998 resultados para Poluição Sonora
Resumo:
A descriptive study was developed to monitor air fungal contamination in two elementary schools in Lisbon, Portugal. Eight air samples of 250 litres through impaction method were collected in canteen, library, classrooms and also, outside premises as reference place. Simultaneously, were also monitored environmental parameters, including temperature, and humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726 - 1998. Considering both schools, sixteen different species of fungi in air were identified, being the 2 most commonly isolated Cladosporium sp. (51,1%) and Penicillium sp. (27,5%). Besides these genera Trichoderma, Aspergillus, Alternaria, Chrysonilia, Botritys, Ulocladium, Athrium, Aureobasidium, Phoma, Scedosporium e Geotrichum were also isolated. Regarding yeasts, Candida sp., Cryptococcus sp. and Rhodotorula sp. were isolated. The youngest school, as well canteens in each school, presented the worst results concerning the air fungal contamination, maybe due to the higher number of occupants. There was no significant relationship (p>0,05) between fungal contamination and temperature and humidity.
Resumo:
As salas de aula são locais onde a existência de conforto acústico é essencial, permitindo assim garantir que se estabeleça uma boa comunicação sonora no seu interior. Este trabalho visa a avaliação acústica de salas de aula de um edifício escolar situado no distrito de Lisboa. Os parâmetros acústicos medidos foram, o isolamento sonoro e tempo de reverberação. As medições foram efectuadas através de ensaios acústicos in situ, estes obedeceram a uma metodologia normativa no âmbito da acústica de edifícios. O isolamento sonoro foi medido para as seguintes situações, isolamento sonoro a sons aéreos de fachada, isolamento sonoro a sons aéreos entre compartimentos, foi também medido o isolamento sonoro de pavimentos a sons de percussão. Verificou-se que todos os índices de isolamento sonoro apresentam valores satisfatórios, todos acima dos valores recomendados pela regulamentação aplicável a este tipo de edifícios. A medição do tempo de reverberação foi realizada em seis salas do edifício. O critério de escolha das salas consistiu na diversidade de volumes e nas características interiores, como, diferentes tipos de revestimentos e mobiliários (mesas e cadeiras). Após uma análise aos tempos de reverberação constatou-se que para este edifício apenas uma minoria das salas apresenta valores razoáveis, estes na ordem dos 0,8 segundos, estando as restantes salas com tempos superiores a 2,0 segundos. Durante as medições dos tempos de reverberação realizaram-se avaliações em quatro salas, com a introdução de diferentes materiais de revestimento (lã de rocha e carlite) e alteração do tipo de mobiliário. Verificou-se que em salas com área de absorção sonora menor, após a introdução de diferentes materiais , existe uma maior influência na redução do tempo de reverberação. A avaliação com diferentes tipos de mobiliário, permitiu concluir que a utilização de mobiliário revestido, pode ser uma hipótese a considerar para melhorar a qualidade sonora no interior das salas.
Resumo:
Este trabalho teve como objectivos estudar a relação entre os teores de aerossóis medidos na cidade de Lisboa e as condições meteorológicas registadas. O período de amostragem decorreu entre 20 de Janeiro e 19 de Fevereiro de 2009, a designada “Campanha de Inverno” do Projecto de Investigação “Contaminação da atmosfera urbana de Lisboa por Hidrocarbonetos Aromáticos Policíclico (PAHLis)”. Foram seleccionados dois locais da cidade de Lisboa com diferentes níveis de poluição: Olivais e Avenida da Liberdade. Nestes locais existem também estações da Rede da Qualidade do Ar cujos dados foram usados para completar e validar os dados por nós recolhidos. O étodo usado para a determinação da concentração de PM foi o método de referência (método gravimétrico) referido pelas normas EN 12341:1998 e EN 14907:2005. Em cada local, foram recolhidas partículas em suspensão no ar através de amostradores Gent e High-Vol. O Gent é um amostrador de baixo volume (cerca de 12 L de ar por minuto) que possui duas unidades de filtros de policarbonato de dois tamanhos de poro sendo assim possível a recolha de partículas PM2.5 e PM10-2.5 separadamente. O High-Vol é um equipamento de amostragem de alto volume (cerca de 1 m3 de ar por minuto) e onde foram usados dois filtros de quartzo em cascata para a recolha de partículas PM2.5 e PM10-2.5. Verificou-se que os amostradores não foram totalmente eficazes na separação das partículas, segundo os diâmetros aerodinâmicos pretendidos. Os dados apresentaram alguma discrepância face aos dados obtidos pelos High-Vol e também face aos dados obtidos pelos medidores das estações. Optou-se assim pela utilização dos dados obtidos com o amostrador High-Vol. Verifica-se que a Avenida da Liberdade é dos locais de estudo o mais poluído e que a concentração da fracção fina é mais elevada. Tal facto deve-se provavelmente à intensa circulação automóvel, principal fonte poluidora no local. Para o período em estudo e neste local, foi obtida uma média de 16.5 µg/m3 de PM 10-2.5 e 21.9 µg/m3 de PM 2.5. No mesmo período registou-se nos Olivais uma média de 9.0 µg/m3 para a fracção grosseira e 12.3 µg/m3 para a fracção fina. Os dados meteorológicos foram fornecidos pelas estações meteorológicas localizadas nas imediações dos locais em estudo: estação MeteoPortela e estação do Instituto Dom Luiz. Foram recolhidos e tratados dados de temperatura, precipitação, humidade, velocidade e direcção do vento. Com recurso à análise de componentes principais (PCA) foi possível verificar a relação e influência das condições meteorológicas sobre os teores de partículas. Foi possível a redução das variáveis iniciais tendo-se concluído que a humidade, a percipitação e a velocidade do vento são as condições que maior influência têm sobre as partículas. Um aumento destas variáveis provoca uma diminuição global do teor das partículas. Para uma clara definição de um modelo PCA para estes dados, os estudos deverão se prolongados no tempo.
Resumo:
Desde que a bicicleta foi aperfeiçoada, em meados do séc. XIX, por todo o mundo existem pessoas que a utilizam. Uma grande parte utiliza-a para lazer e desporto, mas em muitos países a Bicicleta é um importante meio de transporte. Criar condições de conforto e segurança nas nossas cidades é imperativo para que a bicicleta possa ser utilizada numa base diária, num mundo em radical mudança, nomeadamente ao nível climático e de eminente esgotamento dos recursos energéticos tradicionais, como o petróleo ou o carvão, base primária para o actual funcionamento das sociedades em termos de mobilidade. Na cidade de Lisboa, ao longo de décadas foram-se criando mitos acerca da “impossibilidade” da utilização da bicicleta como meio de transporte. Pretende este trabalho analisar de um ponto de vista científico esses mesmos mitos, comprovando-os ou desmistificando-os.
Resumo:
Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.
Resumo:
In this study, the results of chemical concentrations inside and outside of a Lisbon (Portugal) traffic tunnel were compared, during one week. They were obtained by Instrumental Neutron Activation Analysis (INAA). The tunnel values largely exceed the Air Ambient legislated values and the Pearson Correlations Coefficients point out to soil re-suspension/dispersed road dust (As, Ce, Eu, Hf, Fe, Mo, Sc, Zn), traffic-markers (Ba, Cr), tire wear (Cr, Zn), break wear (Fe, Zn, Ba, Cu, Sb), exhaust and motor oil (Zn) and sea-spray (Br, Na). On all days these elements inside the tunnel were more enriched than outside; significant statistical differences were found for Co (p=0.005), Br (p=0.008), Zn (p=0.01) and Sb (p=0.005), while enrichment factors of As and Sc are statistically identical. The highest values were found for As, Br, Zn and Sb, for both inside and outside the tunnel.
Resumo:
Total particulate matter (TPM) was passively collected inside two classrooms of each of five elementary schools in Lisbon, Portugal. TPM was collected in polycarbonate filters with a 47 mm diameter, placed inside of uncovered plastic petri dishes. The sampling period was from 19 May to 22 June 2009 (35 days exposure) and the collected TPM masses varied between 0.2 mg and 0.8 mg. The major elements were Ca, Fe, Na, K, and Zn at μg level, while others were at ng level. Pearson′s correlation coefficients above 0.75 (a high degree of correlation) were found between several elements. Soil-related, traffic soil re-suspension and anthropogenic emission sources could be identified. Blackboard chalk was also identified through Ca large presence. Some of the determined chemical elements are potential carcinogenic. Quality control of the results showed good agreement as confirmed by the application of u-score test.
Resumo:
Nowadays, most individuals spend about 80% of their time indoor and, consequently, the exposure to the indoor environment becomes more relevant than to the outdoor one. Children spend most of their time at home and at school and evaluations of their indoor environment are important for the time-weighted exposure. Due to their airways still in development, children are a sensitive group with higher risk than adults. Larger impact in health and educational performance of children demand indoor air quality studies of schools. The aim of this study was to assess the children exposure to bioaerosols. A methodology based upon passive sampling was applied to evaluate fungi, bacteria and pollens; its procedures and applicability was optimized. An indoor air study by passive sampling represents an easier and cheaper method when comparing with the use of automatic active samplers. Furthermore, it is possible to achieve important quality information without interfering in the classroom activities. The study was conducted in three schools, representative of different environments in the Lisbon urban area, at three different periods of the year to obtain a seasonal variation, to estimate the variability through the city and to understand the underneath causes. Fungi and bacteria were collected indoor and outdoor of the classrooms to determine the indoor/outdoor ratios and to assess the level of outdoor contamination upon the indoor environment. The children's exposure to pollen grains inside the classrooms was also assessed.
Resumo:
Clean air is a basic requirement of life. The Indoor Air Quality (IAQ) has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people tend to spend more time indoors than outdoors. The quality of air inside homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being. People can be exposed to contaminants by inhalation, ingestion and dermal contact. In the past, scientists have paid much attention to the study of exposure to outdoor air contaminants, because they have realised the seriousness of outdoor air pollution problems. However, each indoor microenvironment has unique characteristics, determined by the local outdoor air, specific building characteristics and indoor activities. Indeed, hazardous substances are emitted from buildings, construction materials and indoor equipment or due to human activities indoors.
Resumo:
Apresenta-se uma atualização bibliográfica com o objetivo de relatar a origem e os riscos à saúde pública das dioxinas e furanos e possibilitar o conhecimento de algumas áreas de pesquisa sobre esses compostos. Foram selecionadas 16 referências bibliográficas, cobrindo aproximadamente doze anos (1986 a 1997). Pela análise feita concluiu-se que: a) Esses compostos são de origem não natural, considerados altamente tóxicos, extremamente persistentes, tendo sido detectados em todas as matrizes ambientais como: solo, sedimentos, ar, água, animais e vegetais; b) emissões desses compostos para a atmosfera ocorrem principalmente nos processos de combustão; c) dispersão atmosférica, deposição e subseqüente acumulação na cadeia alimentar têm sido a principal rota de exposição da população em geral; d) devido à natureza lipofílica e persistência, estes se acumulam em tecidos gordurosos, sendo os alimentos de origem animal os que apresentaram maiores concentrações; e) no Brasil, os poucos estudos realizados, com medidas de concentrações desses compostos no meio ambiente, apresentaram alguns níveis comparáveis aos da Alemanha. Recomenda-se a continuidade de pesquisas no Brasil, sobre esses compostos, em especial sua acumulação em alimentos e no tecido humano.
Resumo:
O crescente número de automóveis nas ruas das grandes cidades, assim como o crescente número de transportes urbanos para atender o crescimento das populações, veio fazer com que as cidades cada vez mais fiquem mais congestionadas e mais propícias para acidentes envolvendo viaturas e peões. Devido a isso, foram criados sistemas de controlo de tráfego capazes de melhorar o tráfego urbano nas cidades, sem deixar de lado as preocupações com os peões e nem com as emissões de poluentes para o ar. Baseado nesse cenário, este trabalho tem como objetivo abordar as possíveis soluções existentes no mercado para melhorar o fluxo das viaturas, principalmente dos transportes colectivos, com prioridades para viaturas de emergências e autocarros, assim como, as passagens de peões, e sistemas de mobilidade urbana. Desempenho do transporte público pode ser melhorado através de um melhor controlo e gerenciamento de tráfego em geral. Nos testes realizados em campo: foi medida a velocidade de viagem do autocarro no cruzamento fixo (Praça de Espanha), e correlacionando-os com intervalos do ciclo dos semáforos para este cruzamento. A flexibilidade do controlador actuando, com o auxílio de detectores de veículos, sendo capaz de variar os intervalos dentro do ciclo, bem como o volume de carros e de prestações em velocidade de viagem do autocarro. Resultados mostram que, durante o período em estudo, os benefícios de velocidade da viagem do autocarro, seria possível, através de um verdadeiro controlo de tempo feedback de cooperação entre as áreas urbanas de controlo de tráfego (Gertrude) e do sistema de localização de veículos de transportes públicos (SAEIP). Ao longo prazo, sugerimos a implantação de um sistema integrado. Fazendo com que o volume no carro seja reduzido. Este efeito leva também, a um aumento da velocidade comercial do autocarro urbano, da mesma forma como foi proposto em nossa experiência.
Resumo:
OBJETIVO: Avaliar a associação do fumo passivo com morbidade respiratória em crianças abaixo de 5 anos de idade. MÉTODOS: Estudo transversal incluindo 1.104 crianças abaixo de 5 anos de idade residentes na cidade de Fortaleza, Ceará. Por meio de um questionário com os pais das crianças, foram obtidas informações sobre sintomas e doenças respiratórias, história familiar de morbidade respiratória, presença de fumantes nas casas e condições de moradia. RESULTADOS: Foram estudados 546 meninas e 558 meninos. Das 611 crianças fumantes passivas, 82% tinham problemas respiratórios ("odds ratio" = 1,64; IC 95%:1,21-2,20). As queixas respiratórias mais freqüentes foram: chiado no peito ("odds ratio" =1,66; IC 95%: 1,21-2,27), dispnéia ("odds ratio"=1,91; IC 95%:1,36-2,67), tosse e/ou expectoração("odds ratio" =1,58; IC 95%: 1,13-2,84). A chance de apresentar asma, bronquite ou pneumonia foi maior para as crianças fumantes passivas ("odds ratio" =1,60; IC 95%: 1.11-2.31). CONCLUSÕES: Os principais fatores de risco com chance de predizer morbidade respiratória em crianças com idade de 0 a 5 anos foram: crianças que conviviam com mães fumantes, pais fumantes, presença de mofo em casa, historia familiar de asma ou rinite.
Resumo:
As mais diversas actividades humanas ocorrentes na periferia dos edifícios, principalmente nos grandes centros urbanos, e no interior dos próprios edifícios, originam níveis de intensidade sonora que podem ser fontes de elevado incómodo para os seus habitantes. A escolha de soluções construtivas adequadas que visem atenuar os efeitos destas fontes de radiação sonora torna-se desta forma importante para garantir a qualidade habitacional. Com vista à obtenção das exigências de conforto acústico o regulamento dos requisitos acústicos em edifícios estipula um conjunto de parâmetros de desempenho acústico que os elementos constituintes dos edifícios estão obrigados a cumprir. A avaliação destes parâmetros faz-se recorrendo à realização de ensaios acústicos, medições estas que se regem pelas normas da série ISO 140 e da série ISO 717. No presente trabalho descreveu-se resumidamente todas as especificações e procedimentos essenciais que as referidas normas de medição de isolamento sonoro definem. Foi ainda efectuada a avaliação in situ do isolamento a sons aéreos de dois elementos que separam compartimentos de diferentes fogos, de quatro elementos de fachada assim como o isolamento a sons de percussão de um pavimento pertencente a um edifício multifamiliar com uso unicamente habitacional, que serviu como caso de estudo. Posteriormente e através da análise objectiva dos resultados dos ensaios efectuou-se a verificação da conformidade dos índices de isolamento sonoro obtidos com os requisitos regulamentares.
Resumo:
Mestrado em Segurança e Higiene no Trabalho.
Resumo:
Nos últimos anos tem vindo a ser discutida a divulgação das informações financeiras necessárias à consecução do objectivo da Contabilidade, ou seja a possibilidade de fornecer informação acrescida de natureza económica, financeira e social aos utilizadores internos e externos da empresa. Há empresas que não consideram necessário relatar as suas acções junto dos diferentes públicos, ou seja separam a empresa do seu meio envolvente, fazendo uma delimitação entre as esferas interna e externa da empresa. Esta perspectiva auto centrada, que elimina a envolvente externa do discurso empresarial a qual considera que alguns resultados são dignos de divulgação contabilística, enquanto outros são irrelevantes e devem ser ignorados tem vindo a ser questionada. Neste sentido existem empresas que passaram a considerar necessário relatar acções junto dos diferentes utilizadores interessados, no entanto quando o fazem, é sem uniformidade. O meio envolvente tem vindo a tornar-se num factor que implica custos, como consequência de requisitos impostos pela regulação governamental sobre o controlo da poluição e devido a uma maior consciencialização do público, que pode afectar a rentabilidade dos negócios enquanto consumidor, empregado ou investidor. O emergir destas exigência baseia-se no pressuposto de que as empresas têm responsabilidades acrescidas, que vão além da obtenção do rendimento financeiro para os accionistas. Verificando-se nos últimos anos um aumento do número de empresas que acedem aos mercados de capitais, gerou-se uma necessidade crescente de uma maior divulgação de informação por parte das empresas, com reflexos no relato financeiro empresarial, motivo pelo qual vários autores e organismos também têm dado atenção à problemática da divulgação voluntária da informação por parte das empresas. Neste contexto, O FASB, elaborou um relatório que identifica quais os benefícios e desvantagens da divulgação voluntária de informação e apresenta algumas recomendações e conclusões para as empresas, enfatizando os efeitos da divulgação voluntária de informação no custo de capital, nas relações com os investidores, e no mercado de capitais. Outros autores e organismos também têm dado atenção à problemática da divulgação voluntária da informação por parte das empresas: Para Boeso (2002) era importante que os organismos de harmonização contabilística emitissem recomendações adicionais no sentido de uma maior harmonização, sem se centrarem apenas nos investidores mas também nos outros utilizadores da informação; Globerman e Singleton (2000) elaboraram um estudo com a finalidade de fornecer a evidência de que as empresas Japonesas se tornariam mais similares ao logo do tempo, na divulgação do relato voluntário da informação contabilística, concluindo que a informação procurada pelos utilizadores é muito diversificada sendo difícil a existência de um padrão comum de divulgação; Colares e Ponte (2003) demonstraram que as empresas ainda têm muito que evoluir no sentido da transparência e qualidade da divulgação voluntária de informação.