996 resultados para Rate of change


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We analyze the role played by system-environment correlations in the emergence of non-Markovian dynamics. By working within the framework developed in Breuer et al. [Phys. Rev. Lett. 103, 210401 (2009)], we unveil a fundamental connection between non-Markovian behavior and dynamics of system-environment correlations. We derive an upper bound to the rate of change of the distinguishability between different states of the system that explicitly depends on the establishment of correlations between system and environment. We illustrate our results using a fully solvable spin-chain model, which allows us to gain insight into the mechanisms triggering non-Markovian evolution. © 2012 American Physical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study presents the use of periodic arrays of freestanding slot frequency-selective screens (FSS) as a means for generating circularly polarised signals from an incident linearly polarised signal at normal incidence to the structure. Measured and simulated results for crossed, linear and various ring slot element shapes in single and double-layer polarisation convertor structures are presented for 10 GHz operation. It is shown that 3 dB axial ratio (AR) bandwidths of 21% can be achieved with the one-layer perforated screen design and that the rate of change is lower than the double-layer structures. An insertion loss of 0.34 dB can be achieved for the split circular ring double-layer periodic array, and of the three topologies presented the hexagonal split-ring polarisation convertor gives the lowest variation of AR with angle of incidence 1.8 dB/45° and 3.6 dB/45° for the single and double-screen FSS, respectively. In addition, their tolerance to angle of incidence variation is presented. The capability of the surfaces reported here as twist polariser or spatial isolator components has been demonstrated with up to -30 dB isolation between incident and re-reflected signals for the double-layer designs being measured. © 2010 The Institution of Engineering and Technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The outcomes of school-based counseling incorporating the Partners for Change Outcome Monitoring System (PCOMS) were evaluated using a cohort design, with multilevel modeling to identify predictors of change. Participants were 288 7-11 year olds experiencing social, emotional or behavioral difficulties. The intervention was associated with significant reductions in psychological distress, with a pre-post effect size (d) of 1.49 on the primary outcome measure and 88.7% clinical improvement. Greater improvements were found for disabled children, older children, and where CBT methods were used. The findings provide support for the use of systematic feedback in therapy with children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces some novel upper and lower bounds on the achievable sum rate of multiple-input multiple-output (MIMO) systems with zero-forcing (ZF) receivers. The presented bounds are not only tractable but also generic since they apply for different fading models of interest, such as uncorrelated/ correlated Rayleigh fading and Ricean fading. We further formulate a new relationship between the sum rate and the first negative moment of the unordered eigenvalue of the instantaneous correlation matrix. The derived expressions are explicitly compared with some existing results on MIMO systems operating with optimal and minimum mean-squared error (MMSE) receivers. Based on our analytical results, we gain valuable insights into the implications of the model parameters, such as the number of antennas, spatial correlation and Ricean-K factor, on the sum rate of MIMO ZF receivers. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper considers the enhancement of loss-of-mains detection by use of a differential rate-of-change-of-frequency relay to reduce nuisance tripping and improve sensitivity to small excursions in frequency. The telecommunications media which might carry the differential ROCOF signal are reviewed with a focus on channel latency, bandwidth and security.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Cataract extraction is the most commonly performed surgery in the National Health Service. Myopia increases the risk of postoperative rhegmatogenous retinal detachment (RRD). The aim of this study was to determine the incidence and rate of RRD seven years after cataract extraction in highly myopic eyes. Methods: Retrospective review was performed of notes of all high myopes (axial length 26.0 mm or more) who underwent cataract extraction during the study period in one centre. Results: 84 eyes met the study criteria. Follow-up time from surgery was 93 to 147 months (median 127 months). The average axial length was 28.72 mm (sd 1.37). Two eyes developed post-operative RRD; the incidence was 2.4% and the rate one RRD per 441.6 person-years. The results of 15 other studies on the incidence of RRD after cataract extraction in high myopia were pooled and combined with our estimate. Conclusion: Both patients in our study who developed RRD had risk factors for this complication as well as high myopia. Risk factors are discussed in the light of our results and the pooled estimate. Our follow-up time is longer than most. Future case series should calculate rates to allow meaningful comparison of case series. © The Ulster Medical Society, 2009.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This letter investigates performance enhancement by the concept of multi-carrier index keying in orthogonal frequency division multiplexing (OFDM) systems. For the performance evaluation, a tight closed-form approximation of the bit error rate (BER) is derived introducing the expression for the number of bit errors occurring in both the index domain and the complex domain, in the presence of both imperfect and perfect detection of active multi-carrier indices. The accuracy of the derived BER results for various cases are validated using simulations, which can provide accuracy within 1 dB at favorable channels.