966 resultados para Produto dose-comprimento (DLP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: CYP2D6 is the key enzyme responsible for tamoxifen bioactivation mainly into endoxifen. This gene is highly polymorphic and breast cancer patients classified as CYP2D6 poor metabolizers (PM) or intermediate metabolizers (IM) appear to show low concentrations of endoxifen and to achieve less benefit from tamoxifen treatment. Purpose: This prospective, open-label trial aimed to assess how the increase of tamoxifen dose influences the level of endoxifen in the different genotype groups (poor-, intermediate-, and extensive-metabolizers (EM)). We examined the impact of doubling tamoxifen dose to 20mg twice daily on endoxifen plasma concentrations across these genotype groups. Patients and methods: Patients were assayed for CYP2D6 genotype and phenotype using dextromethorphan test. Tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen plasma levels were determined on 2 occasions at baseline (20mg/day of tamoxifen) and at day 30, 90 and 120 after dose increase (20 mg twice daily) using liquid chromatography-tandem-mass spectrometry. Endoxifen plasma levels were measured 6 to 24 hours after last drug intake to evaluate its accumulation before and after doubling tamoxifen dosage. ANOVA was used to evaluate endoxifen levels increase and difference between genotype groups. Results: 63 patients are available for analysis to date. Tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen plasma reached steady state at 30 day after tamoxifen dose escalation, with a significant increase compared to baseline by 1.6 to 1.8 fold : geometric mean plasma concentrations (CV %) were 140 ng/mL (45%) at baseline vs 255 (47%) at day 30 for tamoxifen (P < 0.0001); 256 (49%) vs 408 (64%) for N-desmethyltamoxifen (P < 0.0001); 2.4 (46%) vs 3.9 (51%) for 4-OH-tamoxifen (P < 0.0001); and 20 (91%) vs 33 (91%) for endoxifen (P < 0.02). On baseline, endoxifen levels tended to be lower in PM: 7 ng/mL (36%), than IM: 16 ng/mL (70%), P=0.08, and EM: 24 ng/mL (71%), P<0.001. After doubling tamoxifen dosage, endoxifen concentrations rose similarly in PM, IM and EM with respectively, 1.5 (18%), 1.5 (28%) and 1.7 (30%) fold increase from baseline, P=0.18. Conclusion: Endoxifen exposure varies widely under standard tamoxifen dosage, with CYP2D6 genotype explaining only a minor part of this variability. It increases consistently on doubling tamoxifen dose, similarly across genotypes. This would enable exposure optimization based on concentration monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dentre as várias competências das organizações, a gestão de preço assume um papel importante nas decisões estratégicas, na rentabilidade e na geração de renda. Em face dessa relevância, propõe-se um modelo conceitual visando à mensuração da imagem de preço de produto, do qual resultou a proposição de 19 hipóteses de pesquisa. A imagem de preço pode ser definida como uma variável latente e multidimensional. A partir de revisão, refinamento e integração de conceitos da literatura, identificaram-se sete dimensões que podem compor melhor a imagem de preço de produto: funcional, emocional positiva, emocional negativa, simbólica, justiça, axiomática e social. Essas sete dimensões auxiliam a entender melhor como pode ser configurada a imagem de preço, pois as múltiplas dimensões explicam melhor as escolhas do consumidor do que simplesmente o item valor para o dinheiro. Verificou-se, ainda, que essas dimensões da imagem do preço estão relacionadas entre si, e o envolvimento do consumidor modera a relação entre as dimensões da imagem e o valor percebido do produto. Dentre as contribuições deste artigo destacam-se: em primeiro lugar, a identificação da configuração da imagem de preço a partir do entendimento das principais dimensões que a formam; em segundo lugar, a proposição de um modelo teórico integrativo que serve de base para a mensuração da imagem de preço de produto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No estudo relatado neste artigo, o objetivo foi testar um modelo teórico proposto por De Toni e Mazzon visando à mensuração do valor percebido do preço de um produto ou serviço. Com base em um framework conceitual, avaliou-se o impacto das dimensões antecedentes funcional, emocional positiva e negativa, de justiça, axiomática, simbólica e social sobre o valor percebido do preço e consequente intenção de compra. Para tanto, propuseram-se escalas para mensuração desses construtos, tendo-se efetuado a purificação dessas escalas com base em testes e análises estatísticas aplicadas a dois estudos piloto. Em seguida foram analisados indicadores da aplicação de análise fatorial confirmatória, com o propósito de aferir a confiabilidade e a validade das escalas propostas, tomando-se por base uma amostra de 337 casos válidos. Pôde-se verificar, tanto em relação aos indicadores de ajuste do modelo teórico quanto no teste das hipóteses propostas, que os resultados obtidos se mostraram válidos e confiáveis para a situação analisada. Como contribuição teórica do estudo, apresentam-se a operacionalização do framework integrativo proposto e as respectivas escalas com a medida do impacto relativo que cada construto tem no valor percebido do preço e na intenção de compra de um bem ou serviço.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMOFertilizantes são importantes para a produção agrícola mundial devido à melhoria de produtividade que proporcionam. Neste artigo, utiliza-se a teoria de opções reais para avaliar a opção de troca de produto final, amônia ou ureia, em uma fábrica de fertilizantes nitrogenados. O método de simulação Monte Carlo foi utilizado para definir o valor da opção de troca na fábrica de fertilizantes, considerando as incertezas nos preços do gás natural (principal matéria-prima), amônia e ureia, assumindo que esses seguissem um movimento de reversão à média. Nos resultados, aponta-se que essa opção é relevante na análise de projetos de fábricas de fertilizantes, podendo ser fundamental, em muitos casos, sua consideração para a viabilidade do projeto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La tomodensitométrie (CT) est une technique d'imagerie dont l'intérêt n'a cessé de croître depuis son apparition dans le début des années 70. Dans le domaine médical, son utilisation est incontournable à tel point que ce système d'imagerie pourrait être amené à devenir victime de son succès si son impact au niveau de l'exposition de la population ne fait pas l'objet d'une attention particulière. Bien évidemment, l'augmentation du nombre d'examens CT a permis d'améliorer la prise en charge des patients ou a rendu certaines procédures moins invasives. Toutefois, pour assurer que le compromis risque - bénéfice soit toujours en faveur du patient, il est nécessaire d'éviter de délivrer des doses non utiles au diagnostic.¦Si cette action est importante chez l'adulte elle doit être une priorité lorsque les examens se font chez l'enfant, en particulier lorsque l'on suit des pathologies qui nécessitent plusieurs examens CT au cours de la vie du patient. En effet, les enfants et jeunes adultes sont plus radiosensibles. De plus, leur espérance de vie étant supérieure à celle de l'adulte, ils présentent un risque accru de développer un cancer radio-induit dont la phase de latence peut être supérieure à vingt ans. Partant du principe que chaque examen radiologique est justifié, il devient dès lors nécessaire d'optimiser les protocoles d'acquisitions pour s'assurer que le patient ne soit pas irradié inutilement. L'avancée technologique au niveau du CT est très rapide et depuis 2009, de nouvelles techniques de reconstructions d'images, dites itératives, ont été introduites afin de réduire la dose et améliorer la qualité d'image.¦Le présent travail a pour objectif de déterminer le potentiel des reconstructions itératives statistiques pour réduire au minimum les doses délivrées lors d'examens CT chez l'enfant et le jeune adulte tout en conservant une qualité d'image permettant le diagnostic, ceci afin de proposer des protocoles optimisés.¦L'optimisation d'un protocole d'examen CT nécessite de pouvoir évaluer la dose délivrée et la qualité d'image utile au diagnostic. Alors que la dose est estimée au moyen d'indices CT (CTDIV0| et DLP), ce travail a la particularité d'utiliser deux approches radicalement différentes pour évaluer la qualité d'image. La première approche dite « physique », se base sur le calcul de métriques physiques (SD, MTF, NPS, etc.) mesurées dans des conditions bien définies, le plus souvent sur fantômes. Bien que cette démarche soit limitée car elle n'intègre pas la perception des radiologues, elle permet de caractériser de manière rapide et simple certaines propriétés d'une image. La seconde approche, dite « clinique », est basée sur l'évaluation de structures anatomiques (critères diagnostiques) présentes sur les images de patients. Des radiologues, impliqués dans l'étape d'évaluation, doivent qualifier la qualité des structures d'un point de vue diagnostique en utilisant une échelle de notation simple. Cette approche, lourde à mettre en place, a l'avantage d'être proche du travail du radiologue et peut être considérée comme méthode de référence.¦Parmi les principaux résultats de ce travail, il a été montré que les algorithmes itératifs statistiques étudiés en clinique (ASIR?, VEO?) ont un important potentiel pour réduire la dose au CT (jusqu'à-90%). Cependant, par leur fonctionnement, ils modifient l'apparence de l'image en entraînant un changement de texture qui pourrait affecter la qualité du diagnostic. En comparant les résultats fournis par les approches « clinique » et « physique », il a été montré que ce changement de texture se traduit par une modification du spectre fréquentiel du bruit dont l'analyse permet d'anticiper ou d'éviter une perte diagnostique. Ce travail montre également que l'intégration de ces nouvelles techniques de reconstruction en clinique ne peut se faire de manière simple sur la base de protocoles utilisant des reconstructions classiques. Les conclusions de ce travail ainsi que les outils développés pourront également guider de futures études dans le domaine de la qualité d'image, comme par exemple, l'analyse de textures ou la modélisation d'observateurs pour le CT.¦-¦Computed tomography (CT) is an imaging technique in which interest has been growing since it first began to be used in the early 1970s. In the clinical environment, this imaging system has emerged as the gold standard modality because of its high sensitivity in producing accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase of the number of CT examinations performed has raised concerns about the potential negative effects of ionizing radiation on the population. To insure a benefit - risk that works in favor of a patient, it is important to balance image quality and dose in order to avoid unnecessary patient exposure.¦If this balance is important for adults, it should be an absolute priority for children undergoing CT examinations, especially for patients suffering from diseases requiring several follow-up examinations over the patient's lifetime. Indeed, children and young adults are more sensitive to ionizing radiation and have an extended life span in comparison to adults. For this population, the risk of developing cancer, whose latency period exceeds 20 years, is significantly higher than for adults. Assuming that each patient examination is justified, it then becomes a priority to optimize CT acquisition protocols in order to minimize the delivered dose to the patient. Over the past few years, CT advances have been developing at a rapid pace. Since 2009, new iterative image reconstruction techniques, called statistical iterative reconstructions, have been introduced in order to decrease patient exposure and improve image quality.¦The goal of the present work was to determine the potential of statistical iterative reconstructions to reduce dose as much as possible without compromising image quality and maintain diagnosis of children and young adult examinations.¦The optimization step requires the evaluation of the delivered dose and image quality useful to perform diagnosis. While the dose is estimated using CT indices (CTDIV0| and DLP), the particularity of this research was to use two radically different approaches to evaluate image quality. The first approach, called the "physical approach", computed physical metrics (SD, MTF, NPS, etc.) measured on phantoms in well-known conditions. Although this technique has some limitations because it does not take radiologist perspective into account, it enables the physical characterization of image properties in a simple and timely way. The second approach, called the "clinical approach", was based on the evaluation of anatomical structures (diagnostic criteria) present on patient images. Radiologists, involved in the assessment step, were asked to score image quality of structures for diagnostic purposes using a simple rating scale. This approach is relatively complicated to implement and also time-consuming. Nevertheless, it has the advantage of being very close to the practice of radiologists and is considered as a reference method.¦Primarily, this work revealed that the statistical iterative reconstructions studied in clinic (ASIR? and VECO have a strong potential to reduce CT dose (up to -90%). However, by their mechanisms, they lead to a modification of the image appearance with a change in image texture which may then effect the quality of the diagnosis. By comparing the results of the "clinical" and "physical" approach, it was showed that a change in texture is related to a modification of the noise spectrum bandwidth. The NPS analysis makes possible to anticipate or avoid a decrease in image quality. This project demonstrated that integrating these new statistical iterative reconstruction techniques can be complex and cannot be made on the basis of protocols using conventional reconstructions. The conclusions of this work and the image quality tools developed will be able to guide future studies in the field of image quality as texture analysis or model observers dedicated to CT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Le but de cette étude est d'évaluer la faisabilité et l'efficacité d'un traitement des carcinomes pharyngo-laryngés avancés par combinaison de chimiothérapie intensive associé à une radiothérapie accélérée. Vingt-trois patients ont été inclus (age médian 54 ans, entre 35 et 70 ans). Les localisations tumorales étaient l'hypopharynx (n=7), base de langue (n=10), nasopharynx (n=2) ou l'oesophage proximal (n.1), ou sans porte d'entrée (n=3). Le traitement comprend trois cycles de chimiothérapie (cisplatin 100mg/m2 à J1 ; 5-FU 1000mg/m2 par jour pendant 5 jours en perfusion continue, précédé par de l'amifostine 910mg/m2 ; répété toutes les trois semaines). La radiothérapie concomitante, accélérée (dose totale de 70Gy en 6 semaines) a été débuté au premier jour du deuxième cycle de chimiothérapie. Vingt et un patients ont pu achever la radiothérapie. Dix-huit patients étaient en rémission complète à la fin du traitement. Avec un suivi médian de 45 mois, le taux de survie globale atteint 56% (95% Cl, 32-79%). Le contrôle loco-régional était de 71% (95% CI, 52-91%). La toxicité associée au traitement consistait en une insuffisance rénale réversible (≥grade II) chez 9 patients (43%) et une agranulocytose fébrile chez 9 patients (43%). Tous les patients ont présenté une mucite modérée à sévère (grade II/III) et 19 patients ont montré une toxicité cutanée de grade III. En conclusion, le traitement combiné de radiothérapie accélérée avec une chimiothérapie concomitante à base de Cisplatin/5-FU full-dose avec amifostine est faisable. La toxicité est importante mais reste maîtrisable dans le cadre d'un centre multidisciplinaire. Le taux de survie globale à 4 ans est prometteur, la recherche en vue de traitements moins toxiques doit se poursuivre. Abstract The purpose of this study was to evaluate the feasibility and efficacy of a treatment concept combining three cycles of full-dose chemotherapy (CT) with concomitant accelerated uninterrupted radiotherapy (RI). Twenty- three patients (median age: 54 years, range: 35-70) with locally advanced squamous cell carcinoma of the head and neck (SCCHN) were included. The primary tumor involved the hypopharynx (n=7), base of the tongue (n=10), nasopharynx (n=2) or upper esophagus (n=1) or its location was unknown (n=3). Treatment consisted of three cycles of chemotherapy (cisplatin 100 mg/m2 on day 1; 5-FU 1,000 mg/m2 per day for 5 days as a continuous infusion, preceded by amifostine 910 mg/m2). repeated every 3 weeks. Uninterrupted concomitant boost-accelerated RI (total dose of 70 Gy in 6 weeks) started together on day 1 of the second cycle. All but two patients received the full course of RT. Eighteen patients achieved complete remission (78%). At a median follow-up of 45 months the overall survival was 56% (95% c.i. 32-79%) and the loco-regional control 71% (95% c.i. 52-91%). Toxicity involved reversible renal insufficiency of grade II in 9 patients (39%) and neutropenic fever in 9 patients (39%). All patients suffered from moderate to severe mucositis (grade HMI), and 19 patients presented cutaneous toxicity grade III. Concomitant boost-accelerated RI combined with concurrent full-dose cisplatin/5-FU chemotherapy and amifostine is feasible with manageable, although substantial, toxicity. The overall survival of 4 years is promising. Newer regimens causing less acute mucosal and skin toxicity are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Antiretroviral therapy (ART) containing tenofovir disoproxil fumarate (TDF) and didanosine (ddI) has been associated with poor immune recovery despite virologic success. This effect might be related to ddI toxicity since ddI exposure is substantially increased by TDF. OBJECTIVE: To analyze whether immune recovery during ART with TDF and ddI is ddI-dose dependent. DESIGN AND METHODS: A retrospective longitudinal analysis of immune recovery measured by the CD4 T-cell slope in 614 patients treated with ART containing TDF with or without ddI. Patients were stratified according to the tertiles of their weight-adjusted ddI dose: low dose (< 3.3 mg/kg), intermediate dose (3.3-4.1 mg/kg) and high dose (> 4.1 mg/kg). Cofactors modifying the degree of immune recovery after starting TDF-containing ART were identified by univariable and multivariable linear regression analyses. RESULTS: CD4 T-cell slopes were comparable between patients treated with TDF and a weight-adjusted ddI-dose of < 4.1 mg/kg per day (n = 143) versus TDF-without-ddI (n = 393). In the multivariable model the slopes differed by -13 CD4 T cells/mul per year [95% confidence interval (CI), -42 to 17; P = 0.40]. In contrast, patients treated with TDF and a higher ddI dose (> 4.1 mg/kg per day, n = 78) experienced a significantly impaired immune recovery (-47 CD4 T cells/microl per year; 95% CI, -82 to -12; P = 0.009). The virologic response was comparable between the different treatment groups. CONCLUSIONS: Immune recovery is impaired, when high doses of ddI (> 4.1 mg/kg) are given in combination with TDF. If the dose of ddI is adjusted to less than 4.1 mg/kg per day, immune recovery is similar to other TDF-containing ART regimen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: We report the impact of canakinumab, a fully human anti-interleukin-1β monoclonal antibody, on inflammation and health-related quality of life (HRQoL) in patients with difficult-to-treat Gouty Arthritis. METHODS: In this eight-week, single-blind, double-dummy, dose-ranging study, patients with acute Gouty Arthritis flares who were unresponsive or intolerant to--or had contraindications for--non-steroidal anti-inflammatory drugs and/or colchicine were randomized to receive a single subcutaneous dose of canakinumab (10, 25, 50, 90, or 150 mg) (N = 143) or an intramuscular dose of triamcinolone acetonide 40 mg (N = 57). Patients assessed pain using a Likert scale, physicians assessed clinical signs of joint inflammation, and HRQoL was measured using the 36-item Short-Form Health Survey (SF-36) (acute version). RESULTS: At baseline, 98% of patients were suffering from moderate-to-extreme pain. The percentage of patients with no or mild pain was numerically greater in most canakinumab groups compared with triamcinolone acetonide from 24 to 72 hours post-dose; the difference was statistically significant for canakinumab 150 mg at these time points (P < 0.05). Treatment with canakinumab 150 mg was associated with statistically significant lower Likert scores for tenderness (odds ratio (OR), 3.2; 95% confidence interval (CI), 1.27 to 7.89; P = 0.014) and swelling (OR, 2.7; 95% CI, 1.09 to 6.50, P = 0.032) at 72 hours compared with triamcinolone acetonide. Median C-reactive protein and serum amyloid A levels were normalized by seven days post-dose in most canakinumab groups, but remained elevated in the triamcinolone acetonide group. Improvements in physical health were observed at seven days post-dose in all treatment groups; increases in scores were highest for canakinumab 150 mg. In this group, the mean SF-36 physical component summary score increased by 12.0 points from baseline to 48.3 at seven days post-dose. SF-36 scores for physical functioning and bodily pain for the canakinumab 150 mg group approached those for the US general population by seven days post-dose and reached norm values by eight weeks post-dose. CONCLUSIONS: Canakinumab 150 mg provided significantly greater and more rapid reduction in pain and signs and symptoms of inflammation compared with triamcinolone acetonide 40 mg. Improvements in HRQoL were seen in both treatment groups with a faster onset with canakinumab 150 mg compared with triamcinolone acetonide 40 mg. TRIAL REGISTRATION: clinicaltrials.gov: NCT00798369.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy with concomitant and adjuvant TMZ is the standard of care for newly diagnosed GBM. MGMT methylation status may be an important determinant of treatment response. This trial, conducted by the RTOG, EORTC, and NCCTG, determined if intensified TMZ improves survival (OS) or progression free survival (PFS) in all patients or specific to MGMT status. Eligibility criteria included age . 18 yrs, KPS ≥ 60, and existence of a tissue block with . 1cm2 tumor for prospective MGMT and retrospective molecular analysis. Patients were randomized to Arm 1: standard TMZ (150-200 mg/m2 x 5 d) or Arm 2: dd TMZ (75-100 mg/m2 x 21 d) q 4 wks for 6-12 cycles. Symptom burden, quality of life (QOL), and neurocognition were prospectively and longitudinally assessed in a patient subset. 833 patients were randomized (1173 registered). Inadequate tissue (n ¼ 144) was the most frequent reason for nonrandomization.No statistical difference was observed between Arms 1 and 2 for median OS (16.6, 14.9 mo, p ¼ 0.63), median PFS (5.5, 6.7 mo, p ¼ 0.06), or methylation status. MGMT methylation was associated with improved OS (21.2, 14 mo, p , 0.0001), PFS (8.7, 5.7 mo, p , 0.0001), and treatment response (p ¼ 0.012). Cox modeling identifiedMGMT status and RPA class as significant predictors of OS; treatment arm and radiation technique (EORTC vs. RTOG) were not. There was increased grade ≥ 3 toxicity in Arm 2 (19%, 27%, p ¼ 0.008), which was mostly lymphopenia and fatigue. This study did not demonstrate improved efficacy for dd TMZ for newly diagnosed GBM regardless of methylation status. However, it confirmed the prognostic significance of MGMT methylation in GBM, demonstrated the feasibility of tumor tissue collection, molecular stratification, and collection of patient outcomes in a large transatlantic intergroup trial, thereby establishing a viable clinical trial paradigm. Support: NCI U10 CA 21661 and U10 CA37422.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is well documented that reducing blood pressure (BP) in hypertensive individuals reduces the risk of cardiovascular (CV) events. Despite this, many patients with hypertension remain untreated or inadequately treated, and fail to reach the recommended BP goals. Suboptimal BP control, whilst arising from multiple causes, is often due to poor patient compliance and/or persistence, and results in a significant health and economic burden on society. The use of fixed-dose combinations (FDCs) for the treatment of hypertension has the potential to increase patient compliance and persistence. When compared with antihypertensive monotherapies, FDCs may also offer equivalent or better efficacy, and the same or improved tolerability. As a result, FDCs have the potential to reduce both the CV event rates and the non-drug healthcare costs associated with hypertension. When FDCs are adopted for the treatment of hypertension, issues relating to copayment, formulary restrictions and therapeutic reference pricing must be addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose/Objective(s): To implement a carotid dose sparing protocol using helical Tomotherapy in T1N0 squamous cell laryngeal carcinoma.Materials/Methods: Between July and August 2010, 7 men with stage T1N0 laryngeal carcinoma were included in this study. Age ranged from 47 - 74 years. Staging included endoscopic examination, CT-scan and MRI when indicated. Planned irradiation dose was 70 Gy in 35 fractions over 7 weeks. A simple treatment planning algorithm for carotid sparing was used: maximum point dose to the carotids 35 Gy, to the spinal cord 30 Gy, and 100% PTV volume to be covered with 95% of the prescribed dose. Carotid volume of interest extended to 1 cm above and below of the PTV. Doses to the carotid arteries, to the critical organs, and to the planned target volume (PTV) with our standard laryngeal irradiation protocol was compared. Daily megavoltage scans were obtained before each fraction. When necessary, the Planned Adaptive software (TomoTherapy Inc., Madison, WI) was used to evaluatethe need for a re-planning, which has never been indicated. Dose data were extracted using the VelocityAI software (Atlanta, GA), and data normalization and dose-volume histogram (DVH) interpolation were realized using the Igor Pro software (Portland, OR).Results:A significant (p\0.05) carotid dose sparing compared to our standard protocol with an average maximum point dose of 38.3 Gy (standard deviation [SD] 4.05 Gy), average mean dose of 18.59 Gy (SD 0.83 Gy) was achieved. In all patients, 95% of the carotid volume received less than 28.4 Gy (SD 0.98 Gy). The average maximum point dose to the spinal cord was 25.8 Gy (SD 3.24 Gy). PTV was fully covered with more than 95% of the prescribed dose for all patients with an average maximum point dose of 74.1 Gy and the absolute maximum dose in a single patient of 75.2 Gy. To date, the clinical outcomes have been excellent. Three patients (42%) developed stage 1 mucositis that was conservatively managed, and all the patients presented a mild to moderate dysphonia. All adverse effects resolved spontaneously in the month following the end of treatment. Early local control rate is 100% considering a 4 - 5 months post treatment follow-up.Conclusions: Helical Tomotherapy allows a clinically significant decrease of carotid irradiation dose compared to standard irradiation protocols with an acceptable spinal cord dose tradeoff. Moreover, this technique allows the PTV to be homogenously covered with a curative irradiation dose. Daily control imaging brings added security margins especially when working with high dose gradients. Further investigations and follow-up are underway to better evaluate the late clinical outcomes especially the local control rate, late laryngeal and vascular toxicity, and expected potential impact on cerebrovascular events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Comparer la qualité d'image entre des protocoles dose-standard avec rétroprojection filtrée et basse-dose avec reconstruction itérative en scanner du rachis cervical. Matériels et méthodes: 40 patients ont été investigués par scanner du rachis cervical et prospectivement randomisés en 2 groupes: dose-standard (120kV, 275mAs) avec rétroprojection filtrée, basse-dose (120kV, 150mAs) avec reconstruction itérative. Mesure du bruit, signal-sur-bruit et contraste-sur-bruit. Analyse semi-quantitative (4 points) par 2 observateurs indépendants des disques, foramens, cordon médullaire, ligaments, parties molles et vertèbres, en C3-C4 et C6-C7. Evaluation semi-quantitative (10 points) de la qualité d'image globale. Les paramètres de dose ont été mesurés. Résultats: Il n'y avait aucune différence significative de bruit, signal-sur-bruit ou contraste-sur-bruit entre les 2 protocoles (p≥0.39). En basse-dose avec reconstruction itérative, la visibilité était significativement meilleure pour les disques, foramens et ligaments (p≤0.05), égale pour le cordon médullaire et moins bonne pour les parties molles et vertèbres (p≤0.02). La qualité d'image globale était meilleure, avec une réduction de dose de 41%. Conclusion: Le scanner du rachis cervical basse-dose avec reconstruction itérative fournit des images égales ou meilleures pour les disques, foramens et ligaments, tout en réduisant la dose d'environ 40%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 46-year-old woman with a severe polyradiculoneuropathy treated with high-dose intravenous immunoglobulin (IVIg) presented an encephalopathy with increased blood flow velocities of the middle cerebral arteries (MCAs) detected by transcranial Doppler (TCD) studies. The similitude between this observation and another case recently reported of a patient suffering from Guillain-Barré syndrome (GBS) and cerebral blood flow abnormalities after IVIg treatment prompted us to investigate the responsibility of the IVIg therapy in the genesis of these blood flow alterations. We studied therefore by TCD 10 consecutive patients who underwent this treatment for different reasons. In 1 case we observed an asymptomatic, spontaneously reversible increase in the blood flow velocities of the MCAs consistent with a vasospasm and occurring 3-10 days after completion of the therapy. Stroke and ischemic encephalopathy have been reported as possible complications of IVIg treatment. In the case under discussion, clinical events appeared shortly after the administration of the IVIg therapy and responded favorably to a treatment with nimodipine. Other etiopathogenic mechanisms, in particular a CNS vasculopathic process related to the GBS itself, have to be considered as well. Further studies, with a larger number of patients, are therefore needed to evaluate the underlying mechanisms of blood flow abnormalities occurring sometimes in GBS patients after IVIg treatment.