993 resultados para Power Doppler ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To describe clinical and ultrasound findings in a patient with infantile systemic hyalinosis (ISH). A 5-month-old boy was evaluated of joint contractures. In addition to clinical and laboratory investigations, an ultrasound of his joints was done and compared to a child with similar age. On examination, a short neck, gingival hyperplasia and papular rash were noted. Joint examination showed painful passive movement, reduced range of motion, and joint contractures in knees, elbows, and small joints of the hands, without any evidence of synovial thickness. Ultrasound of the affected joints showed irregular cortical surface of MCPs and PIP, the presence of osteophytes and bone erosions, increased synovial fluid without evidence of synovial hyperplasia. This is the first report to show evidence of US findings in ISH. Ultrasound findings may help to distinguish ISH from JIA in early stages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of the study was to examine the most adequate cut-off point for median nerve cross-sectional area and additional ultrasound features supporting the diagnosis of carpal tunnel syndrome (CTS). Material and methods Forty wrists from 31 CTS patients and 63 wrists from 37 asymptomatic volunteers were evaluated by ultrasound. All patients were women. The mean age was 49.1 years (range: 29-78) in the symptomatic and 45.1 years (range 24-82) in the asymptomatic group. Median nerve cross-sectional area was obtained using direct (DT) and indirect (IT) techniques. Median nerve echogenicity, mobility, flexor retinaculum measurement and the anteroposterior (AP) carpal tunnel distance were assessed. This study was IRB-approved and all patients gave informed consent prior to examination. Results In CTS the median nerve cross-sectional area was increased compared with the control group. Median nerve cross-sectional area of 10 mm(2) (DT) and 9 mm(2) (IT) had high sensitivity (85% and 88.5%, respectively), specificity (92.1% and 82.5%) and accuracy (89.3% and 82.5%) in the diagnosis of CTS. CTS patients had an increased carpal tunnel AP diameter, flexor retinaculum thickening, reduced median nerve mobility and decreased median nerve echogenicity. Conclusion Ultrasound assists in the diagnosis of CTS using the median nerve diameter cut-off point of 10 mm(2) (DT) and 9 mm(2) (IT) and several additional findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonometry seems to have a future for the evaluation of fracture healing. Ultrasound propagation velocity (USPV) significantly decreases at the same time that bone diameter decreases as healing takes place, thus approaching normal values. In this investigation, both USPV and broadband ultrasound attenuation (BUA) were measured using a model of a transverse mid-diaphyseal osteotomy of sheep tibiae. Twenty-one sheep were operated and divided into three groups of seven, according to the follow-up period of 30, 60, and 90 days, respectively. The progress of healing of the osteotomy was checked with monthly conventional radiographs. The animals were killed at the end of the period of observation of each group, both operated-upon and intact tibiae being resected and submitted to the measurement of underwater transverse and direct contact transverse and longitudinal USPV and BUA at the osteotomy site. The intact left tibia of the 21 animals was used for control, being examined on a symmetrical diaphyseal segment. USPV increased while BUA decreased with the progression of healing, with significant differences between the operated and untouched tibiae and between the periods of observation, for most of the comparisons. There was a strong negative correlation between USPV and BUA. Both USPV and BUA directly reflect and can help predict the healing of fractures, but USPV alone can be used as a fundamental parameter. Ultrasonometry may be of use in clinical application to humans provided adequate adaptations can be developed. (C) 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:444-451, 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral nerves are structures that, when damaged, can result in significant motor and sensory disabilities. Several studies have used therapeutic resources with the aim of promoting early nerve regeneration, such as the use of low-power laser. However, this laser therapy does not represent a consensus regarding the methodology, thus yielding controversial conclusions. The objective of our study was to investigate, by functional evaluation, the comparative effects of low-power laser (660 nm and 830 nm) on sciatic nerve regeneration following crushing injuries. Twenty-seven Wistar rats subjected to sciatic nerve injury were divided into three groups: group sham, consisting of rats undergoing simulated irradiation; a group consisting of rats subjected to gallium-aluminum-arsenide (GaAlAs) laser at 660 nm (10 J/cm(2), 30 mW and 0.06 cm(2) beam), and another one consisting of rats subjected to GaAlAs laser at 830 nm (10 J/cm(2), 30 mW and 0.116 cm(2)). Laser was applied to the lesion for 21 days. A sciatic functional index (SFI) was used for functional evaluation prior to surgery and on days 7, 14, and 21 after surgery. Differences in SFI were found between group 660 nm and the other ones at the 14th day. One can observe that laser application at 660 nm with the parameters and methods utilised was effective in promoting early functional recovery, as indicated by the SFI, over the period evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Experimental study idealized to investigate the mechanical properties of deep flexor tendons of rabbits that underwent the tenotomy followed by tenorrhaphy and early application of therapeutic ultrasound with different intensities, in comparison to tendons submitted to tenorrhaphy only. Material and Method: Forty-four rabbits were divided into four experimental groups according to the ultrasound application. They were all submitted to a section of deep flexor tendon in zone 2 and immobilized with an orthosis maintained throughout the experiment. Group A received ultrasonic treatment with an intensity of 1.4 W/cm(2), group B with 0.6 W/cm(2), both in continuous mode, group C with 0.6 W/cm(2) SATA, in pulsated mode at 50% and group D did not receive any ultrasonic treatment. The ultrasonic frequency employed was 1 MHz. After euthanasia, the tendons were dissected and submitted to the mechanical test of traction and qualitative histological analysis. The evaluated mechanical properties were: maximum force, deformation in maximum force and stiffness. Results: There were no statistically significant differences among the experimental groups. Conclusion: Therapeutic ultrasound did not improve the mechanical properties of the flexor tendons after repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To study the influence of low power GaAsAl laser irradiation on the regeneration of a peripheral nerve, following a controlled crush injury. Material and methods: The right common fibular nerve of 30 Wistar rats was submitted to a crush injury with an adjustable load forceps (5 000 g, 10 minutes of application). The animals were divided into three groups (n=10), according to the postoperative procedure (no irradiation; sham irradiation; effective irradiation). Laser irradiation (830 nm wave-length; 100 mW emission power; continuous mode; 140 J/cm(2)) was started on the first postoperative day and continued over 21 consecutive days. Body mass, time spent on the walking track and functional peroneal index (PFI) were analyzed based on the hind footprints, both preoperatively and on the 21st postoperative day. Results: Walking time and PFI significantly improved in the group that received effective laser irradiation, despite the significant gain in body mass between the pre- and post-operative periods. Conclusion: Low Power GaAsAl laser irradiation, with the parameters used in our study, accelerated and improved fibular nerve regeneration in rats.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: