490 resultados para Mechanic sutures


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with penetrating eye injuries are a very heterogeneous group both medically and economically. Since 2009, treatment involving sutures for open eye injuries and cases requiring amniotic membrane transplantation (AMT) were allocated to DRG C01B of the German diagnosis-related group system. However, given the significant clinical differences between these treatments, an inhomogeneity of costs to performance is postulated. This analysis describes case allocation problems within the G-DRG C01B category and presents solutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microvascular surgery has become an important method for reconstructing surgical defects due to trauma, tumors or after burn. The most important factor for successful free flap transfer is a well-executed anastomosis. The time needed to perform the anastomosis and the failure rate are not negligible despite the high level of operator's experience. During the history, many alternatives were tried to help the microsurgeon and to reduce the complications. A Medline literature search was performed to find articles dealing with non-suture methods of microvascular anastomosis. Many historical books were also included. The non-suture techniques can be divided into four groups based on the used mechanism of sutures: double intubation including tubes and stents, intubation-eversion including simple rings, double eversion including staples and double rings, and wall adjustement with adhesives or laser. All these techniques were able to produce a faster and easier microvascular anastomosis. Nevertheless, disadvantages of the suturless techniques include toxicity, high cost, leakage or aneurysm formation. More refinement is needed before their widespread adoption. Thus, laser-assisted microvascular anastomosis using 1,9 μm diode laser appeared to be a safe and reliable help for the microsurgeon and may be further developed in the near future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Retraction, atrophy and fatty infiltration are signs subsequent to chronic rotator cuff tendon tears. They are associated with an increased pennation angle and a shortening of the muscle fibers in series. These deleterious changes of the muscular architecture are not reversible with current repair techniques and are the main factors for failed rotator cuff tendon repair. Whereas fast stretching of the retracted musculotendinous unit results in proliferation of non-contractile fibrous tissue, slow stretching may lead to muscle regeneration in terms of sarcomerogenesis. To slowly stretch the retracted musculotendinous unit in a sheep model, two here described tensioning devices have been developed and mounted on the scapular spine of the sheep using an expandable threaded rod, which has been interposed between the retracted tendon end and the original insertion site at the humeral head. Traction is transmitted in line with the musculotendinous unit by sutures knotted on the expandable threaded rod. The threaded rod of the tensioner is driven within the body through a rotating axis, which enters the body on the opposite side. The tendon end, which was previously released (16 weeks prior) from its insertion site with a bone chip, was elongated with a velocity of 1 mm/day. Results After several steps of technical improvements, the tensioner proved to be capable of actively stretching the retracted and degenerated muscle back to the original length and to withstand the external forces acting on it. Conclusion This technical report describes the experimental technique for continuous elongation of the musculotendinous unit and reversion of the length of chronically shortened muscle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Of the several uterine compression sutures described in more recent years to treat postpartum haemorrhage (PPH), the Hayman suture offers the potential advantages that can be applied faster and easier, avoiding the performance of a lower segment hysterotomy when PPH follows a vaginal delivery. Data on efficacy and safety are limited, and long-term follow-up information are lacking. We report our experience with the Hayman suture in 11 consecutive women with massive PPH. Of these, ten were successfully treated without further interventions. One woman ultimately required a hysterectomy. Postoperative course was uncomplicated in all the cases. The median follow-up time was 11 months (range 1-19). One woman conceived spontaneously 10 months after the procedure. Our results suggest that the Hayman suture is an effective and safe treatment for PPH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The objective of the present experiment was to study the morphogenesis of the mucosal attachment to implants made of c.p. titanium. MATERIAL AND METHODS: All mandibular premolars were extracted in 20 Labrador dogs. After a healing period of 3 months, four implants (ITI Dental Implant System) were placed in the right and left sides of the mandible. A non-submerged implant installation technique was used and the mucosal tissues were secured to the conical marginal portion of the implants with interrupted sutures. The sutures were removed after 2 weeks and a plaque control program including daily cleaning of the remaining teeth and the implants was initiated. The animals were sacrificed and biopsies were obtained at various intervals to provide healing periods extending from Day 0 (2 h) to 12 weeks. The mandibles were removed and placed in the fixative. The implant sites were dissected using a diamond saw and processed for histological analysis. RESULTS: Large numbers of neutrophils infiltrated and degraded the coagulum that occupied the compartment between the mucosa and the implant during the initial phase of healing. At 2 weeks after surgery, fibroblasts were the dominating cell population in the connective tissue interface but at 4 weeks the density of fibroblasts had decreased. Furthermore, the first signs of epithelial proliferation were observed in specimens representing 1-2 weeks of healing and a mature barrier epithelium occurred after 6-8 weeks of healing. The collagen fibers of the mucosa were organized after 4-6 weeks of healing. CONCLUSION: It is suggested that the soft-tissue attachment to implants placed using a non-submerged installation procedure is properly established after several weeks following surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a male term newborn presenting with a congenital macrocephaly 3.5 standard deviations above the median, with a wide and tense anterior fontanel, splayed calvarial sutures, and muscular hypotonia. Antenatal head circumferences were repeatedly below the median. A postnatal head ultrasound showed a large right intracerebral mass with right lateral ventricle compression, right temporal horn dilation, and right frontal horn enlargement with lateral displacement. Additional imaging by computed tomography scan and magnetic resonance imaging was performed. A decompression was performed and histology, immunohistochemistry, and molecular biology supported the diagnosis of a primitive neuroectodermal tumor. A MYCN gene amplification assay remained negative. The incidence of neonatal brain tumors is between 1.4 and 4.1/100,000 live births. Their most common presentation is macrocephaly, hydrocephalus, stillbirth, or diagnosis by pre- or postnatal imaging. Although hydrocephaly and intra- or extracranial hemorrhage are the most frequent causes of congenital macrocephaly, this should be initially investigated by head ultrasound. A suspected malignancy will be confirmed by histopathology, immunohistochemistry, and molecular biology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The stability of 2 fixation techniques for the tuberosities in patients with 3- or 4-part proximal humerus fractures treated with hemiarthroplasties was compared. DESIGN: Retrospective review of a nonrandomized sequential series of patients. SETTING: Level I university orthopaedic surgery department. PATIENTS: A consecutive series of 58 patients (average age, 64 years) from 1990 to 1999 with 3- and 4-part fractures of the proximal humerus. INTERVENTION: In group 1, 31 patients were treated with either a Neer or Aequalis shoulder prosthesis using nonabsorbable sutures and no bone graft for the reattachment of the tuberosities. In group 2, 27 patients were treated with either an Aequalis or Epoca shoulder prosthesis and a combination of cable fixation and bone grafting. MAIN OUTCOME MEASUREMENTS: At follow-up (average, 32 months), radiographs were taken to confirm tuberosity fixation or degree of displacement or resorption. Functional outcome was assessed by the Constant-Murley Score. RESULTS: Significantly more dislocated tuberosities were found radiographically in group 1 (10 of 13 in total, P = 0.011), and significantly more tuberosities were resorbed in group 1 (9 of 12 in total, P = 0.012). Significant differences in functional results among healed versus failed tuberosity fixation were observed for activity of daily living (P = 0.05), range of motion (P = 0.002), strength (P = 0.01), the total score (P = 0.008), and the passive rotation amplitude (P = 0.04). CONCLUSION: In hemiarthroplasties for proximal humeral fractures, the reattachment of the tuberosities with cable wire and bone grafting gives consistently better radiographic and functional results than with suture fixation alone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the influence of flap tension on the tearing characteristics of mucosal tissue samples in relation to various suture and needle characteristics. MATERIAL AND METHODS: Lining and masticatory mucosal tissue samples obtained from pig jaws were prepared for in vitro testing. Tension tearing diagrams of 60 experiments were traced for 3-0, 5-0 and 7-0 sutures with applied forces up to 20 N. In the second part, the same experiments were repeated with 100 diagrams to test the influence of needle characteristics with 5-0 and 6-0 sutures using only gingival tissue samples. RESULTS: 3-0 sutures mainly lead to tissue breakage at an average of 13.4 N. In contrast, 7-0 sutures only resulted in breakage of the thread at a mean applied force of 3.7 N. With 5-0 sutures, both events occurred at random at a mean force of 14.6 N. Irrespective of the needle characteristics, the mean breaking force for gingival samples with 5-0 and 6-0 sutures was approximately 10 N. CONCLUSIONS: Tissue trauma may be reduced by choosing finer suture diameters, because thinner (6-0, 7-0) sutures lead to thread breakage rather than tissue breakage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Suburethral slings are commonly used for the surgical treatment of female stress incontinence; occasionally they can cause erosion and dyspareunia. OBJECTIVES: The primary aim of this study is to determine the outcome after reclosure of the vaginal epithelium for suburethral sling erosion. Sexual function was assessed before and after intervention using the Female Sexual Function Index (FSFI) questionnaire. DESIGN, SETTING, AND PARTICIPANTS: This was a prospective case-controlled study in which, between December 2005 and December 2007, we included patients who were referred to the Department of Urogynaecology because of vaginal erosion after suburethral sling insertion for urinary stress incontinence. For evaluation of sexual function, all patients filled in an FSFI questionnaire before intervention and at follow-up. All patients underwent gynaecological examination including colposcopy, and the site and size of the defect were noted. INTERVENTION: The edge of the vaginal epithelium was trimmed, mobilized, and closed with interrupted vertical Vicryl mattress sutures in a single layer. MEASUREMENTS: FSFI questionnaire and clinical findings. RESULTS AND LIMITATIONS: Twenty-one patients were included in the study. Eighteen patients with larger defects were operated on, and three defects healed after topical application of estrogen cream. In 16 patients, the defect had healed at follow-up; two patients with persisting defects were brought back to surgery and the procedure was repeated, paying particular attention to tension-free adaptation of vaginal tissue. In one patient, partial sling removal was performed after the second failed intervention. The domains of desire (p<0.0001), arousal (p<0.0003), lubrication (p<0.0001), satisfaction (p<0.0130), and pain (p<0.0001) improved significantly. Orgasm remained unchanged (p=0.4130; all two-tailed t-test). CONCLUSION: Suburethral erosion can be treated effectively by resuturing. Sexual function is improved in regard to desire, arousal, lubrication, satisfaction, and pain, but not orgasm. In septic patients and patients with a history of radiation, grossly infected tissue, or severe pain, excision of the mesh needs to be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: To present a novel, minimally invasive strabismus surgery (MISS) technique for rectus muscle posterior fixation. METHODS: This study reports the results of 32 consecutive MISS rectus muscle posterior fixation surgeries performed on 19 patients by applying only two small L-shaped openings where the two retroequatorial scleromuscular sutures were placed. RESULTS: On the first postoperative day, in primary position, redness was hardly visible in 16 eyes (50%) and only moderate redness was visible in 6 eyes (19%). No serious complication occurred. Preoperative visual acuity and refraction remained unchanged at 6 months (p > 0.1). The preoperative convergence excess (n = 13) decreased from 10.3 +/- 4.1 to 5.2 +/- 4.0 degrees at 6 months (p < 0.005). In all patients operated on for gaze incomitance (n = 6) improvement was achieved at 6 months. CONCLUSIONS: This study shows that keyhole minimal-dissection rectus muscle posterior fixation surgery is feasible and effective to improve ocular alignment. The MISS technique seems to be superior in the direct postoperative period since only minimal conjunctival swelling and no corneal complications were observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: There is a lack of studies about how to proceed surgically in rare strabismus diseases. It was the aim of this study to inteview experienced German-speaking strabismologists about how they perform surgery in rare but also some frequent strabismic conditions. The focus was on the choice of the technique, the timing, and the dosage. METHOD: A validated questionnaire was sent to 11 experienced strabismus surgeons. It contained questions about the following topics: congenital fibrosis syndrome, Jaentsch-Brown syndrome, intermittent exotropia, maximum dosage for rectus muscle surgery, Kestenbaum surgery, sixth nerve palsy, heterophorias, myokymia of the superior oblique muscle, thyroid endocrine orbitopathy, dissociated vertical deviation, adjustable sutures, advancement of previously recessed rectus muscles, retroequatorial myopiexia, and congenital esotropia. RESULTS: Ten experts answered the questionnaire (91 %). There was a large consent for many topics. However, for many procedures there was disagreement about the dosage and the timing. Since some questions addressed rare diseases and many strabismologists use only certain types of surgical procedures, some questions could only be answered by a few surgeons. CONCLUSIONS: German-speaking strabismologist show a large consensus about the type of surgical procedure to use, but often disagree about the dosage and timing of the operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To describe an alternative method for the treatment of non-responsive self-mutilation injuries in three dogs after carpal/tarsal arthrodesis. STUDY DESIGN: Case series ANIMALS: Two dogs with carpal injury and one dog with tarsal injury treated by arthrodesis METHODS: All dogs developed self-mutilation injuries due to licking and/or chewing of the toes within 21-52 days of surgery. Clinical signs did not resolve within one week after conservative treatment with wound debridement and protective bandages. Following general anaesthesia, a deep horseshoe-shaped skin incision, including the subdermal tissue, was performed proximal to the self-mutilation injury transecting the sensory cutaneous afferent nerves. The skin incision was closed with simple interrupted sutures. RESULTS: All wounds healed without complication. Self-mutilation resolved completely within 24 hours after surgery in all dogs. No recurrence was observed (5 months to 3 years). CONCLUSION: Non-selective cutaneous sensory neurectomy may lead to resolution of self-mutilation following arthrodesis in dogs. CLINICAL RELEVANCE: Failure of conservative treatment in self-mutilation injuries often leads to toe or limb amputation as a last resort. The technique described in this case series is a simple procedure that should be considered prior to amputation. The outcome of this procedure in dogs self-multilating due to neurological or behavioral disturbances unrelated to carpal or tarsal arthrodesis is not known.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The aim of the study was to clinically and histologically evaluate the healing of human intrabony defects treated with open flap surgery (OFD) and application of a new, resorbable, fully synthetic, unsintered, nanocrystalline, phase-pure hydroxyapatite (nano-HA). MATERIALS AND METHODS Six patients, each of them displaying very advanced intrabony defects around teeth scheduled for extraction due to advanced chronic periodontitis and further prosthodontic considerations, were included in the study. Following local anaesthesia, mucoperiosteal flaps were reflected; the granulation tissue was removed, and the roots were meticulously debrided by hand and ultrasonic instruments. A notch was placed at the most apical extent of the calculus present on the root surface or at the most apical part of the defect (if no calculus was present) in order to serve as a reference for the histological evaluation. Following defect fill with nano-HA, the flaps were sutured by means of mattress sutures to allow primary intention healing. At 7 months after regenerative surgery, the teeth were extracted together with some of their surrounding soft and hard tissues and processed for histological analysis. RESULTS The postoperative healing was uneventful in all cases. At 7 months following surgery, mean PPD reduction and mean CAL gain measured 4.0 ± 0.8 and 2.5 ± 0.8 mm, respectively. The histological analysis revealed a healing predominantly characterized by epithelial downgrowth. Limited formation of new cementum with inserting connective tissue fibers and bone regeneration occurred in three out of the six biopsies (i.e. 0-0.86 and 0-1.33 mm, respectively). Complete resorption of the nano-HA was found in four out of the six biopsies. A few remnants of the graft particles (either surrounded by newly formed mineralized tissue or encapsulated in connective tissue) were found in two out of the six biopsies. CONCLUSION Within their limits, the present results indicate that nano-HA has limited potential to promote periodontal regeneration in human intrabony defects. CLINICAL RELEVANCE The clinical outcomes obtained following surgery with OFD + nano-HA may not reflect true periodontal regeneration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

What's known on the subject? and What does the study add? The EndoSew® prototype was first tested in a porcine model several years ago. The investigators found it both simple to master and reliable, its greatest advantage being a 2.4-fold time saving compared with straight laparoscopic suturing. In addition to that publication, there is a single case report describing the performance of an open EndoSew® suture to close parts (16 cm) of an ileal neobladder. The time for suturing the 16 cm ileum was 25 min, which is in line with our experience. The knowledge on this subject is limited to these two publications. We report on the first consecutive series of ileal conduits performed in humans using the novel prototype sewing device EndoSew®. The study shows that the beginning and the end of the suture process represent the critical procedural steps. It also shows that, overall, the prototype sewing machine has the potential to facilitate the intracorporeal suturing required in reconstructive urology for construction of urinary diversions. Objective To evaluate the feasibility and safety of the novel prototype sewing device EndoSew® in placing an extracorporeal resorbable running suture for ileal conduits. Patients and Methods We conducted a prospective single-centre pilot study of 10 consecutive patients undergoing ileal conduit, in whom the proximal end of the ileal conduit was closed extracorporeally using an EndoSew® running suture. The primary endpoint was the safety of the device and the feasibility of the sewing procedure which was defined as a complete watertight running suture line accomplished by EndoSew® only. Watertightness was assessed using methylene blue intraoperatively and by loopography on postoperative days 7 and 14. Secondary endpoints were the time requirements and complications ≤30 days after surgery. Results A complete EndoSew® running suture was feasible in nine patients; the suture had to be abandoned in one patient because of mechanical failure. In three patients, two additional single freehand stitches were needed to anchor the thread and to seal tiny leaks. Consequently, all suture lines in 6/10 patients were watertight with EndoSew® suturing alone and in 10/10 patients after additional freehand stitches. The median (range) sewing time was 5.5 (3–10) min and the median (range) suture length was 4.5 (2–5.5) cm. There were no suture-related complications. Conclusions The EndoSew® procedure is both feasible and safe. After additional freehand stitches in four patients all sutures were watertight. With further technical refinements, EndoSew® has the potential to facilitate the intracorporeal construction of urinary diversions.