987 resultados para Valvular prosthesis
Resumo:
Prenatal heart valve interventions aiming at the early and systematic correction of congenital cardiac malformations represent a promising treatment option in maternal-fetal care. However, definite fetal valve replacements require growing implants adaptive to fetal and postnatal development. The presented study investigates the fetal implantation of prenatally engineered living autologous cell-based heart valves. Autologous amniotic fluid cells (AFCs) were isolated from pregnant sheep between 122 and 128 days of gestation via transuterine sonographic sampling. Stented trileaflet heart valves were fabricated from biodegradable PGA-P4HB composite matrices (n = 9) and seeded with AFCs in vitro. Within the same intervention, tissue engineered heart valves (TEHVs) and unseeded controls were implanted orthotopically into the pulmonary position using an in-utero closed-heart hybrid approach. The transapical valve deployments were successful in all animals with acute survival of 77.8% of fetuses. TEHV in-vivo functionality was assessed using echocardiography as well as angiography. Fetuses were harvested up to 1 week after implantation representing a birth-relevant gestational age. TEHVs showed in vivo functionality with intact valvular integrity and absence of thrombus formation. The presented approach may serve as an experimental basis for future human prenatal cardiac interventions using fully biodegradable autologous cell-based living materials.
Resumo:
A new, investigational, parenteral form of sparfloxacin was compared with ceftriaxone in the treatment of experimental endocarditis caused by either of three penicillin-susceptible streptococci or one penicillin-resistant streptococcus. Both drugs have prolonged half-lives in serum, allowing single daily administration to humans. Sparfloxacin had relatively low MICs (0.25 to 0.5 mg/liter) for all four organisms and was also greater than or equal to eight times more effective than the other quinolones against 21 additional streptococcal isolates recovered from patients with bacteremia. Ceftriaxone MICs were 0.032 to 0.064 mg/liter for the penicillin-susceptible strains and 2 mg/liter for the resistant isolate. Both antibiotics resulted in moderate bacterial killing in vitro. Rats with catheter-induced aortic vegetations were inoculated with 10(7) CFU of the test organisms. Antibiotic treatment was started 48 h later and lasted either 3 or 5 days. The drugs were injected at doses which mimicked the kinetics in human serum produced by one intravenous injection of 400 mg of sparfloxacin (i.e., the daily dose expected to be given to human adults) and 2 g of ceftriaxone. Both antibiotics significantly decreased the bacterial densities in the vegetations. However, sparfloxacin was slower than ceftriaxone in its ability to eradicate valvular infection caused by penicillin-susceptible bacteria. While this difference was quite marked after 3 days of therapy, it tended to vanish when treatment was prolonged to 5 days. In contrast, sparfloxacin was very effective against the penicillin-resistant isolate, an organism against which ceftriaxone therapy failed in vivo. No sparfloxacin-resistant mutant was selected during therapy. Thus, in the present experimental setting, this new, investigational, parenteral form of sparfloxacin was effective against severe infections caused by both penicillin-susceptible and penicillin-resistant streptococci.
Resumo:
BACKGROUND: All patients with extensive resection of the anterolateral chest wall and the sternum followed by reconstruction with methylmethacrylate substitutes were assessed prospectively 6 months after the operation to delineate chest wall integrity with pulmonary function and cine-magnetic resonance imaging. METHODS: Twenty-six patients underwent chest wall reconstruction by use of methylmethacrylate between 1994 and 1998 due to primary tumors in 35%, metastases in 27%, T3 lung cancer in 19%, and debridement for radionecrosis and osteomyelitis in 19% of patients. Three to eight ribs were resected and additional sternum resection was performed in 39% of patients. RESULTS: There was no 30-day mortality. All patients were extubated after the operation without need for reintubation. Prosthesis dislocation occurred in 1 patient and infection in 2 patients during follow-up. Nineteen patients (73%) suffered no restrictions of daily activities. Clinical examination revealed normal shoulder girdle function in 77% of patients. There was no significant difference between preoperative and postoperative FEV1 (forced expiratory volume in 1 second) measurements in patients with lobectomy or wedge resections. Cinemagnetic resonance imaging revealed concordant chest wall movements during respiration in 92% of patients without paradoxical movements or implant dislocations being observed. CONCLUSIONS: Large defects of the anterolateral chest wall and sternum can be reconstructed efficiently with methylmethacrylate substitutes with minimal morbidity and excellent cosmetic and functional outcome.
Resumo:
The diagnostic yield of prosthetic joint-associated infection is hampered by the phenotypic change of bacteria into a sessile and resistant form, also called biofilm. With sonication, adherent bacteria can be dislodged from the prosthesis. Species identification may be difficult because of their variations in phenotypic appearance and biochemical reaction. We have studied the phenotypic, genotypic, and biochemical properties of Escherichia coli variants isolated from a periprosthetic joint infection. The strains were collected from synovial fluid, periprosthetic tissue, and fluid from the explanted and sonicated prosthesis. Isolates from synovial fluid revealed a normal phenotype, whereas a few variants from periprosthetic tissue and all isolates from sonication fluid showed different morphological features (including small-colony variants). All isolates from sonication fluid were beta-galactosidase negative and nonmotile; most were indole negative. Because of further variations in biochemical properties, species identification was false or not possible in 50% of the isolates included in this study. In contrast to normal phenotypes, variants were resistant to aminoglycosides. Typing of the isolates using pulsed-field gel electrophoresis yielded nonidentical banding patterns, but all strains were assigned to the same clonal origin when compared with 207 unrelated E. coli isolates. The bacteria were repeatedly passaged on culture media and reanalyzed. Thereafter, most variants reverted to normal phenotype and regained their motility and certain biochemical properties. In addition, some variants displayed aminoglycoside susceptibility after reversion. Sonication of an explanted prosthesis allows insight into the lifestyle of bacteria in biofilms. Since sonication fluid also reveals dislodged sessile forms, species identification of such variants may be misleading.
Resumo:
The Atripump is a motorless, volume displacement pump based on artificial muscle technology that could reproduce the pump function of normal atrium. It could help prevent blood clots due to blood stagnation and eventually avoid anticoagulation therapy in atrial fibrillation (AF). An animal study has been designed to assess mechanical effects of this pump on fibrillating atrium. The Atripump is a dome shaped silicone coated nitinol actuator. A pacemaker like control unit drives the actuator. In five adult sheep, the right atrium (RA) was exposed and dome sutured onto the epicardium. Atrial fibrillation was induced using rapid epicardial pacing (600 beats/min). Ejection fraction of the RA was obtained with intracardiac ultrasound in baseline, AF and Atripump assisted AF conditions. The dome's contraction rate was 60/min with power supply of 12V, 400 mA for 200 ms and ran for 2 hours in total. Mean temperature on the RA was 39+/-1.5 degrees C. Right atrium ejection fraction was 31% in baseline conditions, 5% and 20% in AF and assisted AF, respectively. In two animals a thrombus appeared in the right appendix and washed out once the pump was turned on. The Atripump washes blood out the RA acting as an anticoagulant device. Possible clinical implications in patients with chronic AF are prevention of embolism of cardiac origin and avoidance of hemorrhagic complication due to chronic anticoagulation.
Resumo:
C.difficle surveillance report quarter July-September 2015 .pdf C.difficle surveillance report quarter April-June 2015.pdf C.difficle surveillance report quarter January - March 2015.pdf C.difficle surveillance report quarter ending Oct - Dec 2014.pdf C.difficle surveillance report quarter ending July - Sept 2014.pdf C.difficle sureillance report quarter ending April - June 2014.pdf C.difficle surveillance report quarter endin January - March 2014.pdf C.difficle surveillance report quarter ending October to December 2013.pdf C.difficle surveillance report quarter ending 1st July 2013 to 30th September 2013.pdf C.difficle surveillance report quarter ending 1 April 2013 to 30 June 2013.pdf C.difficle Surveillance Report Quarter Ending 31st March 2013.pdf.pdf C.difficle Surveillance Report Quarter Ending 31st December 2012.pdf C.difficile Surveillance Report quarter ending 30 September 2012.pdf.pdf� C.difficile Surveillance Report quarter ending 30 June 2012.pdf C.difficile Surveillance Report quarter ending March 2012 C.difficile Surveillance Report quarter ending December 2011 C.difficile Surveillance Report quarter ending September 2011.pdf C. difficle Surveillance Report quarter ending June 2011.pdf C. difficile Surveillance Report quarter ending March 2011 (930KB).pdf CDI_Report Oct-Dec 2010_2.pdf Staphylococcus aureus S.aureus bacteraemia surveillance quart July-September 2015.pdf S.aureus surveillance report quarter April-June 2015.pdf S.aureus surveillance report quarter January - March 2015.pdf S.aureus surveillance report quarter Oct - Dec 2014.pdf S.aureus sureveillance report quarter July - Sept 2014.pdf S.aureus surveillance report quarter April - June 2014.pdf S. aureus surveillance report quarter January - March 2014.pdf S. aureus surveillance report quarter ending October to December 2013.pdf S. aureus surveillance report quarter ending 1st July 2013 to 30th September 2013.pdf S. aureus surveillance report quarter ending 1 April 2013 to 30 June 2013 S.aureus Surveillance Report Quarter Ending 31st March 2013.pdf.pdf S.aureus Surveillance Report Quarter Ending 31st December 2012.pdf S.aureus Surveillance Report quarter ending 30 September 2012.pdf.pdf S.aureus Surveillance Report quarter ending 30 June 2012.pdf S.aureus Surveillance Report quarter ending March 2012 S.aureus Surveillance Report quarter ending�December 2011 S.aureus Surveillance Report quarter ending September 2011.pdf S.aureus Surveillance Report quarter ending June 2011.pdf S.aureus Surveillance Report quarter ending March 2011 (999KB).pdf Surgical site infectionCumulative incidence of SSI within 30 days after Caesarean section, Reporting Year 2009 (post-discharge excluded) Cumulative incidence of SSI within 30 days after hip prosthesis, Reporting Year 2009 (post-discharge excluded) Cumulative incidence of SSI within 30 days after knee prosthesis, Reporting Year 2009 (post-discharge excluded) � �
Resumo:
Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions.
Resumo:
BACKGROUND. Total knee (TKR) and hip (THR) replacement (arthroplasty) are effective surgical procedures that relieve pain, improve patients' quality of life and increase functional capacity. Studies on variations in medical practice usually place the indications for performing these procedures to be highly variable, because surgeons appear to follow different criteria when recommending surgery in patients with different severity levels. We therefore proposed a study to evaluate inter-hospital variability in arthroplasty indication. METHODS. The pre-surgical condition of 1603 patients included was compared by their personal characteristics, clinical situation and self-perceived health status. Patients were asked to complete two health-related quality of life questionnaires: the generic SF-12 (Short Form) and the specific WOMAC (Western Ontario and Mcmaster Universities) scale. The type of patient undergoing primary arthroplasty was similar in the 15 different hospitals evaluated.The variability in baseline WOMAC score between hospitals in THR and TKR indication was described by range, mean and standard deviation (SD), mean and standard deviation weighted by the number of procedures at each hospital, high/low ratio or extremal quotient (EQ5-95), variation coefficient (CV5-95) and weighted variation coefficient (WCV5-95) for 5-95 percentile range. The variability in subjective and objective signs was evaluated using median, range and WCV5-95. The appropriateness of the procedures performed was calculated using a specific threshold proposed by Quintana et al for assessing pain and functional capacity. RESULTS. The variability expressed as WCV5-95 was very low, between 0.05 and 0.11 for all three dimensions on WOMAC scale for both types of procedure in all participating hospitals. The variability in the physical and mental SF-12 components was very low for both types of procedure (0.08 and 0.07 for hip and 0.03 and 0.07 for knee surgery patients). However, a moderate-high variability was detected in subjective-objective signs. Among all the surgeries performed, approximately a quarter of them could be considered to be inappropriate. CONCLUSIONS. A greater inter-hospital variability was observed for objective than for subjective signs for both procedures, suggesting that the differences in clinical criteria followed by surgeons when indicating arthroplasty are the main responsible factors for the variation in surgery rates.
Resumo:
To date, myxoma on a mechanical valve annulus has not been reported. The case is reported of a 74-year-old woman who was admitted to hospital following the identification of an intracardiac tumor mass. Six years previously, the patient had received a mechanical valve implanted in the mitral position. Transesophageal echocardiography revealed a mobile hypoechogenic tumorous mass attached to the anterior annulus of the prosthesis. The tumor was successfully treated by surgical excision, and a diagnosis of myxoma was confirmed both clinically and pathologically.
Resumo:
Transcatheter aortic valve implantation is an expanding procedure thus far restricted to a target population of old and high-comorbidity patients with symptomatic aortic stenosis. The need for bulky devices (up to 24F) combined with the high prevalence of peripheral vascular disease in these patients explains the increased risk of vascular complications in transfemoral Edwards Sapien (Edwards Lifesciences, Irvine, Calif) transcatheter aortic valve implantation procedures, with a rate of 20% for the transfemoral arm of either the Placement of AoRTic traNscathetER valves in the European Union (PARTNER EU) trial or the SOURCE Registry.1,2
Resumo:
Hip or knee arthroplasty is proposed after osteoarthritis or an accident. It is decided after a long path of pain and decrease in the quality of life. This research explores the period of illness until surgery. Twenty-four semi-structured interviews were conducted one month before surgery and a thematic discourse analysis performed. The diversity and complexity of the patient experience, in a commonly performed surgical intervention underlines important topics, requiring attention in order to improve patient preparations and information prior to arthroplasty: information adapted to individual concerns, needs and representations. Psychological and physical acceptance is necessary for integration of the prosthesis.
Resumo:
BACKGROUND: The Contegra® is a conduit made from the bovine jugular vein and then interposed between the right ventricle and the pulmonary artery. It is used for cardiac malformations in the reconstruction of right ventricular outflow tract. OBJECTIVE: To describe both normal and pathological appearances of the Contegra® in radiological imaging, to describe imaging of complications and to define the role of CT and MRI in postoperative follow-up. MATERIALS AND METHODS: Forty-three examinations of 24 patients (17 boys and 7 girls; mean age: 10.8 years old) with Contegra® conduits were reviewed. Anatomical description and measurements of the conduits were performed. Pathological items examined included stenosis, dilatation, plicature or twist, thrombus or vegetations, calcifications and valvular regurgitation. Findings were correlated to the echographic gradient through the conduit when available. RESULTS: CT and MR work-up showed Contegra® stenosis (n = 12), dilatation (n = 9) and plicature or twist (n = 7). CT displayed thrombus or vegetations in the Contegra® in three clinically infected patients. Calcifications of the conduit were present at CT in 12 patients and valvular regurgitation in three patients. The comparison between CT and/or MR results showed a good correlation between the echographic gradient and the presence of stenosis in the Contegra®. CONCLUSION: CT and MR bring additional information about permeability and postoperative anatomy especially when echocardiography is inconclusive. Both techniques depict the normal appearance of the conduit, and allow comparison and precise evaluation of changes in the postoperative follow-up.