999 resultados para Parallel imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Contrast-enhanced ultrasonography (CEUS) is a novel imaging technique that is safe and applicable on the bedside. Recent developments seem to enable CEUS to quantify organ perfusion. We performed an exploratory study to determine the ability of CEUS to detect changes in renal perfusion and to correlate them with effective renal plasma flow. METHODS: CEUS with destruction-refilling sequences was studied in 10 healthy subjects, at baseline and during infusion of angiotensin II (AngII) at low (1 ng/kg/min) and high dose (3 ng/kg/min) and 1 h after oral captopril (50 mg). Perfusion index (PI) was obtained and compared with the effective renal plasma flow (ERPF) obtained by parallel para-aminohippurate (PAH) clearance. RESULTS: Median PI decreased from 188.6 (baseline) to 100.4 with low-dose AngII (-47%; P < 0.02) and to 66.1 with high-dose AngII (-65%; P < 0.01) but increased to 254.7 with captopril (+35%; P > 0.2). These changes parallelled those observed with ERPF, which changed from a median of 672.1 mL/min (baseline) to 572.3 (low-dose AngII, -15%, P < 0.05) and to 427.2 (high-dose AngII, -36%, P < 0.001) and finally 697.1 (captopril, +4%, P < 0.02). CONCLUSIONS: This study demonstrates that CEUS is able to detect changes in human renal cortical microcirculation as induced by AngII infusion and/or captopril administration. The changes in perfusion indices parallel those in ERPF as obtained by PAH clearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the feasibility, determine the optimal b-value, and assess the utility of 3-T diffusion-weighted MR imaging (DWI) of the spine in differentiating benign from pathologic vertebral compression fractures.Methods and Materials: Twenty patients with 38 vertebral compression fractures (24 benign, 14 pathologic) and 20 controls (total: 23 men, 17 women, mean age 56.2years) were included from December 2010 to May 2011 in this IRB-approved prospective study. MR imaging of the spine was performed on a 3-T unit with T1-w, fat-suppressed T2-w, gadolinium-enhanced fat-suppressed T1-w and zoomed-EPI (2D RF excitation pulse combined with reduced field-of-view single-shot echo-planar readout) diffusion-w (b-values: 0, 300, 500 and 700s/mm2) sequences. Two radiologists independently assessed zoomed-EPI image quality in random order using a 4-point scale: 1=excellent to 4=poor. They subsequently measured apparent diffusion coefficients (ADCs) in normal vertebral bodies and compression fractures, in consensus.Results: Lower b-values correlated with better image quality scores, with significant differences between b=300 (mean±SD=2.6±0.8), b=500 (3.0±0.7) and b=700 (3.6±0.6) (all p<0.001). Mean ADCs of normal vertebral bodies (n=162) were 0.23, 0.17 and 0.11×10-3mm2/s with b=300, 500 and 700s/mm2, respectively. In contrast, mean ADCs were 0.89, 0.70 and 0.59×10-3mm2/s for benign vertebral compression fractures and 0.79, 0.66 and 0.51×10-3mm2/s for pathologic fractures with b=300, 500 and 700s/mm2, respectively. No significant difference was found between ADCs of benign and pathologic fractures.Conclusion: 3-T DWI of the spine is feasible and lower b-values (300s/mm2) are recommended. However, our preliminary results show no advantage of DWI in differentiating benign from pathologic vertebral compression fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary magnetic resonance angiography (MRA) is a technique aimed at establishing a noninvasive test for the assessment of significant coronary stenoses. There are certain boundary conditions that have hampered the clinical success of coronary MRA and coronary vessel wall imaging. Recent advances in hardware and software allow for consistent visualization of the proximal and mid portions of the native coronary arteries. Current research focuses on the use of intravascular MR contrast agents and black blood coronary angiography. One common goal is to create a noninvasive test which might allow for screening for major proximal and mid coronary artery disease. These novel approaches will represent a major step forward in diagnostic cardiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy metabolism measurements in spinal cord tumors, as well as in osseous spinal tumors/metastasis in vivo, are rarely performed only with molecular imaging (MI) by positron emission tomography (PET). This imaging modality developed from a small number of basic clinical science investigations followed by subsequent work that influenced and enhanced the research of others. Apart from precise anatomical localization by coregistration of morphological imaging and quantification, the most intriguing advantage of this imaging is the opportunity to investigate the time course (dynamics) of disease-specific molecular events in the intact organism. Most importantly, MI represents one of the key technologies in translational molecular neuroscience research, helping to develop experimental protocols that may later be applied to human patients. PET may help monitor a patient at the vertebral level after surgery and during adjuvant treatment for recurrent or progressive disease. Common clinical indications for MI of primary or secondary CNS spinal tumors are: (i) tumor diagnosis, (ii) identification of the metabolically active tumor compartments (differentiation of viable tumor tissue from necrosis) and (iii) prediction of treatment response by measurement of tumor perfusion or ischemia. While spinal PET has been used under specific circumstances, a question remains as to whether the magnitude of biochemical alterations observed by MI in CNS tumors in general (specifically spinal tumors) can reveal any prognostic value with respect to survival. MI may be able to better identify early disease and to differentiate benign from malignant lesions than more traditional methods. Moreover, an adequate identification of treatment effectiveness may influence patient management. MI probes could be developed to image the function of targets without disturbing them or as treatment to modify the target's function. MI therefore closes the gap between in vitro and in vivo integrative biology of disease. At the spinal level, MI may help to detect progression or recurrence of metastatic disease after surgical treatment. In cases of nonsurgical treatments such as chemo-, hormone- or radiotherapy, it may better assess biological efficiency than conventional imaging modalities coupled with blood tumor markers. In fact, PET provides a unique possibility to correlate topography and specific metabolic activity, but it requires additional clinical and experimental experience and research to find new indications for primary or secondary spinal tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Puropse/Aim: To learn about the developement of post mortem CT angiography, its indications, benefits, pitfalls and practical application. Content Organization: A. Developement of post mortem CT angiography B. Technical prerequisites C. Practical application of post mortem CT angiography (preparation of the body, injection of contrast agent, examination protocol) D. Indications and benefits (including a comparison with conventional autopsy) E. Interpretation of imaging data (with case demonstrations) F. Artifacts, pitfalls and limitations G. Current and potential future use. Summary: This exhibit demonstrates the developement, application and interpretation of post mortem CT angiography. Teaching points: 1. post mortem CT angiography is feasible and useful for identification of the cause of death 2. depending on the indication it can be superior to autopsy 3. limitations and artifacts need to be known for interpreta

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The functionality of adult neocortical circuits can be altered by novel experiences or learning. This functional plasticity appears to rely on changes in the strength of neuronal connections that were established during development. Here we will describe some of our studies in which we have addressed whether structural changes, including the remodeling of axons and dendrites with synapse formation and elimination, could underlie experience-dependent plasticity in the adult neocortex. Using 2-photon laser-scanning microscopes and transgenic mice expressing GFP in a subset of pyramidal cells, we have observed that a small subset of dendritic spines continuously appear and disappear on a daily basis, whereas the majority of spines persists for months. Axonal boutons from different neuronal classes displayed similar behavior, although the extent of remodeling varied. Under baseline conditions, new spines in the barrel cortex were mostly transient and rarely survived for more than a week. However, when every other whisker was trimmed, the generation and loss of persistent spines was enhanced. Ultrastructural reconstruction of previously imaged spines and boutons showed that new spines slowly form synapses. New spines persisting for a few days always had synapses, whereas very young spines often lacked synapses. New synapses were predominantly found on large, multi-synapse boutons, suggesting that spine growth is followed by synapse formation, preferentially on existing boutons. Altogether our data indicate that novel sensory experience drives the stabilization of new spines on subclasses of cortical neurons and promotes the formation of new synapses. These synaptic changes likely underlie experience-dependent functional remodeling of specific neocortical circuits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Intravoxel incoherent motion (IVIM) imaging is an MRI perfusion technique that uses a diffusion-weighted sequence with multiple b values and a bi-compartmental signal model to measure the so-called pseudo-diffusion of blood caused by its passage through the microvascular network. The goal of the current study was to assess the feasibility of IVIM perfusion fraction imaging in patients with acute stroke. METHODS: Images were collected in 17 patients with acute stroke. Exclusion criteria were onset of symptoms to imaging >5 days, hemorrhagic transformation, infratentorial lesions, small lesions <0.5 cm in minimal diameter and hemodynamic instability. IVIM imaging was performed at 3 T, using a standard spin-echo Stejskal-Tanner pulsed gradients diffusion-weighted sequence, using 16 b values from 0 to 900 s/mm(2). Image quality was assessed by two radiologists, and quantitative analysis was performed in regions of interest placed in the stroke area, defined by thresholding the apparent diffusion coefficient maps, as well as in the contralateral region. RESULTS: IVIM perfusion fraction maps showed an area of decreased perfusion fraction f in the region of decreased apparent diffusion coefficient. Quantitative analysis showed a statistically significant decrease in both IVIM perfusion fraction f (0.026 ± 0.019 vs. 0.056 ± 0.025, p = 2.2 · 10(-6)) and diffusion coefficient D compared with the contralateral side (3.9 ± 0.79 · 10(-4) vs. 7.5 ± 0.86 · 10(-4) mm(2)/s, p = 1.3 · 10(-20)). CONCLUSION: IVIM perfusion fraction imaging is feasible in acute stroke. IVIM perfusion fraction is significantly reduced in the visible infarct. Further studies should evaluate the potential for IVIM to predict clinical outcome and treatment response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image quality in magnetic resonance imaging (MRI) is considerably affected by motion. Therefore, motion is one of the most common sources of artifacts in contemporary cardiovascular MRI. Such artifacts in turn may easily lead to misinterpretations in the images and a subsequent loss in diagnostic quality. Hence, there is considerable research interest in strategies that help to overcome these limitations at minimal cost in time, spatial resolution, temporal resolution, and signal-to-noise ratio. This review summarizes and discusses the three principal sources of motion: the beating heart, the breathing lungs, and bulk patient movement. This is followed by a comprehensive overview of commonly used compensation strategies for these different types of motion. Finally, a summary and an outlook are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to illustrate the chest radiographs (CR) and CT imaging features and sequential findings of cavitary necrosis in complicated childhood pneumonia. Among 30 children admitted in the Pediatric Intensive Care Unit for persistent or progressive pneumonia, respiratory distress or sepsis despite adequate antibiotic therapy, a study group of 9 children (5 girls and 4 boys; mean age 4 years) who had the radiographic features and CT criteria for cavitary necrosis complicated pneumonia was identified. The pathogens identified were Streptococcus pneumoniae( n=4), Aspergillus( n=2), Legionella( n=1), and Staphylococcus aureus( n=1). Sequential CR and CT scans were retrospectively reviewed. Follow-up CR and CT were evaluated for persistent abnormalities. Chest radiographs showed consolidations in 8 of the 9 patients. On CT examination, cavitary necrosis was localized to 1 lobe in 2 patients and 7 patients showed multilobar or bilateral areas of cavitary necrosis. In 3 patients of 9, the cavitary necrosis was initially shown on CT and visualization by CR was delayed by a time span varying from 5 to 9 days. In all patients with cavities, a mean number of five cavities were seen on antero-posterior CR, contrasting with the multiple cavities seen on CT. Parapneumonic effusions were shown by CR in 3 patients and in 5 patients by CT. Bronchopleural fistulae were demonstrated by CT alone ( n=3). No purulent pericarditis was demonstrated. The CT scan displayed persistent residual pneumatoceles of the left lower lobe in 2 patients. Computed tomography is able to define a more specific pattern of abnormalities than conventional CR in children with necrotizing pneumonia and allows an earlier diagnosis of this rapidly progressing condition. Lung necrosis and cavitation may also be associated with Aspergillus or Legionella pneumonia in the pediatric population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary MR imaging is a promising noninvasive technique for the combined assessment of coronary artery anatomy and function. Anomalous coronary arteries and aneurysms can reliably be assessed in clinical practice using coronary MR imaging and the presence of significant left main or proximal multivessel coronary artery disease detected. Technical challenges that need to be addressed are further improvements in motion suppression and abbreviated scanning times aimed at improving spatial resolution and patient comfort. The development of new and specific contrast agents, high-field MR imaging with improved spatial resolution, and continued progress in MR imaging methods development will undoubtedly lead to further progress toward the noninvasive and comprehensive assessment of coronary atherosclerotic disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, modern techniques of medical imaging such as MDCT (multidetector-computed tomography) and MRI (magnetic resonance imaging) have pioneered post mortem (pm) investigations, especially in forensic medicine. Particularly pm angiography permits investigating the vascular system in a way which is not possible by performing only conventional autopsy. Beside these radiological methods, other modem visualizing techniques like the three dimensional (3D) surface scan have been implemented in order perform reconstructions of complex cases. By the use of pm imaging techniques, more objective and accurate documentations can be realized that permit an increase of quality in forensic investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El procés de fusió de dues o més imatges de la mateixa escena en una d'única i més gran és conegut com a Image Mosaicing. Un cop finalitzat el procés de construcció d'un mosaic, els límits entre les imatges són habitualment visibles, degut a imprecisions en els registres fotomètric i geomètric. L'Image Blending és l'etapa del procediment de mosaicing a la que aquests artefactes són minimitzats o suprimits. Existeixen diverses metodologies a la literatura que tracten aquests problemes, però la majoria es troben orientades a la creació de panorames terrestres, imatges artístiques d'alta resolució o altres aplicacions a les quals el posicionament de la càmera o l'adquisició de les imatges no són etapes rellevants. El treball amb imatges subaquàtiques presenta desafiaments importants, degut a la presència d'scattering (reflexions de partícules en suspensió) i atenuació de la llum i a condicions físiques extremes a milers de metres de profunditat, amb control limitat dels sistemes d'adquisició i la utilització de tecnologia d'alt cost. Imatges amb il·luminació artificial similar, sense llum global com la oferta pel sol, han de ser unides sense mostrar una unió perceptible. Les imatges adquirides a gran profunditat presenten una qualitat altament depenent de la profunditat, i la seva degradació amb aquest factor és molt rellevant. El principal objectiu del treball és presentar dels principals problemes de la imatge subaquàtica, seleccionar les estratègies més adequades i tractar tota la seqüència adquisició-procesament-visualització del procés. Els resultats obtinguts demostren que la solució desenvolupada, basada en una Estratègia de Selecció de Límit Òptim, Fusió en el Domini del Gradient a les regions comunes i Emfatització Adaptativa d'Imatges amb baix nivell de detall permet obtenir uns resultats amb una alta qualitat. També s'ha proposat una estratègia, amb possibilitat d'implementació paral·lela, que permet processar mosaics de kilòmetres d'extensió amb resolució de centímetres per píxel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD). Materials and Methods. Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61 ± 10 years) were studied on a commercial 3.0 Tesla (T) whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands). T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI) was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd) (0.1 mmol/kg Gd-DTPA). Results. LGE was seen in none of the healthy subjects, however in all of the CAD patients. In CAD patients, fifty-six of 62 (90.3%) segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast. At time-interval 2, 34 of 42 (81.0%) and at time-interval 3, 29 of 39 evaluable segments (74.4%) were enhanced. Conclusion. In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects. In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30-45 minutes after administration of the contrast agent.