858 resultados para Green chromatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liquid-chromatography (LC) high-resolution (HR) mass spectrometry (MS) analysis can record HR full scans, a technique of detection that shows comparable selectivity and sensitivity to ion transitions (SRM) performed with triple-quadrupole (TQ)-MS but that allows de facto determination of "all" ions including drug metabolites. This could be of potential utility in in vivo drug metabolism and pharmacovigilance studies in order to have a more comprehensive insight in drug biotransformation profile differences in patients. This simultaneous quantitative and qualitative (Quan/Qual) approach has been tested with 20 patients chronically treated with tamoxifen (TAM). The absolute quantification of TAM and three metabolites in plasma was realized using HR- and TQ-MS and compared. The same LC-HR-MS analysis allowed the identification and relative quantification of 37 additional TAM metabolites. A number of new metabolites were detected in patients' plasma including metabolites identified as didemethyl-trihydroxy-TAM-glucoside and didemethyl-tetrahydroxy-TAM-glucoside conjugates corresponding to TAM with six and seven biotransformation steps, respectively. Multivariate analysis allowed relevant patterns of metabolites and ratios to be associated with TAM administration and CYP2D6 genotype. Two hydroxylated metabolites, α-OH-TAM and 4'-OH-TAM, were newly identified as putative CYP2D6 substrates. The relative quantification was precise (<20 %), and the semiquantitative estimation suggests that metabolite levels are non-negligible. Metabolites could play an important role in drug toxicity, but their impact on drug-related side effects has been partially neglected due to the tremendous effort needed with previous MS technologies. Using present HR-MS, this situation should evolve with the straightforward determination of drug metabolites, enlarging the possibilities in studying inter- and intra-patients drug metabolism variability and related effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the fact that aluminum toxicity to crops is eliminated near soil water pH of 5.5, lime recommendation in many regions aims to increase soil pH up to 6.0 or even higher. For highly buffered soils, high rates of limestone are required to raise the pH from 5.5 to 6.0, resulting in additional, sometimes unnecessary, costs. The objective of this study was to evaluate the effect of soil pH on corn yield in a very acid Hapludox. The experiment was carried out in Lages, Southern Brazil, from 1992 to 1996. The soil had water pH of 4.7, Al3+ of 33 mmol c kg-1, O.M. of 45 g kg-1 and lime requirement to pH 6.0 of 9.0 t ha-1. Dolomitic limestone at rates of 0, 4.5, 9.0, 13.5 and 18.0 t ha-1 (equivalent to pure CaCO3) was incorporated into the soil down to 17 cm depth, in 1992. Liming increased linearly the values of soil pH (from 4.7 to 6.6) and Ca and Mg, eliminated Al3+ with rates of 9.0 t ha-1 or higher, decreased slightly Al-CuCl2, Fe and Cu, and did not affect Zn and Mn. Maximum average corn yield for grain (7.9 t ha-1) and for green matter for silage (GM) (59 t ha-1) was obtained, respectively, at soil pH of 6.0 (12 t ha-1 of limestone) and of 6.1 (14 t ha-1 of limestone); maximum economic efficiency for grain was obtained at pH 5.6 (7.5 t ha-1 of limestone). Maximum yield increments due to liming were 17% for grain and 20% for GM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two concentration methods for fast and routine determination of caffeine (using HPLC-UV detection) in surface, and wastewater are evaluated. Both methods are based on solid-phase extraction (SPE) concentration with octadecyl silica sorbents. A common “offline” SPE procedure shows that quantitative recovery of caffeine is obtained with 2 mL of an elution mixture solvent methanol-water containing at least 60% methanol. The method detection limit is 0.1 μg L−1 when percolating 1 L samples through the cartridge. The development of an “online” SPE method based on a mini-SPE column, containing 100 mg of the same sorbent, directly connected to the HPLC system allows the method detection limit to be decreased to 10 ng L−1 with a sample volume of 100 mL. The “offline” SPE method is applied to the analysis of caffeine in wastewater samples, whereas the “on-line” method is used for analysis in natural waters from streams receiving significant water intakes from local wastewater treatment plants

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Fluorescein (FA) and indocyanine-green angiography (ICGA) may offer valuable information concerning disease severity and prognosis in ocular syphilis. The aim of the present study is to describe angiographic patterns encountered in the context of ocular syphilis, and to explore the associations between specific angiographic manifestations and severity of disease presentation, as well as disease evolution after treatment. METHODS: We performed a retrospective institutional study with the inclusion of 23 patients with ocular syphilis presenting to the uveitis clinic of the Jules-Gonin Eye Hospital in a 10-year period. FA and ICGA were performed following a standard protocol for posterior uveitis. Patterns of fluorescence were noted, and statistical associations between each angiographic pattern and any demographic, clinical, or laboratory parameter at baseline and after treatment were sought. RESULTS: The presence of any dark dots in ICGA was significantly associated with anterior uveitis (p = 0.031). The presence of hot spots in ICGA was significantly associated with longer duration of symptoms prior to initial visit (p = 0.032) and with male gender (p = 0.012). Weak non-significant trends were found associating vascular staining in FA with anterior uveitis (p = 0.066), vitritis (p = 0.069), and younger age (p = 0.061), as well as disc hyperfluorescence in FA with seropositivity for HIV (p = 0.089) and macular edema in FA with longer disease duration (p = 0.061). The presence of any dark dots in ICGA exhibited a weak trend of association with anterior uveitis and/or vitritis (p = 0.079). CONCLUSIONS: Out of the several associations identified implicating specific angiographic features, we underline the possible role of the presence of dark dots in ICGA for identifying active inflammation, and the role of hot spots in ICGA as markers of long-standing disease. Vascular staining in FA appears to be more common in patients with severe ocular inflammation with presence of anterior uveitis and/or vitritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The urinary steroid profile is constituted by anabolic androgenic steroids, including testosterone and its relatives, that are extensively metabolized into phase II sulfated or glucuronidated steroids. The use of liquid chromatography coupled to mass spectrometry (LC-MS) is an issue for the direct analysis of conjugated steroids, which can be used as urinary markers of exogenous steroid administration in doping analysis, without hydrolysis of the conjugated moiety. In this study, a sensitive and selective ultra high-pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometer (UHPLC-QTOF-MS) method was developed to quantify major urinary metabolites simultaneously after testosterone intake. The sample preparation of the urine (1 mL) was performed by solid-phase extraction on Oasis HLB sorbent using a 96-well plate format. The conjugated steroids were analyzed by UHPLC-QTOF-MS(E) with a single-gradient elution of 36 min (including re-equilibration time) in the negative electrospray ionization mode. MS(E) analysis involved parallel alternating acquisitions of both low- and high-collision energy functions. The method was validated and applied to samples collected from a clinical study performed with a group of healthy human volunteers who had taken testosterone, which were compared with samples from a placebo group. Quantitative results were also compared to GC-MS and LC-MS/MS measurements, and the correlations between data were found appropriate. The acquisition of full mass spectra over the entire mass range with QTOF mass analyzers gives promise of the opportunity to extend the steroid profile to a higher number of conjugated steroids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensitive and specific methods based on gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) for the determination of levels of citalopram, desmethylcitalopram and didesmethylcitalopram in the plasma of patients treated with citalopram are presented, as well as a GC-MS procedure for the assay of the citalopram propionic acid derivative. After addition of a separate internal standard for each drug, liquid-solvent extraction is used to separate the basic compounds from the acid compounds. The demethylated amines are derivatized with trifluoroacetic anhydride, and the acid metabolite with methyl iodide. GC-MS is performed in the electron impact mode, as mass spectrometry by the (positive-ion) chemical ionization mode (methane and ammonia) appeared to be unsuitable. The limits of quantification were 1 ng/ml for citalopram and desmethylcitalopram and 2 ng/ml for the other metabolites. The correlation coefficients for the calibration curves (range 10-500 ng/ml) were &gt; or = 0.999 for all compounds, whether determined by GC or GC-MS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A team representing Iowa Workforce Development, the Office of Energy Independence, the Department of Natural Resources, the Department of Public Safety, the Iowa Utilities Board, the Department of Economic Development and Iowa Community Colleges reviewed many reports on green jobs published by states, associations and private research companies with the purpose of determining whether the number of “green collar” jobs in Iowa’s economy can be quantified. The team found that there was no standard on definition, identifying jobs or occupations, or level of inclusion for counting green collar jobs. All reports were tailored to their own audiences, without regard to the ability to measure their results against findings made by other states or organizations. Green collar jobs can be found in construction, manufacturing, installation, maintenance, agriculture and many other sectors of the economy. While some of the green collar jobs are in new occupations and industries, most are existing jobs that demand new green collar skills.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the role of Indocyanin Green (ICG) angiography in localizing occult new vessels associated with age-related macular degeneration (ARMD) and assess the possibilities of ICG guided laser photocoagulations. PATIENTS AND METHODS: Fluorescein and ICG angiographies (IMAGEnet system) of 62 patients with occult new vessels (ONV), serous (SPED) or vascular (VPED) pigment epithelium detachment have been studied. RESULTS: Based on fondoscopic examination and fluorescein angiography, 43 eyes (69%) disclosed ONV, 8 (13%) SPED and 11 (18%) VPED. Choroidal neovascularisation was confirmed by ICG angiography in 37 ONV cases (86%), in 8 (72%) VPED cases, but in no SPED. Conversion of ONV in classical neovascular membranes was possible in 19 ONV cases (44%) and in 6 (54%) VPED cases, making a laser photocoagulation possible in 9 eyes (36%). CONCLUSION: ICG angiography plays an important role in the evaluation, classification and laser treatment of patients with ONV secondary to ARMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our study was to present a new headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable to the routine determination of hydrogen sulfide (H(2)S) concentrations in biological and gaseous samples. The primary analytical drawback of the GC/MS methods for H(2)S measurement discussed in the literature was the absence of a specific H(2)S internal standard required to perform quantification. Although a deuterated hydrogen sulfide (D(2)S) standard is currently available, this standard is not often used because this standard is expensive and is only available in the gas phase. As an alternative approach, D(2)S can be generated in situ by reacting deuterated chloride with sodium sulfide; however, this technique can lead to low recovery yield and potential isotopic fractionation. Therefore, N(2)O was chosen for use as an internal standard. This method allows precise measurements of H(2)S concentrations in biological and gaseous samples. Therefore, a full validation using accuracy profile based on the β-expectation tolerance interval is presented. Finally, this method was applied to quantify H(2)S in an actual case of H(2)S fatal intoxication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New directly acting antivirals (DAAs) that inhibit hepatitis C virus (HCV) replication are increasingly used for the treatment of chronic hepatitis C. A marked pharmacokinetic variability and a high potential for drug-drug interactions between DAAs and numerous drug classes have been identified. In addition, ribavirin (RBV), commonly associated with hemolytic anemia, often requires dose adjustment, advocating for therapeutic drug monitoring (TDM) in patients under combined antiviral therapy. However, an assay for the simultaneous analysis of RBV and DAAs constitutes an analytical challenge because of the large differences in polarity among these drugs, ranging from hydrophilic (RBV) to highly lipophilic (telaprevir [TVR]). Moreover, TVR is characterized by erratic behavior on standard octadecyl-based reversed-phase column chromatography and must be separated from VRT-127394, its inactive C-21 epimer metabolite. We have developed a convenient assay employing simple plasma protein precipitation, followed by high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) for the simultaneous determination of levels of RBV, boceprevir, and TVR, as well as its metabolite VRT-127394, in plasma. This new, simple, rapid, and robust HPLC-MS/MS assay offers an efficient method of real-time TDM aimed at maximizing efficacy while minimizing the toxicity of antiviral therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Audit report on the Disaster Grants – Public Assistance program of the Green Bay Levee and Drainage District in Lee County, Iowa for the year ended June 30, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to investigate the efficiency of sulfate green rust (GR2) to remove Ni from solution, GR2 samples were synthesized under controlled laboratory conditions. Some GR2 samples were synthesized from Fe(II) and Fe(III) sulfate salts by precipitation. Other samples were prepared by coprecipitation, of Ni(II), Fe(II) and Fe(III) sulfate salts, i.e., in the presence of Ni. In another sample, Ni(II) sulfate salt was added to pre-formed GR2. After an initial X-ray diffraction (XRD) characterization all samples were exposed to ambient air in order to understand the role of Ni in the transformation of the GR2 samples. XRD was repeated after 45 days. The results showed that Nious GR2 prepared by coprecipitation is isomorphous to Ni-free GR2, i.e. Ni is incorporated into the crystalline structure. Fe(II) was not replaced by Ni(II) in the crystalline structure of GR2 formed prior to exposure to solution-phase Ni. This suggests Ni was adsorbed to the GR2 surface. Sulfate green rust is more efficient in removing Ni from the environment by coprecipitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A partir de uma análise detalhada do processo de infiltração de água no solo, foram propostas alternativas para adequação dos parâmetros de entrada do modelo de Green-Ampt-Mein-Larson (GAML), na tentativa de melhorar a eficiência da estimativa da infiltração em alguns solos brasileiros. As adequações consistiram em substituir a condutividade hidráulica do solo saturado (K0) pela taxa de infiltração estável (Tie) e o teor de água do solo saturado (q s) pelo teor de água na zona de transmissão (q w), além de estabelecer uma equação para estimativa do potencial matricial na frente de umedecimento (y f) com base nos parâmetros do modelo de curva de retenção de água de Brooks & Corey. Avaliou-se o desempenho do conjunto de adequações propostas (GAML-t) para estimativa da infiltração de água em três solos: Latossolo Vermelho-Amarelo, Latossolo Vermelho e Argissolo Vermelho. O desempenho do GAML-t foi comparado com o obtido pelo GAML aplicado em sua forma original e adequado segundo cinco diferentes formas, evidenciando-se que o primeiro obteve melhor desempenho nos três solos estudados.