993 resultados para Thoracic radiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliographies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Much of the material contained in this text has been presented as a series of articles ... in the North American veterinarian [beginning in 1937]"-Pref.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An X-ray visualization technique has been used for the quantitative determination of local liquid holdups distribution and liquid holdup hysteresis in a nonwetting two-dimensional (2-D) packed bed. A medical diagnostic X-ray unit has been used to image the local holdups in a 2-D cold model having a random packing of expanded polystyrene beads. An aqueous barium chloride solution was used as a fluid to achieve good contrast on X-ray images. To quantify the local liquid holdup, a simple calibration technique has been developed that can be used for most of the radiological methods such as gamma ray and neutron radiography. The global value of total liquid holdup, obtained by X-ray method, has been compared with two conventional methods: drainage and tracer response. The X-ray technique, after validation, has been used to visualize and quantify, the liquid hysteresis phenomena in a packed bed. The liquid flows in preferred paths or channels that carry droplets/rivulets of increasing size and number as the liquid flow rate is increased. When the flow is reduced, these paths are retained and the higher liquid holdup that persists in these regions leads to the holdup hysteresis effect. Holdup in some regions of the packed bed may be an order of magnitude higher than average at a particular flow rate. (c) 2005 American Institute of Chemical Engineers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design. Cross-sectional study. Objective. To develop a technique to measure electromyographic (EMG) activity of deep and superficial paraspinal muscles at different thoracic levels and to investigate activity of these muscles during seated trunk rotation. Summary of Background Data. Few studies have compared activity of deep and superficial paraspinal muscles of the thorax during trunk rotation, and conflicting results have been presented. Conflicting data may result from recording techniques or variation in activity between thoracic regions. Methods. EMG recordings were made from deep (multifidus/ rotatores) and superficial ( longissimus) paraspinal muscles at T5, T8, and T11 using selective intramuscular electrodes. Ten subjects rotated the trunk to end of range in each direction. EMG amplitude was measured in neutral, at end of range, and during four epochs, which represented four quarters of the movement. Results. During trunk rotation in sitting, longissimus EMG either increased with ipsilateral rotation ( T5) or decreased with contralateral rotation ( T5, T8, T11). In contrast, multifidus EMG was more variable and was either active with rotation in both directions ( particularly T5) or with one movement direction. Conclusions. The deep and superficial muscles of the thorax are differentially active, and the patterns of activity differ between the regions of the thorax. Data from this study support the hypothesis that multifidus may have a role in control of segmental motion at T5. Variability in multifidus activity at T8 and T11 suggests that this muscle may also control coupling between rotation and lateral flexion.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis reports on the development of a technique to evaluate hydraulic conductivities in a soil (Snowcal) subject to freezing conditions. The technique draws on three distinctly different disciplines, Nuclear Physics, Soil Physics and Remote Sensing to provide a non-destructive and reliable evaluation of hydraulic conductivity throughout a freezing test. Thermal neutron radiography is used to provide information on local water/ice contents at anytime throughout the test. The experimental test rig is designed so that the soil matrix can be radiated by a neutron beam, from a nuclear reactor, to obtain radiographs. The radiographs can then be interpreted, following a process of remote sensing image enhancement, to yield information on relative water/ice contents. Interpretation of the radiographs is accommodated using image analysis equipment capable of distinguishing between 256 shades of grey. Remote sensing image enhancing techniques are then employed to develop false colour images which show the movement of water and development of ice lenses in the soil. Instrumentation is incorporated in the soil in the form of psychrometer/thermocouples, to record water potential, electrical resistance probes to enable ice and water to be differentiated on the radiographs and thermocouples to record the temperature gradient. Water content determinations are made from the enhanced images and plotted against potential measurements to provide the moisture characteristic for the soil. With relevant mathematical theory pore water distributions are obtained and combined with water content data to give hydraulic conductivities. The values for hydraulic conductivity in the saturated soil and at the frozen fringe are compared with established values for silts and silty-sands. The values are in general agreement and, with refinement, this non-destructive technique could afford useful information on a whole range of soils. The technique is of value over other methods because ice lenses are actually seen forming in the soil, supporting the accepted theories of frost action. There are economic and experimental restraints to the work which are associated with the use of a nuclear facility, however, the technique is versatile and has been applied to the study of moisture transfer in porous building materials and could be further developed into other research areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cardiovascular health of the human population is a major concern for medical clinicians, with cardiovascular diseases responsible for 48% of all deaths worldwide, according to the World Health Organization. The development of new diagnostic tools that are practicable and economical to scrutinize the cardiovascular health of humans is a major driver for clinicians. We offer a new technique to obtain seismocardiographic signals up to 54 Hz covering both ballistocardiography (below 20 Hz) and audible heart sounds (20 Hz upward), using a system based on curvature sensors formed from fiber optic long period gratings. This system can visualize the real-time three-dimensional (3-D) mechanical motion of the heart by using the data from the sensing array in conjunction with a bespoke 3-D shape reconstruction algorithm. Visualization is demonstrated by adhering three to four sensors on the outside of the thorax and in close proximity to the apex of the heart; the sensing scheme revealed a complex motion of the heart wall next to the apex region of the heart. The detection scheme is low-cost, portable, easily operated and has the potential for ambulatory applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the predictive merits of selected cognitive and noncognitive variables on the national Registry exam pass rate using 2008 graduates (n = 175) from community college radiography programs in Florida. The independent variables included two GPAs, final grades in five radiography courses, self-efficacy, and social support. The dependent variable was the first-attempt results on the national Registry exam. The design was a retrospective predictive study that relied on academic data collected from participants using the self-report method and on perceptions of students' success on the national Registry exam collected through a questionnaire developed and piloted in the study. All independent variables except self-efficacy and social support correlated with success on the national Registry exam ( p < .01) using the Pearson Product-Moment Correlation analysis. The strongest predictor of the national Registry exam success was the end-of-program GPA, r = .550, p < .001. The GPAs and scores for self-efficacy and social support were entered into a logistic regression analysis to produce a prediction model. The end-of-program GPA (p = .015) emerged as a significant variable. This model predicted 44% of the students who failed the national Registry exam and 97.3% of those who passed, explaining 45.8% of the variance. A second model included the final grades for the radiography courses, self efficacy, and social support. Three courses significantly predicted national Registry exam success; Radiographic Exposures, p < .001; Radiologic Physics, p = .014; and Radiation Safety & Protection, p = .044, explaining 56.8% of the variance. This model predicted 64% of the students who failed the national Registry exam and 96% of those who passed. The findings support the use of in-program data as accurate predictors of success on the national Registry exam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Patients with lung and esophageal cancer often have surgery as a means of treatment. In Newfoundland and Labrador, patients with lung and esophageal issues are cared for on Six East, the General/Thoracic Surgery unit at St. Clare’s Mercy Hospital. These patients frequently require chest tubes, which are managed and assessed by Registered Nurses (RNs) on the unit. For nurses new to thoracic surgery, fulfilling their new role and caring for chest tube systems can be daunting. Purpose: The purpose of this practicum project was to develop a learning resource manual for nurses who are new to thoracic surgery. Via self-directed learning, the manual can increase the knowledge and self-efficacy of nurses who are caring for thoracic surgery clients and assessing chest tube systems. Methods: An informal needs assessment, integrated literature review, and several consultations via in-person interviews were conducted. Results: Based on the findings from these methodologies, Knowles’ Adult Learning Theory, and Benner’s Novice to Expert Model, a learning resource manual was created. The manual was divided into chapters covering various aspects of patient and chest tube system care and assessment. Conclusion: For the purpose of this practicum project, no evaluation was conducted. However, a plan for future evaluation of the learning resource manual has been developed to determine if the manual assisted with increasing the knowledge and self-efficacy of nurses new to thoracic surgery. “Test Your Knowledge” questions were included at the end of each chapter in the manual as well as case study scenarios to allow for participant self-evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.