880 resultados para introductory information system course
Resumo:
Cloud Computing is an enabler for delivering large-scale, distributed enterprise applications with strict requirements in terms of performance. It is often the case that such applications have complex scaling and Service Level Agreement (SLA) management requirements. In this paper we present a simulation approach for validating and comparing SLA-aware scaling policies using the CloudSim simulator, using data from an actual Distributed Enterprise Information System (dEIS). We extend CloudSim with concurrent and multi-tenant task simulation capabilities. We then show how different scaling policies can be used for simulating multiple dEIS applications. We present multiple experiments depicting the impact of VM scaling on both datacenter energy consumption and dEIS performance indicators.
Resumo:
Course materials for e-learning are a special type of information system (IS). Thus, in the development of educational material one may learn from principles, methods, and tools that originated in the Software Engineering (SE) discipline and that are relevant in similar ways in "Instructional Engineering". An important SE principle is mo dularization, which supports properties like reusability and adaptability of code. To foster the adaptability of courseware we present a concept in which learning material is organized as a library of modular course objects. A certain lecturer may customize the courseware according to his specific course requirements. He must consider logical dependencies of and relationship integrity between selected course objects. We discuss integrity issues that have to be regarded for the composition of consistent course materials.
Resumo:
Clinical observations made by practitioners and reported using web- and mobile-based technologies may benefit disease surveillance by improving the timeliness of outbreak detection. Equinella is a voluntary electronic reporting and information system established for the early detection of infectious equine diseases in Switzerland. Sentinel veterinary practitioners have been able to report cases of non-notifiable diseases and clinical symptoms to an internet-based platform since November 2013. Telephone interviews were carried out during the first year to understand the motivating and constraining factors affecting voluntary reporting and the use of mobile devices in a sentinel network. We found that non-monetary incentives attract sentinel practitioners; however, insufficient understanding of the reporting system and of its relevance, as well as concerns over the electronic dissemination of health data were identified as potential challenges to sustainable reporting. Many practitioners are not yet aware of the advantages of mobile-based surveillance and may require some time to become accustomed to novel reporting methods. Finally, our study highlights the need for continued information feedback loops within voluntary sentinel networks.
Resumo:
A three-level satellite to ground monitoring scheme for conservation easement monitoring has been implemented in which high-resolution imagery serves as an intermediate step for inspecting high priority sites. A digital vertical aerial camera system was developed to fulfill the need for an economical source of imagery for this intermediate step. A method for attaching the camera system to small aircraft was designed, and the camera system was calibrated and tested. To ensure that the images obtained were of suitable quality for use in Level 2 inspections, rectified imagery was required to provide positional accuracy of 5 meters or less to be comparable to current commercially available high-resolution satellite imagery. Focal length calibration was performed to discover the infinity focal length at two lens settings (24mm and 35mm) with a precision of O.1mm. Known focal length is required for creation of navigation points representing locations to be photographed (waypoints). Photographing an object of known size at distances on a test range allowed estimates of focal lengths of 25.lmm and 35.4mm for the 24mm and 35mm lens settings, respectively. Constants required for distortion removal procedures were obtained using analytical plumb-line calibration procedures for both lens settings, with mild distortion at the 24mm setting and virtually no distortion found at the 35mm setting. The system was designed to operate in a series of stages: mission planning, mission execution, and post-mission processing. During mission planning, waypoints were created using custom tools in geographic information system (GIs) software. During mission execution, the camera is connected to a laptop computer with a global positioning system (GPS) receiver attached. Customized mobile GIs software accepts position information from the GPS receiver, provides information for navigation, and automatically triggers the camera upon reaching the desired location. Post-mission processing (rectification) of imagery for removal of lens distortion effects, correction of imagery for horizontal displacement due to terrain variations (relief displacement), and relating the images to ground coordinates were performed with no more than a second-order polynomial warping function. Accuracy testing was performed to verify the positional accuracy capabilities of the system in an ideal-case scenario as well as a real-world case. Using many welldistributed and highly accurate control points on flat terrain, the rectified images yielded median positional accuracy of 0.3 meters. Imagery captured over commercial forestland with varying terrain in eastern Maine, rectified to digital orthophoto quadrangles, yielded median positional accuracies of 2.3 meters with accuracies of 3.1 meters or better in 75 percent of measurements made. These accuracies were well within performance requirements. The images from the digital camera system are of high quality, displaying significant detail at common flying heights. At common flying heights the ground resolution of the camera system ranges between 0.07 meters and 0.67 meters per pixel, satisfying the requirement that imagery be of comparable resolution to current highresolution satellite imagery. Due to the high resolution of the imagery, the positional accuracy attainable, and the convenience with which it is operated, the digital aerial camera system developed is a potentially cost-effective solution for use in the intermediate step of a satellite to ground conservation easement monitoring scheme.
Resumo:
Introduction. Lake Houston serves as a reservoir for both recreational and drinking water for residents of Houston, Texas, and the metropolitan area. The Texas Commission on Environmental Quality (TCEQ) expressed concerns about the water quality and increasing amounts of pathogenic bacteria in Lake Houston (3). The objective of this investigation is to evaluate water quality for the presence of bacteria, nitrates, nitrites, carbon, phosphorus, dissolved oxygen, pH, turbidity, suspended solids, dissolved solids, and chlorine in Cypress Creek. The aims of this project are to analyze samples of water from Cypress Creek and to render a quantitative and graphical representation of the results. The collected information will allow for a better understanding of the aqueous environment in Cypress Creek.^ Methods. Water samples were collected in August 2009 and analyzed in the field and at UTSPH laboratory by spectrophotometry and other methods. Mapping software was utilized to develop novel maps of the sample sites using coordinates attained with the Global Positioning System (GPS). Sample sites and concentrations were mapped using Geographic Information System (GIS) software and correlated with permitted outfalls and other land use characteristic.^ Results. All areas sampled were positive for the presence of total coliform and Escherichia coli (E. coli). The presences of other water contaminants varied at each location in Cypress Creek but were under the maximum allowable limits designated by the Texas Commission on Environmental Quality. However, dissolved oxygen concentrations were elevated above the TCEQ limit of 5.0 mg/L at majority of the sites. One site had near-limit concentration of nitrates at 9.8 mg/L. Land use above this site included farm land, agricultural land, golf course, parks, residential neighborhoods, and nine permitted TCEQ effluent discharge sites within 0.5 miles upstream.^ Significance. Lake Houston and its tributary, Cypress Creek, are used as recreational waters where individuals may become exposed to microbial contamination. Lake Houston also is the source of drinking water for much of Houston/Harris and Galveston Counties. This research identified the presence of microbial contaminates in Cypress Creek above TCEQ regulatory requirements. Other water quality variables measured were in line with TCEQ regulations except for near-limit for nitrate at sample site #10, at Jarvis and Timberlake in Cypress Texas.^
Resumo:
Invasive pneumococcal disease (IPD) causes significant health burden in the US, is responsible for the majority of bacterial meningitis, and causes more deaths than any other vaccine preventable bacterial disease in the US. The estimated National IPD rate is 14.3 cases per 100,000 population with a case-fatality rate of 1.5 cases per 100,000 population. Although cases of IPD are routinely reported to the local health department in Harris County Texas, the incidence (IR) and case-fatality (CFR) rates have not been reported. Additionally, it is important to know which serotypes of S. pneumoniae are circulating in Harris County Texas and to determine if ‘replacement disease’ is occurring. ^ This study reported incidence and case-fatality rates from 2003 to 2009, and described the trends in IPD, including the IPD serotypes circulating in Harris County Texas during the study period, particularly in 2008 and 2010. Annual incidence rates were calculated and reported for 2003 to 2009, using complete surveillance-year data. ^ Geographic information system (GIS) software was used to create a series of maps of the data reported during the study period. Cluster and outlier analysis and hot spot analysis were conducted using both case counts by census tract and disease rate by census tract. ^ IPD age- and race-adjusted IR for Harris County Texas and their 95% confidence intervals (CIs) were 1.40 (95% CI 1.0, 1.8), 1.71 (95% CI 1.24, 2.17), 3.13 (95% CI 2.48, 3.78), 3.08 (95% CI 2.43, 3.74), 5.61 (95% CI 4.79, 6.43), 8.11 (95% CI 7.11, 9.1), and 7.65 (95% CI 6.69, 8.61) for the years 2003 to 2009, respectively (rates were age- and race-adjusted to each year's midyear US population estimates). A Poisson regression model demonstrated a statistically significant increasing trend of about 32 percent per year in the IPD rates over the course of the study period. IPD age- and race-adjusted case-fatality rates (CFR) for Harris County Texas were also calculated and reported. A Poisson regression model demonstrated a statistically significant increasing trend of about 26 percent per year in the IPD case-fatality rates from 2003 through 2009. A logistic regression model associated the risk of dying from IPD to alcohol abuse (OR 4.69, 95% CI 2.57, 8.56) and to meningitis (OR 2.42, 95% CI 1.46, 4.03). ^ The prevalence of non-vaccine serotypes (NVT) among IPD cases with serotyped isolates was 98.2 percent. In 2008, the year with the sample more geographically representative of all areas of Harris County Texas, the prevalence was 96 percent. Given these findings, it is reasonable to conclude that ‘replacement disease’ is occurring in Harris County Texas, meaning that, the majority of IPD is caused by serotypes not included in the PCV7 vaccine. Also in conclusion, IPD rates increased during the study period in Harris County Texas.^