868 resultados para Vertical crustal motion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility to measure brain perfusion using intravoxel incoherent motion (IVIM) MRI has been reported recently with currently clinically available technology. The method is intrinsically local and quantitative, but is contaminated by partial volume effects with cerebrospinal fluid (CSF). Signal from CSF can be suppressed by a 180° inversion recovery (180°-IR) magnetization preparation, but this also leads to strong suppression of blood and brain tissue signal. Here, we take advantage of the different T2 relaxations of blood and brain relative to CSF, and implement a T2 -prepared IVIM (T2prep IVIM) inversion recovery acquisition, which permits a recovery of between 43% and 57% of arterial and venous blood magnetization at excitation time compared with the theoretical recovery of between 27% and 30% with a standard 180°-IR. We acquired standard IVIM (IVIM), T2prep IVIM and dynamic susceptibility contrast (DSC) images at 3 T using a 32-multichannel receiver head coil in eight patients with known large high-grade brain tumors. We compared the contrast and contrast-to-noise ratio obtained in the corresponding cerebral blood volume images quantitatively, as well as subjectively by two neuroradiologists. Our findings suggest that quantitative cerebral blood volume contrast and contrast-to-noise ratio, as well as subjective lesion detection, contrast quality and diagnostic confidence, are increased with T2prep IVIM relative to IVIM and DSC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La aplicación de una serie de técnicas propias de la geotecnia vertical y de la consolidación de taludes y laderas inestables se presenta por primera vez aplicada a la rehabilitación de yacimientos pleistocenos ubicados en antiguas canteras. Un conjunto de actuaciones especializadas permite garantizar la seguridad en los trabajos así como la preservación de la integridad de los yacimientos ubicados en cortes verticales y laderas rocosas. La rehabilitación realizada en el yacimiento de la Cova del Rinoceront (macizo del Garraf, NE de España), ubicado en el frente de explotación de una antigua cantera de piedra caliza, es el primer ejemplo conocido en la Península Ibérica donde la geotecnia vertical hasido utilizada en este tipo de contextos y, por lo tanto, los resultados pueden ser utilizados como un posible modelo de futuro para próximas intervenciones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the psychometric properties of the Horizontal and Vertical Individualism and Collectivism Scale (HVIC) and the Auckland Individualism and Collectivism Scale (AICS). The sample consisted of 1,403 working individuals from Switzerland (N = 585) and from South Africa (N = 818). Principal component factor analyses indicated that a two-factor structure replicated well across the two countries for both scales. In addition, the HVIC four-factor structure replicated well across countries, whereas the responsibility dimension of individualism of the AICS replicated poorly. Confirmatory factor analyses provided satisfactory support to the original theoretical models for both the HVIC and the AICS. Equivalence measurement indices indicated that the cross-cultural replicability properties of both instruments are generally acceptable. However, canonical correlations and correlations between the HVIC and AICS dimensions confirm that these two instruments differ in their underlying meaning of the individualism and collectivism constructs, suggesting that these two instruments assess individualism and collectivism differently.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The existence of fluids and partial melt in the lower crust of the seismically active Kutch rift basin (on the western continental margin of India) owing to underplating has been proposed in previous geological and geophysical studies. This hypothesis is examined using magnetotelluric (MT) data acquired at 23 stations along two profiles across Kutch Mainland Uplift and Wagad Uplift. A detailed upper crustal structure is also presented using twodimensional inversion of MT data in the Bhuj earthquake (2001) area. The prominent boundaries of reflection in the upper crust at 5, 10 and 20 km obtained in previous seismic reflection profiles correlate with conductive structures in our models. The MT study reveals 1-2 km thick Mesozoic sediments under the Deccan trap cover. The Deccan trap thickness in this region varies from a few meters to 1.5 km. The basement is shallow on the northern side compared to the south and is in good agreement with geological models as well as drilling information. The models for these profiles indicate that the thickness of sediments would further increase southwards into the Gulf of Kutch. Significant findings of the present study indicate 1) the hypocentre region of the earthquake is devoid of fluids, 2) absence of melt (that is emplaced during rifting as suggested from the passive seismological studies) in the lower crust and 3) a low resistive zone in the depth range of 5-20 km. The present MT study rules out fluidsand melt (magma) as the causative factors that triggered the Bhuj earthquake. The estimated porosity value of 0.02% will explain 100-500 ohm·m resistivity values observed in the lower crust. Based on the seismic velocities and geochemical studies, presence of garnet is inferred. The lower crust consists of basalts - probably generated by partial melting of metasomatised garnet peridotite at deeper depths in the lithosphere - and their composition might be modified by reaction with the spinel peridotites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this note we prove an existence and uniqueness result for the solution of multidimensional stochastic delay differential equations with normal reflection. The equations are driven by a fractional Brownian motion with Hurst parameter H > 1/2. The stochastic integral with respect to the fractional Brownian motion is a pathwise Riemann¿Stieltjes integral.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the Cauchy problem for a stochastic delay differential equation driven by a fractional Brownian motion with Hurst parameter H>¿. We prove an existence and uniqueness result for this problem, when the coefficients are sufficiently regular. Furthermore, if the diffusion coefficient is bounded away from zero and the coefficients are smooth functions with bounded derivatives of all orders, we prove that the law of the solution admits a smooth density with respect to Lebesgue measure on R.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El pie plano astrágalo vertical congénito es una deformidad poco frecuente que se puede encontrar de forma aislada, dentro de un cuadro polimalformativo o en relación con afectaciones neurológicas. Se caracteriza por una luxación del escafoides por encima del astrágalo,lo que provoca un pie rígido o de dificil manipulación. En este artículo los autores describen un caso clínico de un paciente que acude a consulta por presentar una inflamación dolorosa en la zona de la cabeza del astrágalo del pie derecho. Una vez realizado todo el protocolo exploratorio, se plantea la resolución mediante un plan de tratamiento en dos fases: una primera fase consistente en la realización de paracentesis evacuadora o terapéutica-curativa; y una segunda fase en la que se diseña tratamiento ortopodológlco de descarga.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility of intravoxel incoherent motion (IVIM) perfusion measurements in the brain with currently available imaging systems. MATERIALS AND METHODS: We acquired high in-plane resolution (1.2 × 1.2 mm(2) ) diffusion-weighted images with 16 different values of b ranging from 0 to 900 s/mm(2) , in three orthogonal directions, on 3T systems with a 32-multichannel receiver head coil. IVIM perfusion maps were extracted by fitting a double exponential model of signal amplitude decay. Regions of interest were drawn in pathological and control regions, where IVIM perfusion parameters were compared to the corresponding dynamic susceptibility contrast (DSC) parameters. RESULTS: Hyperperfusion was found in the nonnecrotic or cystic part of two histologically proven glioblastoma multiforme and in two histologically proven glioma WHO grade III, as well as in a brain metastasis of lung adenocarcinoma, in a large meningioma, and in a case of ictal hyperperfusion. A monoexponential decay was found in a territory of acute ischemia, as well as in the necrotic part of a glioblastoma. The IVIM perfusion fraction f correlated well with DSC CBV. CONCLUSION: Our initial report suggests that high-resolution brain perfusion imaging is feasible with IVIM in the current clinical setting. J. Magn. Reson. Imaging 2014;39:624-632. © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relaxation rates provide important information about tissue microstructure. Multi-parameter mapping (MPM) estimates multiple relaxation parameters from multi-echo FLASH acquisitions with different basic contrasts, i.e., proton density (PD), T1 or magnetization transfer (MT) weighting. Motion can particularly affect maps of the apparent transverse relaxation rate R2(*), which are derived from the signal of PD-weighted images acquired at different echo times. To address the motion artifacts, we introduce ESTATICS, which robustly estimates R2(*) from images even when acquired with different basic contrasts. ESTATICS extends the fitted signal model to account for inherent contrast differences in the PDw, T1w and MTw images. The fit was implemented as a conventional ordinary least squares optimization and as a robust fit with a small or large confidence interval. These three different implementations of ESTATICS were tested on data affected by severe motion artifacts and data with no prominent motion artifacts as determined by visual assessment or fast optical motion tracking. ESTATICS improved the quality of the R2(*) maps and reduced the coefficient of variation for both types of data-with average reductions of 30% when severe motion artifacts were present. ESTATICS can be applied to any protocol comprised of multiple 2D/3D multi-echo FLASH acquisitions as used in the general research and clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively--or optionally retrospectively--correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity≥92%, specificity>98%). Motion detection triggered an additional image volume acquisition with b=0 s/mm2 which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The highway departments of all fifty states were contacted to find the extent of application of integral abutment bridges, to survey the different guidelines used for analysis and design of integral abutment bridges, and to assess the performance of such bridges through the years. The variation in design assumptions and length limitations among the various states in their approach to the use of integral abutments is discussed. The problems associated with lateral displacements at the abutment, and the solutions developed by the different states for most of the ill effects of abutment movements are summarized in the report. An algorithm based on a state-of-the-art nonlinear finite element procedure was developed and used to study piling stresses and pile-soil interaction in integral abutment bridges. The finite element idealization consists of beam-column elements with geometric and material nonlinearities for the pile and nonlinear springs for the soil. An idealized soil model (modified Ramberg-Osgood model) was introduced in this investigation to obtain the tangent stiffness of the nonlinear spring elements. Several numerical examples are presented in order to establish the reliability of the finite element model and the computer software developed. Three problems with analytical solutions were first solved and compared with theoretical solutions. A 40 ft H pile (HP 10 X 42) in six typical Iowa soils was then analyzed by first applying a horizontal displacement (to simulate bridge motion) and no rotation at the top and then applying a vertical load V incrementally until failure occurred. Based on the numerical results, the failure mechanisms were generalized to be of two types: (a) lateral type failure and (b) vertical type failure. It appears that most piles in Iowa soils (sand, soft clay and stiff clay) failed when the applied vertical load reached the ultimate soil frictional resistance (vertical type failure). In very stiff clays, however, the lateral type failure occurs before vertical type failure because the soil is sufficiently stiff to force a plastic hinge to form in the pile as the specified lateral displacement is applied. Preliminary results from this investigation showed that the vertical load-carrying capacity of H piles is not significantly affected by lateral displacements of 2 inches in soft clay, stiff clay, loose sand, medium sand and dense sand. However, in very stiff clay (average blow count of 50 from standard penetration tests), it was found that the vertical load carrying capacity of the H pile is reduced by about 50 percent for 2 inches of lateral displacement and by about 20 percent for lateral displacement of 1 inch. On the basis of the preliminary results of this investigation, the 265-feet length limitation in Iowa for integral abutment concrete bridges appears to be very conservative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a parallel architecture for a motion estimation algorithm. It is well known that image processing requires a huge amount of computation, mainly at low level processing where the algorithms are dealing with a great numbers of data-pixel. One of the solutions to estimate motions involves detection of the correspondences between two images. Due to its regular processing scheme, parallel implementation of correspondence problem can be an adequate approach to reduce the computation time. This work introduces parallel and real-time implementation of such low-level tasks to be carried out from the moment that the current image is acquired by the camera until the pairs of point-matchings are detected

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comprehensive field detection method is proposed that is aimed at developing advanced capability for reliable monitoring, inspection and life estimation of bridge infrastructure. The goal is to utilize Motion-Sensing Radio Transponders (RFIDS) on fully adaptive bridge monitoring to minimize the problems inherent in human inspections of bridges. We developed a novel integrated condition-based maintenance (CBM) framework integrating transformative research in RFID sensors and sensing architecture, for in-situ scour monitoring, state-of-the-art computationally efficient multiscale modeling for scour assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the impact of in-plane coronary artery motion on coronary magnetic resonance angiography (MRA) and coronary MR vessel wall imaging. Free-breathing, navigator-gated, 3D-segmented k-space turbo field echo ((TFE)/echo-planar imaging (EPI)) coronary MRA and 2D fast spin-echo coronary vessel wall imaging of the right coronary artery (RCA) were performed in 15 healthy adult subjects. Images were acquired at two different diastolic time periods in each subject: 1) during a subject-specific diastasis period (in-plane velocity <4 cm/second) identified from analysis of in-plane coronary artery motion, and 2) using a diastolic trigger delay based on a previously implemented heart-rate-dependent empirical formula. RCA vessel wall imaging was only feasible with subject-specific middiastolic acquisition, while the coronary wall could not be identified with the heart-rate-dependent formula. For coronary MRA, RCA border definition was improved by 13% (P < 0.001) with the use of subject-specific trigger delay (vs. heart-rate-dependent delay). Subject-specific middiastolic image acquisition improves 3D TFE/EPI coronary MRA, and is critical for RCA vessel wall imaging.