956 resultados para Keratoconus eyes


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this paper is to study the correlation between the intraocular pressure peaks and fluctuation detected during the water drinking test and the same parameters observed during long-term follow up. This prospective cohort study enrolled 22 eyes of 22 newly diagnosed primary open angle glaucoma patients. After an initial complete ophthalmological examination, patients were started on antiglaucoma medication and returned 4 weeks later to perform the water drinking test. Thereafter, patients were evaluated at least eight times within a period of 6-12 months. The intraocular pressure peaks and fluctuation detected during the water drinking stress test were compared with those observed during regular office visits. Spearman`s correlation coefficient and Bland-Altman Plots were used for statistical analysis. The mean age of participants was 54.3 +/- 8.2 years (+/- SD), 59% were women, and average mean deviation -10.2 +/- 4.5 dB. The mean follow-up period was 8.2 +/- 2.0 months. The average intraocular pressure peaks and fluctuation during the water drinking test were 20.0 +/- 2.9 mmHg and 40 +/- 10%, respectively, and 18.1 +/- 2.8 mmHg and 30 +/- 10% during follow up. Spearman`s correlation coefficients were significant and strong between the intraocular pressure peaks and fluctuation detected during the water drinking test and during the follow-up period (P < 0.001, rho = 0.76 and 0.82, respectively). There was good agreement between the variables. The intraocular pressure peaks and fluctuation detected during the water drinking test showed significant correlation and agreement with the pressures observed during follow-up visits. Stress tests could be used to estimate long-term intraocular pressure variation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare mechanical and ethanol epithelial removal with respect to myofibroblast development and haze formation after photorefractive keratectomy (PRK). METHODS: Seventeen rabbits underwent mechanical or ethanol debridement, and the opposite eye of each rabbit served as an unwounded control. In both groups, the epithelium was removed with a spatula and discarded. A -9.00-diopter PRK was performed in each eye. The level of haze in each cornea at 4 weeks was graded at the slit-lamp microscope according to the Fantes scale. Myofibroblast generation was detected with immunocytochemistry for alpha-smooth muscle actin (alpha-SMA) and cells were quantitatively analyzed. RESULTS: No difference was noted between the two groups in alpha-SMA + myofibroblasts 4 weeks after surgery (43.6 +/- 2.0/400X field and 45.7 +/- 4.8/400X field in ethanol and mechanical groups, respectively) (P=.10). A slight difference was noted but did not reach statistical significance with regard to stromal haze between ethanol and mechanical groups (2.0 +/- 0.5 and 2.3 +/- 0.4, respectively, P=.063). The ethanol and mechanical groups were statistically different when compared to controls regarding stromal haze and alpha-SMA+ cells (P <.0001 for all comparisons). CONCLUSIONS:No difference was noted in clinical haze or myofibroblast generation between corneas that had PRK with mechanical,or ethanol epithelial debridement. [J Refract Surg., 2008;24:923-927.]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report clinical outcomes of the treatment of ocular Demodex folliculorum with oral ivermectin. DESIGN: Noncomparative, interventional case series. METHODS: Setting. Institutional. Study Population. Twenty-four eyes of 12 patients (3 male and 9 female; mean age +/- standard deviation, 50.4 +/- 21.0 years) with refractory posterior blepharitis with the presence of D. folliculorum in lash samples were enrolled in this study. Intervention. Patients were instructed to take 1 dose of oral ivermectin (200 mu g/kg). All patients were instructed to repeat the treatment after 7 days. Main outcome measures. Tear meniscus height, Schirmer I test results, noninvasive tear film break-up time (BUT), quantification of the absolute number of D. folliculorum found in the lashes, and corneal fluorescein and rose bengal staining scores were obtained from all patients 1 day before and 28 days after treatment. RESULTS: Statistical improvement was observed in the absolute number of D. folliculorum found in the lashes after the treatment with oral ivermectin. Average values of Schirmer I test results and tear film break-up time improved statistically after the treatment of oral ivermectin. No statistical improvement was observed in average lacrimal meniscus height or value of corneal fluorescein and rose bengal staining after treatment with oral ivermectin. CONCLUSIONS: Ivermectin successfully reduced the number of D. folliculorum found in the lashes of patients with refractory blepharitis. Oral ivermectin may be very useful as a complement in the treatment of D. folliculorum infestation with ocular manifestation, especially in cases of unsuccessful treatment related to patient compliance. (Am J Ophthalmol 2011;151:1030-1034. (C) 2011 by Elsevier Inc. All rights reserved.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To assess whether baseline Glaucoma Probability Score (GPS; HRT-3; Heidelberg Engineering, Dossenheim, Germany) results are predictive of progression in patients with suspected glaucoma. The GPS is a new feature of the confocal scanning laser ophthalmoscope that generates an operator-independent, three-dimensional model of the optic nerve head and gives a score for the probability that this model is consistent with glaucomatous damage. METHODS. The study included 223 patients with suspected glaucoma during an average follow-up of 63.3 months. Included subjects had a suspect optic disc appearance and/or elevated intraocular pressure, but normal visual fields. Conversion was defined as development of either repeatable abnormal visual fields or glaucomatous deterioration in the appearance of the optic disc during the study period. The association between baseline GPS and conversion was investigated by Cox regression models. RESULTS. Fifty-four (24.2%) eyes converted. In multivariate models, both higher values of GPS global and subjective stereophotograph assessment ( larger cup-disc ratio and glaucomatous grading) were predictive of conversion: adjusted hazard ratios (95% CI): 1.31 (1.15 - 1.50) per 0.1 higher global GPS, 1.34 (1.12 - 1.62) per 0.1 higher CDR, and 2.34 (1.22 - 4.47) for abnormal grading, respectively. No significant differences ( P > 0.05 for all comparisons) were found between the c-index values ( equivalent to area under ROC curve) for the multivariate models (0.732, 0.705, and 0.699, respectively). CONCLUSIONS. GPS values were predictive of conversion in our population of patients with suspected glaucoma. Further, they performed as well as subjective assessment of the optic disc. These results suggest that GPS could potentially replace stereophotograph as a tool for estimating the likelihood of conversion to glaucoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the abilities of scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) and variable corneal compensation (VCC) modes for detection of retinal nerve fiber layer (RNFL) loss in eyes with band atrophy (BA) of the optic nerve. DESIGN. Cross-sectional study. METHODS: Thirty-seven eyes from 37 patients with BA and temporal visual field defect from chiasmal compression and 40 eyes from 40 healthy subjects were studied. Subjects underwent standard automated perimetry and RNFL measurements using an SLP device equipped with VCC and ECC. Receiver operating characteristic (ROC) curves were calculated for each parameter. Pearson correlation coefficients were obtained to evaluate the relationship between RNFL thickness parameters and severity of visual field loss, as assessed by the temporal mean defect. RESULTS: All RNFL thickness parameters were significantly lower in eyes with BA compared with normal eyes with both compensation modes. However, no statistically significant differences were observed in the areas under the ROC curves for the different parameters between GDx VCC and ECC (Carl Zeiss Meditec, Inc, Dublin, California, USA). Structure-function relationships also were similar for both compensation modes. CONCLUSIONS: No significant differences were found between the diagnostic accuracy of GDx ECC and that of VCC for detection of BA of the optic nerve. The use of GDx ECC does not seem to provide a better evaluation of RNFL loss on the temporal and nasal sectors of the peripapillary retina in subjects with BA of the optic nerve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study design: Cross-sectional study. Objectives: To assess the importance of proprioceptive and vision information on different types of wheelchair seats with regard to postural control in paraplegic individuals during static posture. Setting: Centre of Rehabilitation at the University Hospital/FMRP-USP and Rehabilitation Outpatient Clinic at University Hospital/UNICAMP, Brazil. Methods: This study involved 11 individuals with paraplegia. All individuals were submitted to an evaluation of static balance with their eyes open and closed in three different types of seats: wheelchair seat, foam seat and gel seat. Balance evaluation was performed by using the Polhemus system, in which body displacements and anteroposterior and mediolateral speeds were assessed in a static seated position in the different types of seats. Data were analyzed using analysis of variance. The differences were considered at P<0.05. Results: No statistical differences were found between the three types of seats in terms of displacements and anteroposterior and mediolateral speeds, or between seats with individuals keeping their eyes open or closed (P>0.05). However, it was observed that body displacements were more prominent toward an anteroposterior than a mediolateral direction. Conclusion: This study suggests that individuals with paraplegia tend to exhibit a more anteroposterior body displacement than a mediolateral one, with no significant differences between the types of seats in both situations of eyes open and closed. Spinal Cord (2010) 48, 825-827; doi:10.1038/sc.2010.30; published online 30 March 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to investigate whether the additional sensory information could improve postural control in individuals with unilateral anterior cruciate ligament (ACL) injury. Twenty-eight individuals with unilateral ACL injury (mean age 23.6, 26 males, 2 females) and 28 healthy young control subjects (mean age 22.1 years, 26 males, 2 females) participated in this study. Postural control was evaluated with subjects single-leg standing on a force platform with eyes closed under two sensory conditions: normal sensory information and light touch to a stationary bar (applied force below 1 N). Three trials of 30 5 were performed in each single-leg stance and in each sensory condition. Mean sway amplitude and predominant frequency of center of pressure were calculated for both anterior-posterior and medial-lateral directions. Individuals with ACL injury showed greater mean sway amplitude than healthy control individuals even though the predominant frequency was similar for both groups. Additional sensory information improved postural control performance in individuals with ACL injury and healthy control, with a greater effect observed for the ACL group. Based on these results, we suggest that reduction in postural control performance in individuals with ACL injury would be due to the reduction of sensory information provided by the ACL, but when sensory information is enhanced, postural control performance improves. These results have implications for novel approaches to improve stability in individuals with ACL injury. (c) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To describe the presence of iris neovascularization in a rabbit-model of retinal neovascularization induced by the intravitreal injection of latex-derived angiogenic fraction microspheres (LAF). Materials and Methods: Eight New Zealand rabbits received one intravitreal injection of PLGA (L-lactide-coglycolide) microspheres with 50 ug of LAF in the right eye (Group A). Microspheres without the LAF (0.1 ml) were injected in controls (Group B; n = 8). Follow-up with clinical evaluation and iris fluorescein angiography was performed after 4 weeks when eyes were processed for light microscopy. Results: All eyes from Group A showed significant vascular dilation, conjunctival hyperemia and neovascularization on the iris surface, after LAF injection. No vascular changes were observed in Group B. Conclusions: The intravitreal injection of microspheres containing the LAF can induce rubeosis iridis in rabbits and could be used as a simple experimental model for iris neovascularization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To create a retinal neovascularization experimental model using intravitreal injection of microspheres loaded with latex-derived angiogenic fraction. Methods: Thirty-two albino New Zealand rabbits, divided in 4 groups of 8 animals, were enrolled in this study. Rabbits in groups I, II, and III received one intravitreal injection of PLGA (L-lactide-co-glycolide) microspheres with 10, 30, and 50 mu g of latex-derived angiogenic fraction into their right eyes, respectively, and group IV received 0.1 ml of microspheres without the angiogenic fraction. Weekly follow-up with ophthalmoscopy and fluorescein angiography was performed; the rabbits were sacrificed in the 4th week and their eyes processed for light microscopy. Results: All eyes from group I demonstrated increased retinal vascular tortuosity, observed from 14 days after injection and maintained for 28 days, otherwise without new vessels detection. All group II eyes showed vascular changes similar to group I. Fifty percent of the eyes from group II rabbits developed retinal neovascularization 21 days after injection. All eyes from group III demonstrated significant vascular tortuosity and retinal new vessels 2 weeks after injection, progressing to fibrovascular proliferation and tractional retinal detachment. No vascular changes or retinal new vessels were observed in group IV eyes. Light microscopy confirmed the existence of new vessels previously seen on fluorescein angiography, in retinal sections adjacent to the optic disc, not observed in sections at the same area in the control group. Conclusion: Thirty- and 50-mu g microspheres containing latex-derived angiogenic fraction injected into the vitreous cavity induced retinal neovascularization in rabbits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the advantages and disadvantages of the new low-addition (add) (+3.00 diopter [D]) ReSTOR multifocal IOL compared with the preceding ReSTOR model with +4.00 D add. SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Comparative case series. METHODS: Patients with a +3.00 D or +4.00 D add multifocal IOL were examined for uncorrected and distance-corrected visual acuity at distance, intermediate, and near. A defocus profile was assessed, individual reading distance and the distance for lowest intermediate visual acuity were determined. Patient satisfaction was evaluated with a standardized questionnaire. Contrast sensitivity was tested under mesopic and photopic conditions. RESULTS: Uncorrected and distance-corrected intermediate visual acuities were statistically significantly better in the +3.00 D add group (24 eyes) than in the +4.00 D add group (30 eyes); distance and near visual acuities were not different between groups. The defocus profile significantly varied between groups. The +4.00 D add group had a closer reading distance (33.0 cm) than the +3.00 D add group (43.5 cm), a closer point of lowest intermediate visual acuity (65.8 cm versus 86.9 cm) and worse lowest intermediate visual acuity (20/59 +/- 4.5 letters [SD] versus 20/48 +/- 5.5 letters). Thus, patients in the +3.00 D add group reported being more satisfied with intermediate visual acuity. The +3.00 D add group reported more glare but less halos than the +4.00 D add group; contrast sensitivity was not different. CONCLUSION: The lower addition resulted in a narrower defocus profile, a farther reading distance, and better intermediate visual acuity and thus increased patient satisfaction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: To compare the results of preoperative Nd:YAG laser anterior capsulotomy versus two-stage continuous curvilinear capsulorhexis (CCC) in phacoemulsification of eyes with white intumescent cataracts and liquefied cortex. PATIENTS AND METHODS: Twenty-three eyes with white intumescent cataract were consecutively randomized for phacoemulsification with preoperative Nd:YAG laser anterior capsulotomy (group 1, n = 11) or two-stage CCC (group 2, n = 12) procedures. Intraoperative findings and postoperative outcomes were compared using the nonparametric tests. RESULTS: Postoperative Visual acuity, mean surgical time, mean effective phacoemulsification time, and frequency of complications were not significantly different between the two groups (P > .05). Two cases in each group were converted to the extracapsular technique. Excluding these four patients, surgical time was shorter In group 1 (P = .017). CONCLUSION: Preoperative Nd:YAG laser anterior capsulotomy is a safe technique in decompressing the capsular bag before phacoemulsification of white intumescent cataracts with liquefied cortex.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the efficacy and safety of diode laser transscleral cyclophotocoagulation (DLTSC) to control intraocular pressure (IOP) in keratoprosthesis patients with uncontrolled glaucoma. Patients and Methods: Between 1993 and 2007, 18 eyes of 18 patients underwent DLTSC, either before (n = 3), during (n = I), or after (n = 14) keratoprosthesis surgery. Keratoprosthesis type 1 was used in 72%. All but one of these patients received an Ahmed Glaucoma Valve, either with or after the keratoprosthesis placement. Best-corrected visual acuity, IOP (assessed by digital palpation), number of medications, and complications were recorded preoperatively, at day 7, at 1, 3, and 6 months then every 6 months postoperatively. Results: Mean follow-tip was 26.6 +/- 19.6 months (mean +/- SD) and mean age was 50.1 +/- 15.6 years. Glaucoma was identified in 1 I eyes before keratoprosthesis surgery and in 7 eyes after. Mean postoperative IOP was significantly reduced at 6, 12, 24, 36, and 48 months after DLTSC. DLTSC was repeated in 6 eyes. At final visit, mean best-corrected visual acuity was not decreased and there were no statistically significant differences in the number of glaucoma medications. Two patients had complications after DLTSC: a conjunctival dehiscence and a fungal endophthalmitis. Conclusions: DLTSC has beneficial long-term effects in the control of IOP and can be considered in the management of keratoprosthesis patients with refractory glaucoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the proliferative behavior of the corneal and limbal epithelia after debridement on the central region of the rabbit cornea. Methods: After scraping a circular epithelial area, 5 mm in diameter, in the center of the cornea, (3)H-thymidine ((3)H-TdR) was injected intravitreally, and the rabbits killed from 1 to 49 days afterward. The cornea, together with the adjacent conjunctiva, was processed for autoradiography. Results: The regenerating epithelium at the center of the cornea exhibited high frequencies of labeled nuclei when compared to controls. The mitotic indexes for the limbus were comparable in experimental and control eyes. The unique basal stratum of the limbal epithelium exhibited quick proliferation and vertical migration in all eyes. Cells that remained labeled for four weeks or more were observed throughout the corneal epithelium, including its basal stratum, and this did not depend on epithelial damage. Conclusion: Corneal epithelium wounds are healed by sliding and proliferation of cells surrounding the epithelial gap without any evidence for the participation of the limbal epithelium. Daughter cells labeled with (3)H-TdR were visualized in all layers of the corneal epithelium up to 7 weeks after the DNA precursor injection. However, at this long interval, the only labeled cells in the limbus were in the suprabasal layers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Patients with early age-related maculopathy ( ARM) do not necessarily show obvious morphological signs or functional impairment. Many have good visual acuity, yet complain of decreased visual performance. The aim of this study was to investigate the aging effects on performance of parafoveal letter recognition at reduced contrast, and defects caused by early ARM and normal fellow eyes of patients with unilateral age-related macular degeneration (nfAMD). Methods Testing of the central visual field (8 radius) was performed by the Macular Mapping Test (MMT) using recognition of letters in 40 parafoveal target locations at four contrast levels (5, 10, 25 and 100%). Effects of aging were investigated in 64 healthy subjects aged 23 to 76 years (CTRL). In addition, 39 eyes (minimum visual acuity of 0.63; 20/30) from 39 patients with either no visible signs of ARM, while the fellow eye had advanced age-related macular degeneration (nfAMD; n=12), or early signs of ARM (eARM; n=27) were examined. Performance was expressed summarily as a ""field score"" (FS). Results Performance in the MMT begins to decline linearly with age in normal subjects from the age of 50 and 54 years on, at 5% and 10% contrast respectively. The differentiation between patients and CTRLs was enhanced if FS at 5% was analyzed along with FS at 10% contrast. In 8/12 patients from group nfAMD and in 18/27 from group eARM, the FS was statistically significantly lower than in the CTRL group in at least one of the lower contrast levels. Conclusion Using parafoveal test locations, a recognition task and diminished contrast increases the chance of early detection of functional defects due to eARM or nfAMD and can differentiate them from those due to aging alone.