956 resultados para Gas Sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ripglut1;glut2-/- mice have no endogenous glucose transporter type 2 (glut2) gene expression but rescue glucose-regulated insulin secretion. Control of glucagon plasma levels is, however, abnormal, with fed hyperglucagonemia and insensitivity to physiological hypo- or hyperglycemia, indicating that GLUT2-dependent sensors control glucagon secretion. Here, we evaluated whether these sensors were located centrally and whether GLUT2 was expressed in glial cells or in neurons. We showed that ripglut1;glut2-/- mice failed to increase plasma glucagon levels following glucoprivation induced either by i.p. or intracerebroventricular 2-deoxy-D-glucose injections. This was accompanied by failure of 2-deoxy-D-glucose injections to activate c-Fos-like immunoreactivity in the nucleus of the tractus solitarius and the dorsal motor nucleus of the vagus. When glut2 was expressed by transgenesis in glial cells but not in neurons of ripglut1;glut2-/- mice, stimulated glucagon secretion was restored as was c-Fos-like immunoreactive labeling in the brainstem. When ripglut1;glut2-/- mice were backcrossed into the C57BL/6 genetic background, fed plasma glucagon levels were also elevated due to abnormal autonomic input to the alpha cells; glucagon secretion was, however, stimulated by hypoglycemic stimuli to levels similar to those in control mice. These studies identify the existence of central glucose sensors requiring glut2 expression in glial cells and therefore functional coupling between glial cells and neurons. These sensors may be activated at different glycemic levels depending on the genetic background.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional analysis of the entire sequence in ski jumping is recommended when studying the kinematics or evaluating performance. Camera-based systems which allow three-dimensional kinematics measurement are complex to set-up and require extensive post-processing, usually limiting ski jumping analyses to small numbers of jumps. In this study, a simple method using a wearable inertial sensors-based system is described to measure the orientation of the lower-body segments (sacrum, thighs, shanks) and skis during the entire jump sequence. This new method combines the fusion of inertial signals and biomechanical constraints of ski jumping. Its performance was evaluated in terms of validity and sensitivity to different performances based on 22 athletes monitored during daily training. The validity of the method was assessed by comparing the inclination of the ski and the slope at landing point and reported an error of -0.2±4.8°. The validity was also assessed by comparison of characteristic angles obtained with the proposed system and reference values in the literature; the differences were smaller than 6° for 75% of the angles and smaller than 15° for 90% of the angles. The sensitivity to different performances was evaluated by comparing the angles between two groups of athletes with different jump lengths and by assessing the association between angles and jump lengths. The differences of technique observed between athletes and the associations with jumps length agreed with the literature. In conclusion, these results suggest that this system is a promising tool for a generalization of three-dimensional kinematics analysis in ski jumping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amb el present projecte es proposa fer un estudi de la web semàntica aplicada a la descripció i modelització de la instrumentació marina operada en el context de campanyes d'investigació oceanogràfica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tripping is considered a major cause of fall in older people. Therefore, foot clearance (i.e., height of the foot above ground during swing phase) could be a key factor to better understand the complex relationship between gait and falls. This paper presents a new method to estimate clearance using a foot-worn and wireless inertial sensor system. The method relies on the computation of foot orientation and trajectory from sensors signal data fusion, combined with the temporal detection of toe-off and heel-strike events. Based on a kinematic model that automatically estimates sensor position relative to the foot, heel and toe trajectories are estimated. 2-D and 3-D models are presented with different solving approaches, and validated against an optical motion capture system on 12 healthy adults performing short walking trials at self-selected, slow, and fast speed. Parameters corresponding to local minimum and maximum of heel and toe clearance were extracted and showed accuracy ± precision of 4.1 ± 2.3 cm for maximal heel clearance and 1.3 ± 0.9 cm for minimal toe clearance compared to the reference. The system is lightweight, wireless, easy to wear and to use, and provide a new and useful tool for routine clinical assessment of gait outside a dedicated laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our study was to present a new headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable to the routine determination of hydrogen sulfide (H(2)S) concentrations in biological and gaseous samples. The primary analytical drawback of the GC/MS methods for H(2)S measurement discussed in the literature was the absence of a specific H(2)S internal standard required to perform quantification. Although a deuterated hydrogen sulfide (D(2)S) standard is currently available, this standard is not often used because this standard is expensive and is only available in the gas phase. As an alternative approach, D(2)S can be generated in situ by reacting deuterated chloride with sodium sulfide; however, this technique can lead to low recovery yield and potential isotopic fractionation. Therefore, N(2)O was chosen for use as an internal standard. This method allows precise measurements of H(2)S concentrations in biological and gaseous samples. Therefore, a full validation using accuracy profile based on the β-expectation tolerance interval is presented. Finally, this method was applied to quantify H(2)S in an actual case of H(2)S fatal intoxication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

GLUT2-/- mice reexpressing GLUT1 or GLUT2 in their beta-cells (RIPGLUT1 x GLUT2-/- or RIPGLUT2 x GLUT2-/- mice) have nearly normal glucose-stimulated insulin secretion but show high glucagonemia in the fed state. Because this suggested impaired control of glucagon secretion, we set out to directly evaluate the control of glucagonemia by variations in blood glucose concentrations. Using fasted RIPGLUT1 x GLUT2-/- mice, we showed that glucagonemia was no longer increased by hypoglycemic (2.5 mmol/l glucose) clamps or suppressed by hyperglycemic (10 and 20 mmol/l glucose) clamps. However, an increase in plasma glucagon levels was detected when glycemia was decreased to < or =1 mmol/l, indicating preserved glucagon secretory ability, but of reduced sensitivity to glucopenia. To evaluate whether the high-fed glucagonemia could be due to an abnormally increased tone of the autonomic nervous system, fed mutant mice were injected with the ganglionic blockers hexamethonium and chlorisondamine. Both drugs lead to a rapid return of glucagonemia to the levels found in control fed mice. We conclude that 1) in the absence of GLUT2, there is an impaired control of glucagon secretion by low or high glucose; 2) this impaired glucagon secretory activity cannot be due to absence of GLUT2 from alpha-cells because these cells do not normally express this transporter; 3) this dysregulation may be due to inactivation of GLUT2-dependent glucose sensors located outside the endocrine pancreas and controlling glucagon secretion; and 4) because fed hyperglucagonemia is rapidly reversed by ganglionic blockers, this suggests that in the absence of GLUT2, there is an increased activity of the autonomic nervous system stimulating glucagon secretion during the fed state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment of locomotion through simple tests such as timed up and go (TUG) or walking trials can provide valuable information for the evaluation of treatment and the early diagnosis of people with Parkinson's disease (PD). Common methods used in clinics are either based on complex motion laboratory settings or simple timing outcomes using stop watches. The goal of this paper is to present an innovative technology based on wearable sensors on-shoe and processing algorithm, which provides outcome measures characterizing PD motor symptoms during TUG and gait tests. Our results on ten PD patients and ten age-matched elderly subjects indicate an accuracy ± precision of 2.8 ± 2.4 cm/s and 1.3 ± 3.0 cm for stride velocity and stride length estimation compared to optical motion capture, with the advantage of being practical to use in home or clinics without any discomfort for the subject. In addition, the use of novel spatio-temporal parameters, including turning, swing width, path length, and their intercycle variability, was also validated and showed interesting tendencies for discriminating patients in ON and OFF states and control subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Variable definitions of outcome (Constant score, Simple Shoulder Test [SST]) have been used to assess outcome after shoulder treatment, although none has been accepted as the universal standard. Physicians lack an objective method to reliably assess the activity of their patients in dynamic conditions. Our purpose was to clinically validate the shoulder kinematic scores given by a portable movement analysis device, using the activities of daily living described in the SST as a reference. The secondary objective was to determine whether this device could be used to document the effectiveness of shoulder treatments (for glenohumeral osteoarthritis and rotator cuff disease) and detect early failures.Methods: A clinical trial including 34 patients and a control group of 31 subjects over an observation period of 1 year was set up. Evaluations were made at baseline and 3, 6, and 12 months after surgery by 2 independent observers. Miniature sensors (3-dimensional gyroscopes and accelerometers) allowed kinematic scores to be computed. They were compared with the regular outcome scores: SST; Disabilities of the Arm, Shoulder and Hand; American Shoulder and Elbow Surgeons; and Constant.Results: Good to excellent correlations (0.61-0.80) were found between kinematics and clinical scores. Significant differences were found at each follow-up in comparison with the baseline status for all the kinematic scores (P < .015). The kinematic scores were able to point out abnormal patient outcomes at the first postoperative follow-up.Conclusion: Kinematic scores add information to the regular outcome tools. They offer an effective way to measure the functional performance of patients with shoulder pathology and have the potential to detect early treatment failures.Level of evidence: Level II, Development of Diagnostic Criteria, Diagnostic Study. (C) 2011 Journal of Shoulder and Elbow Surgery Board of Trustees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quenching of the photoluminescence of Si nanopowder grown by plasma-enhanced chemical vapor deposition due to pressure was measured for various gases ( H2, O2, N2, He, Ne, Ar, and Kr) and at different temperatures. The characteristic pressure, P0, of the general dependence I(P) = I0¿exp(¿P/P0) is gas and temperature dependent. However, when the number of gas collisions is taken as the variable instead of pressure, then the quenching is the same within a gas family (mono- or diatomic) and it is temperature independent. So it is concluded that the effect depends on the number of gas collisions irrespective of the nature of the gas or its temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel NO2 sensor based on (CdO)x(ZnO)1-x mixed-oxide thin films deposited by the spray pyrolysis technique is developed. The sensor response to 3-ppm NO2 is studied in the range 50°C-350°C for three different film compositions. The device is also tested for other harmful gases, such as CO (300 ppm) and CH4 (3000 ppm). The sensor response to these reducing gases is different at different temperatures varying from the response typical for the p-type semiconductor to that typical for the n-type semiconductor. Satisfactory response to NO2 and dynamic behavior at 230°C, as well as low resistivity, are observed for the mixed-oxide film with 30% Cd. The response to interfering gas is poor at working temperature (230°C). On the basis of this study, a possible sensing mechanism is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ammonia gas detection by pure and catalytically modified WO3 based gas sensor was analysed. The sensor response of pure WO3 to NH3 was not only rather low but also presented an abnormal behaviour, probably due to the unselective oxidation of ammonia to NOx. Copper and vanadium were introduced in different concentrations and the resulting material was annealed at different temperatures in order to improve the sensing properties for NH3 detection. The introduction of copper and vanadium as catalytic additives improved the response to NH3 and also eliminated the abnormal behaviour. Possible mechanisms of NH3 reaction over these materials are discussed. Sensor responses to other gases like NO2 or CO and the interference of humidity on ammonia detection were also analysed so as to choose the best sensing element.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[cat] En els últims temps es parla molt del nou paper dels hidrocarburs d'Àfrica, fins i tot s'al·ludeix a un oil rush o a un african oil scramble , que inevitablement desembocarà en una confrontació bipolar entre la Xina i els Estats Units, pel control de les reserves de petroli del subsòl del continent africà. Així, el propòsit d'aquest text és, en primer lloc, realitzar una anàlisi descriptiva que ajudi a valorar la hipòtesi d'aquest african oil scramble. A continuación, amb les dades obtingudes, es discutirà sobre la possibilitat de que aquest fenomen desemboqui en un escenari de confrontació xinoamericana. Aquesta especulació ens durà a concloure que hi ha suficients indicis per a argumentar que el joc petrolífer africà podria desenvolupar-se en un escenari marcat per la multilateralitat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

More than half of invasive bacterial infections are Gram-positive in origin. This class of bacteria has neither endotoxins nor an outer membrane, yet it generates some of the most powerful inflammatory responses known in medicine. Some recent seminal studies go a long way toward settling the controversies that surround the process by which Gram-positive bacterial surfaces trigger the human immune system. Although the components of the cell wall are now chemically defined in exquisite detail and the interaction with the toll-like receptor 2 pathway has been discovered, it is only very recently that definitive studies combining these advanced biochemical and cell biological tools have been carried out. It is these breakthrough studies that have finally confirmed the paradigm of innate sensors for Gram-positive bacteria.