989 resultados para Mini-implantes
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Pós-graduação em Agronomia (Horticultura) - FCA
Resumo:
Orthodontic mini-implants are used in clinical practice to provide efficient and aesthetically-pleasing anchorage. AIM: To evaluate the hardness Vickers hardness and chemical composition of mini-implant titanium alloys from five commercial brands. METHODS: Thirty self-drilling mini-implants, six each from the following commercial brands, were used: Neodent NEO, Morelli MOR, Sin SIN, Conexão CON, and Rocky Mountain RMO. The hardness and chemical composition of the titanium alloys were performed by the Vickers hardness test and energy dispersive X-ray spectroscopy, respectively. RESULTS: Vickers hardness was significantly higher in SIN implants than in NEO, MOR, and CON implants. Similarly, VH was significantly higher in RMO implants than in MOR and NEO ones. In addition, VH was higher in CON implants than in NEO ones. There were no significant differences in the proportions of titanium and aluminum in the mini-implant alloy of the five commercial brands. Conversely, the proportion of vanadium differed significantly between CON and MOR/NEO implants. CONCLUSIONS: Mini-implants of different brands presented distinct properties of hardness and composition of the alloy.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Production of mini vegetables in organic system is a good alternative to improve profit, but there are no researches about the optimum plant density for these cultivars in Brazilian conditions. Two experiments were conducted to evaluate the production of mini lettuce cultivars in different plant densities. Experiment 1 was conducted from January 1th (sowing) to February 10th (harvesting), 2012. The experimental design was completely randomized blocks, with six treatments in factorial scheme, 3 mini lettuce cultivars (Tudela, Renoir and Sartre) x 2 spacing between plants (16 and 20 cm), with eight replications and plots (2.04 m(2)) with six rows, spaced 15 cm. Experiment 2 was conducted from June 6th (sowing) to July 18th (harvesting), 2012. The cultivars Sartre and Renoir were evaluated under four plant densities (444,444; 333,333; 266,667 and 200,000 plants ha(-1), corresponding to spacing of 15x15, 15x20, 25x15 and 25x20 cm, respectively). Eight treatments were defined by a factorial scheme 2 (cultivars) x 4 (plant densities) and arranged in a completely randomized block design, with nine replications and plots with 2.04 m2. The evaluated characteristics in both experiments were total and marketable fresh weight per plant, plant dry weight, plant diameter and height, marketable yield and discard percentage. In first experiment, during the summer, cultivar Sartre showed the highest marketable fresh weight (72 g plant(-1)). Heaviest plants (91.6 g plant(-1)) were obtained with the higher plant spacing, but the highest yield (2.51 kg m(-2)) was obtained with the smaller spacing. In winter, plants with higher total (190 g plant(-1)) and marketable (146 g planta(-1)) fresh weight were obtained with cultivar Sartre, and the same was observed in low plant density. However, the higher plant density, the higher the yield.
Resumo:
This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution.
Resumo:
The purpose of this study was to evaluate the possibility to obtaining guided bone regeneration utilizing a nonporous PTFE barrier in the osseointegrated implants, protruding from the bone level of the rabbit tíbia. The histologic characteristics of the interface between titanium implants, one group titanium-plasma coated, another group with acid-treated surfaces and the regenerated bone were also studied Twenty Screw-Vent implants were placed in tibias of five rabbits, two at the right side and two at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. ln the experimental side, the implants and adjacent bone were protected with a nonporous PTFE barrier. Histologic analysis after three months showed that all implants were in direct contact with the bane. Histologic measurements showed an average gain in bone height of the 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control defects, in the titanium plasma-spray and acid-treated implant surfaces, respectively. The results suggest that the placement of implants protruding 3 mm from crestal bone defects may result in vertical bone augmentation and the regenerated bone is able to osseointegrate implants. lt seems to be critical the use of the PTFE barrier when acid-treated surface implants are inserted
Resumo:
Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.
Resumo:
Patients infected with HIV can present several complications related to oral health. Today, the reduction of morbidity and mortality is evidenttreatment with antiviral enhances the quality of life of patients. The increase in comfort, stability, function and improving quality of life have led these patients to seek treatment with osseointegrated implants. This study aimed to discuss, based on the literature, the rehabilitation treatment with osseointegrated implants in patients HIV positive. For this we carried out a literature review including the subject in the databases: PubMed, Cochrane, ISI Dentistry and Oral Science in the last 20 years. The issue was addressed for the first time in 1998, describing a clinical case, the patient had successful rehabilitation with osseointegrated implants. However, the literature states that the indications must be carefully analyzed (2007), since there are few prospective controlled studies. There is doubt as to the use of dental implant therapy in patients with HIV-positive, and the complications are related to the patient’s systemic condition. It is essential to understand the clinical manifestations and complications of the disease before the implant therapy. It is observed that the dental implant therapy in patients with HIV positive is a predictable treatment option, it´s need an adequate control of oral and systemic conditions, and studies with larger sample, longer follow-up and randomized studies are important for evaluating the success therapy.
Resumo:
The design of implant structure is still a questioning to the professionals, while their variations can to influence of stress distribution favorably to bone. Therefore, the aim of study was to review addressing the topic of osseointegrated implants design establishing answers for the patient oral rehabilitation, according variations existing on the market. It was conducted a detailed search strategy by the PubMed/ Medline and Bireme, it was used as descriptors: “dental implants cylinder”; “dental implants thread”; “dental implants geometry”, until May 2014. From 798 articles, after review were selected 18 articles and 1 specific area book. The results were divided to compare design of implant and threads for further discussion and conclusions. Thus, conclude that the threads implants are best used because of its advantages with respect to the stress distribution and stability primary. The variations of the differents types of threads, have influence for stress distribution.
Resumo:
The aim of his study was to review the current scientific literature in order to discuss the surgical, prosthetics and psychological/psychosocial aspects during the treatment planning of edentulous patients, when a total fixed prosthesis or overdenture is indicated. To identify studies to take part in this review, a search was conducted for the following databases: PubMed, Dentistry and Oral Sciences Source, Journals@Ovid, SpringerLink, Wiley Online Library, Nature (NPG), Oxford Journals. It was used as descriptors: total fixed prostheses and overdentures. Inclusion criteria were: clinical articles, clinical case reports, case series, literature reviews and systematic reviews that addressed the study and comparison of total fixed prostheses and overdentures for a surgical- prosthetic planning. Exclusion criteria were: laboratory and in vitro studies and those whose first language was not English or Portuguese. Of a total of 454 articles, after an analysis according to inclusion and exclusion criteria, 76 articles were selected. During an implantsupported prosthesis rehabilitation with dental in edentulous patients, the use of alternative procedures appear to be effective when compared to more invasive surgical techniques, and thus, the amount of dental implants possible to install associated with prosthetic issues such as lip support, smile line, quantity and quality of mucosa, phonetics, etc., will allow an appropriate treatment planning to each clinical case