894 resultados para Image sensors
Resumo:
The standard data fusion methods may not be satisfactory to merge a high-resolution panchromatic image and a low-resolution multispectral image because they can distort the spectral characteristics of the multispectral data. The authors developed a technique, based on multiresolution wavelet decomposition, for the merging and data fusion of such images. The method presented consists of adding the wavelet coefficients of the high-resolution image to the multispectral (low-resolution) data. They have studied several possibilities concluding that the method which produces the best results consists in adding the high order coefficients of the wavelet transform of the panchromatic image to the intensity component (defined as L=(R+G+B)/3) of the multispectral image. The method is, thus, an improvement on standard intensity-hue-saturation (IHS or LHS) mergers. They used the ¿a trous¿ algorithm which allows the use of a dyadic wavelet to merge nondyadic data in a simple and efficient scheme. They used the method to merge SPOT and LANDSATTM images. The technique presented is clearly better than the IHS and LHS mergers in preserving both spectral and spatial information.
Resumo:
Tripping is considered a major cause of fall in older people. Therefore, foot clearance (i.e., height of the foot above ground during swing phase) could be a key factor to better understand the complex relationship between gait and falls. This paper presents a new method to estimate clearance using a foot-worn and wireless inertial sensor system. The method relies on the computation of foot orientation and trajectory from sensors signal data fusion, combined with the temporal detection of toe-off and heel-strike events. Based on a kinematic model that automatically estimates sensor position relative to the foot, heel and toe trajectories are estimated. 2-D and 3-D models are presented with different solving approaches, and validated against an optical motion capture system on 12 healthy adults performing short walking trials at self-selected, slow, and fast speed. Parameters corresponding to local minimum and maximum of heel and toe clearance were extracted and showed accuracy ± precision of 4.1 ± 2.3 cm for maximal heel clearance and 1.3 ± 0.9 cm for minimal toe clearance compared to the reference. The system is lightweight, wireless, easy to wear and to use, and provide a new and useful tool for routine clinical assessment of gait outside a dedicated laboratory.
Resumo:
When preparing an article on image restoration in astronomy, it is obvious that some topics have to be dropped to keep the work at reasonable length. We have decided to concentrate on image and noise models and on the algorithms to find the restoration. Topics like parameter estimation and stopping rules are also commented on. We start by describing the Bayesian paradigm and then proceed to study the noise and blur models used by the astronomical community. Then the prior models used to restore astronomical images are examined. We describe the algorithms used to find the restoration for the most common combinations of degradation and image models. Then we comment on important issues such as acceleration of algorithms, stopping rules, and parameter estimation. We also comment on the huge amount of information available to, and made available by, the astronomical community.
Resumo:
GLUT2-/- mice reexpressing GLUT1 or GLUT2 in their beta-cells (RIPGLUT1 x GLUT2-/- or RIPGLUT2 x GLUT2-/- mice) have nearly normal glucose-stimulated insulin secretion but show high glucagonemia in the fed state. Because this suggested impaired control of glucagon secretion, we set out to directly evaluate the control of glucagonemia by variations in blood glucose concentrations. Using fasted RIPGLUT1 x GLUT2-/- mice, we showed that glucagonemia was no longer increased by hypoglycemic (2.5 mmol/l glucose) clamps or suppressed by hyperglycemic (10 and 20 mmol/l glucose) clamps. However, an increase in plasma glucagon levels was detected when glycemia was decreased to < or =1 mmol/l, indicating preserved glucagon secretory ability, but of reduced sensitivity to glucopenia. To evaluate whether the high-fed glucagonemia could be due to an abnormally increased tone of the autonomic nervous system, fed mutant mice were injected with the ganglionic blockers hexamethonium and chlorisondamine. Both drugs lead to a rapid return of glucagonemia to the levels found in control fed mice. We conclude that 1) in the absence of GLUT2, there is an impaired control of glucagon secretion by low or high glucose; 2) this impaired glucagon secretory activity cannot be due to absence of GLUT2 from alpha-cells because these cells do not normally express this transporter; 3) this dysregulation may be due to inactivation of GLUT2-dependent glucose sensors located outside the endocrine pancreas and controlling glucagon secretion; and 4) because fed hyperglucagonemia is rapidly reversed by ganglionic blockers, this suggests that in the absence of GLUT2, there is an increased activity of the autonomic nervous system stimulating glucagon secretion during the fed state.
Resumo:
Nanocrystalline TiO2 modified with Nb has been produced through the sol-gel technique. Nanopowders have been obtained by means of the hydrolysis of pure alkoxides with deionized water and peptization of the resulting hydrolysate with diluted acid nitric at 100 C. The addition of Nb stabilizes the anatase phase to higher temperatures. XRD spectra of the undoped and the Nb-doped samples show that the undoped sample has been almost totally converted to rutile at 600 C, meanwhile the doped samples present still a low percentage of rutile phase. Nanocrystalline powders stabilized at 600 C with grain sizes of about 17 nm have successfully been synthesized by the addition of Nb with a concentration of 2% at., which appears to be an adequate additive concentration to improve the gas sensor performances, such as it is suggested by the catalytic conversion efficiency experiments performed from FTIR measurements. FTIR absorbance spectra show that catalytic conversion of CO occurs at lower temperatures when niobium is introduced. The electrical response of the films to different concentrations of CO and ethanol has been monitored in dry and wet environments in order to test the influence of humidity in the sensor response. The addition of Nb decreases the working temperature and increases the stability of the layers. Also, large enhancement of the response time is obtained even with lower working temperatures. Moreover, humidity effects on the gas sensor response toward CO and ethanol are less important in Nb-doped samples than in the undoped ones.
Resumo:
Assessment of locomotion through simple tests such as timed up and go (TUG) or walking trials can provide valuable information for the evaluation of treatment and the early diagnosis of people with Parkinson's disease (PD). Common methods used in clinics are either based on complex motion laboratory settings or simple timing outcomes using stop watches. The goal of this paper is to present an innovative technology based on wearable sensors on-shoe and processing algorithm, which provides outcome measures characterizing PD motor symptoms during TUG and gait tests. Our results on ten PD patients and ten age-matched elderly subjects indicate an accuracy ± precision of 2.8 ± 2.4 cm/s and 1.3 ± 3.0 cm for stride velocity and stride length estimation compared to optical motion capture, with the advantage of being practical to use in home or clinics without any discomfort for the subject. In addition, the use of novel spatio-temporal parameters, including turning, swing width, path length, and their intercycle variability, was also validated and showed interesting tendencies for discriminating patients in ON and OFF states and control subjects.
Resumo:
A semisupervised support vector machine is presented for the classification of remote sensing images. The method exploits the wealth of unlabeled samples for regularizing the training kernel representation locally by means of cluster kernels. The method learns a suitable kernel directly from the image and thus avoids assuming a priori signal relations by using a predefined kernel structure. Good results are obtained in image classification examples when few labeled samples are available. The method scales almost linearly with the number of unlabeled samples and provides out-of-sample predictions.
Resumo:
Background: Variable definitions of outcome (Constant score, Simple Shoulder Test [SST]) have been used to assess outcome after shoulder treatment, although none has been accepted as the universal standard. Physicians lack an objective method to reliably assess the activity of their patients in dynamic conditions. Our purpose was to clinically validate the shoulder kinematic scores given by a portable movement analysis device, using the activities of daily living described in the SST as a reference. The secondary objective was to determine whether this device could be used to document the effectiveness of shoulder treatments (for glenohumeral osteoarthritis and rotator cuff disease) and detect early failures.Methods: A clinical trial including 34 patients and a control group of 31 subjects over an observation period of 1 year was set up. Evaluations were made at baseline and 3, 6, and 12 months after surgery by 2 independent observers. Miniature sensors (3-dimensional gyroscopes and accelerometers) allowed kinematic scores to be computed. They were compared with the regular outcome scores: SST; Disabilities of the Arm, Shoulder and Hand; American Shoulder and Elbow Surgeons; and Constant.Results: Good to excellent correlations (0.61-0.80) were found between kinematics and clinical scores. Significant differences were found at each follow-up in comparison with the baseline status for all the kinematic scores (P < .015). The kinematic scores were able to point out abnormal patient outcomes at the first postoperative follow-up.Conclusion: Kinematic scores add information to the regular outcome tools. They offer an effective way to measure the functional performance of patients with shoulder pathology and have the potential to detect early treatment failures.Level of evidence: Level II, Development of Diagnostic Criteria, Diagnostic Study. (C) 2011 Journal of Shoulder and Elbow Surgery Board of Trustees.
Resumo:
Nanocrystalline TiO2 modified with Nb has been produced through the sol-gel technique. Nanopowders have been obtained by means of the hydrolysis of pure alkoxides with deionized water and peptization of the resulting hydrolysate with diluted acid nitric at 100 C. The addition of Nb stabilizes the anatase phase to higher temperatures. XRD spectra of the undoped and the Nb-doped samples show that the undoped sample has been almost totally converted to rutile at 600 C, meanwhile the doped samples present still a low percentage of rutile phase. Nanocrystalline powders stabilized at 600 C with grain sizes of about 17 nm have successfully been synthesized by the addition of Nb with a concentration of 2% at., which appears to be an adequate additive concentration to improve the gas sensor performances, such as it is suggested by the catalytic conversion efficiency experiments performed from FTIR measurements. FTIR absorbance spectra show that catalytic conversion of CO occurs at lower temperatures when niobium is introduced. The electrical response of the films to different concentrations of CO and ethanol has been monitored in dry and wet environments in order to test the influence of humidity in the sensor response. The addition of Nb decreases the working temperature and increases the stability of the layers. Also, large enhancement of the response time is obtained even with lower working temperatures. Moreover, humidity effects on the gas sensor response toward CO and ethanol are less important in Nb-doped samples than in the undoped ones.
Resumo:
High-resolution side scan sonar has been used for mapping the seafloor of the Ría de Pontevedra. Four backscatter patterns have been mapped within the Ría: (1) Pattern with isolated reflections, correlated with granite and metamorphic outcrops and located close to the coastal prominence and Ons and Onza Islands. (2) Pattern of strong reflectivity usually located around the basement outcrops and near the coastline and produced by coarse-grained sediment. (3) Pattern of weak backscatter is correlated with fine sand to mud and comprising large areas in the central and deep part of the Ría, where the bottom currents are weak. It is generally featureless, except where pockmarks and anthropogenic features are present. (4) Patches of strong and weak backscatter are located in the boundary between coarse and fine-grained sediments and they are due to the effect of strong bottom currents. The presence of megaripples associated to both patterns of strong reflectivity and sedimentary patches indicate bedload transport of sediment during high energy conditions (storms). Side scan sonar records and supplementary bathymetry, bottom samples and hydrodynamic data reveal that the distribution of seafloor sediment is strongly related to oceanographic processes and the particular morphology and topography of the Ría.
Resumo:
Calculations of the binding energy of bound positron states in metal surfaces, with explicit inclusion of plasmon dispersion and single-particle effects, are presented. The binding energy is greatly reduced with respect to the undispersed case.
Resumo:
A surface dielectric function of a semi-infinite plane-bounded metal is defined in the spirit of the plasmon-pole dielectric function of the bulk. It is modeled in such a way that the surface-plasmon dispersion relation is recovered for small momentum transfer. This function is employed to compute the image potential at all distances outside the surface. Interaction with bulk modes is neglected for simplicity and clarity. The interaction of a massive point charge with a metal surface is also considered in the context of a boson model for surface-plasmon excitation. We present a new definition of the image potential for this case.