997 resultados para Imaging-plate Camera
Resumo:
The functionality of adult neocortical circuits can be altered by novel experiences or learning. This functional plasticity appears to rely on changes in the strength of neuronal connections that were established during development. Here we will describe some of our studies in which we have addressed whether structural changes, including the remodeling of axons and dendrites with synapse formation and elimination, could underlie experience-dependent plasticity in the adult neocortex. Using 2-photon laser-scanning microscopes and transgenic mice expressing GFP in a subset of pyramidal cells, we have observed that a small subset of dendritic spines continuously appear and disappear on a daily basis, whereas the majority of spines persists for months. Axonal boutons from different neuronal classes displayed similar behavior, although the extent of remodeling varied. Under baseline conditions, new spines in the barrel cortex were mostly transient and rarely survived for more than a week. However, when every other whisker was trimmed, the generation and loss of persistent spines was enhanced. Ultrastructural reconstruction of previously imaged spines and boutons showed that new spines slowly form synapses. New spines persisting for a few days always had synapses, whereas very young spines often lacked synapses. New synapses were predominantly found on large, multi-synapse boutons, suggesting that spine growth is followed by synapse formation, preferentially on existing boutons. Altogether our data indicate that novel sensory experience drives the stabilization of new spines on subclasses of cortical neurons and promotes the formation of new synapses. These synaptic changes likely underlie experience-dependent functional remodeling of specific neocortical circuits.
Resumo:
INTRODUCTION: Intravoxel incoherent motion (IVIM) imaging is an MRI perfusion technique that uses a diffusion-weighted sequence with multiple b values and a bi-compartmental signal model to measure the so-called pseudo-diffusion of blood caused by its passage through the microvascular network. The goal of the current study was to assess the feasibility of IVIM perfusion fraction imaging in patients with acute stroke. METHODS: Images were collected in 17 patients with acute stroke. Exclusion criteria were onset of symptoms to imaging >5 days, hemorrhagic transformation, infratentorial lesions, small lesions <0.5 cm in minimal diameter and hemodynamic instability. IVIM imaging was performed at 3 T, using a standard spin-echo Stejskal-Tanner pulsed gradients diffusion-weighted sequence, using 16 b values from 0 to 900 s/mm(2). Image quality was assessed by two radiologists, and quantitative analysis was performed in regions of interest placed in the stroke area, defined by thresholding the apparent diffusion coefficient maps, as well as in the contralateral region. RESULTS: IVIM perfusion fraction maps showed an area of decreased perfusion fraction f in the region of decreased apparent diffusion coefficient. Quantitative analysis showed a statistically significant decrease in both IVIM perfusion fraction f (0.026 ± 0.019 vs. 0.056 ± 0.025, p = 2.2 · 10(-6)) and diffusion coefficient D compared with the contralateral side (3.9 ± 0.79 · 10(-4) vs. 7.5 ± 0.86 · 10(-4) mm(2)/s, p = 1.3 · 10(-20)). CONCLUSION: IVIM perfusion fraction imaging is feasible in acute stroke. IVIM perfusion fraction is significantly reduced in the visible infarct. Further studies should evaluate the potential for IVIM to predict clinical outcome and treatment response.
Resumo:
Image quality in magnetic resonance imaging (MRI) is considerably affected by motion. Therefore, motion is one of the most common sources of artifacts in contemporary cardiovascular MRI. Such artifacts in turn may easily lead to misinterpretations in the images and a subsequent loss in diagnostic quality. Hence, there is considerable research interest in strategies that help to overcome these limitations at minimal cost in time, spatial resolution, temporal resolution, and signal-to-noise ratio. This review summarizes and discusses the three principal sources of motion: the beating heart, the breathing lungs, and bulk patient movement. This is followed by a comprehensive overview of commonly used compensation strategies for these different types of motion. Finally, a summary and an outlook are provided.
Resumo:
The aim of this study was to illustrate the chest radiographs (CR) and CT imaging features and sequential findings of cavitary necrosis in complicated childhood pneumonia. Among 30 children admitted in the Pediatric Intensive Care Unit for persistent or progressive pneumonia, respiratory distress or sepsis despite adequate antibiotic therapy, a study group of 9 children (5 girls and 4 boys; mean age 4 years) who had the radiographic features and CT criteria for cavitary necrosis complicated pneumonia was identified. The pathogens identified were Streptococcus pneumoniae( n=4), Aspergillus( n=2), Legionella( n=1), and Staphylococcus aureus( n=1). Sequential CR and CT scans were retrospectively reviewed. Follow-up CR and CT were evaluated for persistent abnormalities. Chest radiographs showed consolidations in 8 of the 9 patients. On CT examination, cavitary necrosis was localized to 1 lobe in 2 patients and 7 patients showed multilobar or bilateral areas of cavitary necrosis. In 3 patients of 9, the cavitary necrosis was initially shown on CT and visualization by CR was delayed by a time span varying from 5 to 9 days. In all patients with cavities, a mean number of five cavities were seen on antero-posterior CR, contrasting with the multiple cavities seen on CT. Parapneumonic effusions were shown by CR in 3 patients and in 5 patients by CT. Bronchopleural fistulae were demonstrated by CT alone ( n=3). No purulent pericarditis was demonstrated. The CT scan displayed persistent residual pneumatoceles of the left lower lobe in 2 patients. Computed tomography is able to define a more specific pattern of abnormalities than conventional CR in children with necrotizing pneumonia and allows an earlier diagnosis of this rapidly progressing condition. Lung necrosis and cavitation may also be associated with Aspergillus or Legionella pneumonia in the pediatric population.
Resumo:
Coronary MR imaging is a promising noninvasive technique for the combined assessment of coronary artery anatomy and function. Anomalous coronary arteries and aneurysms can reliably be assessed in clinical practice using coronary MR imaging and the presence of significant left main or proximal multivessel coronary artery disease detected. Technical challenges that need to be addressed are further improvements in motion suppression and abbreviated scanning times aimed at improving spatial resolution and patient comfort. The development of new and specific contrast agents, high-field MR imaging with improved spatial resolution, and continued progress in MR imaging methods development will undoubtedly lead to further progress toward the noninvasive and comprehensive assessment of coronary atherosclerotic disease.
Resumo:
In recent years, modern techniques of medical imaging such as MDCT (multidetector-computed tomography) and MRI (magnetic resonance imaging) have pioneered post mortem (pm) investigations, especially in forensic medicine. Particularly pm angiography permits investigating the vascular system in a way which is not possible by performing only conventional autopsy. Beside these radiological methods, other modem visualizing techniques like the three dimensional (3D) surface scan have been implemented in order perform reconstructions of complex cases. By the use of pm imaging techniques, more objective and accurate documentations can be realized that permit an increase of quality in forensic investigations.
Resumo:
El procés de fusió de dues o més imatges de la mateixa escena en una d'única i més gran és conegut com a Image Mosaicing. Un cop finalitzat el procés de construcció d'un mosaic, els límits entre les imatges són habitualment visibles, degut a imprecisions en els registres fotomètric i geomètric. L'Image Blending és l'etapa del procediment de mosaicing a la que aquests artefactes són minimitzats o suprimits. Existeixen diverses metodologies a la literatura que tracten aquests problemes, però la majoria es troben orientades a la creació de panorames terrestres, imatges artístiques d'alta resolució o altres aplicacions a les quals el posicionament de la càmera o l'adquisició de les imatges no són etapes rellevants. El treball amb imatges subaquàtiques presenta desafiaments importants, degut a la presència d'scattering (reflexions de partícules en suspensió) i atenuació de la llum i a condicions físiques extremes a milers de metres de profunditat, amb control limitat dels sistemes d'adquisició i la utilització de tecnologia d'alt cost. Imatges amb il·luminació artificial similar, sense llum global com la oferta pel sol, han de ser unides sense mostrar una unió perceptible. Les imatges adquirides a gran profunditat presenten una qualitat altament depenent de la profunditat, i la seva degradació amb aquest factor és molt rellevant. El principal objectiu del treball és presentar dels principals problemes de la imatge subaquàtica, seleccionar les estratègies més adequades i tractar tota la seqüència adquisició-procesament-visualització del procés. Els resultats obtinguts demostren que la solució desenvolupada, basada en una Estratègia de Selecció de Límit Òptim, Fusió en el Domini del Gradient a les regions comunes i Emfatització Adaptativa d'Imatges amb baix nivell de detall permet obtenir uns resultats amb una alta qualitat. També s'ha proposat una estratègia, amb possibilitat d'implementació paral·lela, que permet processar mosaics de kilòmetres d'extensió amb resolució de centímetres per píxel.
Resumo:
Purpose. We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD). Materials and Methods. Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61 ± 10 years) were studied on a commercial 3.0 Tesla (T) whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands). T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI) was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd) (0.1 mmol/kg Gd-DTPA). Results. LGE was seen in none of the healthy subjects, however in all of the CAD patients. In CAD patients, fifty-six of 62 (90.3%) segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast. At time-interval 2, 34 of 42 (81.0%) and at time-interval 3, 29 of 39 evaluable segments (74.4%) were enhanced. Conclusion. In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects. In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30-45 minutes after administration of the contrast agent.
Resumo:
Background: CMR has recently emerged as a robust and reliable technique to assess coronary artery disease (CAD). A negative perfusion CMR test predicts low event rates of 0.3-0.5%/year. Invasive coronary angiography (CA) remains the "gold standard" for the evaluation of CAD in many countries.Objective: Assessing the costs of the two strategies in the European CMR registry for the work-up of known or suspected CAD from a health care payer perspective. Strategy 1) a CA to all patients or 2) a CA only to patients who are diagnosed positive for ischemia in a prior CMR.Method and results: Using data of the European CMR registry (20 hospitals, 11'040 consecutive patients) we calculated the proportion of patients who were diagnosed positive (20.6%), uncertain (6.5%), and negative (72.9%) after the CMR test in patients with known or suspected CAD (n=2'717). No other medical test was performed to patients who were negative for ischemia. Positive diagnosed patients had a coronary angiography. Those with uncertain diagnosis had additional tests (84.7%: stress echocardiography, 13.1%: CCT, 2.3% SPECT), these costs were added to the CMR strategy costs. Information from costs for tests in Germany and Switzerland were used. A sensibility analysis was performed for inpatient CA. For costs see figure. Results - costs.Discussion: The CMR strategy costs less than the CA strategy for the health insurance systems both, in Germany and Switzerland. While lower in costs, the CMR strategy is a non-invasive one, does not expose to radiation, and yields additional information on cardiac function, viability, valves, and great vessels. Developing the use of CMR instead of CA might imply some reduction in costs together with superior patient safety and comfort, and a better utilization of resources at the hospital level. Document introduit le : 01.12.2011
Resumo:
The South America-Antarctica plate system shows many oceanic accretionary systems and subduction zones that initiated and then stopped. To better apprehend the evolution of the system, geodynamic reconstructions (global) have been created from Jurassic (165 Ma) to present, following the techniques used at the University of Lausanne. However, additional synthetic magnetic anomalies were used to refine the geodynamics between 33 Ma and present. The reconstructions show the break up of Gondwana with oceanisation between South America (SAM) and Antarctica (ANT), together with the break off of `Andean' geodynamical units (GDUs). We propose that oceanisation occurs also east and south of the Scotian GDUs. Andean GDUs collide with other GDUs crossing the Pacific. The west coast of SAM and ANT undergo a subsequent collision with all those GDUs between 103 Ma and 84 Ma, and the Antarctic Peninsula also collides with Tierra del Fuego. The SAM-ANT plate boundary experienced a series of extension and shortening with large strike-slip component, culminating with intra-oceanic subduction leading to the presence of the `V-' and anomalies in the Weddell Sea. From 84 Ma, a transpressive collision takes place in the Scotia region, with active margin to the east. As subduction propagates northwards into an old and dense oceanic crust, slab roll-back initiates, giving rise to the western Scotia Sea and the Powell Basin opening. The Drake Passage opens. As the Scotian GDUs migrate eastwards, there is enough space for them to spread and allow a north-south divergence with a spreading axis acting simultaneously with the western Scotia ridge. Discovery Bank stops the migration of South Orkney and `collides with' the SAM-ANT spreading axis, while the northern Scotian GDUs are blocked against the Falkland Plateau and the North-East Georgia Rise. The western and central Scotia and the Powell Basin spreading axes must cease, and the ridge jumps to create the South Sandwich Islands Sea. The Tierra del Fuego-Patagonia region has always experienced mid-oceanic ridge subduction since 84 Ma. Slab window location is also presented (57-0 Ma), because of its important implication for heat flux and magmatism. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
En aquest projecte s'ha dissenyat i simulat una càmera d'ones mil·limètriques mitjançant "Spinning Reflectors" amb l'objectiu d'estudiar la qualitat de les imatges obtingudes, així com determinar la configuració de reflectors acceptable per a la nostra càmera. Per al seu disseny, s'ha realitzat el model d'una antena Cassegrain amb botzina alimentadora a FEKO i s'han simulat els diagrames de radiació corresponents als diferents angles de rotació d'ambdós reflectors al voltant de l'eix en el qual estan situats. Finalment, a partir del principi de funcionament de la nostra càmera, s'ha exposat la seva implementació física i s'ha representat en Matlab la seva PSF (Point Spread Function) i la imatge d'un objecte arbitrari d'acord amb les tècniques de formació d'imatges.
Resumo:
In type I diabetes mellitus, islet transplantation provides a moment-to-moment fine regulation of insulin. Success rates vary widely, however, necessitating suitable methods to monitor islet delivery, engraftment and survival. Here magnetic resonance-trackable magnetocapsules have been used simultaneously to immunoprotect pancreatic beta-cells and to monitor, non-invasively in real-time, hepatic delivery and engraftment by magnetic resonance imaging (MRI). Magnetocapsules were detected as single capsules with an altered magnetic resonance appearance on capsule rupture. Magnetocapsules were functional in vivo because mouse beta-cells restored normal glycemia in streptozotocin-induced diabetic mice and human islets induced sustained C-peptide levels in swine. In this large-animal model, magnetocapsules could be precisely targeted for infusion by using magnetic resonance fluoroscopy, whereas MRI facilitated monitoring of liver engraftment over time. These findings are directly applicable to ongoing improvements in islet cell transplantation for human diabetes, particularly because our magnetocapsules comprise clinically applicable materials.
Resumo:
Purpose: To evaluate the sensitivity of the perfusion parameters derived from Intravoxel Incoherent Motion (IVIM) MR imaging to hypercapnia-induced vasodilatation and hyperoxygenation-induced vasoconstriction in the human brain. Materials and Methods: This study was approved by the local ethics committee and informed consent was obtained from all participants. Images were acquired with a standard pulsed-gradient spin-echo sequence (Stejskal-Tanner) in a clinical 3-T system by using 16 b values ranging from 0 to 900 sec/mm(2). Seven healthy volunteers were examined while they inhaled four different gas mixtures known to modify brain perfusion (pure oxygen, ambient air, 5% CO(2) in ambient air, and 8% CO(2) in ambient air). Diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), and blood flow-related parameter (fD*) maps were calculated on the basis of the IVIM biexponential model, and the parametric maps were compared among the four different gas mixtures. Paired, one-tailed Student t tests were performed to assess for statistically significant differences. Results: Signal decay curves were biexponential in the brain parenchyma of all volunteers. When compared with inhaled ambient air, the IVIM perfusion parameters D*, f, and fD* increased as the concentration of inhaled CO(2) was increased (for the entire brain, P = .01 for f, D*, and fD* for CO(2) 5%; P = .02 for f, and P = .01 for D* and fD* for CO(2) 8%), and a trend toward a reduction was observed when participants inhaled pure oxygen (although P > .05). D remained globally stable. Conclusion: The IVIM perfusion parameters were reactive to hyperoxygenation-induced vasoconstriction and hypercapnia-induced vasodilatation. Accordingly, IVIM imaging was found to be a valid and promising method to quantify brain perfusion in humans. © RSNA, 2012.