967 resultados para Odd third order intensity parameters
Resumo:
Mode of access: Internet.
Resumo:
Includes index.
Resumo:
At head of title: No. 6007.
Resumo:
We present a group theoretical analysis of several classes of organic superconductor. We predict that highly frustrated organic superconductors, such as K-(ET)(2)Cu-2(CN)(3) (where ET is BEDT-TTF, bis(ethylenedithio) tetrathiafulvalene) and beta'-[Pd(dmit)(2)](2)X, undergo two superconducting phase transitions, the first from the normal state to a d-wave superconductor and the second to a d + id state. We show that the monoclinic distortion of K-(ET)(2)Cu(NCS)(2) means that the symmetry of its superconducting order parameter is different from that of orthorhombic-K-(ET)(2)Cu[N(CN)(2)] Br. We propose that beta'' and theta phase organic superconductors have d(xy) + s order parameters.
Resumo:
PURPOSE. To establish the optimal flash settings for retinal vessel oxygen saturation parameters using dual-wavelength imaging in a multiethnic group. METHODS. Twelve healthy young subjects (mean age 32 years [SD 7]; three Mediterranean, two South Asian, and seven Caucasian individuals) underwent retinal vessel oxygen saturation measurements using dual-wavelength oximetry, noncontact tonometry, and manual sphygmomanometry. In order to evaluate the impact of flash intensity, we obtained three images (fundus camera angle 30°, ONH centered) per flash setting. Flash settings of the fundus camera were increased in steps of 2 (initial setting of 6 and the final of 22), which reflect logarithmic increasing intensities from 13.5 to 214 Watt seconds (Ws). RESULTS. Flash settings below 27 Ws were too low to obtain saturation measurements, whereas flash settings of more than 214 Ws resulted in overexposed images. Retinal arteriolar and venular oxygen saturation was comparable at flash settings of 27 to 76 Ws (arterioles' range: 85%-92%; venules' range: 45%-53%). Higher flash settings lead to increased saturation measurements in both retinal arterioles (up to 110%) and venules (up to 92%), with a more pronounced increase in venules. CONCLUSIONS. Flash intensity has a significant impact on retinal vessel oxygen saturation measurements using dual-wavelength retinal oximetry. High flash intensities lead to supranormal oxygen saturation measurements with a magnified effect in retinal venules compared with arteries. In addition to even retinal illumination, the correct flash setting is of paramount importance for clinical acquisition of images in retinal oximetry. We recommend flash settings between 27 to 76 Ws. © 2013 The Association for Research in Vision and Ophthalmology, Inc.
Resumo:
Physical exercise programmes are routinely prescribed in clinical practice to treat impairments, improve activity and participation in daily life because of their known physiological, health and psychological benefits (RCP, 2009). Progressive resistance exercise is a type of exercise prescribed specifically to improve skeletal muscle strength (Latham et al., 2004). The effectiveness of progressive resistance exercise varies considerably between studies and populations. This thesis focuses on how training parameters influence the delivery of progressive resistance exercise. In order to appropriately evaluate the influence of training parameters, this thesis argues the need to record training performance and the total work completed by participants as prescribed by training protocols. In the first study, participants were taken through a series of protocols differentiated by the intensity and volume of training. Training intensity was defined as a proportion of the mean peak torque achieved during maximal voluntary contractions and was set at 80% and 40% respectively of the MVC mean peak torque. Training volume was defined as the total external work achieved over the training period. Measures of training performance were developed to accurately report the intensity, repetitions and work completed during the training period. A second study evaluated training performance of the training protocols over repeated sessions. These protocols were then applied to 3 stroke survivors. Study 1 found sedentary participants could achieve a differentiated training intensity. Participants completing the high and low intensity protocols trained at 80% and 40% respectively of the MVC mean peak torque. The total work achieved in the high intensity low repetition protocol was lower than the total work achieved in the low intensity high repetition protocol. With repeated practice, study 2 found participants were able to improve in their ability to perform manoeuvres as shown by a reduction in the variation of the mean training intensity achieving total work as specified by the protocol to a lower margin of error. When these protocols were applied to 3 stroke survivors, they were able to achieve the specified training intensity but they were not able to achieve the total work as expected for the protocol. This is likely to be due to an inability in achieving a consistent force throughout the contraction. These results demonstrate evaluation of training characteristics and support the need to record and report training performance characteristics during progressive resistance exercise, including the total work achieved, in order to elucidate the influence of training parameters on progressive resistance exercise. The lack of accurate training performance may partly explain the inconsistencies between studies on optimal training parameters for progressive resistance exercise.
Resumo:
In previous papers we describe a model for capacity analysis in CDMA systems using DC-Cell, a GIS based planning tool developed at Universidad Politecnica de Valencia, and MATLAB. We show some initial results of that model, and now, we are exploring different parameters like cell size, proximity between cells, number of cells in the system and “clustering” CDMA in order to improve the planning process for third generation systems. In this paper we show the results for variations of some of these parameters, specifically the cell size and number of cells. In CDMA systems is quite common to suppose only one carrier frequency for capacity estimation, and it is intuitive to think that for more base stations, mean more users. However the multiple access interference problem in CDMA systems could establish a limit for that supposition in a similar way that occurs in FDMA and TDMA systems.
Resumo:
Tsunamis are rare events. However, their impact can be devastating and it may extend to large geographical areas. For low-probability high-impact events like tsunamis, it is crucial to implement all possible actions to mitigate the risk. The tsunami hazard assessment is the result of a scientific process that integrates traditional geological methods, numerical modelling and the analysis of tsunami sources and historical records. For this reason, analysing past events and understanding how they interacted with the land is the only way to inform tsunami source and propagation models, and quantitatively test forecast models like hazard analyses. The primary objective of this thesis is to establish an explicit relationship between the macroscopic intensity, derived from historical descriptions, and the quantitative physical parameters measuring tsunami waves. This is done first by defining an approximate estimation method based on a simplified 1D physical onshore propagation model to convert the available observations into one reference physical metric. Wave height at the coast was chosen as the reference due to its stability and independence of inland effects. This method was then implemented for a set of well-known past events to build a homogeneous dataset with both macroseismic intensity and wave height. By performing an orthogonal regression, a direct and invertible empirical relationship could be established between the two parameters, accounting for their relevant uncertainties. The target relationship is extensively tested and finally applied to the Italian Tsunami Effect Database (ITED), providing a homogeneous estimation of the wave height for all existing tsunami observations in Italy. This provides the opportunity for meaningful comparison for models and simulations, as well as quantitatively testing tsunami hazard models for the Italian coasts and informing tsunami risk management initiatives.
Resumo:
Rapidity-odd directed flow (v1) measurements for charged pions, protons, and antiprotons near midrapidity (y=0) are reported in sNN=7.7, 11.5, 19.6, 27, 39, 62.4, and 200 GeV Au+Au collisions as recorded by the STAR detector at the Relativistic Heavy Ion Collider. At intermediate impact parameters, the proton and net-proton slope parameter dv1/dy|y=0 shows a minimum between 11.5 and 19.6 GeV. In addition, the net-proton dv1/dy|y=0 changes sign twice between 7.7 and 39 GeV. The proton and net-proton results qualitatively resemble predictions of a hydrodynamic model with a first-order phase transition from hadronic matter to deconfined matter, and differ from hadronic transport calculations.
Resumo:
The main aim of this investigation was to verify the relationship of the variables measured during a 3-minute all-out test with aerobic (i.e., peak oxygen uptake [(Equation is included in full-text article.)] and intensity corresponding to the lactate minimum [LMI]) and anaerobic parameters (i.e., anaerobic work) measured during a 400-m maximal performance. To measure force continually and to avoid the possible influences caused by turns, the 3-minute all-out effort was performed in tethered swimming. Thirty swimmers performed the following tests: (a) a 3-minute all-out tethered swimming test to determine the final force (equivalent to critical force: CF3-MIN) and the work performed above CF3-MIN (W'3-MIN), (b) a LMI protocol to determine the LMI during front crawl swimming, and (c) a 400-m maximal test to determine the (Equation is included in full-text article.)and total anaerobic contribution (WANA). Correlations between the variables were tested using the Pearson's correlation test (p ≤ 0.05). CF3-MIN (73.9 ± 13.2 N) presented a high correlation with the LMI (1.33 ± 0.08 m·s; p = 0.01) and (Equation is included in full-text article.)(4.5 ± 1.2 L·min; p = 0.01). However, the W'3-MIN (1,943.2 ± 719.2 N·s) was only moderately correlated with LMI (p = 0.02) and (Equation is included in full-text article.)(p = 0.01). In summary, CF3-MIN determined during the 3-minute all-out effort is associated with oxidative metabolism and can be used to estimate the aerobic capacity of swimmers. In contrast, the anaerobic component of this model (W'3-MIN) is not correlated with WANA.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
This in vitro study aimed to analyze the effect of different parameters of phototherapy with low intensity laser on the viability of human dental pulp fibroblasts under the effect of substances released by bleaching gel. Cells were seeded into 96 wells plates (1 x 10³ cells/well) and placed in contact with culture medium conditioned by a 35 % hydrogen peroxide bleaching gel for 40 minutes, simulating the clinical condition of the in-office bleaching treatment. Cells cultured in ideal growth conditions served as positive control group (PC), and the cells grown in conditioned medium and non-irradiated served as negative control group (NC). Cells grown in conditioned medium were submitted to a single irradiation with a diode laser (40 mW, 0.04 cm²) emitting at visible red (660 nm; RL) or near infrared (780 nm; NIR) using punctual technique, in contact mode and energy densities of 4, 6 or 10 J/cm². The cell viability was analyzed through the MTT reduction assay immediately and 24 hours after the irradiation. The data was compared by ANOVA followed by the Tukey's test (p < 0.05). The cell viability increased significantly in 24 hours within each group. The PC presented cell viability significantly higher than NC in both experimental times. Only the NIR/10 J/cm² group presented cell viability similar to that of PC in 24 hours. The phototherapy with low intensity laser in defined parameters is able to compensate the cytotoxic effects of substances released by 35 % hydrogen peroxide bleaching gel.
Resumo:
Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E), peak A wave (peak A), E/A ratio (E/A), E wave deceleration time (EDT) and isovolumic relaxation time (IRVT) were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT), by age (peak A and E/A) and by body weight (TRIV). Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.