818 resultados para Fiber Optic Sensors in Quality evaluation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluoride toothpastes are a risk factor for the development of dental fluorosis. Products with low fluoride content offer a higher security, but their effectiveness must be proven. The aim of this in vitro study was to compare two acidified toothpastes with low fluoride concentration (412 and 550 mu g F/g) with neutral toothpastes. Bovine enamel blocks were selected by surface microhardness (SMH) and randomized to twelve groups of 13, according to the fluoride concentration in toothpaste (placebo, 275, 412, 550 or 1,100 jig F/g) and pH (7.0 or 5.5). Two commercially available toothpastes were also studied: a 1,100-mu g F/g, pH 7.0 paste (positive control) and a children's paste (500 mu g F/g, pH 7.0). The blocks were subjected to pH cycling for 7 days. The toothpaste treatment was done twice daily. Surface and cross-sectional microhardnesses were assessed to calculate the percentage change of SMH (%SMH) and the mineral loss (Delta Z). The amount of fluoride, calcium and phosphorus in the solutions after the pH cycling was also analyzed. Compared to neutral toothpastes, the acidified toothpastes reduced the %SMH in all F concentrations. Higher F and lower Ca and P concentrations were found in solutions for the acidified toothpastes. Regarding AZ, only the positive control, 1,100-mu g F/g (acidified and neutral) groups were not statistically different. The acidified toothpastes showed a dose-response relationship with all variables. For the low-fluoride toothpastes evaluated, only the 550-mu g F/g acidified paste had the same anticariogenic action as the 1,100-mu g F/g neutral paste.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the biomechanical preparation of flattened root canals using the following systems: Endo-Eze AET stainless steel oscillatory instruments (Ultradent) and RaCe rotary NiTi instruments (FKG Dentaire). Materials and Methods: Twenty extracted human mandibular incisors were randomly assigned to two groups: Group I Instrumentation with oscillatory Endo-Eze AET files (oscillatory technique); Group 2 - Instrumentation with rotary NiTi RaCe files (rotary technique). The teeth were decoronated, had their apices and coronal openings sealed with sticky wax and were embedded in crystal-clear orthophtalic polyester resin. The roots were sectioned transversally with diamond discs at 10 mm (middle third) and 5 mm (apical third) from the apex and the segments were reassembled for instrumentation. The sections were photographed before and after root canal instrumentation and evaluated with respect to whether the original root canal shape was modified by instrumentation. To evaluate the differences in the root canal shape before and after biomechanical preparation, scores were given regarding the instruments touch on the intracanal walls. Results: In middle third of the root canals instrumented with the rotary system, there was a change in the original canal anatomy (p < 0.05), with formation of a protuberance in the mesiodistal direction. This protuberance did not occur when the oscillatory instrumentation was used. The oscillatory system had better results in the middle and apical thirds as evaluated by Dunn's multiple-comparison test (p > 0.05). Conclusion: Under the tested conditions, Endo-Eze oscillatory system yielded the instrumentation of all flattened oot canal walls, maintaining the canal original shape throughout the biomechanical preparation, and was more effective than RaCe rotary system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fiber types distribution in the diagastric muscle of tufted capuchin monkey was studied by means of NADH-TR, myosin-ATPase, after alkaline and acid preincubations and SDH histochemical reactions. Three different types of fibers were found presenting an equal distribution. The percentage and types of fibers were as follow: 18.2 % SO (Slow Oxydative), 38.4 % FOG (Fast Oxydative Glycolytic) and 43.4 % FG (Fast Glycolytic). FG fibers revealed the largest area. The relatively high concentration of fast twitch (81.2 %) seems to indicate this muscle is involved with the acceleration and fast speed of jaw movements. Aerobic metabolism represented by SO + FOG fibers (56.6 %) suggests that this muscle possesses an additional role than that related to the lowering of the jaw.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of problem. Prosthetic restorations that fit poorly may affect periodontal health and occlusion. Studies that have evaluated the accuracy of fit of ceramic restorations before and after cementation assessed primarily intracoronal restorations.Purpose. This in vitro study evaluated the effect of different finish lines, ceramic manufacturing techniques, and luting agents on the vertical discrepancy of ceramic copings.Material and methods. Two stainless steel molars were prepared for complete crowns with 2 different finish lines (heavy chamfer and rounded shoulder); each molar was duplicated to fabricate 90 copings. A total of 180 copings generated 18 groups (n=10 for each finish line-coping material-luting agent combination). Luting agents tested included zinc phosphate, resin-modified glass ionomer (Fuji Plus), and resin composite cements (Panavia F). A metal frame was developed on which to screw the stainless steel model and a ceramic coping; the distance (mum) between 2 predetermined points was measured before and after cementation by a profile projector under a torquing force. A 4-way ANOVA with repeated measurements was performed to assess the influence of each factor in the vertical marginal discrepancy: 3 between-coping factors (finish line-coping material-luting agent) and 1 within-coping factor (before and after cementation) (alpha=.05).Results. Procera copings presented the lowest mean values (P<.05) of vertical marginal discrepancy before and after cementation (25/44 mum) when compared to Empress 2 (68/110 mum) and InCeram Alumina copings (57/117 mum), regardless of any combinations among all finish lines and luting agents tested.Conclusion. Considering each factor separately, the ceramic manufacturing technique appeared to be the most important factor tested for the definitive vertical discrepancy of all-ceramic copings, with lower mean values for Procera copings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the effectiveness of acidic low-fluoride dentifrices compared to conventional neutral dentifrices. Enamel blocks were submitted to pH cycling and treatment with slurries of dentifrices containing 0, 275, 412, 550 and 1,100 mu g F/g (pH 4.5 or 7.0), and also a commercial dentifrice (1,100 mu g F/g) and a commercial children's dentifrice (500 mu g F/ g). Variations in surface microhardness and in the mineral content in enamel after pH cycling were calculated. Enamel blocks treated with acidic dentifrices exhibited less mineral loss compared to neutral dentifrices (ANOVA; p < 0.05). The acidic dentifrices with 412 and 550 mu g F/g had the same effectiveness as the neutral 1,100-mu g F/g dentifrice and commercial 1,100-mu g F/g dentifrice. Copyright (c) 2007 S. Karger AG, Basel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This in vitro study evaluated the performance of visual (International Caries Detection and Assessment System [ICDAS]) and radiographic (bitewing [BW]) examinations for occlusal caries detection and their associations with treatment decision (TD). Permanent teeth (n=104) with occlusal surfaces varying from sound to cavitated were selected. Sites were identified from 10x occlusal surface photographs. Standardized bitewing (BW) radiographs were taken. Four dentists with at least five years of experience scored all teeth twice (one-week interval) for ICDAS (0-6), BW (0=sound, 1=caries restricted to enamel, 2=caries in outer third dentin, 3=caries in inner third dentin), and TD (0=no treatment, 1=sealant, 2=microabrasion and sealant, 3=round bur sealant, 4a=resin, 4b=amalgam). Histological validation was performed by observation under a light microscope, with lesions classified on a five-point scale. Intraexaminer and inter-examiner repeatability were assessed using two-way tables and intraclass correlation coefficients (ICCs). Comparisons between percentage correct, specificity, sensitivity, and area under the receiver-operating characteristic (ROC) curve were performed using bootstrap analyses. ICCs for intraexaminer and interexaminer repeatability indicated good repeatability for each examiner, ranging from 0.78 to 0.88, and among examiners, ranging from 0.74 to 0.81. Correlation between ICDAS and TD was 0.85 and between BW and TD was 0.78. Correlation between the methods and histological scores was moderate (0.63 for ICDAS and 0.61 for BW). The area under the ROC curve was significantly greater for ICDAS than for BW (p<0.0001). ICDAS had significantly lower specificity than BW did (p=0.0269, 79% vs 94%); however, sensitivity was much higher for ICDAS than for BW (p<0.0001, 83% vs 44%). Data from this investigation suggested that the visual examination (ICDAS) showed better performance than radiographic examination for occlusal caries detection. The ICDAS was strongly associated with TD. Although the correlation between the ICDAS and BW was lower, it is still valuable in the clinical decision-making process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acid erosion is a superficial loss of enamel caused by chemical processes that do not involve bacteria. Intrinsic and extrinsic factors, such as the presence of acid substances in the oral cavity, may cause a pH reduction, thus potentially increasing acid erosion. The aim of this study was to evaluate the microhardness of bleached and unbleached bovine enamel after immersion in a soda beverage, artificial powder juice and hydrochloric acid. The results obtained for the variables of exposure time, acid solution and substrate condition (bleached or unbleached enamel) were statistically analyzed by the ANOVA and Tukey tests. It was concluded that a decrease in microhardness renders dental structures more susceptible to erosion and mineral loss, and that teeth left unbleached show higher values of microhardness compared to bleached teeth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coccoloba mollis (Family Polygonaceae) is a medicinal plant popularly used in cases of memory loss, stress, insomnia, anemia, impaired vision, and sexual impotence, but the scientific literature, to date, lacks studies on the biological effects of this species, particularly with regard to cytotoxicity and induction of DNA damage. The aim of the present study was to assess in vitro (in hepatic HTC cells) ethanolic extracts of the roots and leaves of C. mollis for cytotoxicity, genotoxicity, and induction of apoptosis. For these evaluations the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) cytotoxicity assay, comet assay, micronucleus test with cytokinesis block, and an in situ test for detection of apoptotic cells with acridine orange staining were used. The results showed that the extract obtained from the roots of C. mollis is more cytotoxic than that obtained from the leaves and that the reduction in cell viability observed in the MTT assay was a result, at least in part, from the induction of apoptosis. Both extracts induced DNA damage at a concentration of 20 mu g/mL in the comet assay, but no genotoxicity was detected with any of the treatments carried out in the micronucleus test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An ambiguity in the computation of the one-loop effective action for fields living on a cone is illustrated. It is shown that the ambiguity arises due to the noncommutativity of the regularization of ultraviolet and (conical) boundary divergencies. ©1999 The American Physical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The antimicrobial activity of four root canal sealers (AH Plus, Sealapex, Ketac Endo, and Fill Canal), two calcium hydroxide pastes (Calen and Calasept), and a zinc oxide paste was evaluated. Seven bacterial strains were used, six of them standard; Micrococcus luteus ATCC 9341, Staphylococcus aureus ATCC 25923, Pseudomonas aeruginosa ATCC 27853, Staphylococcus epidermidis ATCC 12228, Escherichia coli ATCC 25922, and Enterococcus faecalis ATCC 10541. There was a wild strain of Streptococcus mutans isolated from saliva obtained in an adult dental clinic. Activity was evaluated using the agar diffusion method with Brain Heart Infusion agar and Müller Hinton medium seeded by pour plate. Calcium hydroxide-based sealers and pastes were either placed directly into 4.0 × 4.0 mm wells or by using absorbent paper points. The plates were kept at room temperature for 2 hr for diffusion. After incubation at 37°C for 24 hr, the medium was optimized with 0.05 g% TTC gel and inhibition haloes were measured. All bacterial strains were inhibited by all materials using the well method. However, when the materials were applied with absorbent paper points, Enterococcus faecalis was not inhibited by zinc oxide, and Pseudomonas aeruginosa was not inhibited by AH Plus, Fill Canal, and the zinc oxide-based paste. We conclude that sealers and pastes presented antimicrobial activity in vitro and culture medium optimization with 0.05 g% TTC gel facilitated observation of the inhibition haloes. Copyright © 2000 by The American Association of Endodontists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The antimicrobial activity of irrigating solutions - Endoquil (castor oil detergent), 2% chlorhexidine gluconate solution, and 0.5% NaOCI solution - was evaluated against Gram-positive cocci (Micrococcus luteus, Staphylococcus aureus, Enterococcus faecalis, Staphylococcus epidermidis, Streptococcus mutans, and Streptococcus sobrinus), Gramnegative rods (Escherichia coli and Pseudomonas aeruginosa), and the yeast Candida albicans. Activity was evaluated using the two-layer agar diffusion technique. The base layer was obtained by pouring 10.0 ml of Muller Hinton Medium or 10.0 ml of Brain Heart Infusion agar in a Petri dish. After solidification a 5.0 ml seed layer of Muller Hinton Medium or Brain Heart Infusion agar with inoculum (106/ml) was added. Absorbent paper disks (6.0 mm in diameter) immersed in the solutions were placed at equidistant points. Plates were maintained at room temperature for 2 h for prediffusion of the solutions and incubated at 37°C for 24 h. The candle jar system was used for the Brain Heart Infusion agar plates. All tests were performed in duplicate. After incubation the medium was optimized with 0.05 g% triphenyltetrazolium chlorate gel and inhibition halos were measured. All bacterial strains were inhibited by 2.0% chlorhexidine gluconate. Endoquil was effective against Grampositive microorganisms, and 0.5% NaOCI was effective only against S. aureus. Copyright © 2001 by The American Association of Endodontists.