931 resultados para Reference configuration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

One aim of this study is to determine the impact of water velocity on the uptake of indicator polychlorinated biphenyls (iPCBs) by silicone rubber (SR) and low-density polyethylene (LDPE) passive samplers. A second aim is to assess the efficiency of performance reference compounds (PRCs) to correct for the impact of water velocity. SR and LDPE samplers were spiked with 11 or 12 PRCs and exposed for 6 weeks to four different velocities (in the range of 1.6 to 37.7 cm s−1) in river-like flow conditions using a channel system supplied with river water. A relationship between velocity and the uptakewas found for each iPCB and enables to determine expected changes in the uptake due to velocity variations. For both samplers, velocity increases from 2 to 10 cm s−1, 30 cm s−1 (interpolated data) and 100 cm s−1 (extrapolated data) lead to increases of the uptake which do not exceed a factor of 2, 3 and 4.5, respectively. Results also showed that the influence of velocity decreased with increasing the octanol-water coefficient partition (log Kow) of iPCBs when SR is used whereas the opposite effect was observed for LDPE. Time-weighted average (TWA) concentrations of iPCBs in water were calculated from iPCB uptake and PRC release. These calculations were performed using either a single PRC or all the PRCs. The efficiency of PRCs to correct the impact of velocity was assessed by comparing the TWA concentrations obtained at the four tested velocities. For SR, a good agreement was found among the four TWA concentrations with both methods (average RSD b 10%). Also for LDPE, PRCs offered a good correction of the impact of water velocity (average RSD of about 10 to 20%). These results contribute to the process of acceptance of passive sampling in routine regulatory monitoring programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reference collections of multiple Drosophila lines with accumulating collections of "omics" data have proven especially valuable for the study of population genetics and complex trait genetics. Here we present a description of a resource collection of 84 strains of Drosophila melanogaster whose genome sequences were obtained after 12 generations of full-sib inbreeding. The initial rationale for this resource was to foster development of a systems biology platform for modeling metabolic regulation by the use of natural polymorphisms as perturbations. As reference lines, they are amenable to repeated phenotypic measurements, and already a large collection of metabolic traits have been assayed. Another key feature of these strains is their widespread geographic origin, coming from Beijing, Ithaca, Netherlands, Tasmania, and Zimbabwe. After obtaining 12.5× coverage of paired-end Illumina sequence reads, SNP and indel calls were made with the GATK platform. Thorough quality control was enabled by deep sequencing one line to >100×, and single-nucleotide polymorphisms and indels were validated using ddRAD-sequencing as an orthogonal platform. In addition, a series of preliminary population genetic tests were performed with these single-nucleotide polymorphism data for assessment of data quality. We found 83 segregating inversions among the lines, and as expected these were especially abundant in the African sample. We anticipate that this will make a useful addition to the set of reference D. melanogaster strains, thanks to its geographic structuring and unusually high level of genetic diversity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Valtion rajat ylittävät terveyspalvelut Euroopan unionissa sekä Euroopan unionin säädösten merkitys ja vaikutus erityisesti lääkejakeluun ja verenluovuttajille jaettavaan tiedotusaineistoon Valtion rajat ylittävä terveydenhuolto on suuren kiinnostuksen kohteena Euroopan unionissa. Resurssien hyödyntäminen parhaalla mahdollisella tavalla ja tiedon keskittäminen ovat tarpeen terveydenhuollon kustannusten alati noustessa. Terveydenhuoltopalvelut kuuluvat Euroopan sisämarkkinoiden vapaan liikkuvuuden piiriin. Euroopan unionilla ei ole kuitenkaan toimivaltaa säädellä terveydenhuoltojärjestelmiä, vaan sen mahdollisuudet ovat enimmäkseen kansanterveyden edistämisessä ja suojelussa, myös muilla toimialueilla kuin terveydenhuollossa. Tutkimuksen tavoitteena oli tutkia Euroopan unionin säädösten vaikutusta terveydenhuoltosektoriin, erityisesti valtion rajat ylittäviin terveydenhuoltopalveluihin. Erityiskohteena olivat lääkemääräyksen toimittaminen toisen Euroopan unionin jäsenmaan apteekista, resepti-lääkkeiden maahantuonti omaan henkilökohtaiseen käyttöön, sähköisen lääkemääräyksen käyttö kansallisesti ja mahdollisuudet sen käyttöön eri jäsenmaiden välillä, online-apteekkien soveltuvuus Euroopan unionin sisämarkkinoille sekä verenluovuttajille jaettavan tiedotusaineiston yhtenäistämistarve Euroopan unionin alueella. Tutkimuksen osa-alueiden aineisto koottiin vuosina 1999–2003, jolloin Euroopan unioniin kuului 15 jäsenmaata. Apteekit toimittivat useimmiten myös ei-kansalliset, toisessa Euroopan unionin jäsenmaassa annetut lääkemääräykset. Kaikki jäsenmaat rajoittivat lääkemääräyksen vaativien lääkkeiden maahantuontia. Rajoituksia oli maahantuontimäärissä ja -tavoissa. Lisäksi sairasvakuutuskorvausten saaminen ulkomailla lunastetuista reseptilääkkeistä oli hankalaa. Sähköiset lääkemääräykset olivat käytössä vain kahdessa maassa, mutta useissa maissa suunniteltiin niiden kokeilua. Standardit ja käyttöjärjestelmät olivat erilaisia eri maissa. Euroopan unionin alueelle on perustettu online-apteekkeja, joiden toiminta on kuitenkin vaatimatonta. Verenluovuttajille annettava tiedotusaineisto ei missään maassa täyttänyt veridirektiivin vaatimuksia. Tutkimuksen tulokset osoittivat kansallisten käytäntöjen eroavaisuuksien rajoittavan valtion rajat ylittäviä terveydenhuoltopalveluita. Vaikka Euroopan unionin tavoitteena ei ole yhtenäistää terveydenhuoltojärjestelmiä, on tarpeen arvioida uudelleen unionin ja jäsenmaiden välistä työnjakoa. Kansalliset terveydenhuoltojärjestelmät eivät ole erillään Euroopan sisämarkkinoista, jotka merkittävästi vaikuttavat terveydenhuoltoon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Next-generation sequencing (NGS) technologies have become the standard for data generation in studies of population genomics, as the 1000 Genomes Project (1000G). However, these techniques are known to be problematic when applied to highly polymorphic genomic regions, such as the human leukocyte antigen (HLA) genes. Because accurate genotype calls and allele frequency estimations are crucial to population genomics analyses, it is important to assess the reliability of NGS data. Here, we evaluate the reliability of genotype calls and allele frequency estimates of the single-nucleotide polymorphisms (SNPs) reported by 1000G (phase I) at five HLA genes (HLA-A, -B, -C, -DRB1, and -DQB1). We take advantage of the availability of HLA Sanger sequencing of 930 of the 1092 1000G samples and use this as a gold standard to benchmark the 1000G data. We document that 18.6% of SNP genotype calls in HLA genes are incorrect and that allele frequencies are estimated with an error greater than ±0.1 at approximately 25% of the SNPs in HLA genes. We found a bias toward overestimation of reference allele frequency for the 1000G data, indicating mapping bias is an important cause of error in frequency estimation in this dataset. We provide a list of sites that have poor allele frequency estimates and discuss the outcomes of including those sites in different kinds of analyses. Because the HLA region is the most polymorphic in the human genome, our results provide insights into the challenges of using of NGS data at other genomic regions of high diversity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Niemann-Pick type C (NP-C) is a rare progressive neurodegenerative lipid storage disorder with heterogeneous clinical presentation and challenging diagnostic procedures. Recently oxysterols have been reported to be specific biomarkers for NP-C but knowledge on the intra-individual variation and on reference intervals in children and adolescents are lacking. METHODS: We established a LC-MS/MS assay to measure Cholestane-3β, 5α, 6β-triol (C-triol) and 7-Ketocholesterol (7-KC) following Steglich esterification. To assess reference intervals and intra-individual variation we determined oxysterols in 148 children and adolescents from 0 to 18 years and repeat measurements in 19 of them. RESULTS: The reported method is linear (r>0.99), sensitive (detection limit of 0.03 ng/mL [0.07 nM] for C-triol, and 0.54 ng/mL [1.35 nM] for 7-KC) and precise, with an intra-day imprecision of 4.8% and 4.1%, and an inter-day imprecision of 7.0% and 11.0% for C-triol (28 ng/ml, 67 nM) and 7-KC (32 ng/ml, 80 nM), respectively. Recoveries for 7-KC and C-triol range between 93% and 107%. The upper reference limit obtained for C-triol is 40.4 ng/mL (95% CI: 26.4-61.7 ng/mL, 96.0 nM, 95% CI: 62.8-146.7 nM) and 75.0 ng/mL for 7-KC (95% CI: 55.5-102.5 ng/mL, 187.2 nM, 95% CI: 138.53-255.8 nM), with no age or gender dependency. Both oxysterols have a broad intra-individual variation of 46%±23% for C-triol and 52%±29% for 7-KC. Nevertheless, all Niemann-Pick patients showed increased C-triol levels including Niemann-Pick type A and B patients. CONCLUSIONS: The LC-MS/MS assay is a robust assay to quantify C-triol and 7-KC in plasma with well documented reference intervals in children and adolescents to screen for NP-C in the pediatric population. In addition our results suggest that especially the C-triol is a biomarker for all three Niemann-Pick diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The University of Barcelona is developing a pilot-scale hot wire chemical vapor deposition (HW-CVD) set up for the deposition of nano-crystalline silicon (nc-Si:H) on 10 cm × 10 cm glass substrate at high deposition rate. The system manages 12 thin wires of 0.15-0.2 mm diameter in a very dense configuration. This permits depositing very uniform films, with inhomogeneities lower than 2.5%, at high deposition rate (1.5-3 nm/s), and maintaining the substrate temperature relatively low (250 °C). The wire configuration design, based on radicals' diffusion simulation, is exposed and the predicted homogeneity is validated with optical transmission scanning measurements of the deposited samples. Different deposition series were carried out by varying the substrate temperature, the silane to hydrogen dilution and the deposition pressure. By means of Fourier transform infrared spectroscopy (FTIR), the evolution in time of the nc-Si:H vibrational modes was monitored. Particular importance has been given to the study of the material stability against post-deposition oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an evaluation framework that allows a standardized and quantitative comparison of IVUS lumen and media segmentation algorithms. This framework has been introduced at the MICCAI 2011 Computing and Visualization for (Intra)Vascular Imaging (CVII) workshop, comparing the results of eight teams that participated. We describe the available data-base comprising of multi-center, multi-vendor and multi-frequency IVUS datasets, their acquisition, the creation of the reference standard and the evaluation measures. The approaches address segmentation of the lumen, the media, or both borders; semi- or fully-automatic operation; and 2-D vs. 3-D methodology. Three performance measures for quantitative analysis have been proposed. The results of the evaluation indicate that segmentation of the vessel lumen and media is possible with an accuracy that is comparable to manual annotation when semi-automatic methods are used, as well as encouraging results can be obtained also in case of fully-automatic segmentation. The analysis performed in this paper also highlights the challenges in IVUS segmentation that remains to be solved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Radial maze tasks have been used to assess optimal foraging and spatial abilities in rodents. The spatial performance was based on a capacity to rely on a configuration of local and distant cues. We adapted maze procedures assessing the relative weight of local cues and distant landmarks for arm choice in humans. NEW METHOD: The procedure allowed testing memory of places in four experimental setups: a fingertip texture-groove maze, a tactile screen maze, a virtual radial maze and a walking size maze. During training, the four reinforced positions remained fixed relative to local and distal cues. During subsequent conflict trials, these frameworks were made conflictive in the prediction of reward locations. RESULTS: Three experiments showed that the relative weight of local and distal relational cues is affected by different factors such as cues' nature, visual access to the environment, real vs. virtual environment, and gender. A fourth experiment illustrated how a walking maze can be used with people suffering intellectual disability. COMPARISON WITH EXISTING METHODS: In our procedure, long-term (reference) and short-term (working) memory can be assessed. It is the first radial task adapted to human that enables dissociating local and distal cues, to provides an indication as to their relative salience. Our mazes are moveable and easily used in limited spaces. Tasks are performed with realistic and spontaneous though controlled exploratory movements. CONCLUSION: Our tasks enabled highlighting the use of different strategies. In a clinical perspective, considering the use of compensatory strategies should orient towards adapted behavioural rehabilitation.