880 resultados para Speed limits.
Resumo:
This paper proposes a very simple method for increasing the algorithm speed for separating sources from PNL mixtures or invertingWiener systems. The method is based on a pertinent initialization of the inverse system, whose computational cost is very low. The nonlinear part is roughly approximated by pushing the observations to be Gaussian; this method provides a surprisingly good approximation even when the basic assumption is not fully satisfied. The linear part is initialized so that outputs are decorrelated. Experiments shows the impressive speed improvement.
Resumo:
The GH-2000 and GH-2004 projects have developed a method for detecting GH misuse based on measuring insulin-like growth factor-I (IGF-I) and the amino-terminal pro-peptide of type III collagen (P-III-NP). The objectives were to analyze more samples from elite athletes to improve the reliability of the decision limit estimates, to evaluate whether the existing decision limits needed revision, and to validate further non-radioisotopic assays for these markers. The study included 998 male and 931 female elite athletes. Blood samples were collected according to World Anti-Doping Agency (WADA) guidelines at various sporting events including the 2011 International Association of Athletics Federations (IAAF) World Athletics Championships in Daegu, South Korea. IGF-I was measured by the Immunotech A15729 IGF-I IRMA, the Immunodiagnostic Systems iSYS IGF-I assay and a recently developed mass spectrometry (LC-MS/MS) method. P-III-NP was measured by the Cisbio RIA-gnost P-III-P, Orion UniQ? PIIINP RIA and Siemens ADVIA Centaur P-III-NP assays. The GH-2000 score decision limits were developed using existing statistical techniques. Decision limits were determined using a specificity of 99.99% and an allowance for uncertainty because of the finite sample size. The revised Immunotech IGF-I - Orion P-III-NP assay combination decision limit did not change significantly following the addition of the new samples. The new decision limits are applied to currently available non-radioisotopic assays to measure IGF-I and P-III-NP in elite athletes, which should allow wider flexibility to implement the GH-2000 marker test for GH misuse while providing some resilience against manufacturer withdrawal or change of assays. Copyright © 2015 John Wiley & Sons, Ltd.
Resumo:
A method for the analysis of high-speed solid-rotor induction motors in presented. The analysis is based on a new combination of the three dimensional linear method and the transfer matrix method. Both saturation and finite length effects are taken into account. The active region of the solid rotor is divided into saturated and unsaturated parts. The time dependence is assumed to be sinusoidal and phasor quantities are used in the solution. The method is applied to the calculation of smooth solid rotors manufactured of different materials. Six rotor materials are tested: three construction steels, pure iron, a cobaltiron alloy and an aluminium alloy. The results obtained by the method agree fairly well with the measurement quantities.
Resumo:
In order to better understand the specificity of training adaptations, we compared the effects of two different anaerobic training regimes on various types of soccer-related exercise performances. During the last 3 weeks of the competitive season, thirteen young male professional soccer players (age 18.5±1 yr, height 179.5±6.5 cm, body mass 74.3±6.5 kg) reduced the training volume by ~20% and replaced their habitual fitness conditioning work with either speed endurance production (SEP; n = 6) or speed endurance maintenance (SEM; n = 7) training, three times per wk. SEP training consisted of 6-8 reps of 20-s all-out running bouts followed by 2 min of passive recovery, whereas SEM training was characterized by 6-8 x 20-s all-out efforts interspersed with 40 s of passive recovery. SEP training reduced (p<0.01) the total time in a repeated sprint ability test (RSAt) by 2.5%. SEM training improved the 200-m sprint performance (from 26.59±0.70 to 26.02±0.62 s, p<0.01) and had a likely beneficial impact on the percentage decrement score of the RSA test (from 4.07±1.28 to 3.55±1.01%) but induced a very likely impairment in RSAt (from 83.81±2.37 to 84.65±2.27 s). The distance covered in the Yo-Yo Intermittent Recovery test level 2 was 10.1% (p<0.001) and 3.8% (p<0.05) higher after SEP and SEM training, respectively, with possibly greater improvements following SEP compared to SEM. No differences were observed in the 20- and 40-m sprint performances. In conclusion, these two training strategies target different determinants of soccer-related physical performance. SEP improved repeated sprint and high-intensity intermittent exercise performance, whereas SEM increased muscles' ability to maximize fatigue tolerance and maintain speed development during both repeated all-out and continuous short-duration maximal exercises. These results provide new insight into the precise nature of a stimulus necessary to improve specific types of athletic performance in trained young soccer players.
Resumo:
Tässä työssä optimoidaan keskinopean Wärtsilä 32 -dieselmoottorin jäähdytysjärjestelmää ja tutkitaan taajuusmuuttajien käyttömahdollisuutta kiertopumppujen yhteydessä niin, että järjestelmässä saataisiin kiertämään vain kulloinkin tarvittava määrä vettä. Tutkimuksen mallinnus on toteutettu laatimalla aiemmin käytössä olleista yksinkertaisista simulointimalleista yksi malli, johon on sisällytetty sekä virtauksen että lämmönsiirron laskenta, jotka on aiemmin mallinnettu erillisillä ohjelmilla. Diplomityö on osa projektia, joka on tehty Sähkötekniikan osaston tutkijan Mikko Pääkkösen kanssa yhteistyössä. Tämän diplomityö keskittyy lähinnä virtausteknisiin ja lämmönsiirtoon liittyviin asioihin, kun taas sähkötekniikan osuus on esitetty Mikko Pääkkösen raportissa. Tulosten perustella voidaan sanoa, että taajuusmuuttajakäyttö kannattaa kiertopumppujen yhteydessä. Käyttämällä pumppujen virtaussäätöä voidaan jäähdytysjärjestelmästä jättää monia komponentteja, kuten termostaattiventtiilejä pois. Mallinnetut yksinkertaiset piiriratkaisut näyttävät toimivan ainakin yleisellä tasolla. Tutkimusta pumppujen säädöstä ja tässä projektissa luoduista jäähdytysjärjestelmäkonfiguraatioista kannattaa jatkaa.
Resumo:
Within the latest decade high-speed motor technology has been increasingly commonly applied within the range of medium and large power. More particularly, applications like such involved with gas movement and compression seem to be the most important area in which high-speed machines are used. In manufacturing the induction motor rotor core of one single piece of steel it is possible to achieve an extremely rigid rotor construction for the high-speed motor. In a mechanical sense, the solid rotor may be the best possible rotor construction. Unfortunately, the electromagnetic properties of a solid rotor are poorer than the properties of the traditional laminated rotor of an induction motor. This thesis analyses methods for improving the electromagnetic properties of a solid-rotor induction machine. The slip of the solid rotor is reduced notably if the solid rotor is axially slitted. The slitting patterns of the solid rotor are examined. It is shown how the slitting parameters affect the produced torque. Methods for decreasing the harmonic eddy currents on the surface of the rotor are also examined. The motivation for this is to improve the efficiency of the motor to reach the efficiency standard of a laminated rotor induction motor. To carry out these research tasks the finite element analysis is used. An analytical calculation of solid rotors based on the multi-layer transfer-matrix method is developed especially for the calculation of axially slitted solid rotors equipped with wellconducting end rings. The calculation results are verified by using the finite element analysis and laboratory measurements. The prototype motors of 250 – 300 kW and 140 Hz were tested to verify the results. Utilization factor data are given for several other prototypes the largest of which delivers 1000 kW at 12000 min-1.
Resumo:
PURPOSE: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. METHODS: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. RESULTS: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25-30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. CONCLUSIONS: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.
Resumo:
This study aimed to examine developmental trends in response inhibition during childhood and to control for possible developmental influence of other basic cognitive processes (such as working memory and processing speed). In addition, we explored the relationships between response inhibition, working memory, and processing speed, as they are thought to be integral to cognitive control. Therefore, we assessed these three cognitive abilities in 159 children aged from 5 to 12. Results showed an improvement in response inhibition ability from 5 to 10 years of age. This improvement remained significant after controlling for the influence of working memory and processing speed. Furthermore, the developmental relationships showed an early differentiation between response inhibition, working memory, and processing speed. Thus, these processes were independent and need to be treated as such in further studies.
Resumo:
As the world’s energy demand is increasing, a durable solution to control it is to improve the energy efficiency of the processes. It has been estimated that pumping applications have a significant potential for energy savings trough equipment or control system changes. For many pumping application the use of a variable speed drive as a process control element is the most energy efficient solution. The main target of this study is to examine the energy efficiency of a drive system that moves the pump. In a larger scale the purpose of this study is to examine how the different manufacturers’ variable speed drives are functioning as a control device of a pumping process. The idea is to compare the drives from a normal pump user’s point of view. The things that are mattering for the pump user are the efficiency gained in the process and the easiness of the use of the VSD. So some thought is given also on valuating the user-friendliness of the VSDs. The VSDs are compared to each other also on the basis of their life cycle energy costs in different kind of pumping cases. The comparison is made between ACS800 from ABB, VLT AQUA Drive from Danfoss, NX-drive from Vacon and Micromaster 430 from Siemens. The efficiencies are measured in power electronics laboratory in the Lappeenranta University of Technology with a system that consists of a variable speed drive, an induction motor with dc-machine, two power analyzers and a torque transducer. The efficiencies are measured as a function of a load at different frequencies. According to measurement results the differences between the measured system efficiencies on the actual working area of pumping are on average few percent units. When examining efficiencies at the whole range of different loads and frequencies, the differences get bigger. At low frequencies and loads the differences between the most efficient and the least efficient systems are at the most about ten percent units. At the most of the tested points ABB’s drive seem to have slightly better efficiencies than the other drives.
Resumo:
BACKGROUND: Habitual walking speed predicts many clinical conditions later in life, but it declines with age. However, which particular exercise intervention can minimize the age-related gait speed loss is unclear. PURPOSE: Our objective was to determine the effects of strength, power, coordination, and multimodal exercise training on healthy old adults' habitual and fast gait speed. METHODS: We performed a computerized systematic literature search in PubMed and Web of Knowledge from January 1984 up to December 2014. Search terms included 'Resistance training', 'power training', 'coordination training', 'multimodal training', and 'gait speed (outcome term). Inclusion criteria were articles available in full text, publication period over past 30 years, human species, journal articles, clinical trials, randomized controlled trials, English as publication language, and subject age ≥65 years. The methodological quality of all eligible intervention studies was assessed using the Physiotherapy Evidence Database (PEDro) scale. We computed weighted average standardized mean differences of the intervention-induced adaptations in gait speed using a random-effects model and tested for overall and individual intervention effects relative to no-exercise controls. RESULTS: A total of 42 studies (mean PEDro score of 5.0 ± 1.2) were included in the analyses (2495 healthy old adults; age 74.2 years [64.4-82.7]; body mass 69.9 ± 4.9 kg, height 1.64 ± 0.05 m, body mass index 26.4 ± 1.9 kg/m(2), and gait speed 1.22 ± 0.18 m/s). The search identified only one power training study, therefore the subsequent analyses focused only on the effects of resistance, coordination, and multimodal training on gait speed. The three types of intervention improved gait speed in the three experimental groups combined (n = 1297) by 0.10 m/s (±0.12) or 8.4 % (±9.7), with a large effect size (ES) of 0.84. Resistance (24 studies; n = 613; 0.11 m/s; 9.3 %; ES: 0.84), coordination (eight studies, n = 198; 0.09 m/s; 7.6 %; ES: 0.76), and multimodal training (19 studies; n = 486; 0.09 m/s; 8.4 %, ES: 0.86) increased gait speed statistically and similarly. CONCLUSIONS: Commonly used exercise interventions can functionally and clinically increase habitual and fast gait speed and help slow the loss of gait speed or delay its onset.
Resumo:
This thesis presents briefly the basic operation and use of centrifugal pumps and parallel pumping applications. The characteristics of parallel pumping applications are compared to circuitry, in order to search analogy between these technical fields. The purpose of studying circuitry is to find out if common software tools for solving circuit performance could be used to observe parallel pumping applications. The empirical part of the thesis introduces a simulation environment for parallel pumping systems, which is based on circuit components of Matlab Simulink —software. The created simulation environment ensures the observation of variable speed controlled parallel pumping systems in case of different controlling methods. The introduced simulation environment was evaluated by building a simulation model for actual parallel pumping system at Lappeenranta University of Technology. The simulated performance of the parallel pumps was compared to measured values of the actual system. The gathered information shows, that if the initial data of the system and pump perfonnance is adequate, the circuitry based simulation environment can be exploited to observe parallel pumping systems. The introduced simulation environment can represent the actual operation of parallel pumps in reasonably accuracy. There by the circuitry based simulation can be used as a researching tool to develop new controlling ways for parallel pumps.
Resumo:
In April 2009, the US government unveiled its blueprint for a national network of high-speed passenger rail (HSR) lines aimed at reducing traffic congestion, cutting national dependence on foreign oil and improving rural and urban environments. In implementing such a program, it is essential to identify the factors that might influence decision making and the eventual success of the HSR project, as well as foreseeing the obstacles that will have to be overcome.
Resumo:
The growing use of direct oral anticoagulants, in particular among older subjects, raises questions about the limits of the evidence-based medicine. The phase III studies that have validated the efficacy and the safety profile of these molecules (dabigatran, rivaroxaban, apixaban, edoxaban) in their both indications, the venous thromboembolic disease and the non-valvular atrial fibrillation raise concerns in four major fields: the financial support of pharmaceutical companies, the links of interest for many authors with the industry, the study design (exclusively non-inferiority studies), and the poor representativeness of the older subjects included. All these points are discussed, using data of sub-groups studies, post-marketing studies and recent meta-analysis. The lack of data for the very old subjects, with frailty or comorbidities, remains the main concern from these phase III studies.
Resumo:
The present work describes the development of a fast and robust analytical method for the determination of 53 antibiotic residues, covering various chemical groups and some of their metabolites, in environmental matrices that are considered important sources of antibiotic pollution, namely hospital and urban wastewaters, as well as in river waters. The method is based on automated off-line solid phase extraction (SPE) followed by ultra-high-performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry (UHPLC–QqLIT). For unequivocal identification and confirmation, and in order to fulfill EU guidelines, two selected reaction monitoring (SRM) transitions per compound are monitored (the most intense one is used for quantification and the second one for confirmation). Quantification of target antibiotics is performed by the internal standard approach, using one isotopically labeled compound for each chemical group, in order to correct matrix effects. The main advantages of the method are automation and speed-up of sample preparation, by the reduction of extraction volumes for all matrices, the fast separation of a wide spectrum of antibiotics by using ultra-high-performance liquid chromatography, its sensitivity (limits of detection in the low ng/L range) and selectivity (due to the use of tandem mass spectrometry) The inclusion of β-lactam antibiotics (penicillins and cephalosporins), which are compounds difficult to analyze in multi-residue methods due to their instability in water matrices, and some antibiotics metabolites are other important benefits of the method developed. As part of the validation procedure, the method developed was applied to the analysis of antibiotics residues in hospital, urban influent and effluent wastewaters as well as in river water samples
Indications et limites de la thoracoscopie en 1994. [Indications and limits of thracoscopy in 1994.]
Resumo:
Reléguée au rang de moyen diagnostique occasionnel avec l'avènement de la streptomycine dès 1945, la thoracoscopie a repris depuis trois à cinq ans un rôle prépondérant dans l'armement du chirurgien thoracique, comme moyen diagnostique et surtout comme outil thérapeutique. Dans cet article, nous faisons le point quant à la place actuelle de la thoracoscopie face aux différentes pathologies thoraciques, pulmonaires, médiastinales et oesophagiennes. Dans certaines indications (pneumothorax, infiltrats pulmonaires diffus, nodule pulmonaire isolé), cette technique en pleine expansion a déjà clairement démontré sa supériorité. Dans d'autres cas, en particulier dans les affections néoplasiques, son application est encore le sujet de controverses.