906 resultados para Electrical bias


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major challenge of cardiac tissue engineering is directing cells to establish the physiological structure and function of the myocardium being replaced. In native heart, pacing cells generate electrical stimuli that spread throughout the heartcausing cell membrane depolarization and activation of contractile apparatus. We ought to examine whether electricalstimulation of adipose tissue-derived progenitor cells (ATDPCs) exerts phenotypic and genetic changes that enhance theircardiomyogenic potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was performed in an attempt to develop an in vitro integrated testing strategy (ITS) to evaluate drug-induced neurotoxicity. A number of endpoints were analyzed using two complementary brain cell culture models and an in vitro blood-brain barrier (BBB) model after single and repeated exposure treatments with selected drugs that covered the major biological, pharmacological and neuro-toxicological responses. Furthermore, four drugs (diazepam, cyclosporine A, chlorpromazine and amiodarone) were tested more in depth as representatives of different classes of neurotoxicants, inducing toxicity through different pathways of toxicity. The developed in vitro BBB model allowed detection of toxic effects at the level of BBB and evaluation of drug transport through the barrier for predicting free brain concentrations of the studied drugs. The measurement of neuronal electrical activity was found to be a sensitive tool to predict the neuroactivity and neurotoxicity of drugs after acute exposure. The histotypic 3D re-aggregating brain cell cultures, containing all brain cell types, were found to be well suited for OMICs analyses after both acute and long term treatment. The obtained data suggest that an in vitro ITS based on the information obtained from BBB studies and combined with metabolomics, proteomics and neuronal electrical activity measurements performed in stable in vitro neuronal cell culture systems, has high potential to improve current in vitro drug-induced neurotoxicity evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As increasingly large molecular data sets are collected for phylogenomics, the conflicting phylogenetic signal among gene trees poses challenges to resolve some difficult nodes of the Tree of Life. Among these nodes, the phylogenetic position of the honey bees (Apini) within the corbiculate bee group remains controversial, despite its considerable importance for understanding the emergence and maintenance of eusociality. Here, we show that this controversy stems in part from pervasive phylogenetic conflicts among GC-rich gene trees. GC-rich genes typically have a high nucleotidic heterogeneity among species, which can induce topological conflicts among gene trees. When retaining only the most GC-homogeneous genes or using a nonhomogeneous model of sequence evolution, our analyses reveal a monophyletic group of the three lineages with a eusocial lifestyle (honey bees, bumble bees, and stingless bees). These phylogenetic relationships strongly suggest a single origin of eusociality in the corbiculate bees, with no reversal to solitary living in this group. To accurately reconstruct other important evolutionary steps across the Tree of Life, we suggest removing GC-rich and GC-heterogeneous genes from large phylogenomic data sets. Interpreted as a consequence of genome-wide variations in recombination rates, this GC effect can affect all taxa featuring GC-biased gene conversion, which is common in eukaryotes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study is to review highly cited articles that focus on non-publication of studies, and to develop a consistent and comprehensive approach to defining (non-) dissemination of research findings. SETTING: We performed a scoping review of definitions of the term 'publication bias' in highly cited publications. PARTICIPANTS: Ideas and experiences of a core group of authors were collected in a draft document, which was complemented by the findings from our literature search. INTERVENTIONS: The draft document including findings from the literature search was circulated to an international group of experts and revised until no additional ideas emerged and consensus was reached. PRIMARY OUTCOMES: We propose a new approach to the comprehensive conceptualisation of (non-) dissemination of research. SECONDARY OUTCOMES: Our 'What, Who and Why?' approach includes issues that need to be considered when disseminating research findings (What?), the different players who should assume responsibility during the various stages of conducting a clinical trial and disseminating clinical trial documents (Who?), and motivations that might lead the various players to disseminate findings selectively, thereby introducing bias in the dissemination process (Why?). CONCLUSIONS: Our comprehensive framework of (non-) dissemination of research findings, based on the results of a scoping literature search and expert consensus will facilitate the development of future policies and guidelines regarding the multifaceted issue of selective publication, historically referred to as 'publication bias'.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pulseless electrical activity (PEA) cardiac arrest is defined as a cardiac arrest (CA) presenting with a residual organized electrical activity on the electrocardiogram. In the last decades, the incidence of PEA has regularly increased, compared to other types of CA like ventricular fibrillation or pulseless ventricular tachycardia. PEA is frequently induced by reversible conditions. The "4 (or 5) H" & "4 (or 5) T" are proposed as a mnemonic to asses for Hypoxia, Hypovolemia, Hypo- /Hyperkalaemia, Hypothermia, Thrombosis (cardiac or pulmonary), cardiac Tamponade, Toxins, and Tension pneumothorax. Other pathologies (intracranial haemorrhage, severe sepsis, myocardial contraction dysfunction) have been identified as potential causes for PEA, but their respective probability and frequencies are unclear and they are not yet included into the resuscitation guidelines. The aim of this study was to analyse the aetiologies of PEA out-of-hospital CA, in order to evaluate the relative frequencies of each cause and therefore to improve the management of patients suffering a PEA cardiac arrest. Method: This retrospective study was based on data routinely and prospectively collected for each PEMS intervention. All adult patients treated from January 1st 2002 to December 2012 31st by the PEMS for out-of-hospital cardiac arrest, with PEA as the first recorded rhythm, and admitted to the emergency department (ED) of the Lausanne University Hospital were included. The aetiologies of PEA cardiac arrest were classified into subgroups, based on the classical H&T's classification, supplemented by four other subgroups analysis: trauma, intra-cranial haemorrhage (ICH), non-ischemic cardiomyopathy (NIC) and undetermined cause. Results: 1866 OHCA were treated by the PEMS. PEA was the first recorded rhythm in 240 adult patients (13.8 %). After exclusion of 96 patients, 144 patients with a PEA cardiac arrest admitted to the ED were included in the analysis. The mean age was 63.8 ± 20.0 years, 58.3% were men and the survival rate at 48 hours was 29%. 32 different causes of OHCA PEA were established for 119 patients. For 25 patients (17.4 %), we were unable to attribute a specific cause for the PEA cardiac arrest. Hypoxia (23.6 %), acute coronary syndrome (12.5%) and trauma (12.5 %) were the three most frequent causes. Pulmonary embolism, Hypovolemia, Intoxication and Hyperkaliemia occurs in less than 10% of the cases (7.6 %, 5.6 %, 3.5%, respectively 2.1 %). Non ischemic cardiomyopathy and intra-cranial haemorrhage occur in 8.3 % and 6.9 %, respectively. Conclusions: According to our results, intra-cranial haemorrhage and non-ischemic cardiomyopathy represent noticeable causes of PEA in OHCA, with a prevalence equalling or exceeding the frequency of classical 4 H's and 4 T's aetiologies. These two pathologies are potentially accessible to simple diagnostic procedures (native CT-scan or echocardiography) and should be included into the 4 H's and 4 T's mnemonic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a new kernel estimation of the cumulative distribution function based on transformation and on bias reducing techniques. We derive the optimal bandwidth that minimises the asymptotic integrated mean squared error. The simulation results show that our proposed kernel estimation improves alternative approaches when the variable has an extreme value distribution with heavy tail and the sample size is small.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the thesis the principle of work of eddy current position sensors and the main cautions that must be taken into account while sensor design process are explained. A way of automated eddy current position sensor electrical characteristics measurement is suggested. A prototype of the eddy current position sensor and its electrical characteristics are investigated. The results obtained by means of the automated measuring system are explained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this paper is to describe a complete and extensive prototype design of a fixed electrical attenuator. The paper starts by describing the function and by giving some basic information about the attenuators. After a comprehensive description of the component, the facts of reverse engineering are discussed. The method itself is applied to ease manufacturing and design stages of this component. Information about materials and applied manufacturing technologies are also included in this report. By applying some specified DFMA-aspects the final design turned out to be a potential prototype device to be manufactured and for further analyse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid electric vehicles (HEV) have attracted very much attention during the latest years. Increasing environmental concern and an increase in fuel prices are key factors for the growing interest towards the HEV. In a hybrid electric vehicle the power train consists of both a mechanical power system and an electric power transmission system. The major subsystems in the mechanical power system are the internal combustion engine which powers the vehicle; electric power transmission including an energy storage, power electronic inverter, hybrid control system; the electric motor drive that runs either in the generating mode or in the motoring mode to process the power flow between the energy storage and the electrical machine. This research includes two advanced electric motors for a parallel hybrid: induction machine and permanent magnets synchronous machine. In the thesis an induction motor and a permanent magnet motor are compared as propulsion motors. Electric energy storages are also studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the main industries which form the basis of Russian Economical structure is oil and gas. This industry is also playing a significant role for CIS countries. Oil and gas industry is developing intensively attracting foreign investments. This situation is providing sustainable development of machinery production for hazardous areas. Operating in oil and gas areas is always related with occurrence of explosion gas atmospheres. Machines for hazardous areas must be furnished with additional protection of different types. Explosion protection is regulated with standards according to which equipment must be manufactured. In Russia and CIS countries explosion-proof equipment must be constructed in compliance with GOST standards. To confirm that equipment is manufactured according to standards’ requirements and is safe and reliable it must undergo the approval procedure. Certification in Russia is governed by Federal Laws and legislation. Each CIS country has its own approval certificates and permissions for operating in hazardous areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The directional consistency and skew-symmetry statistics have been proposed as global measurements of social reciprocity. Although both measures can be useful for quantifying social reciprocity, researchers need to know whether these estimators are biased in order to assess descriptive results properly. That is, if estimators are biased, researchers should compare actual values with expected values under the specified null hypothesis. Furthermore, standard errors are needed to enable suitable assessment of discrepancies between actual and expected values. This paper aims to derive some exact and approximate expressions in order to obtain bias and standard error values for both estimators for round-robin designs, although the results can also be extended to other reciprocal designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thesis examines System Integration and original equipment manufacturer (OEM) channel in the St. Petersburg drives market. The aim of the study was to increase understanding the relationship between OEM and SI and producers, problems and ongoing trends. The collected data was analyzed in order to find out which features of a power electronic drive product exercise a significant influence for the Russian companies decision. An essential part of this study was interviews as primary information sources, organized with SI and OEM companies which represented the basic SPb industry segments. The wholesalers and end users are left out from the analysis. The collected data was analyzed in order to find out which features of a power electronic drive product exercise a significant influence for the Russian companies decision.