934 resultados para Time-domain Method
Resumo:
Transient response of an adsorbing or non-adsorbing tracer injected as step or square pulse input in a diffusion cell with two flowing streams across the pellet is theoretically investigated in this paper. Exact solutions and the asymptotic solutions in the time domain and in three different limits are obtained by using an integral transform technique and a singular perturbation technique, respectively. Parametric dependence of the concentrations in the top and bottom chambers can be revealed by investigating the asymptotic solutions, which are far simpler than their exact counterpart. In the time domain investigation, it is found that the bottom-chamber concentration is very sensitive to the value of the macropore effective diffusivity. Therefore this concentration could be used to extract diffusivity by fitting in the time domain. The bottom-chamber concentration is also sensitive to flow rate, pellet length chamber volume and the type of input (step and square input).
Resumo:
We present a method of estimating HIV incidence rates in epidemic situations from data on age-specific prevalence and changes in the overall prevalence over time. The method is applied to women attending antenatal clinics in Hlabisa, a rural district of KwaZulu/Natal, South Africa, where transmission of HIV is overwhelmingly through heterosexual contact. A model which gives age-specific prevalence rates in the presence of a progressing epidemic is fitted to prevalence data for 1998 using maximum likelihood methods and used to derive the age-specific incidence. Error estimates are obtained using a Monte Carlo procedure. Although the method is quite general some simplifying assumptions are made concerning the form of the risk function and sensitivity analyses are performed to explore the importance of these assumptions. The analysis shows that in 1998 the annual incidence of infection per susceptible woman increased from 5.4 per cent (3.3-8.5 per cent; here and elsewhere ranges give 95 per cent confidence limits) at age 15 years to 24.5 per cent (20.6-29.1 per cent) at age 22 years and declined to 1.3 per cent (0.5-2.9 per cent) at age 50 years; standardized to a uniform age distribution, the overall incidence per susceptible woman aged 15 to 59 was 11.4 per cent (10.0-13.1 per cent); per women in the population it was 8.4 per cent (7.3-9.5 per cent). Standardized to the age distribution of the female population the average incidence per woman was 9.6 per cent (8.4-11.0 per cent); standardized to the age distribution of women attending antenatal clinics, it was 11.3 per cent (9.8-13.3 per cent). The estimated incidence depends on the values used for the epidemic growth rate and the AIDS related mortality. To ensure that, for this population, errors in these two parameters change the age specific estimates of the annual incidence by less than the standard deviation of the estimates of the age specific incidence, the AIDS related mortality should be known to within +/-50 per cent and the epidemic growth rate to within +/-25 per cent, both of which conditions are met. In the absence of cohort studies to measure the incidence of HIV infection directly, useful estimates of the age-specific incidence can be obtained from cross-sectional, age-specific prevalence data and repeat cross-sectional data on the overall prevalence of HIV infection. Several assumptions were made because of the lack of data but sensitivity analyses show that they are unlikely to affect the overall estimates significantly. These estimates are important in assessing the magnitude of the public health problem, for designing vaccine trials and for evaluating the impact of interventions. Copyright (C) 2001 John Wiley & Sons, Ltd.
Resumo:
It has recently been stated that the parametrization of the time variables in the one-dimensional (I-D) mixing-frequency electron spin-echo envelope modulation (MIF-ESEEM) experiment is incorrect and hence the wrong frequencies for correlated nuclear transitions are predicted. This paper is a direct response to such a claim, its purpose being to show that the parametrization in land 2-D MIF-ESEEM experiments possesses the same form as that used in other 4-pulse incrementation schemes and predicts the same correlation frequencies. We show that the parametrization represents a shearing transformation of the 2-D time-domain and relate the resulting frequency domain spectrum to the HYSCORE spectrum in terms of a skew-projection. It is emphasized that the parametrization of the time-domain variables may be chosen arbitrarily and affects neither the computation of the correct nuclear frequencies nor the resulting resolution. The usefulness or otherwise of the MIF parameters \gamma\ > 1 is addressed, together with the validity of the original claims of the authors with respect to resolution enhancement in cases of purely homogeneous and inhomogeneous broadening. Numerical simulations are provided to illustrate the main points.
Resumo:
Obesity is associated with increased sympathetic activity and higher mortality. Treatment of this condition is often frustrating. Roux-en-Y gastric bypass is the most effective technique nowadays for treatment of obesity. The aim of the present study is to assess the effects of this surgery on the cardiac autonomic activity, including the influence of gender and age, through heart rate variability (HRV) analysis. The study group consisted of 71 obese patients undergoing gastric bypass. Time domain measures of HRV, obtained from 24-h Holter recordings, were evaluated before and 6 months after surgery, and the results were compared. Percentage of interval differences of successive normal sinus beats greater than 50 ms (pNN50) and square root of the mean squared differences of successive normal sinus beat intervals (rMSSD) was used to estimate the short-term components of HRV, related to the parasympathetic activity. Standard deviation of intervals between all normal sinus beats (SDNN) was related to overall HRV. SDNN, pNN50, and rMSSD showed significant increase 6 months after surgery (p < 0.001, p = 0.001 and p = 0.002, respectively). Men presented a greater increase of SDNN than women (p = 0.006) during the follow-up. There was a difference in rMSSD evolution for age groups (p = 0.002). Only younger patients presented significant increase of rMSSD. Overall HRV increased 6 months after surgery; this increase was more evident in men. Cardiac parasympathetic activity increased also, but in younger patients only.
Resumo:
Background: The relation between left ventricular filing velocities determined by Doppler echocardiography and autonomic nervous system function assessed by heart rate variability (HRV) is unclear. The aim of this study was to evaluate the influence of the autonomic nervous system assessed by the time and frequency domain indices of HRV in the Doppler indices of left ventricular diastolic filling velocities in patients without heart disease. Methods: We studied 451 healthy individuals (255 female [56.4%]) with normal blood pressure, electrocardiogram, chest x-ray, and treadmill electrocardiographic exercise stress test results, with a mean age of 43 +/- 12 (range 15-82) years, who underwent transthoracic Doppler echocardiography and 24-hour electrocardiographic ambulatory monitoring. We studied indices of HRV on time (standard deviation [SD] of all normal sinus RR intervals during 24 hours, SD of averaged normal sinus RR intervals for all 5-minute segments, mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms) and frequency (low frequency, high frequency, very low frequency, low frequency/high frequency ratio) domains relative to peak flow velocity during rapid passive filling phase (E), atrial contraction (A), E/A ratio, E-wave deceleration time, and isovolumic relaxation time. Statistical analysis was performed with Pearson correlation and logistic regression. Results: Peak flow velocity during rapid passive filling phase (E) and atrial contraction (A), E/A ratio, and deceleration time of early mitral inflow did not demonstrate a significant correlation with indices of HRV in time and frequency domain. We found that the E/A ratio was < 1 in 45 individuals (10%). Individuals with an E/A ratio < 1 had lower indices of HRV in frequency domain (except low frequency/high frequency) and lower indices of the mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms in time domain. Logistic regression demonstrated that an E/A ratio < 1 was associated with lower HF. Conclusion: Individuals with no evidence of heart disease and an E/A ratio < 1 demonstrated a significant decrease in indexes of HRV associated with parasympathetic modulation. (J Am Soc Echocardiogr 2010;23: 762-5.)
Resumo:
PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093
Resumo:
Genomic imprinting alterations have been shown to be associated with assisted reproductive technologies (ARTs) in animals. At present, data obtained in humans are inconclusive; however, some epidemiological studies have demonstrated an increased incidence of imprinting disorders in children conceived by ARTs. In the present study, we focused on the effect of ARTs [IVF and intracytoplasmic sperm injection (ICSI)] on the epigenetic reprogramming of the maternally methylated imprinting control region KvDMR1 in clinically normal children. Qualitative and quantitative methylation at KvDMR1 were assessed by the methylation-specific PCR approach and by the methylation-sensitive enzymatic digestion associated with real-time PCR method, respectively. DNA was obtained from peripheral blood of 12/18 and umbilical cord blood and placenta of 6/18 children conceived by IVF or ICSI. The methylation patterns observed in this group were compared with the patterns observed in 30 clinically normal naturally conceived children (negative controls) and in 3 naturally conceived Beckwith-Wiedemann syndrome patients (positive controls). Hypomethylation at KvDMR1 was observed in 3/18 clinically normal children conceived by ARTs (2 conceived by IVF and 1 by ICSI). A discordant methylation pattern was observed in the three corresponding dizygotic twins. Our findings corroborate the hypothesis of vulnerability of maternal imprinting to ARTs. Furthermore, the discordant methylation at KvDMR1 observed between dizygotic twins could be consequent to one of the following possibilities: (i) a differential vulnerability of maternal imprints among different embryos; or (ii) epimutations that occurred during gametogenesis resulting in the production of oocytes without the correct primary imprint at KvDMR1.
Resumo:
Borges GR, Salgado HC, Silva CA, Rossi MA, Prado CM, Fazan R Jr. Changes in hemodynamic and neurohumoral control cause cardiac damage in one-kidney, one-clip hypertensive mice. Am J Physiol Regul Integr Comp Physiol 295: R1904-R1913, 2008. First published October 1, 2008; doi:10.1152/ajpregu.00107.2008.-Sympathovagal balance and baroreflex control of heart rate (HR) were evaluated during the development (1 and 4 wk) of one-kidney, one-clip (1K1C) hypertension in conscious mice. The development of cardiac hypertrophy and fibrosis was also examined. Overall variability of systolic arterial pressure (AP) and HR in the time domain and baroreflex sensitivity were calculated from basal recordings. Methyl atropine and propranolol allowed the evaluation of the sympathovagal balance to the heart and the intrinsic HR. Staining of renal ANG II in the kidney and plasma renin activity (PRA) were also evaluated. One and four weeks after clipping, the mice were hypertensive and tachycardic, and they exhibited elevated sympathetic and reduced vagal tone. The intrinsic HR was elevated only 1 wk after clipping. Systolic AP variability was elevated, while HR variability and baroreflex sensitivity were reduced 1 and 4 wk after clipping. Renal ANG II staining and PRA were elevated only 1 wk after clipping. Concentric cardiac hypertrophy was observed at 1 and 4 wk, while cardiac fibrosis was observed only at 4 wk after clipping. In conclusion, these data further support previous findings in the literature and provide new features of neurohumoral changes during the development of 1K1C hypertension in mice. In addition, the 1K1C hypertensive model in mice can be an important tool for studies evaluating the role of specific genes relating to dependent and nondependent ANG II hypertension in transgenic mice.
Resumo:
The step size determines the accuracy of a discrete element simulation. The position and velocity updating calculation uses a pre-calculated table and hence the control of step size can not use the integration formulas for step size control. A step size control scheme for use with the table driven velocity and position calculation uses the difference between the calculation result from one big step and that from two small steps. This variable time step size method chooses the suitable time step size for each particle at each step automatically according to the conditions. Simulation using fixed time step method is compared with that of using variable time step method. The difference in computation time for the same accuracy using a variable step size (compared to the fixed step) depends on the particular problem. For a simple test case the times are roughly similar. However, the variable step size gives the required accuracy on the first run. A fixed step size may require several runs to check the simulation accuracy or a conservative step size that results in longer run times. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
We present an ultra-high bandwidth all-optical digital signal regeneration device concept utilising non-degenerate parametric interaction in a one-dimensional waveguide. Performance is analysed in terms of re-amplification, re-timing, and re-shaping (including centre frequency correction) of time domain multiplexed signals. Bandwidths of 10-100 THz are achievable. (C) 2001 Published by Elsevier Science B.V.
Resumo:
We present the quantum theory of the far-off-resonance continuous-wave Raman laser using the Heisenberg-Langevin approach. We show that the simplified quantum Langevin equations for this system are mathematically identical to those of the nondegenerate optical parametric oscillator in the time domain with the following associations: pump pump, Stokes signal, and Raman coherence idler. We derive analytical results for both the steady-state behavior and the time-dependent noise spectra, using standard linearization procedures. In the semiclassical limit, these results match with previous purely semiclassical treatments, which yield excellent agreement with experimental observations. The analytical time-dependent results predict perfect photon statistics conversion from the pump to the Stokes and nonclassical behavior under certain operational conditions.
Resumo:
The big proliferation of mobile communication systems has caused an increased concern about the interaction between the human body and the antennas of mobile handsets. In order to study the problem, a multiband antenna was designed, fabricated and measured to operate over two frequency sub bands 900 and 1800 MHz. After that, we simulated the same antenna, but now, in the presence of a human head model to analyze the head's influence. First, the influence of the human head on the radiation efficiency of the antenna has been investigated as a function of the distance between the head and the antenna and with the inclination of the antenna. Furthermore, the relative amount of the electromagnetic power absorbed in the head has been obtained. In this study the electromagnetic analysis has been performed via FDTD (Finite Difference Time Domain).
Resumo:
Neste trabalho é efectuado, não só o diagnóstico em regime permanente, mas também o estudo, simulação e análise do comportamento dinâmico da rede eléctrica da ilha de São Vicente em Cabo Verde. Os estudos de estabilidade transitória desempenham um importante papel, tanto no planeamento como na operação dos sistemas de potência. Tais estudos são realizados, em grande parte, através de simulação digital no domínio do tempo, utilizando integração numérica para resolver as equações não-lineares que modelam a dinâmica do sistema e dependem da existência de registos reais de perturbação (ex: osciloperturbografia). O objectivo do trabalho será também verificar a aplicabilidade dos requisitos técnicos que as unidades geradoras devem ter, no que concerne ao controlo de tensão, estabelecidos na futura regulamentação europeia desenvolvida pela ENTSO-E (European Network Transmission System Operator for Electricity). De entre os requisitos analisou-se a capacidade das máquinas existentes suportarem cavas de tensão decorrentes de curto-circuitos trifásicos simétricos, Fault Ride Through, no ponto de ligação à rede. Identificaram-se para o efeito os factores que influenciam a estabilidade desta rede, em regime perturbado nomeadamente: (i) duração do defeito, (ii) caracterização da carga, com e sem a presença do sistema de controlo de tensão (AVR) em unidades de geração síncronas. Na ausência de registos reais sobre o comportamento do sistema, conclui-se que este é sensível à elasticidade das cargas em particular do tipo potência constante, existindo risco de perda de estabilidade, neste caso, para defeitos superiores a 5ms sem AVR. A existência de AVR nesta rede afigura-se como indispensável para garantir estabilidade de tensão sendo contudo necessário proceder a uma correcta parametrização.
Resumo:
A oferta de serviços baseados em comunicações sem fios tem vindo a crescer exponencialmente na última década. Cada vez mais são exigidas maiores taxas de transmissão assim como uma melhor QoS, sem comprometer a potência de transmissão ou argura de banda disponível. A tecnologia MIMO consegue oferecer um aumento da capacidade destes sistemas sem requerer aumento da largura de banda ou da potência transmitida. O trabalho desenvolvido nesta dissertação consistiu no estudo dos sistemas MIMO, caracterizados pela utilização de múltiplas antenas para transmitir e receber a informação. Com um sistema deste tipo consegue-se obter um ganho de diversidade espacial utilizando códigos espaço-temporais, que exploram simultaneamente o domínio espacial e o domínio do tempo. Nesta dissertação é dado especial ênfase à codificação por blocos no espaço-tempo de Alamouti, a qual será implementada em FPGA, nomeadamente a parte de recepção. Esta implementação é efectuada para uma configuração de antenas 2x1, utilizando vírgula flutuante e para três tipos de modulação: BPSK, QPSK e 16-QAM. Por fim será analisada a relação entre a precisão alcançada na representação numérica dos resultados e os recursos consumidos pela FPGA. Com a arquitectura adoptada conseguem se obter taxas de transferência na ordem dos 29,141 Msimb/s (sem pipelines) a 262,674 Msimb/s (com pipelines), para a modulação BPSK.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Estruturas