Advances in surgical procedure, prosthesis design, and biomaterials performance have considerably increased the longevity of total joint replacements. Preoperative planning is another step in joint replacement that may have the potential to improve clinical outcome for the individual patient, but has remained relatively consistent for a longtime. One means of advancing this aspect of joint replacement surgery may be to include predictive computer simulation into the planning process. In this article, the potential of patient-specific finite element analysis in preoperative assessment is investigated. Seventeen patient-specific finite element models of cemented Charnley reconstructions were created, of which six were early (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The majority of cemented femoral hip replacements fail as a consequence of loosening. One design feature that may affect loosening rates is implant surface finish. To determine whether or not surface finish effects fatigue damage accumulation in a bone cement mantle, we developed an experimental model of the implanted proximal femur that allows visualisation of damage growth in the cement layer. Five matt surface and five polished surface stems were tested. Pre-load damage and damage after two million cycles was measured. Levels of pre-load (shrinkage) damage were the same for both matt and polished stems; furthermore damage for matt vs. polished stems was not significantly different after two million cycles. This was due to the large variability in damage accumulation rates. Finite element analysis showed that the stress is higher for the polished (assumed debonded) stem, and therefore we must conclude that either the magnitude of the stress increase is not enough to appreciably increase the damage accumulation rate or, alternatively, the polished stem does not debond immediately from the cement. Significantly (P = 0.05) more damage was initiated in the lateral cement compared to the medial cement for both kinds of surface finish. It was concluded that, despite the higher cement stresses with debonded stems, polished prostheses do not provoke the damage accumulation failure scenario. (C) 2003 IPEM. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reliable prediction of long-term medical device performance using computer simulation requires consideration of variability in surgical procedure, as well as patient-specific factors. However, even deterministic simulation of long-term failure processes for such devices is time and resource consuming so that including variability can lead to excessive time to achieve useful predictions. This study investigates the use of an accelerated probabilistic framework for predicting the likely performance envelope of a device and applies it to femoral prosthesis loosening in cemented hip arthroplasty.
A creep and fatigue damage failure model for bone cement, in conjunction with an interfacial fatigue model for the implant–cement interface, was used to simulate loosening of a prosthesis within a cement mantle. A deterministic set of trial simulations was used to account for variability of a set of surgical and patient factors, and a response surface method was used to perform and accelerate a Monte Carlo simulation to achieve an estimate of the likely range of prosthesis loosening. The proposed framework was used to conceptually investigate the influence of prosthesis selection and surgical placement on prosthesis migration.
Results demonstrate that the response surface method is capable of dramatically reducing the time to achieve convergence in mean and variance of predicted response variables. A critical requirement for realistic predictions is the size and quality of the initial training dataset used to generate the response surface and further work is required to determine the recommendations for a minimum number of initial trials. Results of this conceptual application predicted that loosening was sensitive to the implant size and femoral width. Furthermore, different rankings of implant performance were predicted when only individual simulations (e.g. an average condition) were used to rank implants, compared with when stochastic simulations were used. In conclusion, the proposed framework provides a viable approach to predicting realistic ranges of loosening behaviour for orthopaedic implants in reduced timeframes compared with conventional Monte Carlo simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to analyze the role of the pressure head, i.e., the difference of total pressure forces acting on the Indonesian seas waters from the western Pacific and the eastern Indian Ocean, in driving the Indonesian Throughflow (ITF) and in determining the total transport of the ITF. These questions have been discussed in the literature but no consensus has been reached. A regional model of the Indonesian seas circulation has been developed that properly resolves all major topographic features in the region. The results of model runs have been used to calculate all components of the overall momentum balance. The estimates disclose that the dynamical balance is primarily between the volume integrated Coriolis acceleration, pressure gradient and the area integral of local wind stress. It is shown that consideration of components of momentum balance in the direction of the outflow through the Indian Ocean port leads to the formulation of a diagnostic relation between total inflow transports due to the Mindanao and New Guinea Coastal Currents and the external pressure head, internal pressure head, bottom form stress, and area integrated wind stress. Based on this relation, it is concluded that the external pressure head is not the major driving force of the ITF, which is why there is no unique relation between the total transport of the ITF and the external pressure head. However, Wyrtki's suggestion to monitor the variability of the total transport of the ITF by measurement of the sea-surface-height difference between the western Pacific and the eastern Indian Ocean is validated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human Papillomavirus (HPV) related oropharyngeal squamous cell carcinomas (OPSCCs) are reported to have improved prognosis and survival in comparison to other head and neck squamous cell cancers (HNSCCs). This systematic review and meta-analysis examines survival differences in HPV-positive HNSCC and OPSCC subtypes including tonsillar carcinoma in studies not previously investigated. Four electronic databases were searched from their inception till April 2011. A random effects meta-analysis was used to pool study estimates evaluating disease-specific (death from HNSCC), overall (all-cause mortality), progression-free and disease-free (recurrence free) survival outcomes in HPV-positive vs. HPV-negative HNSCCs. All statistical tests were two-sided. Forty-two studies were included. Patients with HPV-positive HNSCC had a 54% better overall survival compared to HPV-negative patients HR 0.46 (95% CI 0.37-0.57); the pooled HR for tonsillar cancer and OPSCC was 0.50 (95% CI 0.33-0.77) and HR 0.47 (95% CI 0.35-0.62) respectively. The pooled HR for disease specific survival was 0.28 (95% CI 0.19-0.40); similar effect sizes were found irrespective of the adjustment for confounders, HPV detection methods or study location. Both progression-free survival and disease-free survival were significantly improved in HPV-positive HNSCCs. HPV-positive HNSCCs and OPSCCs patients have a significantly lower disease specific mortality and are less likely to experience progression or recurrence of their cancer than HPV-negative patients; findings which have connotations for treatment selection in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anther extrusion has been widely discussed as a factor influencing fusarium head blight (FHB) resistance in wheat. This is despite a paucity of quantitative information on its importance, between cultivars, in contrast to that for heading date and plant height. We describe a method applicable to a plant breeding
situation at 10 days postanthesis, for assessing the distinct characteristics of anther retention (anthers held within the spikelet) and trapped anthers (partially
extruded and trapped between the lemma and palea of the wheat spikelet). FHB resistance was tested in field experiments in 2004 and 2005. In these experiments designed to resemble applications to a plant breeding selection scheme anther retention was significantly correlated with FHB in 2004 (r = 0.26; P < 0.05) and 2005 (r = 0.26; P < 0.05). A higher proportion of anthers retained relating, albeit weakly, with increased FHB susceptibility in European wheat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cement-in-cement revision hip arthroplasty is an increasingly popular technique to replace a loose femoral stem which retains much of the original cement mantle. However, some concern exists regarding the retention of the existing fatigued and aged cement in such cement-in-cement revisions. This study investigates whether leaving an existing fatigued and aged cement mantle degrades the mechanical performance of a cement-in-cement revision construct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An adaptation of bungee jumping, 'bungee running', involves participants attempting to run as far as they can whilst connected to an elastic rope which is anchored to a fixed point. Usually considered a safe recreational activity, we report a potentially life-threatening head injury following a bungee running accident.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The authors estimated the retinal nerve fiber layer height (RNFLH) measurements in patients with glaucoma compared with those in age-matched healthy subjects as obtained by the laser scanning tomography and assessed the relationship between RNFLH measurements and optic and visual field status. Methods: Parameters of optic nerve head topography and RNFLH were evaluated in 125 eyes of 21 healthy subjects and 104 patients with glaucoma using the Heidelberg Retina Tomograph ([HRT] Heidelberg Engineering GmbH, Heidelberg, Germany) for the entire disc area and for the superior 70°(50°temporal and 20°nasal to the vertical midline) and inferior 70°sectors of the optic disc. The mean deviation of the visual field, as determined by the Humphrey program 24-2 (Humphrey Instruments, Inc., San Leonardo, CA, U.S.A) was calculated in the entire field and in the superior and inferior Bjerrum area. Result: Retinal nerve fiber layer height parameters (mean RNFLH and RNFL cross-sectional area) were decreased significantly in patients with glaucoma compared with healthy individuals. Retinal nerve fiber layer height parameters was correlated strongly with rim volume, rim area, and cup/disc area ratio. Of the various topography measures, retinal nerve fiber layer (RNFL) parameters and cup/disc area ratio showed the strongest correlation with visual field mean deviation in patients with glaucoma. Conclusion: Retinal nerve fiber layer height measures were reduced substantially in patients with glaucoma compared with age-matched healthy subjects. Retinal nerve fiber layer height was correlated strongly with topographic optic disc parameters and visual field changes in patients with glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Evidence for non-steroidal anti-inflammatory drugs (NSAIDs) preventing head and neck cancer (HNC) is inconclusive; however, there is some suggestion that aspirin may exert a protective effect.

Methods: Using data from the United States National Cancer Institute Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial, we examined the association between aspirin and ibuprofen use and HNC.

Results: Regular aspirin use was associated with a significant 22% reduction in HNC risk. No association was observed with regular ibuprofen use.

Conclusion: Aspirin may have potential as a chemopreventive agent for HNC, but further investigation is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a series of 706 patients (759 hip implants) with an average follow up of 10.5 years (range, 10-11 years) following total hip replacement (THR) using a cemented custom-made femoral stem and a cemented HDP acetabular component. The fate of every implant is known. One hundred and seventy-four patients (23%) were deceased at the time of their 10-year review all died with a functioning THR in situ. Four hundred and sixty-two patients (61%) were subsequently reviewed. One hundred and twenty three patients (16%) were assessed by telephone review, as they were too ill or unwilling to attend. Kaplan-Meier survival analysis (all components) demonstrated a median survival at 10 years of 96.05% or 95% Confidence Intervals (CI) for median survival of (94.41% to 97.22%). Revision surgery occurred in 30 cases (3.9%). Seventeen had full revisions (2.2%) and 13 (1.7%) socket revisions only. Twenty-one out of 30 revisions were for infection or dislocation. There were 2 cases (0.3%) of revision for aseptic loosening of the stem. The 10-year results of the custom femoral titanium stem are encouraging and compare well with other cemented systems.