910 resultados para colour cues
Resumo:
Colour stability of resin and silicone is an important factor for longevity of facial prostheses. The aim of this study was to evaluate the colour stability of resins and silicone for facial prostheses. Three brands of acrylic resin and one of facial silicone were evaluated considering pigment incorporation for the colourless materials. Ten samples of each material were fabricated and submitted to measurements of chromatic alteration initially and after 90 and 180 days of weathering natural through visual analysis and spectrophotometry. Data were evaluated by ANOVA and Tukey test (p < 0.05). Statistically significant colour alteration was observed among some materials regardless of the period. The materials did not present a statistical difference between 90 and 180 days except for the pigmented heat-polymerized resin. The colour difference between pigmented Silastic MDX4-4210 and colourless Silastic was statistically significant (p < 0.01) in both periods as well as between pigmented and colourless heat-polymerized resin, and between the resins Rapidaflex and Lentaflex. The visual method demonstrated colour alteration in all materials evaluated during the first 90 days of ageing. All materials exhibited colour alteration due to exposure to environment. © 2012 Informa UK, Ltd.
Resumo:
In this study, we show that the fish Nile tilapia displays an antipredator response to chemical cues present in the blood of conspecifics. This is the first report of alarm response induced by blood-borne chemical cues in fish. There is a body of evidence showing that chemical cues from epidermal 'club' cells elicit an alarm reaction in fish. However, the chemical cues of these 'club' cells are restricted to certain species of fish. Thus, as a parsimonious explanation, we assume that an alarm response to blood cues is a generalized response among animals because it occurs in mammals, birds and protostomian animals. Moreover, our results suggest that researchers must use caution when studying chemically induced alarm reactions because it is difficult to separate club cell cues from traces of blood. © 2013 Barreto et al.
Resumo:
Megalopas de muitas espécies de caranguejos decápodes aceleram seu período de desenvolvimento até a metamorfose (TOM) quando são expostas a estímulos naturais físicos e/ou químicos característicos do habitat parental. No presente estudo, a influência de estímulos naturais sobre as taxas de muda e sobre o PDM foi investigada nas megalopas do caranguejo violinistac. Os efeitos da (i) lama de diferentes habitats (incluindo habitats de um manguezal bem preservado e de um degradado e poluído) e (ii) 'odores' dos adultos conspecíficos (água do mar acondicionada com caranguejos) sobre a indução da metamorfose foram comparados com (iii) água do mar pura e filtrada (controle). 95 a 100% das megalopas realizaram a metamorfose com sucesso para o primeiro estágio de caranguejo juvenil em todos os tratamentos, incluindo o controle. No entanto, o PDM diferiu significativamente entre os tratamentos. Os estímulos encurtaram significativamente o desenvolvimento, enquanto que a muda foi retardada na ausência deles. O fato de que as megalopas responderam aos estímulos indutores da metamorfose oriundos de ambos os habitats bentônicos dos adultos e de habitats onde eles são ausentes, demonstra que o assentamento nesta espécie pode ocorrer em uma grande variedade de habitats dentro do ecossistema de manguezal, incluindo áreas impactadas.
Resumo:
Os testes Colour Assessment and Diagnosis (CAD) e Cambridge Colour Test (CCT) têm sido amplamente utilizados em pesquisas básicas e clínicas, devido à alta sensibilidade e especificidade de seus resultados. Estes testes utilizam diferentes paradigmas de estimulação para estimar os limiares de discriminação de cor. Pouco se sabe sobre a relação de cada paradigma na avaliação da discriminação de cor nesses testes. Sendo assim, este trabalho objetiva comparar os parâmetros de avaliação da discriminação de cor estimados pelos testes CAD e CCT em sujeitos tricromatas e com discromatopsia congênita. Foram avaliados 59 sujeitos tricromatas e 38 sujeitos discromatópsicos (16 protans, 22 deutans) com idade média de 26,32 ± 8,9 anos. Foram testados 66 sujeitos nos testes CAD e CCT, 29 sujeitos no teste CAD e 2 sujeitos no teste CCT. O fenótipo da visão de cores de todos os sujeitos foi determinado através de uma bateria de testes psicofísicos e a estimativa dos limiares de discriminação de cor foi avaliada pelos testes CAD e CCT. Os dados de limiares de discriminação de cor foram ajustados a funções de elipse. Os critérios analisados para cada sujeito foram: a área da elipse, o ângulo de rotação e tamanho dos vetores protan, deutan e tritan. Para cada um dos parâmetros foi realizada: estatística descritiva, análise da dispersão dos parâmetros entre os testes CAD e CCT e dos parâmetros em conjunto, razão entre os parâmetros, correlação dos parâmetros a três modelos matemáticos e análise de concordância. Os parâmetros de área e tamanho dos vetores deutan e tritan do subgrupo tricromata; área e tamanho do vetor tritan do subgrupo protan; e tamanho dos vetores protan e tritan do subgrupo deutan apresentaram equivalência entre os resultados de ambos os testes. Os parâmetros de área, ângulo de rotação e tamanho dos vetores protan e tritan apresentaram concordância de medidas entre os testes CAD e CCT. Fatores como as localizações distintas das coordenadas centrais dos testes CAD e CCT e a disposição espacial dos vetores no espaço de cor da CIE 1976 no teste CCT podem ter influenciado na determinação de limiares de discriminação cromática de ambos os testes. Apesar de utilizarem paradigmas distintos na configuração da estimulação, os testes CAD e CCT são equiparáveis.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The goal of this study was to investigate the effects of manipulation of the characteristics of visual stimulus on postural control in dyslexic children. A total of 18 dyslexic and 18 non-dyslexic children stood upright inside a moving room, as still as possible, and looked at a target at different conditions of distance between the participant and a moving room frontal wall (25-150 cm) and vision (full and central). The first trial was performed without vision (baseline). Then four trials were performed in which the room remained stationary and eight trials with the room moving, lasting 60 s each. Mean sway amplitude, coherence, relative phase, and angular deviation were calculated. The results revealed that dyslexic children swayed with larger magnitude in both stationary and moving conditions. When the room remained stationary, all children showed larger body sway magnitude at 150 cm distance. Dyslexic children showed larger body sway magnitude in central compared to full vision condition. In the moving condition, body sway magnitude was similar between dyslexic and non-dyslexic children but the coupling between visual information and body sway was weaker in dyslexic children. Moreover, in the absence of peripheral visual cues, induced body sway in dyslexic children was temporally delayed regarding visual stimulus. Taken together, these results indicate that poor postural control performance in dyslexic children is related to how sensory information is acquired from the environment and used to produce postural responses. In conditions in which sensory cues are less informative, dyslexic children take longer to process sensory stimuli in order to obtain precise information, which leads to performance deterioration. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The colour stability of acrylic resin denture teeth in beverages was investigated. A spectrophotometer measured the colour (CIE-L*a*b* system) of all specimens after storage in distilled water for 24 h at 37°C (T0). Specimens were then immersed in various beverages. After 15 days (T1) and 30 days (T2), for each material, the mean ∆E values were calculated and compared by two-way ANOVA and Tukey intervals (α=0.05). In the ∆T0T1 period, specimens stored in red wine were significantly discoloured, compared to distilled water (P=0.003). There was no difference between immersion solutions in ∆ET0T2 (P=0.772) and in ∆ET1T2 (P=0.058), and no difference between materials in all immersion periods.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Color vision impairment emerges at early stages of diabetes mellitus type 2 (DM2) and may precede diabetic retinopathy or the appearance of vascular alterations in the retina. The aim of the present study was to compare the evaluation of the color vision with two different tests - the Lanthony desaturated D-15d test (a traditional color arrangement test), and the Cambridge Colour Test (CCT) (a computerized color discrimination test) - in patients diagnosed with DM2 without clinical signs of diabetic retinopathy (DR), and in sex- and age-matched control groups. Both color tests revealed statistically significant differences between the controls and the worst eyes of the DM2 patients. In addition, the degree of color vision impairment diagnosed by both tests correlated with the disease duration. The D-15d outcomes indicated solely tritan losses. In comparison, CCT outcomes revealed diffuse losses in color discrimination: 13.3% for best eyes and 29% for worst eyes. In addition, elevation of tritan thresholds in the DM2 patients, as detected by the Trivector subtest of the CCT, was found to correlate with the level of glycated hemoglobin. Outcomes of both tests confirm that subclinical losses of color vision are present in DM2 patients at an early stage of the disease, prior to signs of retinopathy. Considering the advantages of the CCT test compared to the D-15d test, further studies should attempt to verify and/or improve the efficiency of the CCT test.
Resumo:
The present study aimed at providing conditions for the assessment of color discrimination in children using a modified version of the Cambridge Colour Test (CCT, Cambridge Research Systems Ltd., Rochester, UK). Since the task of indicating the gap of the Landolt C used in that test proved counterintuitive and/or difficult for young children to understand, we changed the target Stimulus to a patch of color approximately the size of the Landolt C gap (about 7 degrees Of Visual angle at 50 cm from the monitor). The modifications were performed for the CCT Trivector test which measures color discrimination for the protan, deutan and tritan confusion lines. Experiment I Sought to evaluate the correspondence between the CCT and the child-friendly adaptation with adult subjects (n = 29) with normal color vision. Results showed good agreement between the two test versions. Experiment 2 tested the child-friendly software with children 2 to 7 years old (n = 25) using operant training techniques for establishing and maintaining the subjects` performance. Color discrimination thresholds were progressively lower as age increased within the age range tested (2 to 30 years old), and the data-including those obtained for children-fell within the range of thresholds previously obtained for adults with the CCT. The protan and deutan thresholds were consistently lower than tritan thresholds, a pattern repeatedly observed in adults tested with the CCT. The results demonstrate that the test is fit for assessment of color discrimination in young children and may be a useful tool for the establishment of color vision thresholds during development.
Resumo:
We assessed chromatic discrimination in multiple sclerosis (MS) patients both with (ON) and without (no ON) a history of optic neuritis using the Cambridge color test (CCT). Our goal was to determine the magnitude and chromatic axes of any color vision losses in both patient groups, and to evaluate age-related changes in chromatic discrimination in both patient groups compared to normals. Using the CCT, we measured chromatic discrimination along the protan, deutan and tritan axes in 35 patients with MS (17 ON eyes) and 74 age matched controls. Color thresholds for both patient groups were significantly higher than controls` along the protan and tritan axes (P < 0.001). In addition, the ON and no-ON groups differed significantly along all three-color axes (p < 0.001). MS patients presented a progressive color discrimination impairment with age (along the deutan and tritan axes) that was almost two times faster than controls, even in the absence of ON. These findings suggest that demyelinating diseases reduce sensitivity to color vision in both red-green and blue-yellow axes, implying impairment in both parvocellular and koniocellular visual pathways. The CCT is a useful tool to help characterize vision losses in MS and the relationship between these losses and degree of optic nerve involvement.