739 resultados para Eye Lens
Resumo:
Weekly Newsletter from the Northwest District Office for libraries containing programs, activities, classes for the upcoming week.
Resumo:
Weekly Newsletter from the Northwest District Office for libraries containing programs, activities, classes for the upcoming week.
Resumo:
Weekly Newsletter from the Northwest District Office for libraries containing programs, activities, classes for the upcoming week.
Resumo:
Weekly Newsletter from the Northwest District Office for libraries containing programs, activities, classes for the upcoming week.
Resumo:
Weekly Newsletter from the Northwest District Office for libraries containing programs, activities, classes for the upcoming week.
Resumo:
Weekly Newsletter from the Northwest District Office for libraries containing programs, activities, classes for the upcoming week.
Resumo:
Weekly Newsletter from the Northwest District Office for libraries containing programs, activities, classes for the upcoming week.
Resumo:
Peer reviewed
Resumo:
Image filtering is a highly demanded approach of image enhancement in digital imaging systems design. It is widely used in television and camera design technologies to improve the quality of an output image to avoid various problems such as image blurring problem thatgains importance in design of displays of large sizes and design of digital cameras. This thesis proposes a new image filtering method basedon visual characteristics of human eye such as MTF. In contrast to the traditional filtering methods based on human visual characteristics this thesis takes into account the anisotropy of the human eye vision. The proposed method is based on laboratory measurements of the human eye MTF and takes into account degradation of the image by the latter. This method improves an image in the way it will be degraded by human eye MTF to give perception of the original image quality. This thesis gives a basic understanding of an image filtering approach and the concept of MTF and describes an algorithm to perform an image enhancement based on MTF of human eye. Performed experiments have shown quite good results according to human evaluation. Suggestions to improve the algorithm are also given for the future improvements.
Resumo:
PURPOSE: To localize collagen types I, III, and IV, laminin and fibronectin in the anterior human lens capsule. MATERIAL AND METHODS: Twenty-one anterior capsules were sampled by capsulorhexis during extracapsular cataract extraction (mean age 71.5). All capsules were labelled by an immunostaining specific for each antibodies. Immunostaining of four capsules was revealed with immunoperoxydase and seventeen using indirect immunofluorescence. RESULTS: Labelling of collagen types I and III was observed throughout the entire thickness of the capsule for each technique, the strongest labelling was found in the base of the epithelial cells with immunofluorescence. Collagen type IV was observed at the base of the epithelial cells whichever technique was used. Laminin could be detected in the inner layer of the capsule, using immunoperoxydase or immunofluorescence. No specific labelling was found for fibronectin using the two techniques. CONCLUSIONS: Different kinds of collagens have been found in capsules, more particularly the type III. The latter does not appear on other ocular basement membrane. Because of this uneven distribution in the capsule's thickness, each collagen might have a specific function.
Resumo:
Aquest document de treball mira d'establir un nou camp d'investigació a la cruïlla entre els fluxos de migració i d'informació i comunicació. Hi ha diversos factors que fan que valgui la pena adoptar aquesta perspectiva. El punt central és que la migració internacional contemporània és incrustada en la dinàmica de la societat de la informació, seguint models comuns i dinàmiques interconnectades. Per consegüent, s'està començant a identificar els fluxos d'informació com a qüestions clau en les polítiques de migració. A més, hi ha una manca de coneixement empíric en el disseny de xarxes d'informació i l'ús de les tecnologies d'informació i comunicació en contextos migratoris. Aquest document de treball també mira de ser una font d'hipòtesis per a investigacions posteriors.
Resumo:
Purpose: Mediums have been developed to conserve corneal endothelium in organ-culture during eye banking. CorneaMax® is used by 25% of Eye Bank in Europe. Only little is known about conservation of corneal epithelium with this medium during banking. Its preservation could be of interest in clinic to cure corneal disease with stem cells deficiency. Therefore, we wanted to examine the integrity of human corneal epithelium maintained in CorneaMax®. Methods: Human corneas, considered unsuitable for transplantation, were obtained from the Eye Bank in Lausanne. Average post-mortem time was 14 hours. Cornoscleral rings were maintained in organ-culture in Corneamax® at 32°C. Samples were formalin-fixed after period ranging from 0 (D0) to 35 days (D35, N=5 for each time points) and stained with H&E. Proliferation and apoptosis were evaluated by immunostaining with antibody against Ki67 and Caspase3 respectively. Results: Corneas, which were not in organ-cultured (D0), showed different morphology, including intact epithelium with 5 to 7 layers, but also completely denuded basement membrane. In two cases, at D0, the epithelium lost its adherence to the basal lamina of the cornea creating a large epithelial sheet. During the two first days, corneas and limbus area lost totally their epithelium, except for some remaining limbal basal cells. From day 2 to day 10, regeneration of the epithelium took place, starting from the limbal region in direction to the central cornea. From day 10 to day 35, corneal epithelium appeared as an atrophic epithelium, consisting of only two cell layers. Proliferation happened in the whole cornea during the 35 days of organ-culture, as shown by Ki67 positive cells. Apoptosis was rarely detected in the corneal epithelium. Conclusions: Corneas maintained in CorneaMax® showed a complete disappearance of the corneal epithelium during the two first days and a conservation of limbal basal cells in the limbal region. These remaining cells allowed a full regeneration of the tissue, leading to an atrophic epithelium, composed of only two cell layers. This atrophic epithelium could be seen in all the organ-cultured corneas during the 35 days of conservation. This study is a first step to develop medium in organ-culture in order to conserve corneal epithelial cells.
Resumo:
PURPOSE: Drug delivery to treat diseases of the posterior segment of the eye, such as choroidal neovascularization and its complications, is hampered by poor intraocular penetration and rapid elimination of the drug from the eye. The purpose of this study was to investigate the feasibility and tolerance of suprachoroidal injections of poly(ortho ester) (POE), a bioerodible and biocompatible polymer, as a biomaterial potentially useful for development of sustained drug delivery systems. METHODS: After tunnelization of the sclera, different formulations based on POE were injected (100 microL) into the suprachoroidal space of pigmented rabbits and compared with 1% sodium hyaluronate. Follow-up consisted of fundus observations, echography, fluorescein angiography, and histologic analysis over 3 weeks. RESULTS: After injection, POE spread in the suprachoroidal space at the posterior pole. It was well tolerated and progressively disappeared from the site of injection without sequelae. No bleeding or retinal detachment occurred. Echographic pictures showed that the material was present in the suprachoroidal space for 3 weeks. Angiography revealed minor pigment irregularities at the site of injection, but no retinal edema or necrosis. Histology showed that POE was well tolerated in the choroid. CONCLUSIONS: POE suprachoroidal injections, an easy, controllable, and reproducible procedure, were well tolerated in the rabbit eye. POE appears to be a promising biomaterial to deliver drugs focally to the choroid and the retina.