Human Fertility 17(3):165-9 This article describes the experiences of twelve Irish couples who had successful IVF treatment in Ireland. Irish Medical guidelines specify that IVF may only be used when no other treatment is likely to be effective. This article is based on data drawn from a longitudinal research study by Cotter (2009) which tells the stories of 34 couples who sought fertility treatment. Initially, the women assumed that they would become pregnant when they stopped using contraception. As a couple, it was the ‘right time’ for them to have a child - they were ready, socially and financially. For several months they were patient, hoping it would happen naturally. With envy and some despair they watched as their friends had babies. Infertility came as a shock to most of them. They were reluctant to talk about it to anyone, and over time their anxieties were accompanied by feelings of regret, stigma and social exclusion. They finally sought medical treatment. The latter involved a series of diagnostic treatments, which eventually culminated in IVF which offered them a final chance of having a ‘child of their own’. While IVF can be clinically assessed in terms of cycle success rates, their stories showed treatment as a series of discoveries, as an extensive range of diagnostic tests and procedures helped to reveal to them where their problems might lie. They described their treatments as a series of sequential ‘hurdles’ that they had to overcome, which further strengthened their resolve to try IVF. Much more knowledgeable at that stage, they embraced IVF as a final challenge with single minded dedication while drawing on all their psychological and biological resources to promote a successful outcome. Of the 34 couples who took part in the study, twelve got pregnant. Unfortunately, two children died shortly after birth but eighteen babies survived (see Table I). The findings suggest that health policy should raise awareness of infertility, and advise women to become aware of it just as in the past, when health policy addressed contraception. Increased public knowledge would reduce the stigma attached to the inability to have a baby. In the Irish case, infertility diagnosis should be reviewed with a view to giving eligible couples earlier access to IVF.  

Relevância:

80.00% 80.00%

Publicador:

Resumo:

L’ipertiroidismo felino rappresenta oggi la più comune endocrinopatia della specie. I capitoli 2 e 3 costituiscono una revisione della letteratura in merito agli aspetti clinici, diagnostici e terapeutici della patologia. Il capitolo 4 indaga il ruolo della dimetilarginina simmetrica (SDMA) come marker di funzionalità renale nei gatti ipertiroidei prima e dopo terapia medica. La patologia tiroidea più comune nel cane è l’ipotiroidismo. Nello studio riportato al capitolo 5 sono state indagate le performance diagnostiche di freeT3, freeT4, rT3, 3,3-T2 e 3,5-T2, misurati tramite LC-MS/MS, nel differenziare tra cani ipotiroidei, cani con patologie non-tiroidee e cani sani. La presenza di una possibile correlazione tra la gravità della condizione clinica dei pazienti ipotiroidei, le variabili emato-chimiche e le concentrazioni sieriche di cTSH è stata valutata nel capitolo 6. Il capitolo 7 valuta l’andamento dell’SDMA in cani ipotiroidei prima e dopo supplementazione ormonale. A differenza della Sindrome di Cushing dell’uomo, che è considerata una malattia rara, nel cane l’ipercortisolismo spontaneo (HC) è una delle endocrinopatie più comuni. Gli aspetti epidemiologici dell’HC e la ricerca di un metodo di monitoraggio alternativo al test di stimolazione con ACTH nei cani trattati con Trilostano sono stati approfonditi rispettivamente nei capitoli 8 e 9. A differenza dell'HC, l'ipoadrenocorticismo primario (PH) è una patologia rara nel cane. Lo scopo dello studio riportato nel capitolo 10 consiste nel descrivere le frazioni escretorie degli elettroliti urinari nei cani con PH e di indagare se esse possano rappresentare un utile supporto alla diagnosi e al trattamento del PH canino. Il riscontro accidentale di masse surrenaliche rappresenta una criticità diagnostica. Infatti, può essere difficile distinguere morfologicamente tra lesioni corticali e midollari e tra lesioni maligne e benigne. Nel capitolo 11 vengono descritti i rilievi immunoistochimici dell'incidentaloma surrenalico nel cane e viene valutato il ruolo del Ki-67 PI come indicatore di malignità.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Les POCT (point of care tests) ont un grand potentiel d'utilisation en médecine infectieuse ambulatoire grâce à leur rapidité d'exécution, leur impact sur l'administration d'antibiotiques et sur le diagnostic de certaines maladies transmissibles. Certains tests sont utilisés depuis plusieurs années (détection de Streptococcus pyogenes lors d'angine, anticorps anti-VIH, antigène urinaire de S. pneumoniae, antigène de Plasmodium falciparum). De nouvelles indications concernent les infections respiratoires, les diarrhées infantiles (rotavirus, E. coli entérohémorragique) et les infections sexuellement transmissibles. Des POCT, basés sur la détection d'acides nucléiques, viennent d'être introduits (streptocoque du groupe B chez la femme enceinte avant l'accouchement et la détection du portage de staphylocoque doré résistant à la méticilline). POCT have a great potential in ambulatory infectious diseases diagnosis, due to their impact on antibiotic administration and on communicable diseases prevention. Some are in use for long (S. pyogenes antigen, HIV antibodies) or short time (S. pneumoniae antigen, P. falciparum). The additional major indications will be community-acquired lower respiratory tract infections, infectious diarrhoea in children (rotavirus, enterotoxigenic E. coli), and hopefully sexually transmitted infections. Easy to use, these tests based on antigen-antibody reaction allow a rapid diagnosis in less than one hour; the new generation of POCT relying on nucleic acid detection are just introduced in practice (detection of GBS in pregnant women, carriage of MRSA), and will be extended to many pathogens

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Tuberculosis (TB) in South American camelids (SAC) is caused by Mycobacterium bovis or Mycobacterium microti. Two serological methods, rapid testing (RT) and the dual-path platform (DPP) assay, were evaluated using naturally infected SAC. The study population included 156 alpacas and 175 llamas in Great Britain, Switzerland, and the United States. TB due to M. bovis (n = 44) or M. microti (n = 8) in 35 alpacas and 17 llamas was diagnosed by gross pathology examination and culture. Control animals were from herds with no TB history. The RT and the DPP assay showed sensitivities of 71% and 74%, respectively, for alpacas, while the sensitivity for llamas was 77% for both assays. The specificity of the DPP assay (98%) was higher than that of RT (94%) for llamas; the specificities of the two assays were identical (98%) for alpacas. When the two antibody tests were combined, the parallel-testing interpretation (applied when either assay produced a positive result) enhanced the sensitivities of antibody detection to 89% for alpacas and 88% for llamas but at the cost of lower specificities (97% and 93%, respectively), whereas the serial-testing interpretation (applied when both assays produced a positive result) maximized the specificity to 100% for both SAC species, although the sensitivities were 57% for alpacas and 65% for llamas. Over 95% of the animals with evidence of TB failed to produce skin test reactions, thus confirming concerns about the validity of this method for testing SAC. The findings suggest that serological assays may offer a more accurate and practical alternative for antemortem detection of camelid TB.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. The diagnostic value of tests for antimyeloperoxidase antibodies (anti-MPO) for systemic vasculitis is less established than that for cytoplasmic antineutrophil cytoplasmic antibody (cANCA)/antiproteinase 3 antibodies (anti-PR3). Controversy exists regarding the optimal utilization of indirect immunofluorescence (IIF) ANCA testing versus antigen-specific ANCA testing. To summarize the pertinent data, we conducted a metaanalysis examining the diagnostic value of ANCA testing systems that include assays for anti-MPO. Methods. We performed a structured Medline search and reference list review. Target articles in the search strategy were those reporting the diagnostic value of immunoassays for anti-MPO for the spectrum of systemic necrotizing vasculitides that includes Wegener's granulomatosis, microscopic polyangiitis, the Churg-Strauss syndrome, and isolated pauci-immune necrotizing or crescentic glomerulonephritis, regardless of other types of ANCA tests. Inclusion criteria required specification of a consecutive or random patient selection method and the use of acceptable criteria for the diagnosis of vasculitis exclusive of ANCA test results. Weighted pooled summary estimates of sensitivity and specificity were calculated for anti-MPO alone, anti-MPO + perinuclear ANCA (pANCA), and anti-MPO/pANCA + anti-PR3/cANCA. Results. Of 457 articles reviewed, only 7 met the selection criteria. Summary estimates of sensitivity and specificity (against disease controls only) of assays for anti-MPO for the diagnosis of systemic necrotizing vasculitides were 37.1% (confidence interval 26.6% to 47.6%) and 96.3% (CI 94.1% to 98.5%), respectively. When the pANCA pattern by IIF was combined with anti-MPO testing, the specificity improved to 99.4%, with a lower sensitivity, 31.5%. The combined ANCA testing system (anti-PR3/cANCA + anti-MPO/pANCA) increased the sensitivity to 85.5% with a specificity of 98.6%. Conclusion. These results suggest that while anti-MPO is relatively specific for the diagnosis of systemic vasculitis, the combination system of immunoassays for anti-MPO and IIF for pANCA is highly specific and both tests should be used together given the high diagnostic precision required for these conditions. Because patients with ANCA associated vasculitis have either anti-MPO with pANCA or anti-PR3 with cANCA, and rarely both, a combined ANCA testing system including anti-PR3/cANCA and anti-MPO/pANCA is recommended to optimize the diagnostic performance of ANCA testing. (J Rheumatol 2001;28:1584-90)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. This study is defined as study of diagnostic performance. The diagnostic accuracy of 5 visual tests -near convergence point, near accommodation point, stereopsis, contrast sensibility and amsler grid—was evaluated by means of the ROC method (receiver operating characteristics curves), sensitivity, specificity, positive and negative likelihood ratios (LR+/LR−). Visual acuity was used as the reference standard. A sample of 44 elderly aged 76.7 years (±9.32), who were institutionalized, was collected. The curves of contrast sensitivity and stereopsis are the most accurate (area under the curves were 0.814−p = 0.001, C.I.95%[0.653;0.975]— and 0.713−p = 0.027, C.I.95%[0,540;0,887], respectively). The scores with the best diagnostic validity for the stereopsis test were 0.605 (sensitivity 0.87, specificity 0.54; LR+ 1.89, LR−0.24) and 0.610 (sensitivity 0.81, specificity 0.54; LR+1.75, LR−0.36). The scores with higher diagnostic validity for the contrast sensibility test were 0.530 (sensitivity 0.94, specificity 0.69; LR+ 3.04, LR−0.09). The contrast sensitivity and stereopsis test's proved to be clinically useful in detecting vision loss in the elderly.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aging of Portuguese population is characterized by an increase of individuals aged older than 65 years. Preventable visual loss in older persons is an important public health problem. Tests used for vision screening should have a high degree of diagnostic validity confirmed by means of clinical trials. The primary aim of a screening program is the early detection of visual diseases. Between 20% and 50% of older people in the UK have undetected reduced vision and in most cases is correctable. Elderly patients do not receive a systematic eye examination unless a problem arises with their glasses or suspicion vision loss. This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. Furthermore, it pretends to define the ability to find the subjects affected with vision loss as positive and the subjects not affected with the same disease as negative. The ideal vision screening method should have high sensitivity and specificity for early detection of risk factors. It should be also low cost and easy to implement in all geographic and socioeconomic regions. Sensitivity is the ability of an examination to identify the presence of a given disease and specificity is the ability of the examination to identify the absence of a given disease. It was not an aim of this study to detect abnormalities that affect visual acuity. The aim of this study was to find out what´s the best test for the identification of any vision loss.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A significant number of Brazilian gestational-age women are still not tested for HIV, representing a high risk of transmission to their newborns. The current study sought to identify the number of pregnant women with no previous testing or undocumented for HIV referred to the Gynecology and Obstetrics Department of a Regional Teaching Hospital and included diagnosis of HIV infection determined by a rapid test and perinatal transmission in pregnancy. Medical records of all pregnant women admitted to hospital from January 2001 to December 2005 were reviewed. Pregnant women without HIV results were submitted to a rapid HIV test. Those who tested positive were further tested by ELISA and confirmed by indirect immunofluorescence assay (IIA) or Western blot (WB). The viral load from babies born to HIV-infected mothers was assessed by bDNA. Of the 16,424 pregnant women analyzed (6.6%), 1,089 were undocumented for HIV. Eleven women were positive in rapid testing and 10 were confirmed by ELISA, IIA or WB, with 0.9% seropositivity. Mother/infant pairs received zidovudine monotherapy prophylaxis and infant viral load was lower than 50 copies/mL. A higher number of pregnant women previously tested for HIV during antenatal care was verified, compared to that obtained nationwide.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose. To analyze dry eye disease (DED) tests and their consistency in similar nonsymptomatic population samples living in two geographic locations with different climates (Continental vs. Atlantic). Methods. This is a pilot study including 14 nonsymptomatic residents from Valladolid (Continental climate, Spain) and 14 sex-matched and similarly aged residents from Braga (Atlantic climate, Portugal); they were assessed during the same season (spring) of two consecutive years. Phenol red thread test, conjunctival hyperemia, fluorescein tear breakup time, corneal and conjunctival staining, and Schirmer test were evaluated on three different consecutive visits. Reliability was assessed using the intraclass correlation coefficient and weighted kappa (J) coefficient for quantitative and ordinal variables, respectively. Results. Fourteen subjects were recruited in each city with a mean (TSD) age of 63.0 (T1.7) and 59.1 (T0.9) years (p = 0.08) in Valladolid and Braga, respectively. Intraclass correlation coefficient and J values of the tests performed were below 0.69 and 0.61, respectively, for both samples, thus showing moderate to poor reliability. Subsequently, comparisons were made between the results corresponding to the middle and higher outdoor relative humidity (RH) visit in each location as there were no differences in mean temperature (p Q 0.75) despite RH values significantly differing (p e 0.005). Significant (p e 0.05) differences were observed between Valladolid and Braga samples on tear breakup time (middle RH visit, 2.76 T 0.60 vs. 5.26 T 0.64 seconds; higher RH visit, 2.61 T 0.32 vs. 5.78 T 0.88 seconds) and corneal (middle RH, 0.64 T 0.17 vs. 0.14 T 0.10; higher RH, 0.60 T 0.22 vs. 0.0 T 0.0) and conjunctival staining (middle RH, 0.61 T 0.17 vs. 0.14 T 0.08; higher RH, 0.57 T 0.15 vs. 0.18 T 0.09). Conclusions. This pilot study provides initial evidence to support that DED test outcomes assessing the ocular surface integrity and tear stability are climate dependent. Future large-sample studies should support these outcomes also in DED patients. This knowledge is fundamental for multicenter clinical trials. Lack of consistency in diagnostic clinical tests for DED was also corroborated. (Optom Vis Sci 2015;92:e284Ye289)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Biomarker analysis is playing an essential role in cancer diagnosis, prognosis, and prediction. Quantitative assessment of immunohistochemical biomarker expression on tumor tissues is of clinical relevance when deciding targeted treatments for cancer patients. Here, we report a microfluidic tissue processor that permits accurate quantification of the expression of biomarkers on tissue sections, enabled by the ultra-rapid and uniform fluidic exchange of the device. An important clinical biomarker for invasive breast cancer is human epidermal growth factor receptor 2 [(HER2), also known as neu], a transmembrane tyrosine kinase that connotes adverse prognostic information for the patients concerned and serves as a target for personalized treatment using the humanized antibody trastuzumab. Unfortunately, when using state-of-the-art methods, the intensity of an immunohistochemical signal is not proportional to the extent of biomarker expression, causing ambiguous outcomes. Using our device, we performed tests on 76 invasive breast carcinoma cases expressing various levels of HER2. We eliminated more than 90% of the ambiguous results (n = 27), correctly assigning cases to the amplification status as assessed by in situ hybridization controls, whereas the concordance for HER2-negative (n = 31) and -positive (n = 18) cases was 100%. Our results demonstrate the clinical potential of microfluidics for accurate biomarker expression analysis. We anticipate our technique will be a diagnostic tool that will provide better and more reliable data, onto which future treatment regimes can be based.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The MRSA-Screen test (Denka Seiken Co., Ltd., Tokyo, Japan), consisting of a slide latex agglutination kit that detects PBP 2a with a monoclonal antibody, was blindly compared to the oxacillin disk diffusion test, the oxacillin-salt agar screen, and PCR of the mecA gene for the detection of methicillin resistance in Staphylococcus aureus. A total of 120 methicillin-susceptible S. aureus (MSSA) and 80 methicillin-resistant S. aureus (MRSA) isolates, defined by the absence or presence of the mecA gene, respectively, were tested. The MRSA-Screen test, the oxacillin disk diffusion test, and the oxacillin-salt agar screening test showed sensitivities of 100, 61.3, and 82.5% and specificities of 99.2, 96.7, and 98.3%, respectively. We conclude that the MRSA-Screen is a very accurate, reliable, and fast test (15 min) for differentiation of MRSA from MSSA colonies on agar plates.