect every day devices or appliances and enable communications between them, a broad range of new services, applications and products can be foreseen. For example, monitoring is a process where sensors have widespread use for measuring environmental parameters (temperature, light, chemical agents, etc.) but obtaining readings at the exact physical point they want to be obtained from, or about the exact wanted parameter can be a clumsy, time-consuming task that is not easily adaptable to new requirements. In order to tackle this challenge, a proposal on a system used to monitor any conceivable environment, which additionally is able to monitor the status of its own components and heal some of the most usual issues of a Wireless Sensor Network, is presented here in detail, covering all the layers that give it shape in terms of devices, communications or services.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Smart and green cities are hot topics in current research because people are becoming more conscious about their impact on the environment and the sustainability of their cities as the population increases. Many researchers are searching for mechanisms that can reduce power consumption and pollution in the city environment. This paper addresses the issue of public lighting and how it can be improved in order to achieve a more energy efficient city. This work is focused on making the process of turning the streetlights on and off more intelligent so that they consume less power and cause less light pollution. The proposed solution is comprised of a radar device and an expert system implemented on a low-cost platform based on a DSP. By analyzing the radar echo in both the frequency and time domains, the system is able to detect and identify objects moving in front of it. This information is used to decide whether or not the streetlight should be turned on. Experimental results show that the proposed system can provide hit rates over 80%, promising a good performance. In addition, the proposed solution could be useful in kind of other applications such as intelligent security and surveillance systems and home automation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Ising problem consists in finding the analytical solution of the partition function of a lattice once the interaction geometry among its elements is specified. No general analytical solution is available for this problem, except for the one-dimensional case. Using site-specific thermodynamics, it is shown that the partition function for ligand binding to a two-dimensional lattice can be obtained from those of one-dimensional lattices with known solution. The complexity of the lattice is reduced recursively by application of a contact transformation that involves a relatively small number of steps. The transformation implemented in a computer code solves the partition function of the lattice by operating on the connectivity matrix of the graph associated with it. This provides a powerful new approach to the Ising problem, and enables a systematic analysis of two-dimensional lattices that model many biologically relevant phenomena. Application of this approach to finite two-dimensional lattices with positive cooperativity indicates that the binding capacity per site diverges as Na (N = number of sites in the lattice) and experiences a phase-transition-like discontinuity in the thermodynamic limit N → ∞. The zeroes of the partition function tend to distribute on a slightly distorted unit circle in complex plane and approach the positive real axis already for a 5×5 square lattice. When the lattice has negative cooperativity, its properties mimic those of a system composed of two classes of independent sites with the apparent population of low-affinity binding sites increasing with the size of the lattice, thereby accounting for a phenomenon encountered in many ligand-receptor interactions.