950 resultados para accuracy of estimation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visual inspection with Acetic Acid (VIA) and Visual Inspection with Lugol’s Iodine (VILI) are increasingly recommended in various cervical cancer screening protocols in low-resource settings. Although VIA is more widely used, VILI has been advocated as an easier and more specific screening test. VILI has not been well-validated as a stand-alone screening test, compared to VIA or validated for use in HIV-infected women. We carried out a randomized clinical trial to compare the diagnostic accuracy of VIA and VILI among HIV-infected women. Women attending the Family AIDS Care and Education Services (FACES) clinic in western Kenya were enrolled and randomized to undergo either VIA or VILI with colposcopy. Lesions suspicious for cervical intraepithelial neoplasia 2 or greater (CIN2+) were biopsied. Between October 2011 and June 2012, 654 were randomized to undergo VIA or VILI. The test positivity rates were 26.2% for VIA and 30.6% for VILI (p = 0.22). The rate of detection of CIN2+ was 7.7% in the VIA arm and 11.5% in the VILI arm (p = 0.10). There was no significant difference in the diagnostic performance of VIA and VILI for the detection of CIN2+. Sensitivity and specificity were 84.0% and 78.6%, respectively, for VIA and 84.2% and 76.4% for VILI. The positive and negative predictive values were 24.7% and 98.3% for VIA, and 31.7% and 97.4% for VILI. Among women with CD4+ count < 350, VILI had a significantly decreased specificity (66.2%) compared to VIA in the same group (83.9%, p = 0.02) and compared to VILI performed among women with CD4+ count ≥ 350 (79.7%, p = 0.02). VIA and VILI had similar diagnostic accuracy and rates of CIN2+ detection among HIV-infected women.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Computer-Aided-Design (CAD) and Computer-Aided-Manufacture (CAM) has been developed to fabricate fixed dental restorations accurately, faster and improve cost effectiveness of manufacture when compared to the conventional method. Two main methods exist in dental CAD/CAM technology: the subtractive and additive methods. While fitting accuracy of both methods has been explored, no study yet has compared the fabricated restoration (CAM output) to its CAD in terms of accuracy. The aim of this present study was to compare the output of various dental CAM routes to a sole initial CAD and establish the accuracy of fabrication. The internal fit of the various CAM routes were also investigated. The null hypotheses tested were: 1) no significant differences observed between the CAM output to the CAD and 2) no significant differences observed between the various CAM routes. Methods: An aluminium master model of a standard premolar preparation was scanned with a contact dental scanner (Incise, Renishaw, UK). A single CAD was created on the scanned master model (InciseCAD software, V2.5.0.140, UK). Twenty copings were then fabricated by sending the single CAD to a multitude of CAM routes. The copings were grouped (n=5) as: Laser sintered CoCrMo (LS), 5-axis milled CoCrMo (MCoCrMo), 3-axis milled zirconia (ZAx3) and 4-axis milled zirconia (ZAx4). All copings were micro-CT scanned (Phoenix X-Ray, Nanotom-S, Germany, power: 155kV, current: 60µA, 3600 projections) to produce 3-Dimensional (3D) models. A novel methodology was created to superimpose the micro-CT scans with the CAD (GOM Inspect software, V7.5SR2, Germany) to indicate inaccuracies in manufacturing. The accuracy in terms of coping volume was explored. The distances from the surfaces of the micro-CT 3D models to the surfaces of the CAD model (CAD Deviation) were investigated after creating surface colour deviation maps. Localised digital sections of the deviations (Occlusal, Axial and Cervical) and selected focussed areas were then quantitatively measured using software (GOM Inspect software, Germany). A novel methodology was also explored to digitally align (Rhino software, V5, USA) the micro-CT scans with the master model to investigate internal fit. Fifty digital cross sections of the aligned scans were created. Point-to-point distances were measured at 5 levels at each cross section. The five levels were: Vertical Marginal Fit (VF), Absolute Marginal Fit (AM), Axio-margin Fit (AMF), Axial Fit (AF) and Occlusal Fit (OF). Results: The results of the volume measurement were summarised as: VM-CoCrMo (62.8mm3 ) > VZax3 (59.4mm3 ) > VCAD (57mm3 ) > VZax4 (56.1mm3 ) > VLS (52.5mm3 ) and were all significantly different (p presented as areas with different colour. No significant differences were observed at the internal aspect of the cervical aspect between all groups of copings. Significant differences (p< M-CoCrMo Internal Occlusal, Internal Axial and External Axial 2 ZAx3 > ZAx4 External Occlusal, External Cervical 3 ZAx3 < ZAx4 Internal Occlusal 4 M-CoCrMo > ZAx4 Internal Occlusal and Internal Axial The mean values of AMF and AF were significantly (p M-CoCrMo and CAD > ZAx4. Only VF of M-CoCrMo was comparable with the CAD Internal Fit. All VF and AM values were within the clinically acceptable fit (120µm). Conclusion: The investigated CAM methods reproduced the CAD accurately at the internal cervical aspect of the copings. However, localised deviations at axial and occlusal aspects of the copings may suggest the need for modifications in these areas prior to fitting and veneering with porcelain. The CAM groups evaluated also showed different levels of Internal Fit thus rejecting the null hypotheses. The novel non-destructive methodologies for CAD/CAM accuracy and internal fit testing presented in this thesis may be a useful evaluation tool for similar applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To measure the step-count accuracy of an ankle-worn accelerometer, a thigh-worn accelerometer and one pedometer in older and frail inpatients. Design: Cross-sectional design study. Setting: Research room within a hospital. Participants: Convenience sample of inpatients aged ≥65 years, able to walk 20 metres unassisted, with or without a walking-aid. Intervention: Patients completed a 40-minute programme of predetermined tasks while wearing the three motion sensors simultaneously. Video-recording of the procedure provided the criterion measurement of step-count. Main Outcome Measures: Mean percentage (%) errors were calculated for all tasks, slow versus fast walkers, independent versus walking-aid-users, and over shorter versus longer distances. The Intra-class Correlation was calculated and accuracy was visually displayed by Bland-Altman plots. Results: Thirty-two patients (78.1 ±7.8 years) completed the study. Fifteen were female and 17 used walking-aids. Their median speed was 0.46 m/sec (interquartile range, IQR 0.36-0.66). The ankle-worn accelerometer overestimated steps (median 1% error, IQR -3 to 13). The other motion sensors underestimated steps (40% error (IQR -51 to -35) and 38% (IQR -93 to -27), respectively). The ankle-worn accelerometer proved more accurate over longer distances (3% error, IQR 0 to 9), than shorter distances (10%, IQR -23 to 9). Conclusions: The ankle-worn accelerometer gave the most accurate step-count measurement and was most accurate over longer distances. Neither of the other motion sensors had acceptable margins of error.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previous research on person perception has shown that people form first impressions with remarkable speed and accuracy, but relatively little is known about the speed and accuracy of trustworthiness judgments across cultures. The present research examined these by asking Chinese and Canadians to infer trustworthiness from faces of criminals and non-criminals from different cultural backgrounds across two domains (i.e., financial crime in Study 1 and violent crime in Study 2). Across both studies, we found that when participants were given time and opportunity, Chinese tended to take a longer time than Canadians to make trustworthiness judgments (although this difference did not reach statistical significance in Study 2). In Study 1, we found that perceivers from both cultures were accurate at judging European North Americans (ENA) corporate criminals as less trustworthy than ENA non-criminal executives, although they did not differentiate Asian corporate criminals from Asian non-criminal executives. In Study 2, we found that perceivers from both cultures were accurate at judging both Asian and ENA violent criminals as less trustworthy than Asian and ENA non-criminals. Chinese were also accurate at rating Middle Eastern violent criminals as less trustworthy than Middle Eastern non-criminals, but Canadians did not differentiate them in terms of their trustworthiness ratings. In terms of their crime likelihood ratings, however, both Chinese and Canadians accurately rated all the criminals as more likely to commit violent crimes than the non-criminals, regardless of the targets’ ethnicities. Finally, we discussed some of the practical implications of our findings on detection of deception, as well as how providing a context for trustworthiness judgments might have played an important role in people’s judgmental accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pop-up archival tags (PAT) provide summary and high-resolution time series data at predefined temporal intervals. The limited battery capabilities of PATs often restrict the transmission success and thus temporal coverage of both data products. While summary data are usually less affected by this problem, as a result of its lower size, it might be less informative. We here investigate the accuracy and feasibility of using temperature at depth summary data provided by PATs to describe encountered oceanographic conditions. Interpolated temperature at depth summary data was found to provide accurate estimates of three major thermal water column structure indicators: thermocline depth, stratification and ocean heat content. Such indicators are useful for the interpretation of the tagged animal's horizontal and vertical behaviour. The accuracy of these indicators was found to be particularly sensitive to the number of data points available in the first 100 m, which in turn depends on the vertical behaviour of the tagged animal. Based on our results, we recommend the use of temperature at depth summary data as opposed to temperature time series data for PAT studies; doing so during the tag programming will help to maximize the amount of transmitted time series data for other key data types such as light levels and depth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Protein structural alignment is one of the most fundamental and crucial areas of research in the domain of computational structural biology. Comparison of a protein structure with known structures helps to classify it as a new or belonging to a known group of proteins. This, in turn, is useful to determine the function of protein, its evolutionary relationship with other protein molecules and grasping principles underlying protein architecture and folding. Results: A large number of protein structure alignment methods are available. Each protein structure alignment tool has its own strengths andweaknesses that need to be highlighted.We compared and presented results of six most popular and publically available servers for protein structure comparison. These web-based servers were compared with the respect to functionality (features provided by these servers) and accuracy (how well the structural comparison is performed). The CATH was used as a reference. The results showed that overall CE was top performer. DALI and PhyreStorm showed similar results whereas PDBeFold showed the lowest performance. In case of few secondary structural elements, CE, DALI and PhyreStorm gave 100% success rate. Conclusion: Overall none of the structural alignment servers showed 100% success rate. Studies of overall performance, effect of mainly alpha and effect of mainly beta showed consistent performance. CE, DALI, FatCat and PhyreStorm showed more than 90% success rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Augmented Reality (AR) applications often require knowledge of the user’s position in some global coordinate system in order to draw the augmented content to its correct position on the screen. The most common method for coarse positioning is the Global Positioning System (GPS). One of the advantages of GPS is that GPS receivers can be found in almost every modern mobile device. This research was conducted in order to determine the accuracies of different GPS receivers. The tests included seven consumer-grade tablets, three external GPS modules and one professional-grade GPS receiver. All of the devices were tested with both static and mobile measurements. It was concluded that even the cheaper external GPS receivers were notably more accurate than the GPS receivers of the tested tablets. The absolute accuracy of the tablets is difficult to determine from the test results, since the results vary by a large margin between different measurements. The accuracy of the tested tablets in static measurements were between 0.30 meters and 13.75 meters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In our research we investigate the output accuracy of discrete event simulation models and agent based simulation models when studying human centric complex systems. In this paper we focus on human reactive behaviour as it is possible in both modelling approaches to implement human reactive behaviour in the model by using standard methods. As a case study we have chosen the retail sector, and here in particular the operations of the fitting room in the women wear department of a large UK department store. In our case study we looked at ways of determining the efficiency of implementing new management policies for the fitting room operation through modelling the reactive behaviour of staff and customers of the department. First, we have carried out a validation experiment in which we compared the results from our models to the performance of the real system. This experiment also allowed us to establish differences in output accuracy between the two modelling methods. In a second step a multi-scenario experiment was carried out to study the behaviour of the models when they are used for the purpose of operational improvement. Overall we have found that for our case study example both, discrete event simulation and agent based simulation have the same potential to support the investigation into the efficiency of implementing new management policies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background/aims: Few studies have validated the performance of guidelines for the prediction of choledocholithiasis (CL). Our objective was to prospectively assess the accuracy of the American Society for Gastrointestinal Endoscopy (ASGE) guidelines for the identification of CL. Methods: A two-year prospective evaluation of patients with suspected CL was performed. We evaluated the ASGE guidelines and its component variables in predicting CL. Results: A total of 256 patients with suspected CL were analyzed. Of the 208 patients with high-probability criteria for CL, 124 (59.6%) were found to have a stone/sludge at endoscopic retrograde cholangiopancreatography (ERCP). Among 48 patients with intermediate-probability criteria, 21 (43.8%) had a stone/sludge. The performance of ASGE high- and intermediate-probability criteria in our population had an accuracy of 59.0% (85.5% sensitivity, 24.3% specificity) and 41.0% (14.4% sensitivity, 75.6% specificity), respectively. The mean ERCP delay time was 6.1 days in the CL group and 6.4 days in the group without CL, p = 0.638. The presence of a common bile duct (CBD) > 6 mm (OR 2.21; 95% CI, 1.20-4.10), ascending cholangitis (OR 2.37; 95% CI, 1.01-5.55) and a CBD stone visualized on transabdominal US (OR 3.33; 95% CI, 1.48-7.52) were stronger predictors of CL. The occurrence of biliary pancreatitis was a strong protective factor for the presence of a retained CBD stone (OR 0.30; 95% CI, 0.17-0.55). Conclusions: Irrespective of a patient's ASGE probability for CL, the application of current guidelines in our population led to unnecessary performance of ERCPs in nearly half of cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Predicting accurate bond length alternations (BLAs) in long conjugated oligomers has been a significant challenge for electronic-structure methods for many decades, made particularly important by the close relationships between BLA and the rich optoelectronic properties of π-delocalized systems. Here, we test the accuracy of recently developed, and increasingly popular, double hybrid (DH) functionals, positioned at the top of Jacobs Ladder of DFT methods of increasing sophistication, computational cost, and accuracy, due to incorporation of MP2 correlation energy. Our test systems comprise oligomeric series of polyacetylene, polymethineimine, and polysilaacetylene up to six units long. MP2 calculations reveal a pronounced shift in BLAs between the 6-31G(d) basis set used in many studies of BLA to date and the larger cc-pVTZ basis set, but only modest shifts between cc-pVTZ and aug-cc-pVQZ results. We hence perform new reference CCSD(T)/cc-pVTZ calculations for all three series of oligomers against which we assess the performance of several families of DH functionals based on BLYP, PBE, and TPSS, along with lower-rung relatives including global- and range-separated hybrids. Our results show that DH functionals systematically improve the accuracy of BLAs relative to single hybrid functionals. xDH-PBE0 (N4 scaling using SOS-MP2) emerges as a DH functional rivaling the BLA accuracy of SCS-MP2 (N5 scaling), which was found to offer the best compromise between computational cost and accuracy the last time the BLA accuracy of DFT- and wave function-based methods was systematically investigated. Interestingly, xDH-PBE0 (XYG3), which differs to other DHs in that its MP2 term uses PBE0 (B3LYP) orbitals that are not self-consistent with the DH functional, is an outlier of trends of decreasing average BLA errors with increasing fractions of MP2 correlation and HF exchange.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Self-reported anthropometric data are commonly used to estimate prevalence of obesity in population and community-based studies. We aim to: 1) Determine whether survey participants are able and willing to self-report height and weight; 2) Assess the accuracy of self-reported compared to measured anthropometric data in a community-based sample of young people.

METHODS: Participants (16-29 years) of a behaviour survey, recruited at a Melbourne music festival (January 2011), were asked to self-report height and weight; researchers independently weighed and measured a sub-sample. Body Mass Index was calculated and overweight/obesity classified as ≥25 kg/m². Differences between measured and self-reported values were assessed using paired t-test/Wilcoxon signed ranks test. Accurate report of height and weight were defined as <2 cm and <2 kg difference between self-report and measured values, respectively. Agreement between classification of overweight/obesity by self-report and measured values was assessed using McNemar's test.

RESULTS: Of 1405 survey participants, 82% of males and 72% of females self-reported their height and weight. Among 67 participants who were also independently measured, self-reported height and weight were significantly less than measured height (p=0.01) and weight (p<0.01) among females, but no differences were detected among males. Overall, 52% accurately self-reported height, 30% under-reported, and 18% over-reported; 34% accurately self-reported weight, 52% under-reported and 13% over-reported. More females (70%) than males (35%) under-reported weight (p=0.01). Prevalence of overweight/obesity was 33% based on self-report data and 39% based on measured data (p=0.16).

CONCLUSIONS: Self-reported measurements may underestimate weight but accurately identified overweight/obesity in the majority of this sample of young people.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An initially wet contact filter paper test (IW-CFPT) and an initially dry contact filter paper test (ID-CFPT) were used to examine the wetting paths of geosynthetic clay liners, including non-contact filter paper tests for comparative purposes. The CFPTs were applied to both geosynthetic clay liner faces to examine the effect of geotextile type on capillary contact. The non-woven geotextile face was found to be more likely to cause capillary breaks than the woven geotextile face. Both IW- and ID-CFPTs were found to be applicable to geosynthetic clay liners within their accurate upper matric suction measurement limits of 146 kPa and 66 kPa, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The trade of the financial analyst is currently a much-debated issue in today’s media. As a large part of the investment analysis is conducted under the broker firms’ regime, the incentives of the financial analyst and the investor do not always align. The broker firm’s commercial incentives may be to maximise its commission from securities trading and underwriting fees. The purpose of this thesis is to extend our understanding of the work of a financial analyst, the incentives he faces and how these affect his actions. The first essay investigates how the economic significance of the coverage of a particular firm impacts the analysts’ accuracy of estimation. The hypothesis is that analysts put more effort in analysing firms with a relatively higher trading volume, as these firms usually yield higher commissions. The second essay investigates how analysts interpret new financial statement information. The essay shows that analysts underreact or overreact to prior reported earnings, depending on the short-term pattern in reported earnings. The third essay investigates the possible investment value in Finnish stock recommendations, issued by sell side analysts. It is established that consensus recommendations issued on Finnish stocks contain investment value. Further, the investment value in consensus recommendations improves significantly through the exclusion of recommendations issued by banks. The fourth essay investigates investors’ behaviour prior to financial analysts’ earnings forecast revisions. Lately, the financial press have reported cases were financial analysts warn their preferred clients of possible earnings forecast revisions. However, in the light of the empirical results, it appears that the problem of analysts leaking information to some selected customers does not appear systematically on the Finnish stock market.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

  Remote human activity monitoring is critical and essential in physiotherapy with respect to the skyrocketing healthcare expenditure and the fast aging population. One of frequently used method to monitor human activity is wearing inertial sensors since it is low-cost and accurate. However, the measurements of those sensors are able only to estimate the orientation and rotation angles with respect to actual movement angles, because of differences in the body’s co-ordination system and the sensor’s co-ordination system. There were numerous studies being conducted to improve the accuracy of estimation, though there is potential for further discussions on improving accuracy by replacing heavy algorithms to less complexity. This research is an attempt to propose an adaptive complementary filter for identifying human upper arm movements. Further, this article discusses a feasibility of upper arm rehabilitation using the proposed adaptive complementary filter and inertial measurement sensors. The proposed algorithm is tested with four healthy subjects wearing an inertial sensor against gold standard, which is the VICON system. It demonstrated root mean squared error of 8.77◦ for upper body limb orientation estimation when compared to gold standard VICON optical motion capture system.