956 resultados para first-order actions
Resumo:
We derive the chaotic expansion of the product of nth- and first-order multiple stochastic integrals with respect to certain normal martingales. This is done by application of the classical and quantum product formulae for multiple stochastic integrals. Our approach extends existing results on chaotic calculus for normal martingales and exhibits properties, relative to multiple stochastic integrals, polynomials and Wick products, that characterize the Wiener and Poisson processes.
Resumo:
In the first part of the study, nine estimators of the first-order autoregressive parameter are reviewed and a new estimator is proposed. The relationships and discrepancies between the estimators are discussed in order to achieve a clear differentiation. In the second part of the study, the precision in the estimation of autocorrelation is studied. The performance of the ten lag-one autocorrelation estimators is compared in terms of Mean Square Error (combining bias and variance) using data series generated by Monte Carlo simulation. The results show that there is not a single optimal estimator for all conditions, suggesting that the estimator ought to be chosen according to sample size and to the information available of the possible direction of the serial dependence. Additionally, the probability of labelling an actually existing autocorrelation as statistically significant is explored using Monte Carlo sampling. The power estimates obtained are quite similar among the tests associated with the different estimators. These estimates evidence the small probability of detecting autocorrelation in series with less than 20 measurement times.
Resumo:
The RuskSkinner formalism was developed in order to give a geometrical unified formalism for describing mechanical systems. It incorporates all the characteristics of Lagrangian and Hamiltonian descriptions of these systems (including dynamical equations and solutions, constraints, Legendre map, evolution operators, equivalence, etc.). In this work we extend this unified framework to first-order classical field theories, and show how this description comprises the main features of the Lagrangian and Hamiltonian formalisms, both for the regular and singular cases. This formulation is a first step toward further applications in optimal control theory for partial differential equations. 2004 American Institute of Physics.
Resumo:
Objective: Bone cements and substitutes are commonly used in surgery to deliver antibiotics locally. The objective of this study was to assess the systemic absorption and disposition of vancomycin in patients treated with active calcium sulfate bone filler and to predict systemic concentrations under various conditions. Method: 277 blood samples were taken from 42 patients receiving vancomycin in bone cement during surgery. Blood samples were collected from 3h to 10 days after implantation. Vancomycin was measured by immunoenzymatic assay. Population pharmacokinetic (PK) analysis was performed using NONMEM to assess average estimates and variability of PK parameters. Based on the final model, simulations with various doses and renal function levels were performed. Results: The patients were 64 ± 20 years old, their body weight was 81 ± 22 kg and Cockcroft-Gault creatinine clearance (CLcr) 98 ± 55 mL/min. Vancomycin doses ranged from 200 mg to 6000 mg and implantation sites were hip (n=16), tibia (10) or others (16). Concentration profiles remained low and consistent with absorption rate-limited first-order release, while showing prominent variability. Mean clearance (CL) was 3.87 L/h (CV 35%), absorption rate constant (ka) 0.004 h-1 (66%) and volume of distribution (V) 9.5 L. Simulations with up to 8000 mg vancomycin implant showed systemic concentrations exceeding 20 mg/L for 3.5 days in 43% of the patients with CLcr 15 mL/min, whereas 7% of the patients with normal renal function had a concentration above 20 mg/L for 1.1 days. Subtherapeutic concentrations (0.4-4 mg/L) were predicted during a median of 22 days in patients with normal renal function and 4000 mg vancomycin implant, with limited influence of dose or renal function. Conclusion: Vancomycin-laden calcium sulfate implant does not raise toxicity concern. Selection of resistant bacteria, such as Enterococcus and Staphylococcus species, might however be a concern, as simulations show persistent subtherapeutic systemic concentrations during 3 to 4 weeks in these patients.
Resumo:
BACKGROUND: The aim of this study was to evaluate the efficacy of sustained release of vancomycin and teicoplanin from a resorbable gelatin glycerol sponge, in order to establish a new delivery system for local anti-infective therapy. MATERIALS AND METHODS: 60 plasticized glycerol gelatin sponges containing either 10 or 20% gelatin (w/v) were incubated in vancomycin or teicoplanin solution at 20 degrees C for either 1 or 24 h. In vitro release properties of the sponges were investigated over a period of 1 week by determining the levels of vancomycin and teicoplanin eluted in plasma using fluorescent polarization immunoassay. The rate constant and the half-life for the antibiotic release of each group were calculated by linear regression assuming first order kinetics. RESULTS: Presoaking for 24 h was associated with a significant increase in the total antibiotic release in all groups opposed to 1 h of incubation, except for the 10% sponges presoaked in teicoplanin. Doubling the gelatin content of the sponges from 10 to 20% significantly increased the total release of antibiotic load only in teicoplanin-containing sponges after 24 h incubation. In all corresponding groups investigated, release of vancomycin was more prolonged compared to teicoplanin, which allowed a gradual release beyond 5 days. The half-life (h +/- SEM) of both types of vancomycin-containing sponges was significantly prolonged by 24 h incubation in comparison to 1 h incubation (29.1 +/- 5.9 vs 5.9 +/- 1.0; p < 0.001, 30.0 +/- 2.1 vs 11.1 +/- 1.9; p < 0.001). However, neither doubling the gelatin content of the sponges nor a prolonged incubation was associated with a significantly prolonged delivery of teicoplanin. CONCLUSION: This study demonstrated a better diffusion-controlled release of vancomycin-impregnated glycerol gelatin sponges compared to those pretreated with teicoplanin. The plasticized glycerol gelatin sponge may be a promising carrier for the application of vancomycin to infected wounds for local anti-infective therapy.
Resumo:
AIM: Total imatinib concentrations are currently measured for the therapeutic drug monitoring of imatinib, whereas only free drug equilibrates with cells for pharmacological action. Due to technical and cost limitations, routine measurement of free concentrations is generally not performed. In this study, free and total imatinib concentrations were measured to establish a model allowing the confident prediction of imatinib free concentrations based on total concentrations and plasma proteins measurements. METHODS: One hundred and fifty total and free plasma concentrations of imatinib were measured in 49 patients with gastrointestinal stromal tumours. A population pharmacokinetic model was built up to characterize mean total and free concentrations with inter-patient and intrapatient variability, while taking into account α1 -acid glycoprotein (AGP) and human serum albumin (HSA) concentrations, in addition to other demographic and environmental covariates. RESULTS: A one compartment model with first order absorption was used to characterize total and free imatinib concentrations. Only AGP influenced imatinib total clearance. Imatinib free concentrations were best predicted using a non-linear binding model to AGP, with a dissociation constant Kd of 319 ng ml(-1) , assuming a 1:1 molar binding ratio. The addition of HSA in the equation did not improve the prediction of imatinib unbound concentrations. CONCLUSION: Although free concentration monitoring is probably more appropriate than total concentrations, it requires an additional ultrafiltration step and sensitive analytical technology, not always available in clinical laboratories. The model proposed might represent a convenient approach to estimate imatinib free concentrations. However, therapeutic ranges for free imatinib concentrations remain to be established before it enters into routine practice.
Resumo:
A Hamiltonian formalism is set up for nonlocal Lagrangian systems. The method is based on obtaining an equivalent singular first order Lagrangian, which is processed according to the standard Legendre transformation and then, the resulting Hamiltonian formalism is pulled back onto the phase space defined by the corresponding constraints. Finally, the standard results for local Lagrangians of any order are obtained as a particular case.
Resumo:
Surface geological mapping, laboratory measurements of rock properties, and seismic reflection data are integrated through three-dimensional seismic modeling to determine the likely cause of upper crustal reflections and to elucidate the deep structure of the Penninic Alps in eastern Switzerland. Results indicate that the principal upper crustal reflections recorded on the south end of Swiss seismic line NFP20-EAST can be explained by the subsurface geometry of stacked basement nappes. In addition, modeling results provide improvements to structural maps based solely on surface trends and suggest the presence of previously unrecognized rock units in the subsurface. Construction of the initial model is based upon extrapolation of plunging surface. structures; velocities and densities are established by laboratory measurements of corresponding rock units. Iterative modification produces a best fit model that refines the definition of the subsurface geometry of major structures. We conclude that most reflections from the upper 20 km can be ascribed to the presence of sedimentary cover rocks (especially carbonates) and ophiolites juxtaposed against crystalline basement nappes. Thus, in this area, reflections appear to be principally due to first-order lithologic contrasts. This study also demonstrates not only the importance of three-dimensional effects (sideswipe) in interpreting seismic data, but also that these effects can be considered quantitatively through three-dimensional modeling.
Resumo:
INTRODUCTION: Osteoset(®) T is a calcium sulphate void filler containing 4% tobramycin sulphate, used to treat bone and soft tissue infections. Despite systemic exposure to the antibiotic, there are no pharmacokinetic studies in humans published so far. Based on the observations made in our patients, a model predicting tobramycin serum levels and evaluating their toxicity potential is presented. METHODS: Following implantation of Osteoset(®) T, tobramycin serum concentrations were monitored systematically. A pharmacokinetic analysis was performed using a non-linear mixed effects model based on a one compartment model with first-degree absorption. RESULTS: Data from 12 patients treated between October 2006 and March 2008 were analysed. Concentration profiles were consistent with the first-order slow release and single-compartment kinetics, whilst showing important variability. Predicted tobramycin serum concentrations depended clearly on both implanted drug amount and renal function. DISCUSSION AND CONCLUSION: Despite the popularity of aminoglycosides for local antibiotic therapy, pharmacokinetic data for this indication are scarce, and not available for calcium sulphate as carrier material. Systemic exposure to tobramycin after implantation of Osteoset(®) T appears reassuring regarding toxicity potential, except in case of markedly impaired renal function. We recommend in adapting the dosage to the estimated creatinine clearance rather than solely to the patient's weight.
Resumo:
The disintegration of recovered paper is the first operation in the preparation of recycled pulp. It is known that the defibering process follows a first order kinetics from which it is possible to obtain the disintegration kinetic constant (KD) by means of different ways. The disintegration constant can be obtained from the Somerville index results (%lsv and from the dissipated energy per volume unit (Ss). The %slv is related to the quantity of non-defibrated paper, as a measure of the non-disintegrated fiber residual (percentage of flakes), which is expressed in disintegration time units. In this work, disintegration kinetics from recycled coated paper has been evaluated, working at 20 revise rotor speed and for different fiber consistency (6, 8, 10, 12 and 14%). The results showed that the values of experimental disintegration kinetic constant, Ko, through the analysis of Somerville index, as function of time. Increased, the disintegration time was drastically reduced. The calculation of the disintegration kinetic constant (modelled Ko), extracted from the Rayleigh’s dissipation function, showed a good correlation with the experimental values using the evolution of the Somerville index or with the dissipated energy
Resumo:
The disintegration of recovered paper is the first operation in the preparation of recycled pulp. It is known that the defibering process follows a first order kinetics from which it is possible to obtain the disintegration kinetic constant (KD) by means of different ways. The disintegration constant can be obtained from the Somerville index results (%lsv and from the dissipated energy per volume unit (Ss). The %slv is related to the quantity of non-defibrated paper, as a measure of the non-disintegrated fiber residual (percentage of flakes), which is expressed in disintegration time units. In this work, disintegration kinetics from recycled coated paper has been evaluated, working at 20 revise rotor speed and for different fiber consistency (6, 8, 10, 12 and 14%). The results showed that the values of experimental disintegration kinetic constant, Ko, through the analysis of Somerville index, as function of time. Increased, the disintegration time was drastically reduced. The calculation of the disintegration kinetic constant (modelled Ko), extracted from the Rayleigh’s dissipation function, showed a good correlation with the experimental values using the evolution of the Somerville index or with the dissipated energy
Resumo:
RESUME : Valganciclovir (Valcyte®) is an orally administered ester prodrug of the standard anticytomegalovirus (CMV) drug ganciclovir. This drug enabled an important reduction of the burden of CMV morbidity and mortality in solid organ transplant recipients. Prevention of CMV infection and treatment of CMV disease requires drug administration during many weeks. Oral drug administration is therefore convenient. Valganciclovir has been developed to overcome the poor oral availability of ganciclovir, which limits its concentration exposure after oral administration and thus its efficacy. This prodrug crosses efficiently the intestinal barrier, is then hydrolyzed into ganciclovir, providing exposure similar to intravenous ganciclovir. Valganciclovir is now preferred for the prophylaxis and treatment of CMV infection in solid organ transplant recipients. Nevertheless, adequate dosage adjustment is necessary to optimize its use, avoiding either insufficient or exaggerate exposure related to differences in its pharmacokinetic profile between patients. The main goal of this thesis was to better describe the pharmacokinetic and pharmacodynamic profile of valganciclovir in solid organ transplant recipients, to assess their reproducibility and their predictability, and thus to evaluate the current recommendations for valganciclovir dosage adjustment and the potential contribution of routine therapeutic drug monitoring (TDM) to patients' management. A total of 437 ganciclovir plasma concentration data from 65 transplant patients (41 kidney, 12 lung, 10 heart and 2 liver recipients, 58 under oral valganciclovir prophylaxis, 8 under oral valganciclovir treatment and 2 under intravenous ganciclovir) were measured using a validated chromatographic method (HPLC) developed for this study. The results were analyzed by non-linear mixed effect modeling (NONMEM). A two-compartment model with first-order absorption appropriately described the data. Systemic clearance was markedly influenced by GFR, with further differences between graft types and sex (CL/GFR = 1.7 in kidney, 0.9 in heart and 1.2 in lung and liver recipients) with interpatient variability (CV%) of 26% and interoccasion variability of 12%. Body weight and sex influenced central volume of distribution (V1 = 0.34 l/kg in males and 0.27 l/kg in females) with an interpatient variability of 20%. Residual intrapatient variability was 21 %. No significant drug interaction influenced GCV disposition. VGC prophylactic efficacy and tolerability were good, without detectable dependence on GCV profile. In conclusion, this analysis highlights the importance of thorough adjustment of VGC dosage to renal function and body weight. Considering the good predictability and reproducibility of GCV profile after oral VGC in solid organ transplant recipients, routine TDM does not appear to be clinically indicated. However, GCV plasma measurement may still be helpful in specific clinical situations such as documentation of appropriate exposure in patients with potentially compromised absorption, or lack of response to CMV disease treatment, or under renal replacement therapy. RESUME : Le valganciclovir (Valcyte®) est un promédicament oral du ganciclovir qui est un anti-infectieux de référence contre les infections à cytomegalovirus (CMV). Cet antiviral a permis de réduire les effets délétères de cette infection jusqu'ici responsable d'une importante morbidité et mortalité chez les transplantés d'organe. La prévention et le traitement de l'infection à CMV sont donc nécessaires mais requièrent l'administration d'un agent antiviral sur une longue période. Un médicament administré par voie orale représente donc un avantage évident. Le valganciclovir a été développé dans le but d'améliorer la faible absorption orale du ganciclovir, et donc son efficacité. Cet ester valylique du ganciclovir traverse plus facilement la barrière gastro-intestinale, puis est hydrolysé en ganciclovir dans la circulation sanguine, produisant une exposition comparable à celle d'une perfusion intraveineuse de ganciclovir. De ce fait, le valganciclovir est devenu largement utilisé pour la prophylaxie mais aussi le traitement de l'infection à CMV. Néanmoins une utilisation optimale de ce nouveau médicament nécessite de bonnes connaissances sur son profil pharmacocinétique afin d'établir un schéma de dose adapté pour éviter tant une surexposition qu'une sous-exposition résultant des différences d'élimination entre les patients. Le but de cette thèse a été d'étudier le profil pharmacocinétique et pharmacodynamique du valganciclovir chez les transplantés d'organe ainsi que sa reproductibilité et sa prédictibilité. Il s'agissait d'apprécier de manière critique le schéma actuellement recommandé pour l'adaptation des doses de valganciclovir, mais aussi la contribution éventuelle d'un suivi des concentrations sanguines en routine. Un total de 437 taux sanguins de ganciclovir ont été mesurés, provenant de 65 patients transplantés d'organe (41 rénaux, 12 pulmonaires, 10 cardiaques et 2 hépatiques, 58 sous une prophylaxie orale de valganciclovir, 8 sous un traitement de valganciclovir et 2 sous un traitement intraveineux). Une méthode de chromatographie liquide à haute performance a été développée et validée pour cette étude. Les résultats ont été ensuite analysés par modélisation non linéaire à effets mixtes (NONMEM). Un modèle à deux compartiments avec absorption de premier ordre a permis de décrire les données. La clairance systémique était principalement influencée par le débit de filtration glomérulaire (GFR), avec une différence entre les types de greffe et les sexes (CL/GFR = 1.7 chez les greffés rénaux, 0.9 pour les greffés cardiaques et 1.2 pour le groupe des greffés pulmonaires et hépatiques) avec un variabilité inter-individuelle de 26% (CV%) et une variabilité inter-occasion de 12%. Le poids corporel ainsi que le sexe avaient une influence sur le volume central de distribution (V1 = 0.34 l/kg chez les hommes et 0.27 l/kg chez les femmes) avec une variabilité inter-individuelle de 20%. La variabilité intra-individuelle résiduelle était de 21 %. Aucune interaction médicamenteuse n'a montré d'influence sur le profil du ganciclovir. La prophylaxie avec le valganciclovir s'est révélée efficace et bien tolérée. En conclusion, cette analyse souligne l'importance d'une adaptation de la dose du valganciclovir à la fonction rénale et au poids du patient. Au vu de la bonne reproductibilité et prédictibilité du profil pharmacocinétique du ganciclovir chez les patients transplantés recevant du valganciclovir, un suivi des concentrations sanguines en routine ne semble pas cliniquement indiqué. Néanmoins, la mesure des taux plasmatiques de ganciclovir peut être utile dans certaines situations particulières, comme la vérification d'une exposition appropriée chez des patients susceptibles d'absorption insuffisante, ou ne répondant pas au traitement d'une infection à CMV ou encore sous épuration extra-rénale. RESUME LARGE PUBLIC : Le valganciclovir est un précurseur capable de libérer du ganciclovir, récemment développé pour améliorer la faible absorption orale de ce dernier. Une fois le valganciclovir absorbé, le ganciclovir libéré dans la circulation sanguine devient efficace contre les infections à cytomégalovirus. Ce virus largement répandu est responsable de maladies insidieuses et parfois graves chez les personnes présentant une baisse des défenses immunitaires, comme les greffés d'organe recevant un traitement anti-rejet. Le ganciclovir est administré pendant plusieurs mois consécutifs soit pour prévenir une infection après la transplantation, soit pour traiter une infection déclarée. La facilité d'administration du valganciclovir par voie orale représente un avantage sur une administration du ganciclovir par perfusion, qui nécessite une hospitalisation. Toutefois, la voie orale peut être une source supplémentaire de variabilité chez les patients, avec un impact potentiel sur l'efficacité ou la toxicité du médicament. Le but de cette étude a été - de décrire le devenir de ce médicament dans le corps humain (dont l'étude relève de la discipline de la pharmacocinétique) - de définir les facteurs cliniques pouvant expliquer les différences de concentration sanguine observées entre les patients sous une posologie donnée - d'explorer les relations entre les concentrations du médicament dans le sang et son efficacité ou la survenue d'effets indésirables (dont l'étude relève de la discipline de la pharmacodynamie). Cette étude a nécessité le développement et la validation, d'une méthode d'analyse pour mesurer la concentration sanguine du ganciclovir, puis son application à 437 échantillons provenant de 65 patients transplantés d'organe solide (41 rénaux, 12 pulmonaires, 10 cardiaques et 2 hépatiques) recevant du valganciclovir. Les résultats des mesures effectuées ont été analysés à l'aide d'un outil mathématique afin d'élaborer un modèle du devenir du médicament dans le sang chez chaque patient et à chaque occasion. Cette étude a permis d'évaluer chez des patients recevant le valganciclovir, la vitesse à laquelle l'organisme absorbe, distribue, puis élimine le médicament. La vitesse d'élimination dépendait étroitement de la fonction rénale, du type de greffe et du sexe alors que la distribution dépendait du poids et du sexe du patient. La variabilité non expliquée par ces facteurs cliniques était modérée et vraisemblablement sans conséquence clinique évidente soit sur l'efficacité ou la tolérance, qui se révèlent très satisfaisantes chez les patients de l'étude. Les observations n'ont pas révélé de relation entre les concentrations de médicament et l'efficacité thérapeutique ou la survenue d'effets indésirables, confirmant que les doses relativement faibles utilisées dans notre collectif de patients suffisaient à produire une exposition reproductible à des concentrations adéquates. En conclusion, le profil (et par conséquent l'absorption) du valganciclovir chez les patients transplantés semble bien prédictible après une adaptation de la dose à la fonction rénale et au poids du patient. Un contrôle systématique des concentrations sanguines n'est probablement pas indiqué en routine, mais cette mesure peut présenter un intérêt dans certaines conditions particulières.
Resumo:
The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.
Resumo:
The spatial resolution visualized with hydrological models and the conceptualized images of subsurface hydrological processes often exceed resolution of the data collected with classical instrumentation at the field scale. In recent years it was possible to increasingly diminish the inherent gap to information from point like field data through the application of hydrogeophysical methods at field-scale. With regards to all common geophysical exploration techniques, electric and electromagnetic methods have arguably to greatest sensitivity to hydrologically relevant parameters. Of particular interest in this context are induced polarisation (IP) measurements, which essentially constrain the capacity of a probed subsurface region to store an electrical charge. In the absence of metallic conductors the IP- response is largely driven by current conduction along the grain surfaces. This offers the perspective to link such measurements to the characteristics of the solid-fluid-interface and thus, at least in unconsolidated sediments, should allow for first-order estimates of the permeability structure.¦While the IP-effect is well explored through laboratory experiments and in part verified through field data for clay-rich environments, the applicability of IP-based characterizations to clay-poor aquifers is not clear. For example, polarization mechanisms like membrane polarization are not applicable in the rather wide pore-systems of clay free sands, and the direct transposition of Schwarz' theory relating polarization of spheres to the relaxation mechanism of polarized cells to complex natural sediments yields ambiguous results.¦In order to improve our understanding of the structural origins of IP-signals in such environments as well as their correlation with pertinent hydrological parameters, various laboratory measurements have been conducted. We consider saturated quartz samples with a grain size spectrum varying from fine sand to fine gravel, that is grain diameters between 0,09 and 5,6 mm, as well as corresponding pertinent mixtures which can be regarded as proxies for widespread alluvial deposits. The pore space characteristics are altered by changing (i) the grain size spectra, (ii) the degree of compaction, and (iii) the level of sorting. We then examined how these changes affect the SIP response, the hydraulic conductivity, and the specific surface area of the considered samples, while keeping any electrochemical variability during the measurements as small as possible. The results do not follow simple assumptions on relationships to single parameters such as grain size. It was found that the complexity of natural occurring media is not yet sufficiently represented when modelling IP. At the same time simple correlation to permeability was found to be strong and consistent. Hence, adaptations with the aim of better representing the geo-structure of natural porous media were applied to the simplified model space used in Schwarz' IP-effect-theory. The resulting semi- empiric relationship was found to more accurately predict the IP-effect and its relation to the parameters grain size and permeability. If combined with recent findings about the effect of pore fluid electrochemistry together with advanced complex resistivity tomography, these results will allow us to picture diverse aspects of the subsurface with relative certainty. Within the framework of single measurement campaigns, hydrologiste can than collect data with information about the geo-structure and geo-chemistry of the subsurface. However, additional research efforts will be necessary to further improve the understanding of the physical origins of IP-effect and minimize the potential for false interpretations.¦-¦Dans l'étude des processus et caractéristiques hydrologiques des subsurfaces, la résolution spatiale donnée par les modèles hydrologiques dépasse souvent la résolution des données du terrain récoltées avec des méthodes classiques d'hydrologie. Récemment il est possible de réduire de plus en plus cet divergence spatiale entre modèles numériques et données du terrain par l'utilisation de méthodes géophysiques, notamment celles géoélectriques. Parmi les méthodes électriques, la polarisation provoquée (PP) permet de représenter la capacité des roches poreuses et des sols à stocker une charge électrique. En l'absence des métaux dans le sous-sol, cet effet est largement influencé par des caractéristiques de surface des matériaux. En conséquence les mesures PP offrent une information des interfaces entre solides et fluides dans les matériaux poreux que nous pouvons lier à la perméabilité également dirigée par ces mêmes paramètres. L'effet de la polarisation provoquée à été étudié dans différentes études de laboratoire, ainsi que sur le terrain. A cause d'une faible capacité de polarisation des matériaux sableux, comparé aux argiles, leur caractérisation par l'effet-PP reste difficile a interpréter d'une manière cohérente pour les environnements hétérogènes.¦Pour améliorer les connaissances sur l'importance de la structure du sous-sol sableux envers l'effet PP et des paramètres hydrologiques, nous avons fait des mesures de laboratoire variées. En détail, nous avons considéré des échantillons sableux de quartz avec des distributions de taille de grain entre sables fins et graviers fins, en diamètre cela fait entre 0,09 et 5,6 mm. Les caractéristiques de l'espace poreux sont changées en modifiant (i) la distribution de taille des grains, (ii) le degré de compaction, et (iii) le niveau d'hétérogénéité dans la distribution de taille de grains. En suite nous étudions comment ces changements influencent l'effet-PP, la perméabilité et la surface spécifique des échantillons. Les paramètres électrochimiques sont gardés à un minimum pendant les mesures. Les résultats ne montrent pas de relation simple entre les paramètres pétro-physiques comme par exemples la taille des grains. La complexité des media naturels n'est pas encore suffisamment représenté par les modèles des processus PP. Néanmoins, la simple corrélation entre effet PP et perméabilité est fort et consistant. En conséquence la théorie de Schwarz sur l'effet-PP a été adapté de manière semi-empirique pour mieux pouvoir estimer la relation entre les résultats de l'effet-PP et les paramètres taille de graines et perméabilité. Nos résultats concernant l'influence de la texture des matériaux et celles de l'effet de l'électrochimie des fluides dans les pores, permettront de visualiser des divers aspects du sous-sol. Avec des telles mesures géo-électriques, les hydrologues peuvent collectionner des données contenant des informations sur la structure et la chimie des fluides des sous-sols. Néanmoins, plus de recherches sur les origines physiques de l'effet-PP sont nécessaires afin de minimiser le risque potentiel d'une mauvaise interprétation des données.
Resumo:
We report on the study of nonequilibrium ordering in the reaction-diffusion lattice gas. It is a kinetic model that relaxes towards steady states under the simultaneous competition of a thermally activated creation-annihilation $(reaction$) process at temperature T, and a diffusion process driven by a heat bath at temperature T?T. The phase diagram as one varies T and T, the system dimension d, the relative priori probabilities for the two processes, and their dynamical rates is investigated. We compare mean-field theory, new Monte Carlo data, and known exact results for some limiting cases. In particular, no evidence of Landau critical behavior is found numerically when d=2 for Metropolis rates but Onsager critical points and a variety of first-order phase transitions.