961 resultados para Radial Artery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Our objective is to test the hypothesis that coronary endothelial function (CorEndoFx) does not change with repeated isometric handgrip (IHG) stress in CAD patients or healthy subjects. BACKGROUND: Coronary responses to endothelial-dependent stressors are important measures of vascular risk that can change in response to environmental stimuli or pharmacologic interventions. The evaluation of the effect of an acute intervention on endothelial response is only valid if the measurement does not change significantly in the short term under normal conditions. Using 3.0 Tesla (T) MRI, we non-invasively compared two coronary artery endothelial function measurements separated by a ten minute interval in healthy subjects and patients with coronary artery disease (CAD). METHODS: Twenty healthy adult subjects and 12 CAD patients were studied on a commercial 3.0 T whole-body MR imaging system. Coronary cross-sectional area (CSA), peak diastolic coronary flow velocity (PDFV) and blood-flow were quantified before and during continuous IHG stress, an endothelial-dependent stressor. The IHG exercise with imaging was repeated after a 10 minute recovery period. RESULTS: In healthy adults, coronary artery CSA changes and blood-flow increases did not differ between the first and second stresses (mean % change ±SEM, first vs. second stress CSA: 14.8%±3.3% vs. 17.8%±3.6%, p = 0.24; PDFV: 27.5%±4.9% vs. 24.2%±4.5%, p = 0.54; blood-flow: 44.3%±8.3 vs. 44.8%±8.1, p = 0.84). The coronary vasoreactive responses in the CAD patients also did not differ between the first and second stresses (mean % change ±SEM, first stress vs. second stress: CSA: -6.4%±2.0% vs. -5.0%±2.4%, p = 0.22; PDFV: -4.0%±4.6% vs. -4.2%±5.3%, p = 0.83; blood-flow: -9.7%±5.1% vs. -8.7%±6.3%, p = 0.38). CONCLUSION: MRI measures of CorEndoFx are unchanged during repeated isometric handgrip exercise tests in CAD patients and healthy adults. These findings demonstrate the repeatability of noninvasive 3T MRI assessment of CorEndoFx and support its use in future studies designed to determine the effects of acute interventions on coronary vasoreactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a weakly nonlinear analysis of the interface dynamics in a radial Hele-Shaw cell driven by both injection and rotation. We extend the systematic expansion introduced in [E. Alvarez-Lacalle et al., Phys. Rev. E 64, 016302 (2001)] to the radial geometry, and compute explicitly the first nonlinear contributions. We also find the necessary and sufficient condition for the uniform convergence of the nonlinear expansion. Within this region of convergence, the analytical predictions at low orders are compared satisfactorily to exact solutions and numerical integration of the problem. This is particularly remarkable in configurations (with no counterpart in the channel geometry) for which the interplay between injection and rotation allows that condition to be satisfied at all times. In the case of the purely centrifugal forcing we demonstrate that nonlinear couplings make the interface more unstable for lower viscosity contrast between the fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radial displacement of a fluid annulus in a rotating circular Hele-Shaw cell has been investigated experimentally. It has been found that the flow depends sensitively on the wetting conditions at the outer interface. Displacements in a prewet cell are well described by Darcy's law in a wide range of experimental parameters, with little influence of capillary effects. In a dry cell, however, a more careful analysis of the interface motion is required; the interplay between a gradual loss of fluid at the inner interface, and the dependence of capillary forces at the outer interface on interfacial velocity and dynamic contact angle, result in a constant velocity for the interfaces. The experimental results in this case correlate in the form of an empirical scaling relation between the capillary number Ca and a dimensionless group, related to the ratio of centrifugal to capillary forces, which spans about three orders of magnitude in both quantities. Finally, the relative thickness of the coating film left by the inner interface, alpha i, is obtained as a function of Ca.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pendant la grossesse, la pression artérielle reste stable malgré une nette augmentation du volume d'éjection systolique et du débit cardiaque. Cette stabilité vient d'un côté d'une vasodilatation périphérique entraînant une diminution des résistances périphériques et d'un autre côté d'une moindre rigidité des principales artères notamment l'aorte. En conséquence, l'amplitude des ondes de pouls est atténuée, de même que leur vitesse de propagation dans le sens tant antérogade que rétrograde (ondes réfléchies). Les ondes réfléchies tendent ainsi à atteindre l'aorte ascendante plus tard durant la systole, voire durant la diastole, ce qui peut contribuer à diminuer la pression puisée. La prééclampsie perturbe massivement ce processus d'adaptation. Il s'agit d'une maladie hypertensive de la grossesse engendrant une importante morbidité et mortalité néonatale et maternelle. Il est à remarquer que la diminution de la rigidité artérielle n'est pas observée chez les patientes atteintes avec pour conséquence une forte augmentation de la pression systolique centrale (aortique) par les ondes réfléchies. Ce fait a été établi grâce à l'existence de la tonométrie d'aplanation, une méthode permettant l'évaluation non invasive de l'onde de pouls centrale. Dans cette méthode, un senseur de pression piézo-électrique permet de capter l'onde de pouls périphérique, le plus souvent sur l'artère radiale. Par la suite, un algorithme validé permet d'en déduire la forme de l'onde de pouls centrale et de visualiser à quel moment du cycle cardiaque s'y ajoutent les ondes réfléchies. Plusieurs études font état d'une forte augmentation de la pression systolique centrale par les ondes réfléchies chez les patientes atteintes de prééclampsie, suggérant l'utilisation de cette méthode pour le diagnostic et le monitoring voire pour le dépistage de ces patientes. Pour atteindre ce but, il est nécessaire d'établir des normes en rapport notamment avec l'âge gestationnel. Dans la littérature, les données pertinentes actuellement disponibles sont variables, voire contradictoires. Par exemple, les ondes réfléchies proéminentes dans la partie diastolique de l'onde de pouls centrale disparaissaient chez des patientes enceintes au 3eme trimestre comparées à des contrôles non enceintes dans une étude lausannoise, alors que deux autres études présentent l'observation contraire. Autre exemple, certains auteurs décrivent une diminution progressive de l'augmentation systolique jusqu'à l'accouchement alors que d'autres rapportent un nadir aux environs du 6ème mois, suivi d'un retour à des valeurs plus élevées en fin de grossesse. Les mesures effectuées dans toutes ces études différaient dans leur exécution, les patientes étant notamment dans des postions corporelles différentes (couchées, semi-couchées, assises, en décubitus latéral). Or nous savons que le status hémodynamique est très sensible aux changements de position, particulièrement durant la grossesse où l'utérus gravide est susceptible d'avoir des interactions mécaniques avec les veines et possiblement les artères abdominales. Ces différences méthodologiques pourraient donc expliquer, au moins en partie, l'hétérogénéité des résultats concernant l'onde de pouls chez la femme enceinte, ce qui à notre connaissance n'a jamais été exploré. Nous avons mesuré l'onde de pouls dans les positions assise et couchée chez des femmes enceintes, au 3eme trimestre d'une grossesse non compliquée, et nous avons effectué une comparaison avec des données similaire obtenues chez des femmes non enceintes en bonne santé habituelle. Les résultats montrent que la position du corps a un impact majeur sur la forme de l'onde de pouls centrale. Comparée à la position assise, la position couchée se caractérise par une moindre augmentation systolique et, par contraste, une augmentation diastolique plus marquée. De manière inattendue, cet effet s'observe aussi bien en présence qu'en l'absence de grossesse, suggérant que la cause première n'en réside pas dans les interactions mécaniques de l'utérus gravide avec les vaisseaux sanguins abdominaux. Nos observations pourraient par contre être expliquées par l'influence de la position du corps, via un phénomène hydrostatique simple, sur la pression transmurale des artères éloignées du coeur, tout particulièrement celles des membres inférieurs et de l'étage abdominal. En position verticale, ces vaisseaux augmenteraient leur rigidité pour résister à la distension de leur paroi, ce qui y accroîtrait la vitesse de propagation des ondes de pression. En l'état, cette explication reste hypothétique. Mais quoi qu'il en soit, nos résultats expliquent certaines discordances entre les études conduites à ce jour pour caractériser l'influence de la grossesse physiologique sur la forme de l'onde de pouls central. De plus, ils indiquent que la position du corps doit être prise en compte lors de toute investigation utilisant la tonométrie d'applanation pour déterminer la rigidité des artères chez les jeunes femmes enceintes ou non. Il sera aussi nécessaire d'en tenir compte pour établir des normes en vue d'une utilisation de la tonométrie d'aplanation pour dépister ou suivre les patientes atteintes de prééclampsie. Il serait enfin intéressant d'évaluer si l'effet de la position sur la forme de l'onde de pouls central existe également dans l'autre sexe et chez des personnes plus âgées.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The purpose of this study was the investigation of the impact of real-time adaptive motion correction on image quality in navigator-gated, free-breathing, double-oblique three-dimensional (3D) submillimeter right coronary magnetic resonance angiography (MRA). MATERIALS AND METHODS: Free-breathing 3D right coronary MRA with real-time navigator technology was performed in 10 healthy adult subjects with an in-plane spatial resolution of 700 x 700 microm. Identical double-oblique coronary MR-angiograms were performed with navigator gating alone and combined navigator gating and real-time adaptive motion correction. Quantitative objective parameters of contrast-to-noise ratio (CNR) and vessel sharpness and subjective image quality scores were compared. RESULTS: Superior vessel sharpness, increased CNR, and superior image quality scores were found with combined navigator gating and real-time adaptive motion correction (vs. navigator gating alone; P < 0.01 for all comparisons). CONCLUSION: Real-time adaptive motion correction objectively and subjectively improves image quality in 3D navigator-gated free-breathing double-oblique submillimeter right coronary MRA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Chest pain can be caused by various conditions, with life-threatening cardiac disease being of greatest concern. Prediction scores to rule out coronary artery disease have been developed for use in emergency settings. We developed and validated a simple prediction rule for use in primary care. METHODS: We conducted a cross-sectional diagnostic study in 74 primary care practices in Germany. Primary care physicians recruited all consecutive patients who presented with chest pain (n = 1249) and recorded symptoms and findings for each patient (derivation cohort). An independent expert panel reviewed follow-up data obtained at six weeks and six months on symptoms, investigations, hospital admissions and medications to determine the presence or absence of coronary artery disease. Adjusted odds ratios of relevant variables were used to develop a prediction rule. We calculated measures of diagnostic accuracy for different cut-off values for the prediction scores using data derived from another prospective primary care study (validation cohort). RESULTS: The prediction rule contained five determinants (age/sex, known vascular disease, patient assumes pain is of cardiac origin, pain is worse during exercise, and pain is not reproducible by palpation), with the score ranging from 0 to 5 points. The area under the curve (receiver operating characteristic curve) was 0.87 (95% confidence interval [CI] 0.83-0.91) for the derivation cohort and 0.90 (95% CI 0.87-0.93) for the validation cohort. The best overall discrimination was with a cut-off value of 3 (positive result 3-5 points; negative result <or= 2 points), which had a sensitivity of 87.1% (95% CI 79.9%-94.2%) and a specificity of 80.8% (77.6%-83.9%). INTERPRETATION: The prediction rule for coronary artery disease in primary care proved to be robust in the validation cohort. It can help to rule out coronary artery disease in patients presenting with chest pain in primary care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Plusieurs études suggèrent que les populations vivant en haute altitude sont mieux protégées contre l'hypertension pulmonaire hypoxique que celles originaires de la plaine. Cependant, les mécanismes sous jacents ne sont pas bien compris. Chez les Tibétains, la synthèse augmentée par le système respiratoire de monoxyde d'azote (NO) atténue l'hypertension pulmonaire hypoxique. Il a été spéculé que ce mécanisme pourrait représenter un mode généralisé d'adaptation à la haute altitude, mais il n'existe pas de preuve directe qui consume cette hypothèse. Nous avons donc mesuré la pression artérielle pulmonaire (par échocardiographie Doppler) ainsi que la concentration du NO dans l'air exhalé chez 34 Boliviens en bonne santé, nés et ayant toujours vécus en haute altitude (3600 m) et chez 34 Caucasiens apparentés pour l'âge et le sexe, nés en basse altitude mais vivant depuis de nombreuses années à cette même haute altitude (3600 mètres). La pression artérielle pulmonaire (24.3±5.9 vs. 24.7±4.9 mm Hg) et le NO exhalé (19.2±7.2 vs. 22.5±9.5 ppb) étaient similaires chez les Boliviens et les Caucasiens. Il n'y avait aucune corrélation entre la pression artérielle pulmonaire et le NO respiratoire dans les deux groupes. Ces résultats ne fournissent donc aucune évidence que les Boliviens nés en haute altitude sont mieux protégés contre l'hypertension pulmonaire hypoxique que les Caucasiens nés à basse altitude. Cela suggère que l'atténuation de l'hypertension pulmonaire par une synthèse accrue de NO respiratoire ne représente pas un mode universel d'adaptation des populations à la haute altitude. Abstract : There is evidence that high altitude populations may be better protected from hypoxic pulmonary hypertension than low altitude natives, but the underlying mechanism is incompletely understood. In Tibetans, increased pulmonary respiratory NO synthesis attenuates hypoxic pulmonary hypertension. It has been speculated that this mechanism may represent a generalized high altitude adaptation pattern, but direct evidence for this speculation is lacking. We therefore measured systolic pulmonary-artery pressure (Doppler echocardiography) and exhaled nitric oxide (NO) in 34 healthy, middle-aged Bolivian high altitude natives and in 34 age- and sex-matched, well-acclimatized Caucasian low altitude natives living at high altitude (3600 m). The mean ± SD systolic right ventricular to right arterial pressure gradient (24.3 ± 5.9 vs. 24.7 ± 4.9 mmHg) and exhaled NO (19.2 ± 7.2 vs. 22.5 ± 9.5 ppb) were similar in Bolivians and Caucasians. There was no relationship between ,pulmonary-artery pressure and respiratory NO in the two groups. These findings provide no evidence that Bolivian high altitude natives are better protected from hypoxic pulmonary hypertension than Caucasian low altitude natives and suggest that attenuation of pulmonary hypertension by increased respiratory NO synthesis may not represent a universal adaptation pattern in highaltitude populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liver vascularization is known to present with several different variations. Generally, a normal vascular anatomy is reported in up to 50-80 % of cases. For this reason, a precise preoperative mapping of the hepatic vascularization prior to pancreatic surgery is essential to avoid injuries and subsequent complications. We report here a case of a young patient scheduled for Whipple procedure, who presented an arterial pattern type Michels IV, variation reported in 0.6 to 3 % in the literature. Another interesting particularity of this case was the fact that the right hepatic artery had a prepancreatic course. We think that every surgeon performing hepatopancreatic surgery should have heard of this special and rare situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Impaired blood flow of the gastric tube represents a major cause of anastomotic leakage after esophageal resection. In order to improve local vascularisation, preoperative embolization (PE) of the left gastric artery has recently been proposed. The aimof this study was to assess our initial experience of this novel approach with a particular focus on anastomotic leakage.Methods: A consecutive series of 102 patients (81 male, 21 female, median age 64 years) underwent resection (82 Ivor-Lewis procedures, 9 transhiatal resections, 11 triple incisions) for esophageal malignancies at our institution from 2000 to 2009. Since 2004, PE was used selectively in 19 patients 21 days prior to elective esophagectomy. Selection criteria were normal gastric vascular anatomy, no pre-existing vascular disease, i.e. atheromatosis of the celiac trunk or superior mesenteric artery, and resectability of the tumor. PE was performed under local anesthesia on a dedicated system in a standard fashion. Following percutaneous transfemoral visceral angiography to identify gastric vascular anatomy, embolization was performed either with 5-F or with coaxial 3-F catheters and fibered metal coils. We analyzed retrospectively patient's data, operative data, and outcome from a prospective database.Results: The overall anastomotic leakage rate was 18・6% (19/102 patients); cervical anastomosis had a leak rate of 25% compared to intrathoracic anastomosis leak rate of 18・2%. While 17 of 83 patients without PE developed anastomotic leakage (20・5%), there were only 2 of 19 patients after PE revealing an anastomotic leakage (10・5%). Otherwise, patients with PE had no more other complications. There was only one PE-related complication (i.e. partial splenic necrosis).Mean hospital stay was 25 days versus 27 days for patients with PE and without PE, respectively. The mortality rate was 7・8% (8/102 patients), whereby four deaths were related to anastomotic leakage (1 and 3 patients with PE and without PE, respectively).Conclusion: PE is an interesting novel approach to improve gastric blood flow in order to minimize anastomotic leakage. Its application is safe and technically easy. Our preliminary experience revealed a decrease of the anastomotic leakage rate of almost 50%.