999 resultados para Mean values


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Microalbuminuria may reflect diffuse endothelial damage. Considering that diabetes and hypertension cause vasculopathy, we investigated associations of albumin-to-creatinine ratio (ACR) with plasma glucose and blood pressure levels in high-risk subjects for metabolic syndrome. Methods: A sample of 519 (246 men) Japanese-Brazilians (aged 60 ± 11 years), who participated in a population-based study, had their ACR determined in a morning urine specimen. Backward models of multiple linear regression were created for each gender including log-transformed values of ACR as dependent variable; an interaction term between diabetes and hypertension was included. Results: Macroalbuminuria was found in 18 subjects. ACR mean values for subjects with normal glucose tolerance, impaired fasting glycemia, impaired glucose tolerance and diabetes were 9.9 ± 6.0, 19.0 ± 35.4, 20.7 ± 35.4, and 33.9 ± 55.0 mg/g, respectively. Diabetic subjects showed higher ACR than the others (p < 0.05). An increase in the proportion of albuminuric subjects was observed as glucose metabolism deteriorated (4.9, 17.0, 23.0 and 36.0%). Stratifying into 4 groups according to postchallenge glycemia (< 7.8 mmol/l, n = 9 1; ≥ 7.8 mmol/l, n = 4 10) and hypertension, hypertensive and glucose-intolerant subgroups showed higher ACR values. ACR was associated with gender, waist circumference, blood pressure, plasma glucose and triglyceride (p < 0.05); albuminuric subjects had significantly higher levels of such variables than the normoalbuminuric ones. In the final models of linear regression, systolic blood pressure and 2-hour glycemia were shown to be independent predictors of ACR for both genders (p < 0.05). In men, also waist was independently associated with ACR. No interaction was detected between diabetes and hypertension. Conclusions: These findings suggest that both glucose intolerance and hypertension could have independent but not synergistic effects on endothelial function - reflected by albumin loss in urine. Such hypothesis needs to be confirmed in prospective studies. © 2004 Dustri-Verlag Dr. K. Feistle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Quantitative analysis of normal values of motor unit action potentials duration and amplitude of muscles tireoaritenoideus (TA), cricotireoideus (CT), cricoaritenoideus lateralis (CAL), and cricoaritenoideus posterioris (CAP) was performed in 14 adult normal Brazilian volunteers. The recordings were obtained by percutaneously inserted concentric needle electrode. Different motor unit action potentials were manually selected in each muscle for quantitative computerized analysis of duration and amplitude. The mean values for duration and amplitude were respectively 3.8 ms and 413 μV for TA, 4.9 ms and 585 μV for CT, 4.1 ms and 388 μV for CAL and 4.5 ms and 475 μV in CAP. There were no similar reports of normal values of motor unit action potentials in Brazilian subjects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The objective of this study was to test the following hypothesis: the silica coating on ceramic surface increases the bond strength of resin cement to a ceramic. Materials and Methods: In-Ceram Alumina blocks were made and the ceramic surface was treated: G1 - sandblasting with 110-μm aluminum oxide particles; G2 - Rocatec System: tribochemicai silica coating (Rocatec-Pre powder + Rocatec-Plus powder + Rocatec-Sil); G3 - CoJet System: silica coating (CoJet-Sand) + ESPE-Sil. The ceramic blocks were cemented to composite blocks with Panavia F resin cement (under a load of 750 g/1 min). The cemented blocks were stored in distilled water at 37°C for 7 days and sectioned along the x and y axes with a diamond disk. Samples with an adhesive area of ca 0.8 mm 2 (n = 45) were obtained. The samples were attached to an adapted device for the microtensile test, which was performed in a universal testing machine (EMIC) at a crosshead speed of 1 mm/min. Results: The obtained results were submitted to ANOVA and Tukey's test. Mean values of tensile strength (MPa) and standard deviation values were: (G1) 16.8 ± 3.2; (G2) 30.6 ± 4.5; (G3) 33.0 ± 5.0. G2 and 63 presented greater tensile strength than G1. There was no significant difference between G2 and G3. All the failures took place at the ceramic/resin cement interface. Conclusion: The silica coating (Rocatec or CoJet systems) of the ceramic surface increased the bond strength between the Panavia F resin cement and alumina-based ceramic.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigated the flexural strength of eight fiber posts (one carbon fiber, one carbon/quartz fiber, one opaque quartz fiber, two translucent quartz fiber, and three glass fiber posts). Eighty fiber posts were used and divided into eight groups (n = 10): G1: C-POST (Bisco); G2: ÆSTHETI-POST (Bisco); G3: ÆSTHETI-PLUS (Bisco); G4: LIGHT-POST (Bisco); G5: D.T. LIGHT-POST (Bisco); G6: PARAPOST WHITE (Coltene); G7: FIBERKOR (Pentron); G8: REFORPOST (Angelus). All of the samples were tested using the three-point bending test. The averages obtained were submitted to the ANOVA and to Tukey's test (p < 0.05). The mean values (MPa) of the groups ÆSTHETI-POST - carbon/ quartz fiber post (Bisco) and ÆSTHETI-PLUS - quartz fiber post (Bisco) were statistically similar and higher than the mean values of the other groups. The mean values of the groups C-POST - carbon fiber post (Bisco), LIGHT-POST - translucent quartz fiber post (Bisco), D.T. LIGHT-POST - double tapered translucent quartz fiber post (Bisco), PARAPOST WHITE - glass fiber post (Coltene) and FIBREKOR - glass fiber post (Pentron) were similar and higher than the group REFORPOST - glass fiber post (Angelus). Copyright © 2005 by the American Association of Endodontists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate in vitro the antimicrobial activity of glass ionomer (GIC) and zinc oxide-eugenol (ZOE) cements against Candida albicans. Standardized GIC and ZOE specimens were maintained in contact with C. albicans suspension (1 x 10(6) cells/ml) at 37 degrees C for 24 h, 48 h or 7 days. A control group without any testing cement was included. After the incubation period, aliquots of 0.1 ml were plated on Sabouraud's agar, and then the number of colonies was counted. The results were expressed as values of logarithms of colony-forming units per milliliter (log CFU/mL) and were analyzed statistically by Kruskal-Wallis ANOVA. After 48 h of incubation, the ZOE group presented no growth of C. albicans. GIC and control groups presented similar mean values at all tested periods. According to the results obtained, it could be concluded that, under the experimental conditions, ZOE cement was more effective in vitro against C. albicans than GIC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The objective of this study was to verify the effect of cyclic compressive loading on the shear bond strength of an adhesive system following collagen removal. Materials and Methods: Sixty bovine teeth were divided into 4 groups based on the adhesive procedure used: groups 1 and 2 - etching with 35% phosphoric acid and application of the Single Bond adhesive system; groups 3 and 4 - after etching, a 10% sodium hypochlorite solution was applied for 1 min before the application of the adhesive. In all the specimens, a Z100 resin cylinder was built up over the bond area. Groups 2 and 4 were submitted to 500,000 cycles with a load of 100 N. Results: The mean values for the shear bond test (MPa) were: group 1: 7.37 ± 1.15; group 2: 5.72 ± 1.66; group 3: 5.95 ± 1.21; group 4: 3.66 ± 1.12. There was no difference between groups 1 and 2 (p > 0.01). Between groups 1 and 3, 2 and 4, and 3 and 4 there was a significant difference (p < 0.01). The majority of the specimens demonstrated an adhesive failure. Conclusion: The application of sodium hypochlorite on dentin decreased the values of shear bond strength, as did the load cycling in the group treated with sodium hypochlorite.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The reproducibility of measurements of alveolar bone loss on radiographs may be a problem on epidemiologic studies, as they are based on comparisons of the diagnosis of various examiners. The aim of the present research paper was to assess the inter- and intra-examiner reproducibility of measurements of the interproximal alveolar bone loss on non-manipulated digital radiographs and after the application of image filters. Five Oral Radiologists measured the distance between the cementoenamel junction (CEJ) to the alveolar crest or to the deepest point of the bony defect on 12 interproximal digital radiographs of molars and bicuspids of a dry human skull. The digital manipulation and the linear measurements were obtained with the Trophy Windows software (Throphy®). For each image, six different versions were created: 1) non-manipulated; 2) bright-contrast adjustment; 3) negative; 4) negative with brightness-contrast adjustment; 5) pseudo-colored; 6) pseudo-colored with brightness-contrast adjustment. In order to prevent interpretation bias because of the repetition of measurements, the examiners measured the radiographs in a random sequence. The two-way ANOVA test at 5% level of significance to compare the means of readings of the same operator with each filter indicated p<0.05 for the majority of operators, while the comparison between the mean values of operators using the same filter indicated p>0.05 for all filters. Based on the results, we concluded that linear measurements of interproximal alveolar bone loss on digital radiographs are highly reproducible among examiners. Nevertheless, the application of image filters significantly influenced the degree of intra-examiner reproducibility. Some filters even reduced the reproducibility of intra-examiner readings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Related data to the diameters of the pelvis from 72 Aotus azarai infulatus, owl monkeys, 42 adult males and 30 adult non-pregnant females, were obtained in vivo by ventrodorsal projection radiographic exams, correlated with sex, the measures of the body and their origin. The mean values of the body length (30.94 cm), tail length (35.63 cm), thoracic perimeter (18.97 cm), hip perimeter (17.11 cm) and the weight (0.96 Kg) were verified. The radiographic images were digitalized and measured, and the mean values were 1.41 cm for the superior biiliac diameter; 1.58 cm for the inferior biiliac diameter; 1.97 cm for the medium biiliac diameter; 2.64 cm for the right diagonal diameter; 2.66 cm for the left diagonal diameter; 2.48 cm for the sacrum-pubic diameter; 3.85 cm 2 for the inlet pelvic area. In conclusion, the pelvis from males and females Aotus azarai infulatus can be classified as dolicopelvic and there is pelvic sexual dimorphism in adult owl monkeys (Aotus azarai infulatus).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The concentration of total protein measured by photocolorimetric methodology and reported as units per 100 mg of tissue decreased from the initial segment to the cauda epididymidis of the Golden hamster, being significant the numeric difference observed between these two regions. This observation was related with an increased synthesis and secretion of proteins to the lumen in proximal segments of the epididymidis duct, mainly in initial segment, as proposed for other rodents. LDH activity was higher in initial segment and distal cauda than in the caput and corpus epididymidis, although no significant differences in mean values had been observed. The high LDH activity observed in initial segment and cauda epididymidis of hamster had been related to an expressive epithelium metabolic activity presented in these regions. This metabolic activity help to guarantee the survival of spermatozoa stored in cauda epididymidis. Furthermore, lower LDH activity noted in the caput and corpus epididymidis might be related with a progressive reduction of glycolysis in initial maturation step of spermatozoa mainly verified in corpus epididymidis. © 2007 Sociedad Chilena de Anatomía.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate, at different times, the diametral tensile strength (DTS) of dual-curing resin cements that were not photopolymerized. METHOD AND MATERIALS: Equal amounts of base and catalyst pastes of Panavia F (Kuraray), Variolink II (Vivadent), Rely X (3M ESPE), and Enforce (Dentsply) were mixed and inserted into cylindrical molds (4 x 2 mm) (n = 10). Cements were not photopolymerized. DTS test was performed in a testing machine at 30 minutes, 1 hour, 24 hours, and 7 days. The specimens were stored in light-proof containers with distilled water at 37 degrees C until the time of assay. An autopolymerizing resin cement (Cement-It, Jeneric Pentron) and a zinc phosphate cement served as controls. One-way analysis of variance (ANOVA) and Tukey test were performed separately for each cement and for each time (P <.05). RESULTS: All cements showed an increase in DTS when tested at 1 and 24 hours. Tests at 24 hours and 7 days revealed no statistically significant differences. In all groups, the zinc phosphate cement had the lowest DTS mean values (2.1 MPa, 3.6 MPa, 6.5 MPa, and 6.9 MPa), while Cement-It (35.1 MPa, 33.6 MPa, 46.9 MPa, and 46.3 MPa) and Enforce (31.9 MPa, 31.7 MPa, 43.4 MPa, and 47.6 MPa) presented the highest DTS mean values. CONCLUSION: All cements presented maximal strength at 24 hours. The dual-curing resin cements, even when nonphotopolymerized, demonstrated higher DTS than the zinc phosphate cement and similar or lower values than the autopolymerizing resin cement.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Casearia sylvestris (Flacourtiaceae) is a plant which grows in wild and has been widely used in folk medicine. In this study, clastogenic/aneugenic properties of Casearia sylvestris crude ethanolic extract were evaluated using in vivo chromosomal aberrations (CAs) and micronucleus (MN) assays in rodents. The animals were treated by gavage with 3 concentrations of the extract: 150, 300 and 500 mg/kg body weight. Bone marrow cells from Wistar rats were collected 24 h after having been submitted to the MN and CAs test. Peripheral blood cells from Swiss mice were collected 48 and 72 h after having been submitted to the MN test. The results show that C. sylvestris extract does not induce a significant increase in mean values for micronucleated polychromatic erythrocytes (MNPCE) in Swiss mice and Wistar rats, or CAs in rat bone marrow cells, at the 3 tested doses, indicating that the extract showed no clastogenic/aneugenic effects on chromosomes of the rodent cells tested. © 2007 The Japan Mendel Society.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The indirect adhesive procedures constitute recently a substantial portion of contemporary esthetic restorative treatments. The resin cements have been used to bond tooth substrate and restorative materials. Due to recently introduction of the self-bonding resin luting cement based on a new monomer, filler and initiation technology has become important to study the degree of conversion of these new materials. In the present work the polymerization reaction and the filler content of dual-cured dental resin cements were studied by means of infra-red spectroscopy (FT-IR) and thermogravimetry (TG). Twenty specimens were made in a metallic mold (8 mm diameter × 1 mm thick) from each of 2 cements, Panavia® F2.0 (Kuraray) and RelyX™ Unicem Applicap (3M/ESPE). Each specimen was cured with blue LED with power density of 500 mW/cm 2 for 30 s. Immediately after curing, 24 and 48 h, and 7 days DC was determined. For each time interval 5 specimens were pulverized, pressed with KBr and analyzed with FT-IR. The TG measurements were performed in Netzsch TG 209 under oxygen atmosphere and heating rate of 10°C/min from 25 to 700°C. A two-way ANOVA showed DC (%) mean values statistically significance differences between two cements (p < 0.05). The Tukey's test showed no significant difference only for the 24 and 48 h after light irradiation for both resin cements (p > 0.05). The Relx-Y™ Unicem mean values were significantly higher than Panavia® F 2.0. The degree of conversion means values increasing with the storage time and the filler content showed similar for both resin cements. © 2009 Pleiades Publishing, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the hardness of a dental composite resin submitted to temperature changes before photo-activation with two light-curing unite (LCUs). Five samples (4 mm in diameter and 2 mm in thickness) for each group were made with pre-cure temperatures of 37, 54, and 60°C. The samples were photo-activated with a conventional quartz-tungsten-halogen (QTH) and blue LED LCUs during 40 s. The hardness Vickers test (VHN) was performed on the top and bottom surfaces of the samples. According to the interaction between light-curing unit and different pre-heating temperatures of composite resin, only the light-curing unit provided influences on the mean values of initial Vickers hardness. The light-curing unit based on blue LED showed hardness mean values more homogeneous between the top and bottom surfaces. The hardness mean values were not statistically significant difference for the pre-cure temperature used. According to these results, the pre-heating of the composite resin provide no influence on Vickers hardness mean values, however the blue LED showed a cure more homogeneous than QTH LCU. © 2009 Pleiades Publishing, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hemoglobinopathies were included in the Brazilian Neonatal Screening Program on June 6, 2001. Automated high-performance liquid chromatography (HPLC) was indicated as one of the diagnostic methods. The amount of information generated by these systems is immense, and the behavior of groups cannot always be observed in individual analyses. Three-dimensional (3-D) visualization techniques can be applied to extract this information, for extracting patterns, trends or relations from the results stored in databases. We applied the 3-D visualization tool to analyze patterns in the results of hemoglobinopathy based on neonatal diagnosis by HPLC. The laboratory results of 2520 newborn analyses carried out in 2001 and 2002 were used. The Fast, F1, F and A peaks, which were detected by the analytical system, were chosen as attributes for mapping. To establish a behavior pattern, the results were classified into groups according to hemoglobin phenotype: normal (N = 2169), variant (N = 73) and thalassemia (N = 279). 3-D visualization was made with the FastMap DB tool; there were two distribution patterns in the normal group, due to variation in the amplitude of the values obtained by HPLC for the F1 window. It allowed separation of the samples with normal Hb from those with alpha thalassemia, based on a significant difference (P > 0.05) between the mean values of the Fast and A peaks, demonstrating the need for better evaluation of chromatograms; this method could be used to help diagnose alpha thalassemia in newborns.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the transmittance of seven different composite resins. Ten specimens were prepared (10 mm diameter, 2 mm thickness) for each experimental group, as follows: G1- Charisma® A 2 (Heraeus-Kulzer); G2- Filtek™ Supreme A 2E (3M/ESPE); G3- Filtek™ Supreme A2B (3M/ESPE); G4-Filtek™ Supreme YT (3M/ESPE); G5- Esthet-X® A2 (Dentsply); G6- Esthet-X® YE (Dentsply); G7- Durafill® A 2 (Heraeus-Kulzer) and G8- Filtek™ Z-100 A2 (3M/ESPE). The transmittance mode was measured using a UV-visible spectrophotometer (Cary Instruments) at 400-760 nm. The specimens were evaluated at three different times: zero hour (initial), 24 hours and 10 days after immersion in artificial saliva. The differences in transmittance were determined by two-way analysis of variance (ANOVA) and Tukey's test. The various composite resins showed significant differences in the wavelength dependence of transmittance. The mean values of transmittance increased significantly, with wavelengths increasing from 400 to 760 nm. The performance of the experimental groups was similar in terms of immersion time, considering that at time zero and after 10 days, all the groups showed similar results, which were statistically higher than the values obtained after 24 hours of immersion. The Filtek™ Supreme YT composite resin presented the highest mean transmittance values along the wavelengths at the three measured times. Esthet-X® YE and Durafill® yielded similar mean transmittance values, which were higher than those of the other groups. This study shows that the transmittance values of composite resins are directly related with the type, size and amount of inorganic filler particles.