985 resultados para Occupant protection devices.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The estimation of feed efficiency in beef cattle should be undertaken in the environment where the genetic potential of the animal is to be expressed. Consequently if cattle are to be pasture fed, there is a requirement for accurate feed intake measurements on individual animals in the field. This in turn requires the use of accurate faecal marker delivery systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cross-protection and haemagglutination-inhibition antibodies present in chickens vaccinated with one of the nine currently recognized Kume haemagglutinin serovars of Haemophilus paragallinarum were investigated. The results confirmed the widely accepted dogma that serogroups A, B, and C represent three distinct immunovars. Within Kume serogroup A, there was generally good cross-protection among all four serovars. However, within Kume serogroup C, there was evidence of a reduced level of cross protection between some of the four serovars. The haemagglutination-inhibition antibody levels generally showed the same trend as with the cross-protection results. This study suggests that some apparent field failures of infectious coryza vaccines may be due to a lack of cross-protection between the vaccine strains and the field strains. Our results will help guide the selection of strains for inclusion in infectious coryza vaccines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to help broaden the use of electronic portal imaging devices (EPIDs) for pre-treatment patient positioning verification, from photon-beam radiotherapy to photon- and electron-beam radiotherapy, by proposing and testing a method for acquiring clinicallyuseful EPID images of patient anatomy using electron beams, with a view to enabling and encouraging further research in this area. EPID images used in this study were acquired using all available beams from a linac configured to deliver electron beams with nominal energies of 6, 9, 12, 16 and 20 MeV, as well as photon beams with nominal energies of 6 and 10 MV. A widely-available heterogeneous, approximately-humanoid, thorax phantom was used, to provide an indication of the contrast and noise produced when imaging different types of tissue with comparatively realistic thicknesses. The acquired images were automatically calibrated, corrected for the effects of variations in the sensitivity of individual photodiodes, using a flood field image. For electron beam imaging, flood field EPID calibration images were acquired with and without the placement of blocks of water-equivalent plastic (with thicknesses approximately equal to the practical range of electrons in the plastic) placed upstream of the EPID, to filter out the primary electron beam, leaving only the bremsstrahlung photon signal. While the electron beam images acquired using a standard (unfiltered) flood field calibration were observed to be noisy and difficult to interpret, the electron beam images acquired using the filtered flood field calibration showed tissues and bony anatomy with levels of contrast and noise that were similar to the contrast and noise levels seen in the clinically acceptable photon beam EPID images. The best electron beam imaging results (highest contrast, signal-to-noise and contrast-to-noise ratios) were achieved when the images were acquired using the higher energy electron beams (16 and 20 MeV) when the EPID was calibrated using an intermediate (12 MeV) electron beam energy. These results demonstrate the feasibility of acquiring clinically-useful EPID images of patient anatomy using electron beams and suggest important avenues for future investigation, thus enabling and encouraging further research in this area. There is manifest potential for the EPID imaging method proposed in this work to lead to the clinical use of electron beam imaging for geometric verification of electron treatments in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents results from an experimental 10-day research charter that was designed to quantify the effects of a) a turtle excluder device (TED) and b) a radial escape section bycatch reduction device (BRD) and c) both devices together, on prawn and bycatch catch rates in the Queensland shallow water eastern king prawn (Penaeus plebejus) trawl fishery. The bycatch was comprised of 250 taxa, mainly gurnards, whiting, lizard fish, flathead, dragonets, portunid crabs, turretfish and flounders. The observed mean catch rates of bycatch and marketable eastern king prawns from the standard trawl net (i.e., net with no TED or BRD) used during the charter were 11.06 (se 0.90) kg per hectare swept by the trawl gear (ha-1) and 0.94 kg ha-1, respectively. For the range of depths sampled (20.1-90.7 m), bycatch catch rates declined significantly at a rate of 0.14 kg ha-1 for every 1 m increase in depth, while prawn catch rates were unaffected. When both the TED and radial escape section BRD were used together they resulted in a 24% reduction in total bycatch catch rate compared to a standard net, but at a 20% reduction in marketable prawn catch rate. The largest reductions were achieved for stout whiting Sillago robusta (57% reduction) and yellowtail scad Trachurus novaezelandiae (32% reduction). Multidimensional scaling and analysis of similarities revealed that bycatch assemblages differed significantly between depths and latitude, but not between the different combinations of bycatch reduction devices. Despite the lowered prawn catch rates, the reduced bycatch catch rates are promising, particularly for S. robusta which is not permitted to be retained by the prawn trawl fleet and yet experiences considerable incidental fishing mortality, and because it is targeted in a separate licensed commercial fishery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Australia's child protection systems and the provision of out-of-home care, in particular, have been subject to sustained criticism for decades from dozens of official inquiries and reviews. It is now well established that many children in state care are treated significantly less well than required by relevant legal frameworks and community standards. Much attention and significant resources have been directed toward trying to ameliorate this ‘wicked problem’ and yet it continues. This article focuses on one reason the problems persists, namely the secrecy and closed cultures that characterize relevant organizations which reinforce strategies of denial that avoid acknowledging or dealing with ‘uncomfortable knowledge’. It is a situation many people in child protection systems confront. It is, for example, when we know abuse is taking place, or when they see or are ourselves party to corrupt or negligent practices. It is knowing that important ethical principles are being abrogated. We draw on recent official reports and inquiries noting the repeated calls for greater transparency and independent oversight. An argument is made for a default position of total transparency subject to caveats that protect privacy and any investigation underway. An account of what this can look like is offered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laboratory and field data reported in the literature are confusing with regard to “adequate” protection thresholds for borate timber preservatives. The confusion is compounded by differences in termite species, timber species and test methodology. Laboratory data indicate a borate retention of 0.5% mass/mass (m/m) boric acid equivalent (BAE) would cause >90% termite mortality and restrict mass loss in test specimens to ≤5%. Field data generally suggest that borate retentions appreciably >0.5% m/m BAE are required. We report two field experiments with varying amounts of untreated feeder material in which Coptotermes acinaciformis (Froggatt) (Isoptera: Rhinotermitidae) responses to borate-treated radiata (Monterey) pine, Pinus radiata D. Don, were measured. The apparently conflicting results between laboratory and field data are explained by the presence or absence of untreated feeder material in the test environment. In the absence of untreated feeder material, wood containing 0.5% BAE provided adequate protection from Coptotermes sp., whereas in the presence of untreated feeder material, increased retentions were required. Furthermore, the retentions required increased with increased amounts of susceptible material present. Some termites, Nasutitermes sp. and Mastotermes darwiniensis Froggatt, for example, are borate-tolerant and borate timber preservatives are not a viable management option with these species. The lack of uniform standards for termite test methodology and assessment criteria for efficacy across the world is recognized as a difficulty with research into the performance of timber preservatives with termites. The many variables in laboratory and field assays make “prescriptive” standards difficult to recommend. The use of “performance” standards to define efficacy criteria (“adequate” protection) is discussed.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sampling devices differing greatly in shape, size and operating condition have been used to collect air samples to determine rates of emission of volatile substances, including odour. However, physical chemistry principles, in particular the partitioning of volatile substances between two phases as explained by Henrys Law and the relationship between wind velocity and emission rate, suggests that different devices cannot be expected to provide equivalent emission rate estimates. Thus several problems are associated with the use of static and dynamic emission chambers, but the more turbulent devices such as wind tunnels do not appear to be subject to these problems. In general, the ability to relate emission rate estimates obtained from wind tunnel measurements to those derived from device-independent techniques supports the use of wind tunnels to determine emission rates that can be used as input data for dispersion models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two commonly used sampling devices (a wind tunnel and the US EPA dynamic emission chamber), were used to collect paired samples of odorous air from a number of agricultural odour sources. The odour samples were assessed using triangular, forced-choice dynamic olfactometry. The odour concentration data was combined with the flushing rate data to calculate odour emission rates for both devices on all sources. Odour concentrations were consistently higher in samples collected with a flux chamber (ratio ranging from 10:7 to 5:1, relative to wind tunnel samples), whereas odour emission rates were consistently larger when derived from wind tunnels (ratio ranging from 60:1 to 240:1, relative to flux chamber values). A complex relationship existed between emission rate estimates derived from each device, apparently influenced by the nature of the emitting surface. These results have great significance for users of odour dispersion models, for which an odour emission rate is a key input parameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a low-frequency electrical noise measurement in graphene based field effect transistors. For single layer graphene (SLG), the resistance fluctuations is governed by the screening of the charge impurities by the mobile charges. However, in case of Bilayer graphene (BLG), the electrical noise is strongly connected to its band structure, and unlike single layer graphene, displays a minimum when the gap between the conduction and valence band is zero. Using double gated BLG devices we have tuned the zero gap and charge neutrality points independently, which offers a versatile mechanism to investigate the low-energy band structure, charge localization and screening properties of bilayer graphene

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The law provides rights for PWD for easy access of public goods, including education, social security, medical treatment, occupational and social rehabilitation and establishes an extent of responsibility of the government and its bodies for the creation of favourable conditions for the social adaptation of PWDs in market environment conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An in-depth knowledge about the characteristics of lightning generated currents will facilitate evaluation of the interception efficacy of lightning protection systems. In addition, it would aid in extraction of valuable statistics (from measured current data) on local lightning parameters. Incidentally, present day knowledge on characteristics of lightning induced current in typical lightning protection systems is rather limited. This is particularly true with closely interconnected protection systems, like the one employed in Indian Satellite Launch Pad-II. This system is taken as a specific example in the present study. Various aspects suggest that theoretical modelling would be the best possible approach for the intended work. From the survey of pertinent literature, it is concluded that electromagnetic modelling of lightning return-stroke with current source at the channel base is best suited for this study. Numerical electromagnetic code was used for the required electromagnetic field solution and Fourier transform techniques were employed for computing time-domain results. A validation for the numerical modelling is provided by laborator experiments on a reduced scale model of the system. Apart from ascertaining the influence of various parameters, salient characteristics of tower base currents for different kinds of events are deduced. This knowledge can be used in identifying the type of event, as well as its approximate location. A method for estimation of injected stroke current has also been proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of algorithms, based on Haar functions, for extracting the desired frequency components from transient power-system relaying signals is presented. The applications of these algorithms to impedance detection in transmission line protection and to harmonic restraint in transformer differential protection are discussed. For transmission line protection, three modes of application of the Haar algorithms are described: a full-cycle window algorithm, an approximate full-cycle window algorithm, and a half-cycle window algorithm. For power transformer differential protection, the combined second and fifth harmonic magnitude of the differential current is compared with that of fundamental to arrive at a trip decision. The proposed line protection algorithms are evaluated, under different fault conditions, using realistic relaying signals obtained from transient analysis conducted on a model 400 kV, 3-phase system. The transformer differential protection algorithms are also evaluated using a variety of simulated inrush and internal fault signals.