934 resultados para Metallic defects
Resumo:
Aim: To evaluate the influence of implant positioning into extraction sockets on bone formation at buccal alveolar dehiscence defects. Material and Methods: In six Labrador dogs the pulp tissue of the mesial roots of 4P4 was removed and the root canals were filled. Flaps were elevated bilaterally, the premolars hemi-sectioned and the distal roots removed. The implants were placed in contact with either the buccal (test site) or with the lingual (control site) bony wall of the extraction sockets. Healing abutments were affixed and triangular buccal bony dehiscence defects, about 2.7 mm deep and 3.5 mm wide, were then prepared. No regenerative procedures were done and a non-submerged healing was allowed. After 4 months of healing, block sections of the implant sites were obtained for histological processing and peri-implant tissue assessment. Results: After 4 months of healing, the bony crest and the coronal border of osseointegration at the test sites were located 1.71 ± 1.20 and 2.50 ± 1.21 mm apically to the implant shoulder, respectively. At the control sites, the corresponding values were 0.68 ± 0.63 and 1.69 ± 0.99 mm, respectively. The differences between test and control reached statistical significance (P < 0.05). Residual marginal bone defects were found both at the test and control sites. A statistically significant difference between test and control sites was only found at the lingual aspects (depth 2.09 ± 1.01 and 1.01 ± 0.48 mm, respectively). Similar heights of the buccal biological width were observed at both sites (about 5.1 mm). Conclusions: The placement of implants in a lingual position of the extraction sockets allowed a higher degree of bone formation at buccal alveolar dehiscence defects compared with a buccal positioning. © 2012 John Wiley & Sons A/S.
Resumo:
Among the many tissues in the human body, bone has been considered as a powerful marker for regeneration and its formation serves as a prototype model for tissue engineering based on morphogenesis. Therefore, collagen type I is one of the most useful biomaterials used in tissue engineering as extracellular matrix components capable to promote bone healing. The literature reveals excellent biocompatibility and safety due to its biological characteristics, such as biodegradability and weak antigenicity, making collagen type I the primary resource in medical applications. Thus, it was also used for tissue engineering including skin replacement, bone substitutes, and artificial blood vessels and valves. The authors describe the treatment of an abscessed apical periodontal cyst and show good outcomes of bone healing, using tissue engineering, as collagen type I matrix. © 2013 by Mutaz B. Habal, MD.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We have prepared heavy metal oxide glasses containing metallic copper nanoparticles with promising nonlinear optical properties which were determined by Z-scan and pump-probe measurements using femtosecond laser pulses. For the wavelengths within the plasmon band, we have observed saturable absorption and response times of 2.3 ps. For the other regions of the spectrum, reverse saturable absorption and lifetimes shorter than 200 fs were verified. The nonlinear refractive index is about 2.0 × 10-19 m2/W from visible to telecom region, thus presenting an enhancement effect at wavelengths near the plasmon and Cu+2 d-d band. © 2013 Springer Science+Business Media New York.
Resumo:
The correlative light-electron fractography technique combines correlative microscopy concepts to the extended depth-from-focus reconstruction method, associating the reliable topographic information of 3-D maps from light microscopy ordered Z-stacks to the finest lateral resolution and large focus depth from scanning electron microscopy. Fatigue striations spacing analysis can be precisely measured, by correcting the mean surface tilting with the knowledge of local elevation data from elevation maps. This new technique aims to improve the accuracy of quantitative fractography in fatigue fracture investigations. Microsc. Res. Tech. 76:909-913, 2013. © 2013 Wiley Periodicals, Inc.
Resumo:
The patterns of the calcium aluminate cement in bone defects experimentally induced in the femur of 12 New Zealand White rabbits were evaluated. The animals were distributed in three experimental groups, corresponding to postoperative observation periods of 15 (G15), 30 (G30) and 60 (G60) days. Clinical, surgical, radiographic and histological appraisals were made to observe the osteoinductor and osteoconductor potential of the biological material, as well as the bone integration. The calcium aluminate cement formulation was biocompatible, but has not acted as a osteoconductor or osteoinductor.
Resumo:
A total of 51,161 records of scrotal circumference measurements at 18 mo of age (SCI 8) and 17,648 records of sperm defects and breeding soundness of Nellore bulls (mean age of 22.5 mo), raised under extensive conditions, were analyzed to estimate coefficients of heritability and genetic correlations of morphological semen traits by Bayesian inference. The observed semen traits were classified as minor (MID). major (MAD), and total sperm defects (TD). The animals were classified according to breeding soundness as satisfactory and unsatisfactory potential breeders. The (co)variance components and breeding values were estimated by Gibbs sampling using the GIBBS2F90 program under an animal model that included contemporary group as fixed effect, age of animal as linear covariate, and direct additive genetic effects as random effects. Heritabilities of 0.40 ± 0.02, 0.16 ± 0.02, 0.04 ± 0.01, 0.15 ± 0.01, and 0.10 ± 0.01 were obtained for SCI8, MID, MAD, TD, and breeding soundness, respectively. The SC18 showed a positive and moderate correlation with breeding soundness (0.56 ± 0.04) and a negative and low correlation with MID (-0.23 ± 0.03), MAD (-0.16 ± 0.02), and TD (-0.24 ± 0.02). In conclusion, scrotal circumference showed the best response to selection among the traits studied and was favorably correlated with breeding soundness and sperm morphology in young Nellore bulls. © 2013 American Society of Animal Science. All rights reserved.
Resumo:
Incluye Bibliografía
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Neste trabalho é apresentado um estudo teórico da base neutro e bipolaron e estados excitados de moléculas a partir de polímeros isoeletrônicos compostos pelo Poliacetileno, Poliazina e Poliazoeteno. Os resultados obtidos, utilizando metodologia DFT e ab initio, revelam que uma boa descrição dos defeitos pode ser importante na investigação da transição isolante-metal de polímeros quase-unidimensional indicando um comportamento metálico em torno do nível de Fermi, como mecanismo de condutividade dos polímeros. Este resultado é consistente com dados experimentais e não faz menção a metodologia Su-Schrieffer-Heeger (SSH). E mais, os resultados são consistentes com características importantes como nanodispositivo e podem ser resumidos como: (i) poderia ser usado como retificador molecular uni-direcional com uma geometria conformacional com vantagem de pequeno acoplamento, (ii) a função de Green de não-equilíbrio presente na simulação poderia corrigir de tal maneira os Poliacetileno, Poliazina e Poliazoeteno sem corrente de porta, (iii) com base nas propriedades das ligações tipo, pode ser utilizada para projetar dispositivos com aplicações em eletrônica molecular.
Resumo:
Os nanotubos de carbono e nitreto de boro são nano estruturas unidimensionais que apresentam comportamento tanto metálico quanto semicondutor, dependendo da sua quiralidade, exceto para os nanotubos de nitreto de boro que apresentam sempre características semicondutoras, caso não estejam dopados. Devido suas características eletrônicas, os nanotubos apresentam grandes possibilidades de aplicação em dispositivos de nanoeletrônica, tais como nanodiodos, nanotransistores e como elementos de interconexão, dentre outros. Por esta razão, é importante compreender como fatores externos agem sobre as propriedades de tais materiais. Um desses fatores externos é a introdução de defeitos nos nanotubos. Tais defeitos são a ausência de um ou mais átomos de carbono, pertencente ao nanotubo de carbono e, de nitrogênio ou boro, para os nanotubos de nitreto de boro, ou ainda, a substituição de átomos de carbono, nitrogênio ou boro por diferentes átomos na estrutura dos correspondentes nanotubos. Este trabalho apresenta um estudo teórico dos efeitos da introdução de defeitos, por substituição, nas propriedades eletrônicas dos nanotubos de carbono e nitreto de boro, via simulação ab-initio. Avaliam-se as estruturas de banda de energia e densidade de estados de nanotubos de carbono semicondutores e metálicos tipos armchair e zig-zag e apenas do tipo armchair para os nanotubos de nitreto de boro usando o método LACW – método das ondas cilíndricas linearizadas aumentadas. Além disso, devido a crescente importância dos nanotubos de nitreto de boro, fazemos um estudo sistematizado da estrutura eletrônica desses nanotubos, para uma supercélula formada por três células unitárias, usando dopagem intrínseca, bem como uma análise quantitativa, baseada na energia total e banda proibida, de estabilidade dessas estruturas.
Resumo:
OBJETIVO: avaliar, in vitro, a influência do clareamento dentário com gel contendo fosfato de cálcio amorfo (ACP) na resistência da união adesiva de braquetes metálicos. MÉTODOS: trinta e seis dentes incisivos bovinos foram seccionados no limite coronorradicular e tiveram suas coroas incluídas em cilindros de PVC. Os corpos de prova foram divididos em três grupos (n = 12), de acordo com a realização do tratamento clareador e tipo de gel utilizado, sendo: G1 (controle) - sem clareamento; G2 - clareamento com gel sem ACP (Whiteness Perfect, FGM); G3 - clareamento com gel contendo ACP (Nite White ACP, Discus Dental). Os grupos G2 e G3 foram submetidos a 14 ciclos de clareamento, seguidos de intervalo de espera de 15 dias para a fixação adesiva dos braquetes metálicos. O ensaio mecânico de cisalhamento foi realizado em máquina universal Kratos, com velocidade de 0,5mm/min. Após o teste mecânico, os corpos de prova foram avaliados quanto ao índice de remanescente adesivo (ARI). Os resultados foram submetidos à ANOVA, ao teste de Tukey e ao de Kruskall-Wallis (α = 5%). RESULTADOS: diferenças significativas foram observadas entre os grupos testados. O grupo controle G1 (11,1MPa) mostrou uma resistência ao cisalhamento estatisticamente superior aos grupos submetidos ao clareamento (G2 = 5,40MPa; G3 = 3,73MPa), os quais não diferiram entre si. Não se observou diferença significativa para o ARI entre os grupos estudados. CONCLUSÃO: o clareamento dentário reduz a resistência da união adesiva de braquetes metálicos, enquanto a presença de ACP no gel clareador não influencia os resultados encontrados.