878 resultados para Multi-resolution Method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, mixed spectral-structural kernel machines are proposed for the classification of very-high resolution images. The simultaneous use of multispectral and structural features (computed using morphological filters) allows a significant increase in classification accuracy of remote sensing images. Subsequently, weighted summation kernel support vector machines are proposed and applied in order to take into account the multiscale nature of the scene considered. Such classifiers use the Mercer property of kernel matrices to compute a new kernel matrix accounting simultaneously for two scale parameters. Tests on a Zurich QuickBird image show the relevance of the proposed method : using the mixed spectral-structural features, the classification accuracy increases of about 5%, achieving a Kappa index of 0.97. The multikernel approach proposed provide an overall accuracy of 98.90% with related Kappa index of 0.985.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multi-center studies using magnetic resonance imaging facilitate studying small effect sizes, global population variance and rare diseases. The reliability and sensitivity of these multi-center studies crucially depend on the comparability of the data generated at different sites and time points. The level of inter-site comparability is still controversial for conventional anatomical T1-weighted MRI data. Quantitative multi-parameter mapping (MPM) was designed to provide MR parameter measures that are comparable across sites and time points, i.e., 1 mm high-resolution maps of the longitudinal relaxation rate (R1 = 1/T1), effective proton density (PD(*)), magnetization transfer saturation (MT) and effective transverse relaxation rate (R2(*) = 1/T2(*)). MPM was validated at 3T for use in multi-center studies by scanning five volunteers at three different sites. We determined the inter-site bias, inter-site and intra-site coefficient of variation (CoV) for typical morphometric measures [i.e., gray matter (GM) probability maps used in voxel-based morphometry] and the four quantitative parameters. The inter-site bias and CoV were smaller than 3.1 and 8%, respectively, except for the inter-site CoV of R2(*) (<20%). The GM probability maps based on the MT parameter maps had a 14% higher inter-site reproducibility than maps based on conventional T1-weighted images. The low inter-site bias and variance in the parameters and derived GM probability maps confirm the high comparability of the quantitative maps across sites and time points. The reliability, short acquisition time, high resolution and the detailed insights into the brain microstructure provided by MPM makes it an efficient tool for multi-center imaging studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Land use/cover classification is one of the most important applications in remote sensing. However, mapping accurate land use/cover spatial distribution is a challenge, particularly in moist tropical regions, due to the complex biophysical environment and limitations of remote sensing data per se. This paper reviews experiments related to land use/cover classification in the Brazilian Amazon for a decade. Through comprehensive analysis of the classification results, it is concluded that spatial information inherent in remote sensing data plays an essential role in improving land use/cover classification. Incorporation of suitable textural images into multispectral bands and use of segmentation‑based method are valuable ways to improve land use/cover classification, especially for high spatial resolution images. Data fusion of multi‑resolution images within optical sensor data is vital for visual interpretation, but may not improve classification performance. In contrast, integration of optical and radar data did improve classification performance when the proper data fusion method was used. Among the classification algorithms available, the maximum likelihood classifier is still an important method for providing reasonably good accuracy, but nonparametric algorithms, such as classification tree analysis, have the potential to provide better results. However, they often require more time to achieve parametric optimization. Proper use of hierarchical‑based methods is fundamental for developing accurate land use/cover classification, mainly from historical remotely sensed data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to evaluate sampling density on the prediction accuracy of soil orders, with high spatial resolution, in a viticultural zone of Serra Gaúcha, Southern Brazil. A digital elevation model (DEM), a cartographic base, a conventional soil map, and the Idrisi software were used. Seven predictor variables were calculated and read along with soil classes in randomly distributed points, with sampling densities of 0.5, 1, 1.5, 2, and 4 points per hectare. Data were used to train a decision tree (Gini) and three artificial neural networks: adaptive resonance theory, fuzzy ARTMap; self‑organizing map, SOM; and multi‑layer perceptron, MLP. Estimated maps were compared with the conventional soil map to calculate omission and commission errors, overall accuracy, and quantity and allocation disagreement. The decision tree was less sensitive to sampling density and had the highest accuracy and consistence. The SOM was the less sensitive and most consistent network. The MLP had a critical minimum and showed high inconsistency, whereas fuzzy ARTMap was more sensitive and less accurate. Results indicate that sampling densities used in conventional soil surveys can serve as a reference to predict soil orders in Serra Gaúcha.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context: In the milder form of primary hyperparathyroidism (PHPT), cancellous bone, represented by areal bone mineral density at the lumbar spine by dual-energy x-ray absorptiometry (DXA), is preserved. This finding is in contrast to high-resolution peripheral quantitative computed tomography (HRpQCT) results of abnormal trabecular microstructure and epidemiological evidence for increased overall fracture risk in PHPT. Because DXA does not directly measure trabecular bone and HRpQCT is not widely available, we used trabecular bone score (TBS), a novel gray-level textural analysis applied to spine DXA images, to estimate indirectly trabecular microarchitecture. Objective: The purpose of this study was to assess TBS from spine DXA images in relation to HRpQCT indices and bone stiffness in radius and tibia in PHPT. Design and Setting: This was a cross-sectional study conducted in a referral center. Patients: Participants were 22 postmenopausal women with PHPT. Main Outcome Measures: Outcomes measured were areal bone mineral density by DXA, TBS indices derived from DXA images, HRpQCT standard measures, and bone stiffness assessed by finite element analysis at distal radius and tibia. Results: TBS in PHPT was low at 1.24, representing abnormal trabecular microstructure (normal ≥1.35). TBS was correlated with whole bone stiffness and all HRpQCT indices, except for trabecular thickness and trabecular stiffness at the radius. At the tibia, correlations were observed between TBS and volumetric densities, cortical thickness, trabecular bone volume, and whole bone stiffness. TBS correlated with all indices of trabecular microarchitecture, except trabecular thickness, after adjustment for body weight. Conclusion: TBS, a measurement technology readily available by DXA, shows promise in the clinical assessment of trabecular microstructure in PHPT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article we propose a novel method for calculating cardiac 3-D strain. The method requires the acquisition of myocardial short-axis (SA) slices only and produces the 3-D strain tensor at every point within every pair of slices. Three-dimensional displacement is calculated from SA slices using zHARP which is then used for calculating the local displacement gradient and thus the local strain tensor. There are three main advantages of this method. First, the 3-D strain tensor is calculated for every pixel without interpolation; this is unprecedented in cardiac MR imaging. Second, this method is fast, in part because there is no need to acquire long-axis (LA) slices. Third, the method is accurate because the 3-D displacement components are acquired simultaneously and therefore reduces motion artifacts without the need for registration. This article presents the theory of computing 3-D strain from two slices using zHARP, the imaging protocol, and both phantom and in-vivo validation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

De tout temps, hommes et femmes ont cherché par tous les moyens à développer, préserver ou recouvrer leurs propres capacités sexuelles mais également à stimuler le désir du partenaire. L?utilisation d?aphrodisiaques naturels a été l?un des recours les plus répandus. De nos jours, la commercialisation de nouvelles "love drugs" de synthèse, e.g. Viagra®, Cialis®, Levitra®, a remis au goût du jour les aphrodisiaques classiques et à relancer la recherche sur des molécules nouvelles. La pratique croissante de l?automédication, le matraquage publicitaire sur les aphrodisiaques naturels, la prolifération sur le marché de compléments alimentaires non contrôlés et l?absence de véritable législation accroissent les risques qui pèsent sur la santé publique. Dans le but d?évaluer les risques potentiels sur le consommateur de produits aphrodisiaques commercialisés, le développement et la validation d?une méthode rapide d?analyse qualitative et quantitative de la yohimbine dans ces préparations du marché sont exposés dans la première partie de ce travail. La yohimbine est un antagoniste ?2-adrénocepteur du système nerveux central et périphérique, elle est employée depuis plus d?un siècle dans le traitement des dysfonctionnements érectiles. Cette méthode analytique utilise la chromatographie liquide couplée à l?ultraviolet et à la spectrométrie de masse (LC-UV-MS) et au total, vingt préparations aphrodisiaques ont été étudiées. La dose journalière de yohimbine mesurée s?est révélée très variable selon les produits puisqu?elle varie de 1.32 à 23.16 mg. La seconde partie de ce travail concerne l?étude phytochimique et pharmacologique d?Erythroxylum vacciniifolium Mart. (Erythroxylaceae), une plante, appelée localement catuaba, utilisée dans la médecine traditionnelle brésilienne comme tonique et aphrodisiaque. Dans un premier temps, l?extrait alcaloïdique a été analysé par chromatographie liquide haute performance (HPLC) couplée soit à un détecteur UV à barrette d?iode (LC-UV-DAD), soit à un spectromètre de masse (LC-MS), ou soit à un spectromètre de résonance magnétique nucléaire (LC-RMN). L?interprétation de ces données spectrales enregistrées en ligne a permis d?obtenir des informations structurales et d?identifier partiellement près de 24 alcaloïdes appartenant à la classe des tropanes et potentiellement originaux. Par des méthodes classiques de chromatographie liquide sur l?extrait alcaloïdique de la plante, dix sept tropanes nouveaux ont ensuite été isolés dont les catuabines et leurs dérivés, et les vaccinines. Tous ces composés sont des tropane-diols ou triols estérifiés par au moins un groupe acide 1-méthyl-1H-pyrrole-2-carboxylique. Un de ces composés a été identifié comme un tropane N-oxyde. Toutes les structures ont été déterminées par spectrométrie de masse haute résolution et spectroscopie RMN multi-dimensionnelle. Parmi les nombreux tests biologiques réalisés sur ces tropanes, seuls les tests de cytotoxicité se sont révélés faiblement positifs pour certains de ces composés.<br/><br/>Throughout the ages, men and women have incessantly pursued every means to increase, preserve or recapture their sexual capacity, or to stimulate the sexual desire of selected individuals. One of the most recurrent methods has been the use of natural aphrodisiacs. Nowadays, the commercialization of new synthetic "love drugs", e.g. Viagra®, Cialis® and Levitra®, has fascinated the public interest and has led to a reassessment of classical aphrodisiacs and to the search for new ones. The practice of self-medication by an increasing number of patients, the incessant aggressive advertising of these herbal aphrodisiacs, the invasion of the medicinal market with uncontrolled dietary supplements and the absence of real directives amplifies the potential health hazards to the community. In order to evaluate the possible risks of commercialized aphrodisiac products on consumer health, the development and validation of a rapid qualitative and quantitative method for the analysis of yohimbine in these products, is reported in the first part of the present work. Yohimbine, a pharmacologically well-characterized ?2-adrenoceptor antagonist with activity in the central and peripheral nervous system, has been used for over a century in the treatment of erectile dysfunction. The analytical method is based on liquid chromatography coupled with ultraviolet and mass spectrometry (LC-UV-MS) and in total, 20 commercially-available aphrodisiac preparations were analyzed. The amount of yohimbine measured and expressed as the maximal dose per day suggested on product labels ranged from 1.32 to 23.16 mg. The second part of this work involved the phytochemical and pharmacological investigation of Erythroxylum vacciniifolium Mart. (Erythroxylaceae), a plant used in Brazilian traditional medicine as an aphrodisiac and tonic, and locally known as catuaba. With the aim of obtaining preliminary structure information on-line, the alkaloid extract was analyzed by high performance liquid chromatography (HPLC) coupled to diode array UV detection (LC-UVDAD), to mass spectrometry (LC-MS) and to nuclear magnetic resonance spectroscopy (LCNMR). Interpretation of on-line spectroscopic data led to structure elucidation and partial identification of 24 potentially original alkaloids bearing the same tropane skeleton. Seventeen new tropane alkaloids were then isolated from the alkaloid extract of the plant, including catuabines D to I, their derivatives and vaccinines A and B. All compounds were elucidated as tropane-diol or -triol alkaloids esterified by at least one 1-methyl-1H-pyrrole-2-carboxylic acid. One of the isolated compounds was identified as a tropane alkaloid N-oxide. Their structures were determined by high resolution mass spectrometry and multi-dimensional NMR spectroscopy. Among the numerous bioassays undertaken, only the cytotoxicity tests exhibited a weak positive activity of certain compounds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Un système efficace de sismique tridimensionnelle (3-D) haute-résolution adapté à des cibles lacustres de petite échelle a été développé. Dans le Lac Léman, près de la ville de Lausanne, en Suisse, des investigations récentes en deux dimension (2-D) ont mis en évidence une zone de faille complexe qui a été choisie pour tester notre système. Les structures observées incluent une couche mince (<40 m) de sédiments quaternaires sub-horizontaux, discordants sur des couches tertiaires de molasse pentées vers le sud-est. On observe aussi la zone de faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau de la Molasse Subalpine. Deux campagnes 3-D complètes, d?environ d?un kilomètre carré, ont été réalisées sur ce site de test. La campagne pilote (campagne I), effectuée en 1999 pendant 8 jours, a couvert 80 profils en utilisant une seule flûte. Pendant la campagne II (9 jours en 2001), le nouveau système trois-flûtes, bien paramétrés pour notre objectif, a permis l?acquisition de données de très haute qualité sur 180 lignes CMP. Les améliorations principales incluent un système de navigation et de déclenchement de tirs grâce à un nouveau logiciel. Celui-ci comprend un contrôle qualité de la navigation du bateau en temps réel utilisant un GPS différentiel (dGPS) à bord et une station de référence près du bord du lac. De cette façon, les tirs peuvent être déclenchés tous les 5 mètres avec une erreur maximale non-cumulative de 25 centimètres. Tandis que pour la campagne I la position des récepteurs de la flûte 48-traces a dû être déduite à partir des positions du bateau, pour la campagne II elle ont pu être calculées précisément (erreur <20 cm) grâce aux trois antennes dGPS supplémentaires placées sur des flotteurs attachés à l?extrémité de chaque flûte 24-traces. Il est maintenant possible de déterminer la dérive éventuelle de l?extrémité des flûtes (75 m) causée par des courants latéraux ou de petites variations de trajet du bateau. De plus, la construction de deux bras télescopiques maintenant les trois flûtes à une distance de 7.5 m les uns des autres, qui est la même distance que celle entre les lignes naviguées de la campagne II. En combinaison avec un espacement de récepteurs de 2.5 m, la dimension de chaque «bin» de données 3-D de la campagne II est de 1.25 m en ligne et 3.75 m latéralement. L?espacement plus grand en direction « in-line » par rapport à la direction «cross-line» est justifié par l?orientation structurale de la zone de faille perpendiculaire à la direction «in-line». L?incertitude sur la navigation et le positionnement pendant la campagne I et le «binning» imprécis qui en résulte, se retrouve dans les données sous forme d?une certaine discontinuité des réflecteurs. L?utilisation d?un canon à air à doublechambre (qui permet d?atténuer l?effet bulle) a pu réduire l?aliasing observé dans les sections migrées en 3-D. Celui-ci était dû à la combinaison du contenu relativement haute fréquence (<2000 Hz) du canon à eau (utilisé à 140 bars et à 0.3 m de profondeur) et d?un pas d?échantillonnage latéral insuffisant. Le Mini G.I 15/15 a été utilisé à 80 bars et à 1 m de profondeur, est mieux adapté à la complexité de la cible, une zone faillée ayant des réflecteurs pentés jusqu?à 30°. Bien que ses fréquences ne dépassent pas les 650 Hz, cette source combine une pénétration du signal non-aliasé jusqu?à 300 m dans le sol (par rapport au 145 m pour le canon à eau) pour une résolution verticale maximale de 1.1 m. Tandis que la campagne I a été acquise par groupes de plusieurs lignes de directions alternées, l?optimisation du temps d?acquisition du nouveau système à trois flûtes permet l?acquisition en géométrie parallèle, ce qui est préférable lorsqu?on utilise une configuration asymétrique (une source et un dispositif de récepteurs). Si on ne procède pas ainsi, les stacks sont différents selon la direction. Toutefois, la configuration de flûtes, plus courtes que pour la compagne I, a réduit la couverture nominale, la ramenant de 12 à 6. Une séquence classique de traitement 3-D a été adaptée à l?échantillonnage à haute fréquence et elle a été complétée par deux programmes qui transforment le format non-conventionnel de nos données de navigation en un format standard de l?industrie. Dans l?ordre, le traitement comprend l?incorporation de la géométrie, suivi de l?édition des traces, de l?harmonisation des «bins» (pour compenser l?inhomogénéité de la couverture due à la dérive du bateau et de la flûte), de la correction de la divergence sphérique, du filtrage passe-bande, de l?analyse de vitesse, de la correction DMO en 3-D, du stack et enfin de la migration 3-D en temps. D?analyses de vitesse détaillées ont été effectuées sur les données de couverture 12, une ligne sur deux et tous les 50 CMP, soit un nombre total de 600 spectres de semblance. Selon cette analyse, les vitesses d?intervalles varient de 1450-1650 m/s dans les sédiments non-consolidés et de 1650-3000 m/s dans les sédiments consolidés. Le fait que l?on puisse interpréter plusieurs horizons et surfaces de faille dans le cube, montre le potentiel de cette technique pour une interprétation tectonique et géologique à petite échelle en trois dimensions. On distingue cinq faciès sismiques principaux et leurs géométries 3-D détaillées sur des sections verticales et horizontales: les sédiments lacustres (Holocène), les sédiments glacio-lacustres (Pléistocène), la Molasse du Plateau, la Molasse Subalpine de la zone de faille (chevauchement) et la Molasse Subalpine au sud de cette zone. Les couches de la Molasse du Plateau et de la Molasse Subalpine ont respectivement un pendage de ~8° et ~20°. La zone de faille comprend de nombreuses structures très déformées de pendage d?environ 30°. Des tests préliminaires avec un algorithme de migration 3-D en profondeur avant sommation et à amplitudes préservées démontrent que la qualité excellente des données de la campagne II permet l?application de telles techniques à des campagnes haute-résolution. La méthode de sismique marine 3-D était utilisée jusqu?à présent quasi-exclusivement par l?industrie pétrolière. Son adaptation à une échelle plus petite géographiquement mais aussi financièrement a ouvert la voie d?appliquer cette technique à des objectifs d?environnement et du génie civil.<br/><br/>An efficient high-resolution three-dimensional (3-D) seismic reflection system for small-scale targets in lacustrine settings was developed. In Lake Geneva, near the city of Lausanne, Switzerland, past high-resolution two-dimensional (2-D) investigations revealed a complex fault zone (the Paudèze thrust zone), which was subsequently chosen for testing our system. Observed structures include a thin (<40 m) layer of subhorizontal Quaternary sediments that unconformably overlie southeast-dipping Tertiary Molasse beds and the Paudèze thrust zone, which separates Plateau and Subalpine Molasse units. Two complete 3-D surveys have been conducted over this same test site, covering an area of about 1 km2. In 1999, a pilot survey (Survey I), comprising 80 profiles, was carried out in 8 days with a single-streamer configuration. In 2001, a second survey (Survey II) used a newly developed three-streamer system with optimized design parameters, which provided an exceptionally high-quality data set of 180 common midpoint (CMP) lines in 9 days. The main improvements include a navigation and shot-triggering system with in-house navigation software that automatically fires the gun in combination with real-time control on navigation quality using differential GPS (dGPS) onboard and a reference base near the lake shore. Shots were triggered at 5-m intervals with a maximum non-cumulative error of 25 cm. Whereas the single 48-channel streamer system of Survey I requires extrapolation of receiver positions from the boat position, for Survey II they could be accurately calculated (error <20 cm) with the aid of three additional dGPS antennas mounted on rafts attached to the end of each of the 24- channel streamers. Towed at a distance of 75 m behind the vessel, they allow the determination of feathering due to cross-line currents or small course variations. Furthermore, two retractable booms hold the three streamers at a distance of 7.5 m from each other, which is the same distance as the sail line interval for Survey I. With a receiver spacing of 2.5 m, the bin dimension of the 3-D data of Survey II is 1.25 m in in-line direction and 3.75 m in cross-line direction. The greater cross-line versus in-line spacing is justified by the known structural trend of the fault zone perpendicular to the in-line direction. The data from Survey I showed some reflection discontinuity as a result of insufficiently accurate navigation and positioning and subsequent binning errors. Observed aliasing in the 3-D migration was due to insufficient lateral sampling combined with the relatively high frequency (<2000 Hz) content of the water gun source (operated at 140 bars and 0.3 m depth). These results motivated the use of a double-chamber bubble-canceling air gun for Survey II. A 15 / 15 Mini G.I air gun operated at 80 bars and 1 m depth, proved to be better adapted for imaging the complexly faulted target area, which has reflectors dipping up to 30°. Although its frequencies do not exceed 650 Hz, this air gun combines a penetration of non-aliased signal to depths of 300 m below the water bottom (versus 145 m for the water gun) with a maximum vertical resolution of 1.1 m. While Survey I was shot in patches of alternating directions, the optimized surveying time of the new threestreamer system allowed acquisition in parallel geometry, which is preferable when using an asymmetric configuration (single source and receiver array). Otherwise, resulting stacks are different for the opposite directions. However, the shorter streamer configuration of Survey II reduced the nominal fold from 12 to 6. A 3-D conventional processing flow was adapted to the high sampling rates and was complemented by two computer programs that format the unconventional navigation data to industry standards. Processing included trace editing, geometry assignment, bin harmonization (to compensate for uneven fold due to boat/streamer drift), spherical divergence correction, bandpass filtering, velocity analysis, 3-D DMO correction, stack and 3-D time migration. A detailed semblance velocity analysis was performed on the 12-fold data set for every second in-line and every 50th CMP, i.e. on a total of 600 spectra. According to this velocity analysis, interval velocities range from 1450-1650 m/s for the unconsolidated sediments and from 1650-3000 m/s for the consolidated sediments. Delineation of several horizons and fault surfaces reveal the potential for small-scale geologic and tectonic interpretation in three dimensions. Five major seismic facies and their detailed 3-D geometries can be distinguished in vertical and horizontal sections: lacustrine sediments (Holocene) , glaciolacustrine sediments (Pleistocene), Plateau Molasse, Subalpine Molasse and its thrust fault zone. Dips of beds within Plateau and Subalpine Molasse are ~8° and ~20°, respectively. Within the fault zone, many highly deformed structures with dips around 30° are visible. Preliminary tests with 3-D preserved-amplitude prestack depth migration demonstrate that the excellent data quality of Survey II allows application of such sophisticated techniques even to high-resolution seismic surveys. In general, the adaptation of the 3-D marine seismic reflection method, which to date has almost exclusively been used by the oil exploration industry, to a smaller geographical as well as financial scale has helped pave the way for applying this technique to environmental and engineering purposes.<br/><br/>La sismique réflexion est une méthode d?investigation du sous-sol avec un très grand pouvoir de résolution. Elle consiste à envoyer des vibrations dans le sol et à recueillir les ondes qui se réfléchissent sur les discontinuités géologiques à différentes profondeurs et remontent ensuite à la surface où elles sont enregistrées. Les signaux ainsi recueillis donnent non seulement des informations sur la nature des couches en présence et leur géométrie, mais ils permettent aussi de faire une interprétation géologique du sous-sol. Par exemple, dans le cas de roches sédimentaires, les profils de sismique réflexion permettent de déterminer leur mode de dépôt, leurs éventuelles déformations ou cassures et donc leur histoire tectonique. La sismique réflexion est la méthode principale de l?exploration pétrolière. Pendant longtemps on a réalisé des profils de sismique réflexion le long de profils qui fournissent une image du sous-sol en deux dimensions. Les images ainsi obtenues ne sont que partiellement exactes, puisqu?elles ne tiennent pas compte de l?aspect tridimensionnel des structures géologiques. Depuis quelques dizaines d?années, la sismique en trois dimensions (3-D) a apporté un souffle nouveau à l?étude du sous-sol. Si elle est aujourd?hui parfaitement maîtrisée pour l?imagerie des grandes structures géologiques tant dans le domaine terrestre que le domaine océanique, son adaptation à l?échelle lacustre ou fluviale n?a encore fait l?objet que de rares études. Ce travail de thèse a consisté à développer un système d?acquisition sismique similaire à celui utilisé pour la prospection pétrolière en mer, mais adapté aux lacs. Il est donc de dimension moindre, de mise en oeuvre plus légère et surtout d?une résolution des images finales beaucoup plus élevée. Alors que l?industrie pétrolière se limite souvent à une résolution de l?ordre de la dizaine de mètres, l?instrument qui a été mis au point dans le cadre de ce travail permet de voir des détails de l?ordre du mètre. Le nouveau système repose sur la possibilité d?enregistrer simultanément les réflexions sismiques sur trois câbles sismiques (ou flûtes) de 24 traces chacun. Pour obtenir des données 3-D, il est essentiel de positionner les instruments sur l?eau (source et récepteurs des ondes sismiques) avec une grande précision. Un logiciel a été spécialement développé pour le contrôle de la navigation et le déclenchement des tirs de la source sismique en utilisant des récepteurs GPS différentiel (dGPS) sur le bateau et à l?extrémité de chaque flûte. Ceci permet de positionner les instruments avec une précision de l?ordre de 20 cm. Pour tester notre système, nous avons choisi une zone sur le Lac Léman, près de la ville de Lausanne, où passe la faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau et de la Molasse Subalpine. Deux campagnes de mesures de sismique 3-D y ont été réalisées sur une zone d?environ 1 km2. Les enregistrements sismiques ont ensuite été traités pour les transformer en images interprétables. Nous avons appliqué une séquence de traitement 3-D spécialement adaptée à nos données, notamment en ce qui concerne le positionnement. Après traitement, les données font apparaître différents faciès sismiques principaux correspondant notamment aux sédiments lacustres (Holocène), aux sédiments glacio-lacustres (Pléistocène), à la Molasse du Plateau, à la Molasse Subalpine de la zone de faille et la Molasse Subalpine au sud de cette zone. La géométrie 3-D détaillée des failles est visible sur les sections sismiques verticales et horizontales. L?excellente qualité des données et l?interprétation de plusieurs horizons et surfaces de faille montrent le potentiel de cette technique pour les investigations à petite échelle en trois dimensions ce qui ouvre des voies à son application dans les domaines de l?environnement et du génie civil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The changing business environment demands that chemical industrial processes be designed such that they enable the attainment of multi-objective requirements and the enhancement of innovativedesign activities. The requirements and key issues for conceptual process synthesis have changed and are no longer those of conventional process design; there is an increased emphasis on innovative research to develop new concepts, novel techniques and processes. A central issue, how to enhance the creativity of the design process, requires further research into methodologies. The thesis presentsa conflict-based methodology for conceptual process synthesis. The motivation of the work is to support decision-making in design and synthesis and to enhance the creativity of design activities. It deals with the multi-objective requirements and combinatorially complex nature of process synthesis. The work is carriedout based on a new concept and design paradigm adapted from Theory of InventiveProblem Solving methodology (TRIZ). TRIZ is claimed to be a `systematic creativity' framework thanks to its knowledge based and evolutionary-directed nature. The conflict concept, when applied to process synthesis, throws new lights on design problems and activities. The conflict model is proposed as a way of describing design problems and handling design information. The design tasks are represented as groups of conflicts and conflict table is built as the design tool. The general design paradigm is formulated to handle conflicts in both the early and detailed design stages. The methodology developed reflects the conflict nature of process design and synthesis. The method is implemented and verified through case studies of distillation system design, reactor/separator network design and waste minimization. Handling the various levels of conflicts evolve possible design alternatives in a systematic procedure which consists of establishing an efficient and compact solution space for the detailed design stage. The approach also provides the information to bridge the gap between the application of qualitative knowledge in the early stage and quantitative techniques in the detailed design stage. Enhancement of creativity is realized through the better understanding of the design problems gained from the conflict concept and in the improvement in engineering design practice via the systematic nature of the approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Convective transport, both pure and combined with diffusion and reaction, can be observed in a wide range of physical and industrial applications, such as heat and mass transfer, crystal growth or biomechanics. The numerical approximation of this class of problemscan present substantial difficulties clue to regions of high gradients (steep fronts) of the solution, where generation of spurious oscillations or smearing should be precluded. This work is devoted to the development of an efficient numerical technique to deal with pure linear convection and convection-dominated problems in the frame-work of convection-diffusion-reaction systems. The particle transport method, developed in this study, is based on using rneshless numerical particles which carry out the solution along the characteristics defining the convective transport. The resolution of steep fronts of the solution is controlled by a special spacial adaptivity procedure. The serni-Lagrangian particle transport method uses an Eulerian fixed grid to represent the solution. In the case of convection-diffusion-reaction problems, the method is combined with diffusion and reaction solvers within an operator splitting approach. To transfer the solution from the particle set onto the grid, a fast monotone projection technique is designed. Our numerical results confirm that the method has a spacial accuracy of the second order and can be faster than typical grid-based methods of the same order; for pure linear convection problems the method demonstrates optimal linear complexity. The method works on structured and unstructured meshes, demonstrating a high-resolution property in the regions of steep fronts of the solution. Moreover, the particle transport method can be successfully used for the numerical simulation of the real-life problems in, for example, chemical engineering.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fatigue life assessment of weldedstructures is commonly based on the nominal stress method, but more flexible and accurate methods have been introduced. In general, the assessment accuracy is improved as more localized information about the weld is incorporated. The structural hot spot stress method includes the influence of macro geometric effects and structural discontinuities on the design stress but excludes the local features of the weld. In this thesis, the limitations of the structural hot spot stress method are discussed and a modified structural stress method with improved accuracy is developed and verified for selected welded details. The fatigue life of structures in the as-welded state consists mainly of crack growth from pre-existing cracks or defects. Crack growth rate depends on crack geometry and the stress state on the crack face plane. This means that the stress level and shape of the stress distribution in the assumed crack path governs thetotal fatigue life. In many structural details the stress distribution is similar and adequate fatigue life estimates can be obtained just by adjusting the stress level based on a single stress value, i.e., the structural hot spot stress. There are, however, cases for which the structural stress approach is less appropriate because the stress distribution differs significantly from the more common cases. Plate edge attachments and plates on elastic foundations are some examples of structures with this type of stress distribution. The importance of fillet weld size and weld load variation on the stress distribution is another central topic in this thesis. Structural hot spot stress determination is generally based on a procedure that involves extrapolation of plate surface stresses. Other possibilities for determining the structural hot spot stress is to extrapolate stresses through the thickness at the weld toe or to use Dong's method which includes through-thickness extrapolation at some distance from the weld toe. Both of these latter methods are less sensitive to the FE mesh used. Structural stress based on surface extrapolation is sensitive to the extrapolation points selected and to the FE mesh used near these points. Rules for proper meshing, however, are well defined and not difficult to apply. To improve the accuracy of the traditional structural hot spot stress, a multi-linear stress distribution is introduced. The magnitude of the weld toe stress after linearization is dependent on the weld size, weld load and plate thickness. Simple equations have been derived by comparing assessment results based on the local linear stress distribution and LEFM based calculations. The proposed method is called the modified structural stress method (MSHS) since the structural hot spot stress (SHS) value is corrected using information on weld size andweld load. The correction procedure is verified using fatigue test results found in the literature. Also, a test case was conducted comparing the proposed method with other local fatigue assessment methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of a hydrologic model depends on the rainfall input data, both spatially and temporally. As the spatial distribution of rainfall exerts a great influence on both runoff volumes and peak flows, the use of a distributed hydrologic model can improve the results in the case of convective rainfall in a basin where the storm area is smaller than the basin area. The aim of this study was to perform a sensitivity analysis of the rainfall time resolution on the results of a distributed hydrologic model in a flash-flood prone basin. Within such a catchment, floods are produced by heavy rainfall events with a large convective component. A second objective of the current paper is the proposal of a methodology that improves the radar rainfall estimation at a higher spatial and temporal resolution. Composite radar data from a network of three C-band radars with 6-min temporal and 2 × 2 km2 spatial resolution were used to feed the RIBS distributed hydrological model. A modification of the Window Probability Matching Method (gauge-adjustment method) was applied to four cases of heavy rainfall to improve the observed rainfall sub-estimation by computing new Z/R relationships for both convective and stratiform reflectivities. An advection correction technique based on the cross-correlation between two consecutive images was introduced to obtain several time resolutions from 1 min to 30 min. The RIBS hydrologic model was calibrated using a probabilistic approach based on a multiobjective methodology for each time resolution. A sensitivity analysis of rainfall time resolution was conducted to find the resolution that best represents the hydrological basin behaviour.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new method for decision making that uses the ordered weighted averaging (OWA) operator in the aggregation of the information is presented. It is used a concept that it is known in the literature as the index of maximum and minimum level (IMAM). This index is based on distance measures and other techniques that are useful for decision making. By using the OWA operator in the IMAM, we form a new aggregation operator that we call the ordered weighted averaging index of maximum and minimum level (OWAIMAM) operator. The main advantage is that it provides a parameterized family of aggregation operators between the minimum and the maximum and a wide range of special cases. Then, the decision maker may take decisions according to his degree of optimism and considering ideals in the decision process. A further extension of this approach is presented by using hybrid averages and Choquet integrals. We also develop an application of the new approach in a multi-person decision-making problem regarding the selection of strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.