976 resultados para RADIATION DOSAGE
Resumo:
PURPOSE: In this study, we investigated the mechanisms by which temozolomide enhances radiation response in glioblastoma cells. EXPERIMENTAL DESIGN: Using a panel of four primary human glioblastoma cell lines with heterogeneous O(6)-methylguanine-DNA methyltransferase (MGMT) protein expression, normal human astrocytes, and U87 xenografts, we investigated (a) the relationship of MGMT status with efficacy of temozolomide-based chemoradiation using a panel of in vitro and in vivo assays; (b) underlying mechanisms by which temozolomide enhances radiation effect in glioblastoma cells; and (c) strategies to overcome resistance to radiation + temozolomide. RESULTS: Temozolomide enhances radiation response most effectively in glioblastomas without detectable MGMT expression. On concurrent radiation + temozolomide administration in MGMT-negative glioblastomas, there seems to be decreased double-strand DNA (dsDNA) repair capacity and enhanced dsDNA damage compared either with radiation alone or with sequentially administered temozolomide. Our data suggest that O(6)-benzylguanine can enhance the antitumor effects of concurrent radiation + temozolomide in MGMT-positive cells by enhancing apoptosis and the degree of dsDNA damage. O(6)-Benzylguanine was most effective when administered concurrently with radiation + temozolomide and had less of an effect when administered with temozolomide in the absence of radiation or when administered sequentially with radiation. Our in vivo data using U87 xenografts confirmed our in vitro findings. CONCLUSIONS: The present study shows that temozolomide enhances radiation response most effectively in MGMT-negative glioblastomas by increasing the degree of radiation-induced double-strand DNA damage. In MGMT-positive glioblastomas, depletion of MGMT by the addition of O(6)-benzylguanine significantly enhances the antitumor effect of concurrent radiation + temozolomide. These are among the first data showing mechanisms of synergy between radiation and temozolomide and the effect of MGMT.
Resumo:
Aim: 125I-iododeoxyuridine is a potential Auger radiation therapy agent. Its incorporation in DNA of proliferating cells is enhanced by fluorodeoxyuridine. Here, we evaluated therapeutic activities of 125I-iododeoxyuridine in an optimized fluorodeoxyuridine pre-treatment inducing S-phase synchronization. Methods: After S-phase synchronization by fluorodeoxyuridine, cells were treated with 125I-iododeoxyuridine. Apoptosis analysis and S-phase synchronization were studied by flow cytometry. Cell survival was determined by colony-forming assay. Based on measured growth parameters, the number of decays per cell that induced killing was extrapolated. Results: Treatment experiments showed that 72 to 91% of synchronized cells were killed after 0.8 and 8 kBq/ml 125I-iododeoxyuridine incubation, respectively. In controls, only 8 to 38% of cells were killed by corresponding 125I-iododeoxyuridine activities alone and even increasing the activity to 80 kBq/ml gave only 42 % killing. Duplicated treatment cycles or repeated fluorodeoxyuridine pre-treatment allowed enhancing cell killing to >95 % at 8 kBq/ml 125I-iododeoxyuridine. About 50 and 160 decays per S-phase cells in controls and S-phase synchronization, respectively, were responsible for the observed cell killing at 0.8 kBq/ml radio-iododeoxyuridine. Conclusion: These data show the successful application of fluorodeoxyuridine that provided increased 125I-iododeoxyuridine Auger radiation cell killing efficacy through S-phase synchronization and high DNA incorporation of radio-iododeoxyuridine.
Resumo:
OBJECTIVES: The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS: A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS: The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS: This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."
Resumo:
Families of clonally expressed major histocompatibility complex (MHC) class I-specific receptors provide specificity to and regulate the function of natural killer (NK) cells. One of these receptors, mouse Ly49A, is expressed by 20% of NK cells and inhibits the killing of H-2D(d) but not D(b)-expressing target cells. Here, we show that the trans-acting factor TCF-1 binds to two sites in the Ly49A promoter and regulates its activity. Moreover, we find that TCF-1 determines the size of the Ly49A NK cell subset in vivo in a dosage-dependent manner. We propose that clonal Ly49A acquisition during NK cell development is regulated by TCF-1.
Resumo:
Brain perfusion can be assessed by CT and MR. For CT, two major techniquesare used. First, Xenon CT is an equilibrium technique based on a freely diffusibletracer. First pass of iodinated contrast injected intravenously is a second method,more widely available. Both methods are proven to be robust and quantitative,thanks to the linear relationship between contrast concentration and x-ray attenuation.For the CT methods, concern regarding x-ray doses delivered to the patientsneed to be addressed. MR is also able to assess brain perfusion using the firstpass of gadolinium based contrast agent injected intravenously. This method hasto be considered as a semi-quantitative because of the non linear relationshipbetween contrast concentration and MR signal changes. Arterial spin labelingis another MR method assessing brain perfusion without injection of contrast. Insuch case, the blood flow in the carotids is magnetically labelled by an externalradiofrequency pulse and observed during its first pass through the brain. Eachof this various CT and MR techniques have advantages and limits that will be illustratedand summarised.Learning Objectives:1. To understand and compare the different techniques for brain perfusionimaging.2. To learn about the methods of acquisition and post-processing of brainperfusion by first pass of contrast agent for CT and MR.3. To learn about non contrast MR methods (arterial spin labelling).
Resumo:
Hyperhomocysteinemia represents an independent risk factor for atherothrombotic disease. Physiopathological mechanisms of accelerated progression of atherosclerosis in presence of hyperhomocysteinemia are complex. Herein we report a clinical case which emphasis the importance of screening elevated homocystein in the absence of conventional risk factors in patients who suffer from premature atherosclerosis.
Resumo:
BACKGROUND: Physiological changes associated with pregnancy may alter antiretroviral plasma concentrations and might jeopardize prevention of mother-to-child HIV transmission. Lopinavir is one of the protease inhibitors more frequently prescribed during pregnancy in Europe. We described the free and total pharmacokinetics of lopinavir in HIV-infected pregnant and non-pregnant women, and evaluated whether significant alterations in its disposition and protein binding warrant systematic dosage adjustment. METHODS: Plasma samples were collected at first, second and third trimester of pregnancy, at delivery, in umbilical cord and postpartum. Lopinavir free and total plasma concentrations were measured by HPLC-MS/MS. Bayesian calculations were used to extrapolate total concentrations to trough (Cmin). RESULTS: A total of 42 HIV-positive pregnant women and 37 non-pregnant women on lopinavir/ritonavir were included in the study. Compared to postpartum and control values, total lopinavir Cmin was decreased moderately (31-39%) during pregnancy, and free Cmin minimally, showing significant alteration only at delivery (-35%). However, total and free Cmin remained in all patients above the target concentrations for wild-type virus of 1,000 ng/ml, and above the unbound IC50(WT) of 0.64-0.77 ng/ml of lopinavir, respectively. Lopinavir free fractions remained higher during pregnancy compared to postpartum and controls, and were influenced by α-1-acid-glycoprotein and albumin decrease. Free cord-to-mother ratio (0.43) was 2.7-fold higher than total cord-to-mother ratio (0.16), suggesting higher fetal exposure. CONCLUSIONS: The moderate decrease of total lopinavir concentrations during pregnancy is not associated with proportional decrease in free concentrations. Both reach a nadir at delivery, albeit not to an extent that would put treatment-naive women at risk of insufficient exposure to the free, pharmacologically active concentrations of lopinavir. No dosage adjustment is therefore needed during pregnancy as it is unlikely to further enhance treatment efficacy but could potentially increase the risk of maternal and fetal toxicity. Nonetheless, in case of viral resistance in treatment-experienced pregnant women, loss of virological control or questionable adherence, it is justified to consider lopinavir dosage adjustment based on total plasma concentration measurement.
Resumo:
The objective of this work was to develop neural network models of backpropagation type to estimate solar radiation based on extraterrestrial radiation data, daily temperature range, precipitation, cloudiness and relative sunshine duration. Data from Córdoba, Argentina, were used for development and validation. The behaviour and adjustment between values observed and estimates obtained by neural networks for different combinations of input were assessed. These estimations showed root mean square error between 3.15 and 3.88 MJ m-2 d-1 . The latter corresponds to the model that calculates radiation using only precipitation and daily temperature range. In all models, results show good adjustment to seasonal solar radiation. These results allow inferring the adequate performance and pertinence of this methodology to estimate complex phenomena, such as solar radiation.
Resumo:
The efficacy and safety of anti-infective treatments are associated with the drug blood concentration profile, which is directly correlated with a dosing adjustment to the individual patient's condition. Dosing adjustments to the renal function recommended in reference books are often imprecise and infrequently applied in clinical practice. The recent generalisation of the KDOQI (Kidney Disease Outcome Quality Initiative) staging of chronically impaired renal function represents an opportunity to review and refine the dosing recommendations in patients with renal insufficiency. The literature has been reviewed and compared to a predictive model of the fraction of drug cleared by the kidney based on the Dettli's principle. Revised drug dosing recommendations integrating these predictive parameters are proposed.
Resumo:
A discussion on the importance and pathogenesis of radiation-induced pneumonitis and fibrosis is provided, with a special focus on the role of the immune system. The need to understand this interaction is highlighted in view of emerging therapeutic potential.
Resumo:
The comparison of radiotherapy techniques regarding secondary cancer risk has yielded contradictory results possibly stemming from the many different approaches used to estimate risk. The purpose of this study was to make a comprehensive evaluation of different available risk models applied to detailed whole-body dose distributions computed by Monte Carlo for various breast radiotherapy techniques including conventional open tangents, 3D conformal wedged tangents and hybrid intensity modulated radiation therapy (IMRT). First, organ-specific linear risk models developed by the International Commission on Radiological Protection (ICRP) and the Biological Effects of Ionizing Radiation (BEIR) VII committee were applied to mean doses for remote organs only and all solid organs. Then, different general non-linear risk models were applied to the whole body dose distribution. Finally, organ-specific non-linear risk models for the lung and breast were used to assess the secondary cancer risk for these two specific organs. A total of 32 different calculated absolute risks resulted in a broad range of values (between 0.1% and 48.5%) underlying the large uncertainties in absolute risk calculation. The ratio of risk between two techniques has often been proposed as a more robust assessment of risk than the absolute risk. We found that the ratio of risk between two techniques could also vary substantially considering the different approaches to risk estimation. Sometimes the ratio of risk between two techniques would range between values smaller and larger than one, which then translates into inconsistent results on the potential higher risk of one technique compared to another. We found however that the hybrid IMRT technique resulted in a systematic reduction of risk compared to the other techniques investigated even though the magnitude of this reduction varied substantially with the different approaches investigated. Based on the epidemiological data available, a reasonable approach to risk estimation would be to use organ-specific non-linear risk models applied to the dose distributions of organs within or near the treatment fields (lungs and contralateral breast in the case of breast radiotherapy) as the majority of radiation-induced secondary cancers are found in the beam-bordering regions.
Resumo:
Purpose: Diagnostic radiology involving ionizing radiation often leads to crucial information but also involves risk. Estimated cancer risks associated with CT range between 1 in 1000 to 1 in 10 000, depending on age and exposure settings. The aim of this contribution is to provide radiologists a way to inform a patient about these risks on a collective and individual base. Materials and methods: After a brief review of the effects of ionizing radiations, conversion from dose indicators into effective dose will be presented for radiography, fluoroscopy and CT. The Diagnostic Reference Level (DRL) concept will be then introduced to enable the reader to compare the level of exposure of various examinations. Finally, the limit of effective dose will be explained and risk projections after various radiological procedures for adults and children will be presented. Results: From an individual standpoint the benefit of a well justified and optimized CT examination clearly outweigh its risk of inducing a fatal cancer. The uncertainties associated with the effective dose concept should be kept in mind in order to avoid cancer risk projections after an examination on an individual basis. Conclusion: Risk factors or effective dose are not the simplest tools to communicate when dealing with radiological risks. Thus, a set of categories should be preferred as proposed in the ICRP (International Commission on Radiation Protection) report 99.